Dp Report Mk
description
Transcript of Dp Report Mk
ATV PROJECTS INDIA LTD. MATHURA
DYE PENETRENT TEST REPORT Ref. No.-ATV/QA/F/05 Rev-0
Customer name
M/S-FLSmidth pvt. Ltd.
Report No.
ATV/QC/13/458B
Project name
N.A.
Testing Date
06.08.2013
Order No.
N.A.
Drawing No.
N.A.
Component name
N.A.
Material & Grade
SA 516 GR. 70 (H. NO. 156016)
Component part
TEST PIECE (30X300X350) W-04+ W-24
Area Examined
DP carried out on weld joint after back chip
Stage
After Welding(WELDER QUALIFICATION)
APPLICABLE CODE/SPECIFICATION
REFERENCE STANDARD: ASME SEC-V ARTICLE-6
ACCEPTANCE STANDARD: ASME SEC-VIII DIV.I APPENDIX-8
QAP NO.- N.A.
TEST DETAIL
Material used
MAKE
MODAL
BATCH NO.
Test method
Solvent removal method
Cleaner type
CHEKMATE
CL -96
Cl-C-01-234
DWELL time
12 Minutes
Penetrate type
CHEKMATE
PT-97
Cl-P-01-229
Developing time
15 Minutes
Developer Type
CHEKMATE
DV-98
Cl-D-01-230
Surface condition
Free from dust & Greece
Final inspection
After 20 Minutes
Observation
No defective indications were observed.
Result
Accepted.
APPROVED BY
INSPECTED BY
(Signature of Inspection Authority)
Arun kr. Tiwari M.L Ghamandi (Q.C Engr.) (Q.C Head)