DOOSAN ŠKODA POWER IN NPP PROJECTS
Transcript of DOOSAN ŠKODA POWER IN NPP PROJECTS
DOOSAN ŠKODA POWER IN NPP PROJECTS
JADERNÉ DNY 2021
Luboš Prchlík
16.9.2021
Steam Turbine OEM with over 100 years of history
HISTORIC MILESTONES OF DOOSAN SKODA POWER S.R.O
1932 1976 2003 2020
1977
1904
First 23MW
Reheating
220MW
Nuclear
1,000MW
Nuclear
210MW
WtE
500MW
Thermal
270MW
P&P
2009
110MW
WtE
20212017
2014
299MW
Biomass
660MW
USC
320MW
CCPP
2
Green/
Renewable
Clean
Conventional
Coal
Oil
Gas
Nuclear
H2
Solar
Air
WtE
Biomass
Hydro
Geothermal
Skoda is a leading turbomachinery expert with unrivalled experience in turbomachinery
dynamics, and the ability to address all types of energy sources
Energy Source Coverage by Primary Energy Sources
FUNDAMENTAL EXPERTISE IN TURBO MACHINERY
Utility
Customers’ Market Sectors
IPP
Municipality
Waste to
Energy
Pulp & Paper
Chemical
Refinery
Steel Works
Sugar
Mining
Nuclear
Decommissioning
3
Steam Turbine / HEX Turbine Island EP/EPCRetrofit &
ModernizationAfter Service
• Industrial & utility steam turbine
• Conventional, CCPP, nuclear and renewables
• Heat Exchanges incl. condenser
• Feasibility study support
• Feasibility study support
• Turbine island EPC
- Eng’g and Procurement
- Construction management
• Service expertise for OEM & Non-OEM equipment
• Life/Performance assessments
• Life-time extension
• Uprating &Modernization
• OEM & Non-OEM Turbines
• Diagnosis & Trouble shooting
• Long Term Service
• Maintenance & Overhaul
• Repairs
4
CORE BUSINESS PORTFOLIO
GLOBAL STEAM TURBINE PROVIDER
MW
Unit
Asia
5.4 GW
52 Units
America
5.9 GW
51 Units
Africa
1.1 GW
15 Units Australia
0.04 GW
1 Unit
Middle East
1.9 GW
19 Units
Europe
36 GW
335 Units
India
2.9 GW
70 Units
Total Record Since 1960s ~ 53 GW = 543 Units (More than 141GW, 723 units including references of with DHI)
5
RARE PROVIDER OF FULL-RANGE POWER SOLUTIONS
Note: Internalized both reactive and impulsive
Full range of steam turbines from 5MW up to 1,250MW
Category Model ConfigurationSpeed
(RPM)
Steam para.
up toIndicative range of power output (MW)
Mech.
DriverDST-V
Variable
Speed
According to
request
Industrial
DST-
G10> 6,500
140 bar, 540°C
DST-
G204,000~6,500
140 bar, 540°C
Utility
DST-S10 3,000/3,600180 bar, 580°C
DST-S20 3,000/3,600270 bar, 610°C
DST-S30 3,000/3,600300 bar, 630°C
DST-NF Full speedSaturated
Steam
DST-NH Half speedSaturated
steam
~ 35MW
~ 35MW
20 ~ 65MW
30 ~ 200MW
100 ~ 700MW
200 ~ 1,100MW
200 ~ 1,200MW
700 ~ 1,250MW
6
DOOSAN ŠKODA POWER DELIVERIES FOR NPPs
BOHUNICE, Slovakia
LOVIISA, Finland
4x 256 MW
Modernization
MOCHOVCE, Slovakia
4x 220 MW
4x220 MW
DUKOVANY, ČR
8x 220 MW
TEMELÍN, ČR
2x 1100 MW
GREIFSWALD, Germany
delivery stopped in1989
4x 220 MW
7
Jaslovské Bohunice A1
• Electric power 3x 50 MWe
• Commissioning 1972
• Reactor issues 1976, 1977
• Shut down 1977
Jaslovské Bohunice V1 and V2
o V1 (4x 220MWe)
• Commercial operation 1981 / 1982
• Shut down 2006 / 2008
o V2 (4x 220MWe)
• Commercial operation 1985
• Modernization HP, LP 2009, 2010
Mochovce V1 and V2
o V1 (4x 220MWe)
• Commercial operation 1998 / 1999
• Modernization HP, LP 2020, 2021
o V2 (4x 220MWe)
• Modernization HP, LP 2011, 2012
• Commercial operation 2022, ?
DOOSAN ŠKODA POWER DELIVERIES FOR NPPs
8
Dukovany
o Unit 1, 2 (4x 220 MWe)
• Commercial operation 1985 / 1986
• Modernization LP, HP 2007/2008, 2011/2012
o Unit 3, 4 (4x 220 MWe)
• Commercial operation 1986/ 1987
• Modernization LP, HP 2005/2006, 2009/2010
Temelín
o Unit 1 (1x 1100 MWe)
• Commercial operation 2002
• Modernization HP, LP 2007, 2014
o Unit 2 (1x 1100 MWe)
• Commercial operation 2003
• Modernization HP, LP 2007, 2015
DOOSAN ŠKODA POWER DELIVERIES FOR NPPs
9
DOOSAN ŠKODA POWER DELIVERIES FOR NPPs
Greifswald (Germany)
o Units 5 - 8 (8x 220 MWe)
• Project stopped (1989)
Loviisa (Finsko)
Modernization of Turboatom Charkov turbines
o Unit 1 and 2 (4x 256 MWe)
• Modernization of HP parts (2016 – 2018)
• Modernization of LP parts to be completed
SMR NuScale
DHIC actively involved in NuScale
Offer for Fluor
6x 77 MWe
SMR R&R
Offer for Rolls Royce
1x 520 MWe
SMR MBIR
Modular Floating Power Units
10
11
MODERNIZATION OF NPP Dukovany
▪ Modernization of condensers (1999 – 2001)
▪ Modernization of LP parts (2005 – 2008)
▪ Modernization of HP parts (2009 – 2012)
11
MODERNIZATION OF NPP Temelín
12
MODERNIZATION OF NPP Temelín
Modernization of HP part +11,0 MWe
Modernization of HP part + 22,0 MWe
Reactor power increas. + 41,5 МWe
-----------------------------------------------------
Total el. power increase + 74,5 Мwe
New nominal operation point
1080,5 МWe3D optimized reaction blading
3D optimized blading
Now double flow 5 stages (orig. 4)
LAST STAGE BLADE 1220 mm
Guarantee measurement 1089,7 MWe
(winter operation over 1100MWe)
LP flow path ready for 108% reactor power
13
Main components upgraded
MODERNIZATION OF NPP Temelín
14
Doosan Škoda Power delivered complete machine hall of Ledvice USC 660MWe
Delivery scope:
• Basic and detail design including
foundation
• Turbine design, delivery and installation
• Auxiliary equipment delivery
• Complete equipment and piping
installation
• Commissioning and training
Similar scope applicable to new nuclear source Dukovany
DSPW EXTENDED SCOPE DELIVERY
15
NEW NUCLEAR SOURCE
16
A. Upgraded 3000rpm steam turbogenerator
• Configuration of 1100MW Temelín
B. 1500rpm steam turbogenerator
• Both solutions prepared in specific options
• Based on reactor type
• Based on specific requirements (cooling water, CHP, part load operation
requirements)
• Both solutions enable state of the art block efficiency of 37,9% to 38,3%
NEW NUCLEAR SOURCE SOLUTION
17
A. „FULL SPEED“ 3000RPM TURBOGENERATOR
Turbine cross section
3D model o machine hall
• Experience from 1100MW Temelín
• Nearly identical LP casing/rotor solution to running
PP Počerady and Ledvice
• Manufacturing experience and transportability
• Service and LTSA reference
18
• Technically less sophisticated solution
• Complicated transport
• Manufacturing readiness with specific upgrades (lathe, crane, balancing)
• Technological readiness based verified scaled modules
Turbine cross section HP and 2x LP
B. „HALF SPEED“ 1500RPM TURBOGENERATOR
Turbine cross section HP and 3x LP
19
More information needed?
Please contact: [email protected]
Please visit : http://www.doosanskodapower.com/en/
Please watch: https://www.youtube.com/watch?v=kePRnUMEqmQ
Thank you for your attention.
Doosan Škoda Power - 50 years experience in Nuclear Power Plants