DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND ...
Transcript of DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND ...
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA
FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]
This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA
On RequestColors
Fire retardant thermoplastic compound R16 PVC-based H.R. and O.R. suitable for CPR (R16 quality)
MaterialSHEATH
NaturalColors
Fire retardant thermoplastic compound R16 PVC-based suitable for CPR (R16 quality)MaterialSHEATH
90 °CMax operating temperature
250 °CMax short circuit temperature
15 x Diam.Min. bending radiusMechanical and Installation:
Electrical:
≥ 5000 MOhm x kmInsulation resistance
4000 V a.c. x 10 minDielectric test cond/cond
600/1000 VVoltage rating
CHARACTERISTICS
Wire armour with counter spiral tape
Galvanized steel wire 0,6 mm ≤ 30 mm under armour diameter
Galvanized steel wire 0,9 mm ≥ 30 mm under armour diameter
Material
ARMOUR Type
Core are cabled with optimal lay lenghtTypeTOTAL CABLING
On RequestColors
Crosslinked elastomeric compound type HEPR suitable for CPR (G16 quality)MaterialINSULATION
Flexible annealed bare copper cl.5MaterialCONDUCTOR
CABLE CONSTRUCTION AND SPECIFICATIONS
IDENTIFICATION AND REACTION TO FIRE
FG16OR16FR16 - 0,6/1 kVCca-s3,d1,a3
DRAWING IS ONLY ILLUSTRATIVE
CPR cable - INSTRUMENTATION CABLES
FORELIND®
Special Electrical Cables
CEI 20-13 PQA - -Rubber insulated cables with rated voltages between 1 kV and 30 kV (where applicable)
CEI 20-11/0-1;V1 - -National annex to EN 50363-0: Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General Introduction
CEI 20-29 IEC 60228 EN 60228 (CEI EN 60228)
Conductors of insulated cables
STANDARDS OR SPECIFICATIONS CONSTRUCTION
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA
FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]
This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA
DATASHEET
PAGE 02CPR cable - INSTRUMENTATION CABLES
FORELIND®
Special Electrical Cables
CEI 20-108 - EN 50399(CEI EN 50399)
Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results
CEI 20-35/1-2 IEC 60332-1-2 EN 60332-1-2(CEI EN 60332-1-2)
Test on electric and optical fibre under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
STANDARDS OR SPECIFICATIONS TEST
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA
FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]
This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA
9000
9001
9002
9003
9004
9056
9005
9006
9007
9008
9009
9010
325
352
391
439
498834
711
834
1087
379
414
470
13,42
13,89
14,65
15,49
16,47
20,78
20,06
21,66
24,91
14,36
14,91
15,78
7,92
8,39
9,15
9,99
10,97
15,28
14,5616,16
19,41
8,86
9,41
10,28
13,3
13,3
13,3
13,3
13,3
13,3
13,3
13,3
13,3
7,98
7,98
7,98
FG16OR16FR16 - 0,6/1 kV - 2x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 3x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 4x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 5x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 7x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 10x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 12x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 16x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 24x1,5 mm2
FG16OR16FR16 - 0,6/1 kV - 2x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 3x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 4x2,5 mm2
Ohm/km mm mm kg/km
Max conductorresistance at 20°C
Nom. Underarmour Ø
Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )
9011
9012
9055
9013
9014
9015
9016
9017
9018
9057
9019
9020
534
623
665
901
10741452
457
513
588
705
534
621
16,76
18,03
18,99
22,01
23,87
27,94
15,54
16,18
17,2
18,45
16,6
17,33
11,26
12,53
13,49
16,51
18,37
22,24
10,0410,68
11,7
12,95
11,1
11,83
7,98
7,98
7,98
7,98
7,98
7,98
4,95
4,95
4,95
4,95
3,3
3,3
FG16OR16FR16 - 0,6/1 kV - 5x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 7x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 10x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 12x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 16x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 24x2,5 mm2
FG16OR16FR16 - 0,6/1 kV - 2x4 mm2
FG16OR16FR16 - 0,6/1 kV - 3x4 mm2
FG16OR16FR16 - 0,6/1 kV - 4x4 mm2
FG16OR16FR16 - 0,6/1 kV - 5x4 mm2
FG16OR16FR16 - 0,6/1 kV - 2x6 mm2
FG16OR16FR16 - 0,6/1 kV - 3x6 mm2
9021
9058
9022
9023
9024
9059
9025
9026
708
845
695
808
9481142
1012
1198
18,58
18,89
18,54
19,42
20,8
22,37
22,22
23,39
13,08
14,39
13,04
13,92
15,3
16,87
16,7217,89
3,3
3,3
1,91
1,91
1,91
1,91
1,21
1,21
FG16OR16FR16 - 0,6/1 kV - 4x6 mm2
FG16OR16FR16 - 0,6/1 kV - 5x6 mm2
FG16OR16FR16 - 0,6/1 kV - 2x10 mm2
FG16OR16FR16 - 0,6/1 kV - 3x10 mm2
FG16OR16FR16 - 0,6/1 kV - 4x10 mm2
FG16OR16FR16 - 0,6/1 kV - 5x10 mm2
FG16OR16FR16 - 0,6/1 kV - 2x16 mm2
FG16OR16FR16 - 0,6/1 kV - 3x16 mm2
( * ) Any other identification on request. Please contact our technical department
DATASHEET
PAGE 03CPR cable - INSTRUMENTATION CABLES
FORELIND®
Special Electrical Cables
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA
FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]
This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA
9027
9060
9028
9029
9030
9061
9031
9032
9033
9065
9062
1428
16,92
1297
1574
19252326
1759
2149
2505
2646
3405
25,25
27,64
24,2
25,53
27,94
30,53
28,9
30,8
32,57
33,97
37,77
19,75
21,94
18,7
20,03
22,24
24,61
23,224,88
24,45
27,85
30,85
1,21
1,21
0,78
0,78
0,78
0,78
0,554
0,554
0,554 for 35 mmq 0,780 for 25 mmq
0,554
0,554
FG16OR16FR16 - 0,6/1 kV - 4x16 mm2
FG16OR16FR16 - 0,6/1 kV - 5x16 mm2
FG16OR16FR16 - 0,6/1 kV - 2x25 mm2
FG16OR16FR16 - 0,6/1 kV - 3x25 mm2
FG16OR16FR16 - 0,6/1 kV - 4x25 mm2
FG16OR16FR16 - 0,6/1 kV - 5x25 mm2
FG16OR16FR16 - 0,6/1 kV - 2x35 mm2
FG16OR16FR16 - 0,6/1 kV - 3x35 mm2
FG16OR16FR16 - 0,6/1 kV - 3x35+1X25 mm2
FG16OR16FR16 - 0,6/1 kV - 4x35 mm2
FG16OR16FR16 - 0,6/1 kV - 5x35 mm2
Ohm/km mm mm kg/km
Max conductorresistance at 20°C
Nom. Underarmour Ø
Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )
9034
9035
9036
9063
9037
9038
9039
9040
9041
9042
2406
2952
3460
44842844
3981
4456
4029
5030
5717
33,86
36,08
37,71
43,91
34,78
38,56
39,79
42,76
45,99
47,86
27,74
29,76
30,79
36,57
28,66
32,91
32,65
35,42
38,45
40,32
0,386
0,386
0,386 for 50 mmq 0,780 for 25 mmq
0,386
0,272
0,272
0,272 for 70 mmq 0,554 for 35 mmq
0,206
0,206
0,206 for 95 mmq 0,386 for 50 mmq
FG16OR16FR16 - 0,6/1 kV - 2x50 mm2
FG16OR16FR16 - 0,6/1 kV - 3x50 mm2
FG16OR16FR16 - 0,6/1 kV - 3x50+1x25 mm2
FG16OR16FR16 - 0,6/1 kV - 5x50 mm2
FG16OR16FR16 - 0,6/1 kV - 2x70 mm2
FG16OR16FR16 - 0,6/1 kV - 3x70 mm2
FG16OR16FR16 - 0,6/1 kV - 3x70+1x35 mm2
FG16OR16FR16 - 0,6/1 kV - 2x95 mm2
FG16OR16FR16 - 0,6/1 kV - 3x95 mm2
FG16OR16FR16 - 0,6/1 kV - 3x95+1x50 mm2
9064
9043
9044
9045
9046
9047
6167
4415
5629
6616
5935
7380
50,37
42,3
45,5
47,95
52,04
55,53
42,63
34,96
37,96
40,41
44,0847,37
0,206
0,161
0,161
0,161 for 120 mmq 0,272 for 70 mmq
0,129
0,129
FG16OR16FR16 - 0,6/1 kV - 4x95 mm2
FG16OR16FR16 - 0,6/1 kV - 2x120 mm2
FG16OR16FR16 - 0,6/1 kV - 3x120 mm2
FG16OR16FR16 - 0,6/1 kV - 3x120+1x70 mm2
FG16OR16FR16 - 0,6/1 kV - 2x150 mm2
FG16OR16FR16 - 0,6/1 kV - 3x150 mm2
( * ) Any other identification on request. Please contact our technical department
DATASHEET
PAGE 04CPR cable - INSTRUMENTATION CABLES
FORELIND®
Special Electrical Cables
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA
FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]
This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA
9048
9049
9050
9051
9052
9053
9054
8185
6338
8083
9301
8979
11386
13214
53,06
50,82
54,45
56,65
61,86
66,07
69,22
50,39
43,08
46,29
48,49
53,2827,29
57,04
0,129 for 150 mmq 0,206 for 95 mmq
0,106
0,106
0,106 for 185 mmq 0,206 for 95 mmq
0,0801
0,0801
0,0801 for 240 mmq 0,129 for 150 mmq
FG16OR16FR16 - 0,6/1 kV - 3x150+1x95 mm2
FG16OR16FR16 - 0,6/1 kV - 2x185 mm2
FG16OR16FR16 - 0,6/1 kV - 3x185 mm2
FG16OR16FR16 - 0,6/1 kV - 3x185+1x95 mm2
FG16OR16FR16 - 0,6/1 kV - 2x240 mm2
FG16OR16FR16 - 0,6/1 kV - 3x240 mm2
FG16OR16FR16 - 0,6/1 kV - 3x240+1x150 mm2
Ohm/km mm mm kg/km
Max conductorresistance at 20°C
Nom. Underarmour Ø
Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )
( * ) Any other identification on request. Please contact our technical department
DATASHEET
PAGE 05CPR cable - INSTRUMENTATION CABLES
FORELIND®
Special Electrical Cables
Via Europa, 6 - 24055 Cologno al Serio (BG - ITALY)Phone + 39 035 899191 - Fax + 39 035 4819224www.forelind.com E-mail: [email protected]
FOR.EL.IND S.p.A.
Special Electrical Cables
®
FORELIND