Warwickshire Rugby Football Union Warwickshire Society of ...
Drainage Outfalls and Inlets - North Warwickshire
Transcript of Drainage Outfalls and Inlets - North Warwickshire
Headwall Drainage Outfalls and Inlets
ALTHON LIMITED, Vulcan Road South, Norwich NR6 6AF Telephone: 01603 488700 Fax: 01603 488598 Email: [email protected]
www.althon.co.ukIssue 5 - July 2009
Also from Althon
Please contact
Wherever water is to be fed from an open
watercourse into a pipe outlet, an Althon Silt
Trap Inlet should be provided. The sloped
grating minimises the risk of blockage from
floating material, and silt will be collected by
the Silt Chamber prior to the outfall pipe. Althon
manufacture a range of Silt Trap Inlets to cater
for pipework with an internal diameter of up
to and including 1200mm.
Althon Headwalls and Silt Traps have been
used on contracts requiring approval from
organisations such as the Environment Agency,
Local Authorities and the Highways Agency.
Althon Headwalls and Silt Traps are quick
and simple to install and reduce the need for
skilled labour.
Please note that the units shown are standard units but w
e may be able to offer variations on request
Althon Headwalls offer a cost effective alternative
to in-situ structures for connecting pipework
discharging into open watercourses. All drainage pipes
discharging into open watercourses, such as Swales,
Ditches, Ponds and Rivers, should be fitted with
a suitable headwall. These units help to protect
and locate outfall pipes and to minimise erosion
at the point of discharge. Althon Headwalls can
accommodate pipework with an internal diameter of
up to and including 1650mm ID and PCC Box Culverts
up to 2400mm wide x 1500mm deep. Multiple pipe
outlets can also be accommodated.
Headwall units can be fitted with or supplied with a
range of accessories such as Flap Valves, Penstocks,
Grates, Hand Railing etc. See pages 8 and 9 for details.
2
Structural Analysis in accordance with
BS EN 1992-1-1:2004 Eurocode 2: Design
of Concrete Structures is available for the
H3C, H6C, H10C, H20C, H28C, CH20C and
CH28C range of headwalls, please contact
the Althon Sales office for details.
IndexOverview Page 2
Precast Concrete Headwalls Page 3-7
Precast Concrete Headwall Specials Page 8-9
Precast Concrete Headwalls continued Page 10
Headwall Gratings and Ground Anchors Page 11
Precast Concrete Culvert Wingwalls Page 12
Glass Reinforced Cement Headwalls Page 13
Precast Concrete Silt Traps Page 14
Installation Instructions Page 15
Please note that the units shown are standard units but w
e may be able to offer variations on request
www.althon.co.uk
01603 488700
3
Althon Headwall H3C
Approximate weight 540kg.
A one-piece reinforced concrete headwall to suit Plastic or
Clayware pipes up to 300mm I.D. or PCC pipes up to 225mm
I.D. Stainless steel sockets are provided for the attachment of
gratings. Lifting points are cast in to each Wingwall for safe
handling using Althon Lifting Clutches.
A Toe extension piece is available for the H3C Headwall giving
an overall Toe depth of 810mm from the splashplate, see the
Althon website for details.
Althon Headwall H6C
A one-piece reinforced concrete headwall to suit Plastic or
Clayware pipes up to 500mm I.D. or PCC pipes up to 450mm
I.D. Available with three standard backwall heights, 1.1m,
1.5m and 2m, with Lifting points cast in to each Wingwall for
safe handling using Althon Lifting Clutches.
Stainless steel sockets are provided for the attachment of
Gratings and special brackets are available for use with the
anchorage system. See Page 11 for details.
Toe extension pieces are available for the H6C Headwall
giving an overall Toe depth of 710mm or 1015mm from the
splashplate, see the Althon website for details.
Headwall Max Pipe Opening (I.D.)
Plastic/C’ware
Max Pipe Opening
PCC
A B Approx Weight
kg
H6C A 500 450 1100 320 940
H6C B 500 450 1550 410 1150
H6C C 500 450 2050 410 1375
Precast Concrete Headwalls
Please note when reviewing this information openings shown on illustrations for pipe entry are indicative only.
See tables for maximum opening sizes.
If a Penstock or Flap Valve is to be fitted to the Headwall, the frame size will determine the maximum pipe
diameter that can be accommodated – please contact the Althon Sales Office for details.
Althon Headwall H10C
A one-piece reinforced concrete headwall to suit Plastic, Clayware
or PCC pipes up to 900mm I.D. Available with three standard
backwall heights, 1.25m, 1.65m and 2.1m, with Lifting points
cast in to each Wingwall for safe handling using Althon Lifting
Clutches. A spreader bar is also recommended for safe Handling.
The chains are threaded through this eliminating side load on the
vertical lift. Stainless steel sockets are provided for the attachment
of Gratings and special brackets are available for use with the
anchorage system. See Page 11 for details.
Toe extension pieces are available for the H10C Headwall giving
an overall Toe depth of 710mm or 1015mm from the splashplate,
see the Althon website for details.
Please note that the units shown are standard units but w
e may be able to offer variations on request
4
Althon Angled Headwalls
A one-piece reinforced concrete headwall to suit Plastic,
Clayware or PCC Pipes up to 900mm I.D. Available with
three standard backwall heights, 1.25m, 1.65m and
2.1m, with Lifting points cast in to each Wingwall for safe
handling using Althon Lifting Clutches. A spreader bar is
also recommended for safe handling. The chains are
threaded through this eliminating side load on the
vertical lift. Stainless steel sockets are provided for the
attachment of Gratings and special brackets are available
for use with the anchorage system. See Page 11 for
details. These headwalls allow pipework entering a
watercourse at an angle to be accommodated or for an Outfall to be sited on a bend in a river. The toe is cast separately and is available in depths
of 305, 610, 915, 1220 or 1420mm dependant on site conditions. The toe is fixed to the underside of the Headwall with 5 Stainless Steel Bolts
which are fastened from the top and are hidden in a recess cast into the splashplate.
Headwall Max Pipe Opening (I.D.)
Plastic/C’ware
Max Pipe Opening
PCC
A B Approx Weight
kg
H10C A 900 750 1250 300 2000
H10C B 900 900 1650 700 2300
H10C C 900 900 2130 200 2500
H10C D 900 750 1250 1150 2300
H10C E 900 900 1650 1550 2600
H10C F 900 900 2130 2030 2800
Please note that the units shown are standard units but w
e may be able to offer variations on request
5
www.althon.co.uk
01603 488700
Headwall Max Pipe Opening (I.D.)
Plastic/C’Ware
Max Pipe Opening (I.D.) PCC
A B C Approx Weight kg
AH10C RH A 900 750 1250 400 595 2000
AH10C RH B 900 900 1650 800 995 2300
AH10C RH C 900 900 2130 415 830 2500
A
B
1695mm
1850mm
1150mm
100mm
1265mm
100mm
C 1715mm
1300mm
305, 610, 915, 1220 or 1420mm
1995mm
1150mm
100mm
A
B
100mm
1850mm
C
1695mm
1265mm
1300mm
1715mm
1995mm
305, 610, 915, 1220 or 1420mm
Althon Angled Headwall AH10C RH
Althon Angled Headwall AH10C LH
1150mm
100mm
A
B
100mm
1850mm
C
1695mm
1265mm
1300mm
1715mm
1995mm
305, 610, 915, 1220 or 1420mm
Headwall Max Pipe Opening (I.D.)
Plastic/C’Ware
Max Pipe Opening (I.D.) PCC
A B C Approx Weight kg
AH10C LH A 900 750 1250 350 565 2000
AH10C LH B 900 900 1650 370 770 2300
AH10C LH C 900 900 2130 770 995 2500
6
2850mm
3685mm 100mm
A
200mm
B
300mm
1910mm
100mm
100mm
Please note that the units shown are standard units but w
e may be able to offer variations on request
Althon Headwall H20C
This is a sectional structure with rebated joint, assembled on site around
the drainage pipe and locked together by means of stainless steel
cast-in sockets and brackets provided. The H20C Headwall is suitable for
plastic or clayware pipes up to 1650mm I.D. or PCC pipes up to 1500mm
I.D. Available with three standard backwall heights, 1.25m, 1.65m and
2.1m, with Lifting points cast in to each Wingwall for safe handling using
Althon Lifting Clutches.
Headwall Max Pipe Opening (I.D.)
Plastic/C’ware
Max Pipe Opening (I.D.) PCC
Amm
Bmm
Approx Weight
kg
H20C A 900 900 1250 300 2600
H20C B 1050 1050 1650 700 3200
H20C C 1650 1500 2130 200 3600
H20C D 900 900 1250 1150 3000
H20C E 1050 1050 1650 1550 3600
H20C F 1650 1500 2130 2030 4000
Althon Headwall H28C
This is a sectional structure with rebated joint, assembled on site around
the drainage pipe and locked together by means of stainless steel
cast-in sockets and brackets provided. The H28C Headwall is suitable for
plastic pipes up to and including 1650mm ID or PCC Pipes up to and
including 1500mm ID. This headwall will also accommodate Twin pipe
openings of up to and including 1050mm ID plastic and 900mm ID PCC.
Available with three standard backwall heights, 1.25m, 1.65m and 2.1m,
with Lifting points cast in to each Wingwall for safe handling using Althon
Lifting Clutches. Stainless steel sockets are provided for the attachment of
Gratings and special brackets are available for use with the anchorage
system. See Page 11 for details.
2850mm
3685mm100mm
A
200mm
B
300mm
1910mm
100mm
100mm
Headwall Max Pipe Opening (I.D.)
Plastic
Max Pipe Opening (I.D.)
Concrete
A B Approx Weight kg
H28C A 900/Twin 900 750/Twin 750 1250 300 3400
H28C B 1200/Twin 1050 1050/Twin 900 1650 700 4100
H28C C 1650/Twin 1050 1500/Twin 900 2130 200 4400
Stainless steel sockets are provided for the attachment
of Gratings and special brackets are available for use
with the anchorage system. See Page 11 for details.
7
Headwall Max Internal Dimensions
PCC Box Culvert
A B Approx Weight
kg
CH28C A 2400 x 8001 1250 300 3400
CH28C B 2400 x 1200 1650 700 4100
CH28C C 2400 x 1500 2130 200 4400
Althon Culvert Headwall CH28C
This is a sectional structure with rebated joint, assembled on site
around the box culvert and locked together by means of stainless
steel cast-in sockets and brackets provided. The Althon Culvert
Headwall CH28C will accommodate culverts with a maximum
internal dimension of 2400mm wide x 1500mm high. Available
with three standard backwall heights, 1.25m, 1.65m and 2.1m,
with Lifting points cast in to each Wingwall for safe handling using
Althon Lifting Clutches. Stainless steel sockets are provided for
the attachment of Gratings and special brackets are available for
use with the anchorage system. See Page 11 for details.
2850mm
3685mm 100mm
A
200mm
B
300mm
1910mm
100mm
100mm
Please note that the units shown are standard units but w
e may be able to offer variations on request
www.althon.co.uk
01603 488700
2025mm
2855mm100mm
A
200mm
B
300mm
1910mm
100mm
100mm
Headwall Max Internal Dimensions PCC
Box Culvert
A B Approx Weight kg
CH20C A 1500 x 8001 1250 300 2600
CH20C B 1500 x 1200 1650 700 3200
CH20C C 1500 x 1500 2130 200 3600
CH20C D 1500 x 8001 1250 1150 3000
CH20C E 1500 x 1200 1650 1550 3600
CH20C F 1500 x 1500 2130 2030 4000
Althon Culvert Headwall CH20C
This is a sectional structure with rebated joint, assembled on site
around the box culvert and locked together by means of stainless
steel cast-in sockets and brackets provided. The Althon Culvert
Headwall CH20C will accommodate box culverts with a maximum
internal dimension of 1500mm wide x 1500mm high. Available
with three standard backwall heights, 1.25m, 1.65m and 2.1m,
with Lifting points cast in to each Wingwall for safe handling using
Althon Lifting Clutches. Stainless steel sockets are provided for
the attachment of Gratings and special brackets are available for
use with the anchorage system. See Page 11 for details.
8
Customer requests for alterations and additions to
our standard designs of drainage outlet over the years
have allowed us to gain considerable experience in
providing exactly what the client requires.
ExTENDED SPILLWAyS
DOVETAIL SLOTS CAST IN TO ALLOW CLADDING OF
WINGWALLS AND BACkWALL
ORIFICE PLATES (FLOW CONTROL)
ExTENDED TOES
HEADWALL ADAPTED FOR USE AS SILT TRAP
FLAP VALVES
ExTRA WEIR WALLS CAST IN (‘V” NOTCH)
MULTIPLE PIPE OPENINGS
9
HANDRAILING
PIPE OPENING IN WINGWALLS
STOP LOGS
ACCESS LADDERS OR RUNG IRONS CAST IN
PENSTOCkS
FLAP VALVES
This page gives an overview of the alterations and
additions that can be accommodated. For more specific
information, please visit our website www.althon.co.uk
If you can’t see what you are looking for please contact
our sales office on 01603 488700
DIFFUSER BLOCkS
www.althon.co.uk
01603 488700
10
Headwall Max Pipe Opening (I.D.)
Plastic/C’Ware
Max Pipe Opening (I.D.) PPC
A B Approx Weight kg
H40C A 600 525 1070 1120 700
H40C B 600 525 1070 1425 850
H40C C 600 525 1070 1730 980
H40C D 600 525 1070 2035 1120
H40C E 600 525 1070 2340 1280
Headwall Max Pipe Opening (I.D.)
Plastic/C’Ware
Max Pipe Opening (I.D.) PPC
A B Approx Weight kg
H42C A 600 600 1375 1120 810
H42C B 750 750 1375 1425 1070
H42C C 750 750 1375 1730 1230
H42C D 750 750 1375 2035 1390
H42C E 750 750 1375 2340 1550
Headwall Max Pipe Opening (I.D.)
Plastic/C’Ware
Max Pipe Opening (I.D.) PPC
A B Approx Weight kg
H44C A 600 600 1680 1120 990
H44C B 750 750 1680 1425 1170
H44C C 1200 1050 1680 1730 1380
H44C D 1200 1050 1680 2035 1540
H44C E 1200 1050 1680 2340 1730
80mm
100mm100mm
610mm 305mm
A
B
Althon Headwall H40 Series
A one-piece reinforced concrete headwall available in three widths
and five standard heights. Particularly suitable for steep embank-
ments. Due to the relatively narrow footprint of the unit (back to
front) it is advisable to fit suitable brackets to attach ground anchors
(see Page 11). The largest unit can accommodate PCC Pipes up to
1050mm I.D. and Plastic Pipes up to 1200mm I.D. Stainless steel
sockets are provided for the attachment of Gratings. Lifting points
are cast in to each Wingwall for safe handling using Althon Lifting
Clutches. Galvanised Mild Steel Angle can be fitted to the side
walls in order to fit Stoplogs and the back wall can be extended
horizontally through the fitting of side wall extensions if required. 80mm
100mm100mm
610mm 305mm
A
B
Please note that the units shown are standard units but w
e may be able to offer variations on request
11
Althon Headwall Ground Anchors
It may be felt necessary on some of the taller headwall units that
an anchor system is required. Althon can provide a Galvanised
Mild Steel Anchor system manufactured from 50 x 50mm Angle
Iron. The anchors are driven into the ground either side of the
pipe and are connected to the rear of the headwall with stainless
steel studding which can be up to 3000mm long. Backfilling is
then performed as normal.
Please note that the units shown are standard units but w
e may be able to offer variations on request
www.althon.co.uk
01603 488700
Up to 3000mm
580mm
900mm
Grating Configurations for Althon Headwalls
Standard Grating Sloped Grating Cranked Grating
Althon Headwalls can be supplied fitted with either Mild Steel
(unit fully welded then hot dip galvanised) or stainless steel
gratings. Three different configurations are available. Gratings
provide safety against persons entering the pipe or culvert and
protection against the ingress of debris.
The Sloped Grating is normally used where a Flap Valve is fitted;
it allows the Flap Valve to operate efficiently and offers better
protection against blockage as it allows debris to be pushed up
the grating as the water level rises, minimising build up and
potential blockage.
The Cranked Grating is normally used where a large Flap Valve
or Penstock is fitted. This type of grating allows the Flap Valve or
Penstock to operate efficiently. Special access points can be made
available within the grating to allow access to operating gear for
Penstocks etc.
Bespoke gratings can be manufactured to suit customer
requirements, please contact the Althon Sales Office for
further details.
12
Please note that the units shown are standard units but w
e may be able to offer variations on request
"L" Supports
Latticework to cast into base slab
Althon Culvert Wingwalls
Althon are able to offer a purpose made PCC Culvert Wingwall
system. The system comprises of “L” shaped supports that are
located on a lattice framework which is set into the concrete base
cast on site. Front and side walls up to 150mm thick are secured to
the supports by means of angle brackets which are at the rear of
the structure and not seen from the front. The front walls can be
cast to accommodate single or multiple pipe openings, box
culverts and corrugated steel culverts. The Wingwalls can be set
at any angle in relation to the Culvert end, and up to a maximum
height of 4m. Safety or Debris Gratings to suit the Culvert opening
can be supplied as well as other accessories such as Flap Valves,
Penstocks, and Handrails etc.
Each PCC Culvert Wingwall is designed to
suit a specific application and a full design
service is available, please contact the
Althon Sales office on 01603 488700Further examples of the types of Culvert Wingwalls
are available on our website www.althon.co.uk
13
Althon Headwall H3G
Approximate weight 150kg.
A one-piece glass reinforced cement (GRC) headwall with an
opening to suit 150mm diameter pipes and knockout webs to
enlarge to 225mm and 300mm diameter pipes.
Stainless steel sockets are provided for the attachment of gratings.
The dimensions of the unit are as the H3C PCC unit on page 3
with a reduced toe depth of 150mm and nominal wall thickness
of 20mm.
General Purpose Headwalls
Manufactured in GRC and provided with a unique anchorage
system. A lightweight recessed headwall suitable for most
situations where batter angle is not less than 45 degrees and for
use in minor water courses with moderate flows.
Althon Small General Purpose Headwall GPSMALL
A one-piece glass reinforced headwall with an opening to suit
80mm diameter pipes and knockout webs to enlarge
to 100mm and 150mm diameter pipes.
Althon Large General Purpose Headwall GPLARGE
A one-piece glass reinforced headwall with an opening to
suit 150mm diameter pipes and knockout webs to enlarge
to 225mm and 300mm diameter pipes.
Please note that the units shown are standard units but w
e may be able to offer variations on request
www.althon.co.uk
01603 488700
14
D
C
A
One Piece Heavy Duty Silt Trap Inlet
To suit Plastic and Clayware pipes up to 600mm I.D. and PCC pipes up to 525mm I.D.
A one-piece reinforced concrete unit with hinged grating and generous silt capacity. Lifting points are cast in to each wall for
safe handling using Althon Lifting Clutches.
Two Piece Heavy Duty Silt Trap Inlet
To suit Plastic, Clayware and PCC pipes up to 1200mm I.D.
Sturdy reinforced concrete structures for use on large diameter pipes and ideally
suited for use in water courses with high velocities of water flow. Heavy duty
galvanised steel weed screen with a removable centre panel for access to the silt
chamber is provided. Delivered complete with grating and all necessary fixings.
Lifting points are cast in to each wall for safe handling using Althon Lifting Clutches.
Heavy Duty Silt Trap
Max Pipe Opening
(I.D.) Plastic/
Clayware
Max Pipe Opening
(I.D.) Concrete
A B C D Approx Weight
kg
2PHDST A 750 675 1065 1220 400 1730 1360
2PHDST B 900 750 1370 1220 400 1730 1615
2PHDST C 1050 900 1675 1220 400 1730 1875
2PHDST D 750 675 1065 1220 400 2035 1500
2PHDST E 900 750 1370 1220 400 2035 1785
2PHDST F 1050 1050 1675 1220 400 2035 2070
2PHDST G 750 675 1065 1220 400 2340 1660
2PHDST H 900 750 1370 1220 400 2340 1955
2PHDST I 1200 1200 1675 1220 400 2340 2260
* Can be increased in 150mm increments to a maximum of 850mm
Heavy Duty Silt Trap
Max Pipe Opening
(I.D.) Plastic/
Clayware
Max Pipe Opening
(I.D.) Concrete
A B C D Approx Weight
kg
1PHDST A 600 525 1065 915 min 400* 1425 1250
1PHDST B 600 525 1065 915 min 400* 1730 1450
15
5. Mass concrete should be used to backfill in front and under
the toe and well compacted impervious clay around the
rest of the unit.
6. Position pipe in prepared trench and insert through
backwall of headwall (flush if with flap valve or grating
- 50mm protrusion if not).
7. Fill void around pipe with a good quality sand cement mortar.
8. Once satisfied with the positioning of the pipe, backfill in
accordance with Engineers instructions.
Angled Headwalls
Angled Headwalls are supplied with a separate toe and
therefore the order of installation differs slightly from above.
The toe should be installed first; mass concrete should be used
to backfill in front and under the unit. Lay a 100mm thick bed
of semi-dry concrete as a foundation to sit the headwall level or
with a slight fall (1:50) from pipe to spill mouth. This will allow
for the headwall then to be lowered over the M16 studs of the
separate toe piece and onto the pre-prepared foundation.
Silt Traps
1. Heavy Duty Silt Traps should be installed on a level base,
if necessary bed on 100mm of dry mixed concrete.
2. Two piece units should be lifted into position separately.
3. Ensure that the drain pipe is flush or slightly protruding
through the backwall.
4. On the two piece units use the four bolts through the
brackets at each side to keep the units together for
backfilling, do not over-tighten.
5. Fill void around pipe with a good quality sand cement mortar.
6. Clean out loose materials from the floor before fitting
the grating and its retaining brackets.
7. Carefully complete the backfilling and consolidate to
the original profile.
Installation InstructionsGeneral Purpose Headwalls
1. Dig out sufficiently to allow the headwall flanges to finish
flush with the batter.
2. Take the outfall pipe (minimum length 1.5m rigid
impervious pipe) and slide it through the headwall so
that it protrudes approximately 50mm.
3. Make a good connection with the land drain and seal
by returning approximately 150mm of soil into the trench
and consolidating.
4. Unravel the string and draw the anchor back along the
trench as the rest of the backfilling is completed.
Headwalls
Due to the wide variety of site conditions it is inappropriate to
give specific information on depths of dig under the structure
that is required to support the headwall. Because the ground
pressure is low (typically 6.5kn/m2) we suggest a sub base of
100mm dry mix concrete just to give a level foundation to sit
the headwall onto.
1. Dig out the bank of the watercourse to take the appropriate
size of the headwall making sure that the headwall will not
protrude into the path of the water flow.
2. Dig out sufficient size trench to take the toe along
the front of foundation. If an extended toe is required then
increase the depth of the dig to achieve required depth.
Note: If an extended toe is required place the headwall on
a sufficiently high platform to screw in M12 stainless steel
studding into sockets on underside of toe before placement.
3. Lay a 100mm thick bed of semi dry concrete as a
foundation to sit the headwall level or with a slight fall
(1:50) from pipe to spill mouth.
4. Using appropriate lifting clutches (available from Althon
Ltd) in the anchor positions on the wing walls (with
long chains or on H10C Headwalls a spreader bar to
prevent excessive side loading) lift the unit and carefully
manoeuvre into position on prepared foundation. (For the
H20C and H28C separate instructions are available on
request or can be viewed on our website.)
www.althon.co.uk
01603 488700
ALTHON LIMITED, Vulcan Road South, Norwich NR6 6AF Telephone: 01603 488700 Fax: 01603 488598 Email: [email protected]
www.althon.co.uk
SUPPLY
Ordering
Please contact our Sales Office at Norwich.
Prices and Conditions of Sale
Information on request from our Norwich office.
Delivery
Information on request from our Norwich office.
TECHNICAL SERVICES
To support architects, engineers and contractors in designing and installing the Headwall System, our
Design Services Department offers computer aided scheme design, hydraulic performance calculations
and advice on installation.
Contact Information
Our telephone hotline: 01603 488700
Fax line: 01603 488598 or
E-mail address: [email protected]
The information contained in this publication is believed to be correct at the date of publication, but it should
be understood that between publications there may be changes in pertinent standards or regulations affecting
the accuracy of the information contained therein.
Also from Althon
Please contact
Althon High Capacity Channel Drainage System
Althon SUDS The SEL Source Control System
Althon Pipe and Ground Equipment
Virtual Curtain Gas Migration Solutions