Ductwork Considerations• Shape• Size• Aspect ratio• Velocity• Static Pressure of the system• Space conflicts

Page 3: Duct design .ppt

Terms• Aspect ratio• Flexible ductwork• Overhead system• Underfloor air

distribution (UFAD) system

• Displacement system

• Dumping

• Diffuser• Grille• Register• Slot diffuser• Shift Zone• Plenum

Page 4: Duct design .ppt

Materials• Sheet metal (by

gauge)• Galvanized • Iron• Aluminum• Stainless steel

• Flexible• Insulated• Tube (socks)

• Other• PVC• Fiberglass

Page 5: Duct design .ppt

Congested Corridors

Page 6: Duct design .ppt

Shape and Size

Round

Oval

Rectangular

Page 7: Duct design .ppt

Rectangular• Lower aspect ratios

• More energy efficient• Use less ductwork

• Velocity and Area have an inverse relationship to the CFM (CFM = V x A)

• Velocity and Pressure Drop have a direct relationship

W

D

Aspect ratio = W / D

1 to 1

Page 8: Duct design .ppt

Air Distribution Systems• Three Types

• Above Ceiling• Displacement• Underfloor

• Services• Supply air• Return air• Ventilation air• Relief air• Exhaust air

Page 9: Duct design .ppt

Above Ceiling Distribution System

horizontalheat pump

supplyduct

returnduct

diffuser

return airgrille

American Standard © 1999

Page 10: Duct design .ppt

Dilute the Air

+ pressure

1600 CFM

200 CFM

1400 CFM

OA

SA

RA MA1600 CFM

Page 11: Duct design .ppt

Outside Air (OA) v. “Fresh Air”• Source of outside

air must be carefully considered.

• May have to pre-filter or condition

Page 12: Duct design .ppt

Other Design Considerations• Thermal mass• Prevailing winds• Natural light• Solar shading• Control strategies• Life safety issues• Infiltration• Bioterrorism

• Mixed Air (MA) conditions

• Energy in the air• Comfort level of

the air• The amount of

water in the air

Page 13: Duct design .ppt

Diffusers/Grilles/Registers

Page 14: Duct design .ppt

Short Circuiting

Page 15: Duct design .ppt

DISPLACEMENT PRINCIPLES

•Conditioned air moves upward past the persons breathing zone.

•This invisible plume continues an upward movement toward the ceiling.

•A person will breathe lower contaminant levels vs. a mixing design.

DISPLACEMENT DIFFUSERS RECESSED IN WALL

Page 16: Duct design .ppt

UNOCCUPED ZONE

SHIFT ZONE

OCCUPIED ZONE:

TEMPERATURE GRADIANT

HE IGHT

Thermal Displacement VentilationTemperature Stratification

By only cooling the occupied zone, tonnage requirements may be reduced

Page 17: Duct design .ppt

DISPLACEMENT: Delivering fresh air where it is needed

•Better IAQ, lower particulate concentrations than mixing systems.

•Increase use of outdoor air without energy penalty.

•Quiet diffusers, draftless conditions for the occupants.

Page 18: Duct design .ppt

Displacement Advantages/Disadvantages

• Advantages• Moderate supply air

temperature• Low velocity• Air delivered to the

comfort zone without mixing

• Aesthetics• Better IAQ• Can accommodate

more outside air for same energy cost

• Very quiet

• Disadvantages• Higher initial cost• Less well understood• Aesthetics• Too quiet

Page 19: Duct design .ppt

Underfloor System

• Reduces floor to floor height

Page 20: Duct design .ppt

Underfloor Systems

Page 21: Duct design .ppt

▪Passive swirl diffusers; pressurized plenum; displacement theory

▪Occupant may control airflow volume; 3’ clear zone around diffuser

Air Delivery: UF-HVAC Diffuser Types

Tate Building Technology Platform®

Page 22: Duct design .ppt

Rooftop Chiller HVAC SolutionEquipment room(chiller, pumps, controls)

Chilled water supply& return

Cooling tower

Supply air outlet

Stub duct

Indoor air handler

VAV MIT terminals

Supply air loop

Tate Building Technology Platform®

Page 23: Duct design .ppt

Take-Aways (The Ah Hahs)• Eliminate the contaminant is

always the first step• Capture it if you can’t eliminate it

• Healthy buildings are well ventilated• Watch your outside air sources!

• Operating cost and usually first cost go up as your ventilation goes up

Page 24: Duct design .ppt

Access Floors…

Advancements in Building Systems

Page 25: Duct design .ppt

...they’re not just for Computer Rooms anymore!!

Advancements in Building Systems