Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for...

6
> Ventilation Air Conditioning Refrigeration Heating 22 º C Inside OUTSIDE HUMIDITY PROVIDED BY HEINEN & HOPMAN 35 C 90% PRODUCTS Duct fan WMR

Transcript of Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for...

Page 1: Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well

>

Ventilation Air Conditioning RefrigerationHeating

22ºCInside

OUTSIDEHUMIDITY

PROVIDED BYHEINEN & HOPMAN

35 C

90%

productsduct fan WMr

Page 2: Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well

To stand by our clients in the harshest environments

“ “

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Page 3: Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

WMR ducT fan

applicationMarine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well as offshore objects.

Temperature of conveyed medium must not exceed +45 0C, dust content 0.3g/m3. design features• Made of steel or plastic, with epoxy coating• Speed-controllable using optional solid-state speed control• Fans can be used to supply or exhaust air• Fans can be installed horizontally and vertically• Fans can be installed in flexible or rigid duct• Extensive range of accessories constructionCasing and impeller are made of PA2 aluminum sheets, welded. A terminal box with G20 cable gland, for feeding cable connection, is fitted on the casing. Electric motor: induction, squirrel-type, 3-phase, IP55 enclosure, in marine execution.

classification

dimensions Duct ventilation 1-phase and 3-phase

Type DN ØD L H E F V / Hz

WMR 100 / L 100 244 290 175 35 25 230 / 50 - 60

WMR 125 / L 125 264 315 185 35 25 230 / 50 - 60

WMR 160 / L 160 338 340 225 35 25 230 / 50 - 60

WMR 200 / M 200 338 400 225 40 30 230 / 50 - 60

WMR 200 / L 200 418 400 266 40 30 230 / 50 - 60

Dimensions in mm

Page 4: Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Type WMR 100 / L WMR 125 / L WMR 160 / L WMR 200 / M WMR 200 / L

Nominal diameter (mm) 100 125 160 200 200

Power consumption (kW)

0.05 0.07 0.13 kW 0.21 kW 0.40

Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])

mSg56-2A

0.090.322800

3x380 / 504.455

mSg56-2B

0.120.352800

3x380 / 505.058

mSg63-2A

0.180.552760

3x380 / 507.862

mSg63-2B

0.250.652760

3x380 / 509.363

mSg71-2B

0.551.352790

3x380 / 501465

Power consumption (kW)

0.07 0.10 0.21 0.28 0.59

Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])

mSg56-2A

0.110.353380

3x440 / 604.456

mSg56-2B

0.140.353380

3x440 / 605.059

mSg63-2B

0.290.653330

3x440 / 607.863

mSg63-2A

0.431.003400

3x440 / 609.664

mSg71-2B

0.641.353400

3x440 / 601466

WMR (3-phase) specifications

Performance chart (50Hz and 60Hz)

Page 5: Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Type WMR 100 / L WMR 125 / L WMR 160 / L WMR 200 / M WMR 200 / L

Nominal diameter (mm) 100 125 160 200 200

Power consumption (kW)

0.05 0.07 0.13 kW 0.21 kW 0.40

Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])

mSEg56-2A

0.090.852860

1x220 / 504.455

mSEg56-2B

0.121.0

28601x220 / 50

5.058

mSEg63-2A

0.181.5

28201x220 / 50

7.862

mSEg63-2B

0.251.852850

1x220 / 509.363

mSEMg71-2C

0.554.0

28001x220 / 50

1465

Power consumption (kW)

0.07 kW 0.10 kW 0.21 kW 0.28 kW 0.59 kW

Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])

mSEg56-2A

0.111.0

34301x220 / 60

4.456

mSEg56-2B

0.141.153430

1x220 / 605.059

mSEg63-2B

0.291.753380

1x220 / 607.863

mSEg63-2C

0.432.453400

1x220 / 609.564

mSMg71-2C

0.644.6

34001x220 / 60

1466

centrifugal WMR (1-phase) duct fan specifications

Performance chart (50Hz and 60Hz)

Page 6: Duct Fan - WMR - Heinen & Hopman · WMR ducT fan application Marine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well

www.heinenhopman.com

Heinen & Hopman encourages a more

sustainable world. By providing eco-friendly solutions and serviceswe offer our clients

the option of reducing energy consumption

and thus co2 emissions. Visit

greenmanifest.info for more information.

BrazilT: +5521 3587 4241/4244E: [email protected]

france - La ciotatT: +334 4204 8685E: [email protected]

france - GrasseT: +336 3090 7786 E: [email protected]

GermanyT:+49 4073 1680E: [email protected]

IndiaT: +9133 6499 1293E: [email protected]

ItalyT: +3901 8745 7970E: [email protected]

The netherlands (HQ)T: +313 3299 2500E: [email protected]

The netherlands (Rotterdam)T: +317 8890 8050E: [email protected]

norwayT: +47 6919 0900E: [email protected]

Peoples Republic of chinaT: +8621 3253 2896E: [email protected]

Peoples Republic of chinaT: +86 510 8528 1763E: [email protected]

PolandT: +489 1433 1800E: [email protected]

RomaniaT: +402 3644 8222E: [email protected]

RussiaT: +7 (4012) 308 801E: [email protected]

SingaporeT: +65 6897 7879E: [email protected]

South KoreaT: +8270 4901 0000E: [email protected]

SpainT: +349 3225 9668E: [email protected]

SwedenT: +46 3121 7500E: [email protected]

TurkeyT: +9021 6493 8118E: [email protected]

uaE (abu dhabi) T:+971 2550 4147E: [email protected]

uaE (dubai)T: +971 4263 5453E: [email protected]

uSa - fort Lauderdale, floridaT: +195 4463 0110E: [email protected]

uSa - Houma, Louisiana T: +198 5876 7989E: [email protected]