Transcript of DSE-Wire quality test instrument catalog
Wire quality test
Instrument catalog
2
Optimizing the processes
Knowing and controlling the parameters within production of enamelled wire is absolutely cru-
cial for the economy in manufacturing of enamelled wire.
The Tangent Delta Tester from DSE Test Solutions delivers all the information needed for opti-
mising and controlling the many processes. The measured data are compressed and displayed
in a full curve, showing the Tangent Delta as a function of the temperature.
This method is the ultimate way of making a fast, accurate and reliable determination of the
enamelled curing, and at the same time, showing any residual solvents or additives in the insu-
lation. Both residual solvents and curing state are factors that have high influence on tempera-
ture index, lifetime and physical behaviour of the wire.
Valuable information in few minutes means
30 years in the wire business means Experience knowledge and support
Continuous innovation and development
Reliable supplier of instruments,
with a remarkable track record
Improve the quality
Time and cost savings
Documented quality control
Optimised production parameters
Reduction of scrap
Under cured Normal cured Over cured
DSE Domicile since 1981…
Vers
ion 3
.1
1988
1994
2008
TD9000
TD300
TD5
TD3
2014
No. 1 in Tangent Delta
3
TD5 Tangent Delta Tester
TD5 is suitable for quality control of enamelled
wire. During heat-up of the wire, the TD5
automatically calculates the TgD temperature
(Tangent Delta temperature).
With a full curve, it is possible to determine
and display all valuable information about the
quality of the wire, among others:
Enamel curing
Enamel quality
Residual solvent
Absorption of moisture
Enamel type ID, and combinations
Increased profitability in manufacturing
of enamelled wire
Easy and fast test/analysis of the selected
samples from the production means:
Improved quality
Time and cost savings
Documented quality control
Optimised production parameters
Reduction of scrap
The central component in a TgD tester is the
oven. With a temperature range up to 400oC
(optionally higher) the TD5 is designed for
testing any type of enamelled wire.
For manufacturing
TD5 is designed to deliver fast consistence
measurements with high reliability. Test results
are ready after 3 minutes, depending of the
size of wire
For laboratory
The accuracy in all parameters sets new
standards for what is possible. The high-
precision heating elements with IHR
(Integrated Heating Regulation) and access to
adjustment of parameters make it the best
oven for research and development.
TD5 Tangent Delta Tester
TD5 - built for the future!
TD5– Quality optimising technology
High temperature oven
High consistence of the measurements
Round and Flat wire in one system
High speed
High accuracy
Approve/reject function
Reference wire in display
Up to 99 pre-settings
Low maintenance needs
Multi user language
TD
5 T
an
gen
t D
elt
a T
este
r
High temperature oven
Round and Flat
0.008……..8 mm
Up to……..8x22 mm
4
Easy operation and helpful features
TD5 is user-friendly, and easy to operate.
Results can be compared directly on the
screen, also comparison with a reference curve
is possible. All made to simplify the subse-
quent analysis of test results. Handling of data
The use of Microsoft SQL
database structure ensures
easy saving and retrieving
of wire data from a local PC
or from a central server.
Advance Database search function
Efficient search function makes it possible to find
and combine data stored in the database. Re-
trieving data for e.g. a specific customer com-
bined with result and time is simply done by
means of few mouse clicks.
High precision and cooling technology
TD5 sets new standards with respect to low
maintenance needs. Extended service intervals
are ensured by using innovative mechanical
design and, combined with it’s top quality met-
al hardware, the number of samples which can
be handled between each service is very high.
The combination of convinc-
ing technology and the use
of passive neutral graphite
as external conductor make
it the instrument with the highest reliability,
and the best repeatable measuring results
available.
Data input
For fast and precise data input, pro-
duction code and wire ID ext.
can be entered into the data-
base via Barcodes.
TD
5 T
an
gen
t D
elt
a T
este
r
TD5 Features
Multiple Curves Reference curves
During measurement the curve is visible and
combined with a reference wire the operator
has the best possible overview.
Software option B
This software tool evaluates the PEI base coat
on self-bond wires (XWE types). A mathemati-
cal evaluation of the PEI curve lies beneath the
self-bond signal and the Tangent Delta curve.
This function eliminates the need for stripping
self-bonding overcoat of the wire.
Documentation of production quality
It is possible to make test reports in PDF format.
Following information can be added to each indi-
vidual sample: Enamel type, supplier name, order
number, machine ID and other comments at-
tached to the measurement in the remark field.
Company logo can be imported and shown on
pages. Updating information in the fields for
remarks is possible also after the test is
completed.
Approve/reject function
Limits for approval or rejection of a measur-
ing can be set for two tangents for easy eval-
uation of the results.
1. Tangent 2. Tangent
Set up menu
Up to 99 customised pre-sets can be stored,
and easily found in the drop down box at any
time.
5
Multi-language
The control software is at this stage available in
English, German, Chinese and Russian, contact
DSE Test Solutions for updated information.
Compare with reference wire
Up to 5 different curves can be displayed sim-
ultaneously. The possibility of comparing a
new measurement with a reference wire is
helpful in the interpretation of the result.
Flat up to ……..8x22 mm
Round 0.008mm ……..8 mm
Dimensions
Round and flat wire
TD5 is built to handle a wide range of dimen-
sions in both round and flat wire.
Multiple frequencies
For maximum flexibility during research and
development the following measuring frequen-
cies can be selected: 100 Hz, 120 Hz, 1 KHz,
10 KHz and 100 KHz.
Default according to the Norm IEC 60851-5
the measuring Frequency is 1KHz.
Calculation and presentation
TD5 starts to measure and calculate the TgD
temperature automatically when the sample
holder is loaded into the oven.
During the measurement, the development of
the curve is displayed on the monitor.
The software enables setting limits for the mini-
mum and maximum TgD temperatures.
In case TgD temperatures exceed the preset
limit values, an “Approved/Rejected” window
will appear.
Standard sample holder
Sample holder
The sample holder simplifies sample preparation,
and is designed for absolute minimum need of
maintenance. The standard sample holder can be
used for both round and flat wire.
TD
5 T
an
gen
t D
elt
a T
este
r
TD5 Features
Handle both round & flat wire
Sample holder for Ultra fine wire 0.008…..0.1mm
Fine wire sample holder
6
TD5 contains
Oven with high-precision temperature control-
ling unit, power supplies, precision analyser,
interface for PC via USB.
Temperature range 45-400oC
Resolution ±0.1oC
Readout ±0.1oC
Dimensions (DxWxH): 440x530x360 mm
Ambient temperature: 10˚C - 35˚C
Net weight 33 Kg
Implementation Standard: IEC 60851-5
Precision analyser
Tangent Delta resolution:
0.0005 at C > 100 pF
Measuring frequency 100 Hz, 120 Hz,
1 KHz, 10 KHz, 100 KHz
Measuring voltage 1 Volt RMS
PC
Type, size, RAM and hard disc according
to current standards
Flat-screen monitor
Keyboard and mouse
Windows 7
Mains supply
100..230 VAC ± 10%
50/60 Hz With protective ground
Power consumption approximately 0.5 kW
Setup: TD5 connected to PC and printer.
Included accessories
Sample holder, holder for sample holder, cables,
service kit, 10ps graphite bottles, applicators, wire
sample dryer, manual in
German, English or Chinese, application notes for
evaluation of Tangent Delta Temperature curves in
English.
Technical specifications
Standard wire sample holder
Wire range:
Round 0.02...8.0 mm
Flat up to 8.0 x 22.0 mm
Fine wire sample holder:
Fine wire range 0.008..0.1 mm
Software:
Multi curve function
Comparison with reference wire
Up to 99 pre-settings
Scales, DIN or Logarithmic view
Scaling D-values up to 1.0
Programmable oven temperature range
Password management
Advanced Microsoft SQL data base
Report in printable PDF format
Test limits for automatic approval or rejection
Automatic printout of the individual curves and the
calculated data
TD
5 T
an
gen
t D
elt
a T
este
r
TD5 Specifications
Calibration tubes
Holder “ Third hand”
Optional accessories
Spare part kit
Calibration tubes including certificate
Software option B for automatic evaluation of
self bonding wire.
7
TD
3 T
an
gen
t D
elt
a T
este
r
TD3 Tangent Delta Tester
TD3 Tangent Delta Tester
TD3 is applicable for quality control of enamelled
wire. During heat-up of the wire, the TD3
automatically calculates the TgD temperature
(Tangent Delta temperature).
With a full curve, it is possible to determine and
display valuable information about the quality of
the enamel, among others:
Enamel quality
Enamel curing
Residual solvents
Absorption of moisture
Enamel type ID, and combinations
Product description
The combination of reliable technology and the
use of non toxic passive neutral graphite as
external conductor ensures high reliability in all
types of enamel.
TD3 sets new quality standards with respect to
low maintenance needs. Extended service
intervals are ensured by using innovative
mechanical design and, combined with its top
quality metal hardware, the number of samples
which can be handled between each service is
very high.
Easy operation
TD3 offers user-friendly operation, thus
minimising the need for operational training.
Because the calculated results are displayed as
curves on the monitor, the subsequent analysis
of test results is easily made.
Suitable for laboratory and production
TD3 is designed for fast delivery of reliable test
results from production lines as well as laboratory
applications.
Oven and Controller built in one compact
unit
The oven, controller , precision analyser, and
power supplies are all built together in one stable
metal cabinet. The compactness and low weight
of the complete system makes it portable and
easy to move around inside a production plant.
For obtaining flexibility the system operates with
a standard configured Windows PC or Laptop and
different sizes of the PC Monitor
Communication between External PC and TD3
system is handled via USB standard interface.
High repeatability-Low maintenance
TD3– Cost efficient TgD tester
High repeatability of the measurements
Compare results with multiple curves
Round and Flat wire in one system
Multi language user interface
Reference wire in display
Approve/reject function
Up to 99 pre-settings
Compact and low weight
8
Multiple Curves
TD
3 T
an
gen
t D
elt
a T
este
r
TD3 Features
Fast measurements
It is designed for quick heat-up, and a full Tan-
gent Delta curve is produced in few minutes,
depending on enamel type and wire dimen-
sions.
The basis software for TD3 controls
Temperature range 40-350oC
Automatic calculation of TgD temperature
Printout of each curve and calculated data
(manual or automatic)
Rapport in PDF format
User-interface in multiple language
D-value axis scalable up to 1.0
Multiple tangent calculation
Approve/Reject function for 1. first Tan-
gent
MS-SQL database function
Software option A with additional features:
Compare result with multiple curves
Use of reference curves
Approve/reject function also for the
2. Tangent
Up to 99 pre-settings
Sample holders
The design of the sample holders for TD3 ensures easy applying of graphite combined with low need for
maintenance.
Heavy wire
2.0……..6 mm
Up to……..6x12 mm
Standard wire
0.05……..2.0 mm
Up to……..2.0 mm
Easy access for applying graphite
The zone for applying graphite is shown directly on the sample holder. Innovative design of the contact
blocks makes the inserting of the wire very easy and ensures a reliable contact to the wire.
Compare results with multiple curves
Results can be compared directly on the screen.
In multiple view up to 5 curves can be evaluated
simultaneously.
Software description
Optional features
Beside of the standard software package two op-
tions are available
9
TD
3 T
an
gen
t D
elt
a T
este
r
TD3 Features
TD3 contains
Oven with high-precision temperature
controlling unit, power supplies, measuring
bridge, USB interface for Windows 7 PC.
Temperature range 40-350oC
Resolution ±0.1oC
Readout ±0.1oC
Dimensions (DxWxH):500x360x280 mm
Ambient temperature: 10˚C - 35˚C
Net weight 15 Kg
Mains supply 100..230Vac±10% with pro-
tective ground
Power consumption max 500W
Implementation Standard: IEC 60851-5
Precision analyser
Tangent Delta resolution:
0.0005 at C > 100 pF
Measuring frequency: 1 KHz
Measuring voltage: 1 Volt RMS
Included accessories
One standard sample holder
Cables, plugs and sockets, wire sample
dryer.
10 pcs. graphite bottles and applicators
Application notes for evaluation of Tan-
gent Delta Temperature Curves in English
Optional accessories
Heavy wire sample holder
Spare part package
Calibration blocks including certificate.
Software option A
Software option B
Approve/reject function
Limits for approval or rejection of a measure-
ment can be set in order to avoid mistakes.
Optional also for 2. tangent.
1. Tangent 2. Tangent
Software option B
This software tool evaluates the PEI base coat
on self-bond wires (XWE types).
A mathematical evaluation of the PEI curve
lies beneath the self-bond signal and the Tan-
gent Delta curve. This function eliminates the
need for stripping the self-bonding overcoat of
the wire
Sample holder
TD3 Basic includes one sample holder.
Wire range: Round 0.05-2.0mm
Sample holder for Heavy wire (optional)
Wire range: Round from 2.0-6.0mm
Flat up to 6.0x12.0mm
Reference Curves
Reference curve can be selected and up to 3
reference curves can be attached to each set up
to simplify the subsequent analysis of test re-
sults.
Set up menu
Up to 99 customised pre-sets can be stored, and
easily found in the drop down box at any time.
Set up menu
Drop-down box
10
Description
TD9000 Tangent Delta Tester is the most
advanced and accurate tool for any type of enamel
or enamelled wire.
With the TD9000 it is possible to analyse
parameters such as curing of the enamel, residual
solvent, additives, etc. These parameters are all
essential for obtaining the right quality and
economy.
The TD9000 offers
High-standard laboratory tester for achieving
precise measurements
Flexible measuring setup, e.g. eight samples
with different dimensions can be measured
simultaneously
Comparison with reference wire
Multiple curves can be displayed simultaneously,
which simplifies the interpretation of the result
Selectable test frequencies for optimising the
measurement of different types of wires
All significant data stored in Microsoft SQL
database.
TD9000 Tangent Delta Tester
TD9000 is the pioneer among Tangent Delta test systems.
Eight samples of various dimensions can be measured
simultaneously.
The ultimate way
With this Tangent Delta method, determination
of the enamel curing and residual solvents in an
isolated wire is done very effectively. Preparing a
sample is simple too. The wire is de-isolated and
being prepared with graphite and in a special
setup it is possible to measure the capacitance
and the D-value.
Advanced calculating software makes it possible
to combine all significant information into one
very easyly readable and informative curve, and
make a print for documentation of the produc-
tion.
TD
90
00
Tan
gen
t D
elt
a T
este
r
11
TD
90
00
Tan
gen
t D
elt
a T
este
r
Eight precise individual measurements
TD9000 Tangent Delta Tester is able to perform
precise individual measurements of up to eight
samples at a time, and in less than one hour.
Maximum flexibility
TD9000 offers maximum flexibility, as it is possible
to simultaneously measure various diameters and
types of enamelled wire.
Multiple curves
More curves can be displayed simultaneously,
which simplifies the interpretation of the results.
Compare with reference wire
Up to 6 different curves can be displayed
simultaneously. The possibility of comparing a new
measurement with a reference wire is helpful in
the interpretation of the results.
Documentation of production quality
It is possible to add the following information to
each individual sample to secure measurement
documentation: enamel type, supplier name, and
machine no. Furthermore, all information can be
stored on the PC hard disk.
High temperature range
TD9000 is capable of making a precise
determination of the Tangent Delta Value up to
350°C. This means that almost any type of
enamelled wire can be tested, thus ensuring, the
quality of the production.
Ease of operation and information access
To facilitate operational ease no operator
attendance is required during the measuring
process. The display will show the development of
the individual curves as well as the oven
temperature. The process can be stopped and
stored at any time. After completion, all
measurements and curves of each sample are
printed automatically, and data are calculated.
Multiple measuring frequencies available
For obtaining the best test conditions, a wide
range of test frequencies is available:
50 Hz - 300 Hz, 1 KHz - 3 KHz, 10 KHz - 30 KHz,
100 KHz - 300 KHz.
Non-stop measuring
The TD9000 system is available with two ovens.
The two ovens enable non-stop measuring, which
minimises the time needed to perform quality
checks of enamelled wire.
Working principle of TD9000
TD9000 working principles are based on
determining the quality of the enamel by
measuring the relation between the Tangent Delta
(D-value) and the wire temperature.
This method was originally developed for Quality
control in enamelled wire production by DSE Test
Solutions. Today we have become are worldwide
supplier of quality test equipment for the
enamelled wire industry.
Handling of data
The use of Microsoft SQL database ensures easy
saving and retrieving of wire data from a local PC
or from a central server.
TD9000 Features
12
Software
Features
This software tool offers complete control of the entire
measuring process with a user-friendly menu in English
or German, including the following main features:
Individual temperature measuring ranges between
45 and 350°C for all 8 positions in the oven
D-value between 0 and 3.0
Up to 5 tangents
Visibility of all curves during measurement
Automatic pop-up warnings to prevent loss of data
Microsoft SQL database for storing data on a server
Automatic printout of the individual curves and the
calculated data
Automatic calculation of auxiliary lines and Tangent
Delta temperature
Multiple curve function with up to 10 curves in the
same graph
Comparison with a reference wire
Automatic calibration programme
Extended database with search features, enabling
the user to search using any stored data
Logarithmic or linear graphs
Multiple measuring frequencies
Implementation Standard : IEC 60851-5
Option B
This software tool evaluates the PEI base coat on self-
bonding wires (XWE types).
A mathematical evaluation of the PEI curve lies be-
neath the self-bond signal and the Tangent Delta
curve. This function eliminates the need for stripping
the self-bonding over coat of the wire.
Basic system
Oven
Capacity: 1-8 samples simultaneously
Temperature range: 45°C- 350°C
Resolution: ±0.1°C
Readout: ±1°C
TD
90
00
Tan
gen
t D
elt
a T
este
r
TD9000 Specification
Measuring bridge
High-precision component analyzer
IEEE-488 interface
Tangent Delta res. 0.0002 at C > 60 pF
Measuring frequencies:
50 Hz - 300 Hz - 1 KHz - 3 KHz - 10 KHz -
30 KHz - 100 KHz - 300 KHz
Measuring Voltage: 1Volt RMS
PC
Type, size, RAM and hard disk
according to current standards
Flat-screen monitor
Keyboard and mouse
Windows 7
Electronic module
For powering and controlling of the oven.
Accessories
TD9000 oven cooler
All cables, plugs, and sockets
Sample preparation kit
User manual in English
Application notes for evaluation of Tangent
Delta Temperature Curves
Specifications
Mains supply
Mains supply 230/115 VAC ± 10%,
50/60 Hz with protective ground
Power consumption approximately 1 KW
Ambient temperature: 10˚C - 35˚C
Mechanical specifications
Dimensions oven (DxWxH): 450x440x250mm
Net weight: 19 kg
Dim. I/O rack(DxWxH):370x425x130mm
Net weight: 15 kg
Gross weight total single system: 140kg
Gross weight total dual system: 169kg
Oven with standard or customised dimension
range
The oven is delivered as standard with 8 slots which
can handle wire dimensions:
Round wire from 0.010 to 2.0 mm
Flat wire up to 2.0 x 4.0 mm
Each system can also be customized at order to handle
following dimensions:
Round wire up to 8.0 mm
Flat wire up to 8.0 mm x 22.0 mm
Flat max 2.0 m x 4.0 mm standard version
Flat up to 8.0 x 22.0mm to be specified when ordering
Round 0.01mm ……..2.0 mm standard version
Round up to 8 mm to be specified when ordering
Dimensions
13
When the wire passes through the head the current being measured will reflect the insulation
properties of the enamel. The high voltage control circuit is designed with an advanced current control system to avoid
sparks damage of the wire insulation or electrode system. Based on the most advanced soft-
ware platform on the market, the HVC test system is applicable for testing all types of wire in-
sulation with a test voltage up to 6kV DC.
Basic operation principle
Most reliable quality control tool
Valuable documentation for each meter of a spool
Reduction of scrap Improved efficiency
Measurement with two level detection Storing of data on local or central server
HIGH VOLTAGE
CONTINUITY TESTER
In the HVC Systems there are two individually adjustable levels of detector threshold. The two
levels make it possible to devide the faults into groups for pin holes and weak spots.
The test results are collected and compressed by a processing module, a label printout allows the
manufacturer to mark or label each spool of produced wire. Connection to central server enables
calculation of thorough production statistics.
HV
C H
igh
Vo
ltag
e C
on
tin
uit
y
In-line Quality monitoring
14
HVC 360 Flexible Features
The low tension in soft brushes brings
new opportunities for superior quality
control of a wide range of dimensions -
and with a full 360-degree coverage.
The HVC Flexible features
Full 360 degree coverage
Wide range of dimensions
Low tension means no damage of the
enamel because of the very soft
conductive brushes
Easy to maintain
No damage from sparks
Wide output test Voltage range 350V
to 6 KV
Measuring according to standard:
NEMA MW 1000-2003 and
IEC 60851-5
OK Warning Alarm
HV
C H
igh
Vo
ltag
e C
on
tin
uit
y T
este
r
Data base with visible features
Complete overview in one picture
Zoom function provides precise infor-
mation meter for meter
Find defect meters on the spool
Database browser Single spool view
Select a Pre-set
To simplify the operation it is possible use up to
99 pre defined settings.
The predefined pre-sets can be password pro-
tected by the administrator of the system.
Settings in short form
Software Protection
It is possible to protect by means of password a
range of features in the software. The protection
level is divided into 3 different levels. Administra-
tor, Supervisor and Operator.
HVC Flexible High Voltage
Two Level detection TH1-TH2
By operating with two different thresholds/
sensitivities TH1 & TH2 it is possible to get a pre-
warnings in time before the wire turns into scrap.
The most sensitive threshold TH2 will start count-
ing failures caused by e.g. weak spots before
more serious problems are detected by TH1 as
shown below.
TH2 TH1
From details to complete overview
Weak spots Pin-holes
15
HV
C H
igh
Vo
ltag
e C
on
tin
uit
y T
este
r
Technical specifications
Dimensions for Heavy wire model
Height: From 0.5 mm to 8.0 mm
Width: From 2.0 mm to 26.0 mm
Round: From 2.0 mm to 8.0 mm
Dimensions for round wire model:
From 0.005 mm to 2.0 mm
PM-Processor Module
The Processor Module controls the electrode
systems. It collects, evaluates, and compresses
data and sends them to a network or a “stand
alone ” PC.
PM module features
LED indicators for the following functions
Insulation error High tension Reel change Meter count Remote control (PC connected)
I/O interface, including power supply to the
electrode systems (measuring head) Opto-isolated outputs for warning and alarm Test Voltage 350V to 6000V Serial RS485 interface Ambient temperature: 15˚C - 50˚C Humidity: 0-80% no condensation. Weight: 2 kg Line voltage: 115/230V± 10% 60/50 Hz
with protective ground
PC
The system operates from a standard PC with
Windows 7.
Database Access or Microsoft SQL Database
Included accessories
Cables for measuring head to processor
module 10m included per line.
Longer cables can be supplied on request Standard Holder for Measuring head
1 holder included per line Earth strap for each line
1 cable PM-PC RS485 per PC
Optional Accessories
DSE2100 Multiple position holder for
Measuring-Head RS232/RS485 converter per PC including
10m connection cable Latching relay for Alarm output
Test kit probe for test of setting
Set of spare brushes
Holder for measuring head
Each line includes a high-quality metal holder
which secures a stable mounting of the
measuring head. This means it is easy to
dismantle the unit for cleaning, etc.
0.5...8 mm
175 mm
72 mm Heavy wire
48 mm Round wire
48 mm 80 mm
2...26 mm
2 to 8 mm
0.005 to 2 mm
Implementation Standard:
NEMA 1000-2003, IEC 0851-5
Standard Holder Optional: Multi position holder
Continuity Tester
16
DSE Test Solutions A/S Sverigesvej 19 DK-8700 Horsens Denmark
Information in this document
is subject to change without
prior notice. © DSE Test Solutions A/S
Brazil
Aries Ltda.
Mr. Stefano Malpezzi Phone: +55 11 5051 2763
Mail:[email protected]
China
Peng Consulting Ltd.
Mr. Peng Qingxuan Phone: +86 756 8129 166
Mail:[email protected]
Greece
ModusPlan
Mr. Gregory Savidis Phone: +30 210 96 27 935
Mail: [email protected]
India
Vertical Technologies
Mr. Nara Phone: +91 44 4555 4141
Mobile: +91 98 4002 2588
Mail: [email protected]
Singapore
PT BUSINESS NETWORK Pte.Ltd
Mr. Garrie Giam Phone: +65 64 691 692
Mail: [email protected]
Syria
Techno Trade el Fouad Ltd.
Mr. Khalil Phone: +20 2 748 2484
Mail: [email protected]
Korea
Hada International
Mr. Pyung-Ho-Yang Phone: +82 31 469 5671
Fax: +82 31 466 1963
Mail: [email protected]
Japan
Fukase & Co., Ltd.
Mr. N. Fukase Phone: +81 43 276 0630
Mail: [email protected]
Egypt
Techno Trade el Fouad Ltd.
Mr. Khalil Phone: +20 2 748 2484
Mail: [email protected]
Jordan
Techno Trade el Fouad Ltd.
Mr. Khalil Phone: +20 2 748 2484
Mail: [email protected]
Malaysia
PT BUSINESS NETWORK Pte Ltd.
Mr. Garrie Giam Phone: +65 64 691 692
Fax: +65 64 666 936
Mail: [email protected]
Saudi Arabia
Techno Trade el Fouad Ltd.
Mr. Khalil Phone: +20 2 748 2484
Fax: +20 2 748 2484
Mail: [email protected]
Thailand
PT BUSINESS NETWORK Pte. Ltd.
Mr. Garrie Giam Phone: +65 64 691 692
Mail: [email protected]
Turkey
Emre Kutukoglu
Phone: +90 (532) 241 4911
Mail: [email protected]
Vietnam
PT BUSINESS NETWORK Pte.Ltd.
Mr. Garrie Giam Phone: 0065 64 691 692
Mail: [email protected]
Find your local contact for product availability and support
Tel : +45 7561 8811 Fax : +45 7561 5895 Web: www.dse.dk Mail : [email protected]
Taiwan
Analytik Jena Taiwan Co., Ltd.
Mr. Roger Chung TEL: +886-2-85227886
FAX: +886-2-85227514
Mail:[email protected]
Ukraine
LBU-Tech
Mr. Valeriy Yakovlev Phone: 0038 050 385 2199
Mail: [email protected]
Indonesia
PT BUSINESS NETWORK Pte Ltd.
Mr. Garrie Giam Phone: +65 64 691 692
Fax: +65 64 666 936
Mail: [email protected]
Mexico
JAN INGENIERÍA DE MÉXICO
Mr. Ing Javier Amaya Nava Phone: +52(55) 5549 6433
Fax: +52(55) 5549 6433
Mail:[email protected]