American Ultraviolet®
Door Barrier (DB) Germicidal FixturesDoor Barrier (DB) Germicidal Fixtures
DB-36DB-36
American Ultraviolet Door
Barrier Germicidal Fixtures
create a curtain of germicidal ultraviolet rays
that effectively control the air-borne transmission
of microorganisms between areas.
Applications
The DB Series con nes germicidal energy to a narrow beam,
providing coverage within an average three-foot doorway. Wider
openings can be equipped with two or more units mounted
in tandem above the opening. Beam width and depth are
further controlled with deep louvers that create a powerful,
concentrated curtain of germicidal UV energy, resulting in
maximum UVC output and increased personnel safety. Beam width
and depth can be enlarged to control lamp/ oor/distance ratio and create a
balanced germicidal-fungicidal barrier from xture to oor. Lamp and louver are
easily removable for maintenance and lamp replacement does not require xture
disassembly or removal of xture from mounting.
Bene ts
• Designed to mount over doorways
• Deep louvers direct energy straight down
• Protect critical areas
• Multiple units can be used on top, and sides, of doorways for extremely
critical areas
• Component of UVC Operating Room Equipment “Package” (see back)
Ampule Filling
Autopsy Room
Animal Research
Bakery
Biology Lab
Bottling Plant
Brewery
Chemistry Lab
Contagion Ward
Cytology Lab
Cystoscopy Room
Delivery Room
Doctors Of ce
Drug/Cosmetic Manufacturing
Food Processing
Kennel
Microbiology Lab
Nursery
Nursing Home
Operating Room
Pathology Lab
Pediatric Wards
Pet Shop
Research
Sterile Packaging
Syrup Room
Veterinary Hospitals
Zoo
®
®
American Ultraviolet Barrera Germicida en PuertasCrea una cortina de rayos Ultravioleta germicidas que controlan con efectividad la transmisión de microrganismos llevados por el aire entre cuartos o áreas de contagio.
Aplicaciones
Llenado de AmpolletasSalas de AutopsiaInvestigación AnimalPanaderíaLaboratorios de BiologíaEmbotelladorasCerveceríaLaboratorios QuímicosSalas de ContagioLaboratorio de CitologíaSala de CistoscopiaSala de partosOficina MédicasPlantas de Cosméticos y Farmacéuticas
Beneficios
• Diseño para ser montada sobre las puertas• Persianas (Rejillas las cuales dirigen la luz y la mantienen en forma vertical
iluminando el área bajo la puerta)• Protección en áreas críticas• Múltiples unidades pueden ser instaladas sobre la puerta ó en los costados para
áreas extremadamente críticas• El equipo DB es un componente utilizado también en nuestro Sistema UVC
para cuartos de cirugías como parte del paquete UVC Equipo para Quirófanos.
Plantas de AlimentosPerrerasLaboratorio de MicrobiologíaViverosAsiloQuirófanosLaboratorio de PatologíaSala de PediátricaTiendas de MascotasInvestigación MédicaÁrea de Empaques EstérilesCuarto de JarabesHospitalesClínicasVeterinariasÁreas Médicas en Zoológicos
Door Barrier (DBN) Equipo Germicida en Puertas
DB-36
SE
RIE
S D
B D
E A
UV
®
®
®
®
R
American Ultraviolet®
Door Barrier (DB) Germicidal FixturesDoor Barrier (DB) Germicidal Fixtures
DB-36DB-36
American Ultraviolet Door
Barrier Germicidal Fixtures
create a curtain of germicidal ultraviolet rays
that effectively control the air-borne transmission
of microorganisms between areas.
Applications
The DB Series con nes germicidal energy to a narrow beam,
providing coverage within an average three-foot doorway. Wider
openings can be equipped with two or more units mounted
in tandem above the opening. Beam width and depth are
further controlled with deep louvers that create a powerful,
concentrated curtain of germicidal UV energy, resulting in
maximum UVC output and increased personnel safety. Beam width
and depth can be enlarged to control lamp/ oor/distance ratio and create a
balanced germicidal-fungicidal barrier from xture to oor. Lamp and louver are
easily removable for maintenance and lamp replacement does not require xture
disassembly or removal of xture from mounting.
Bene ts
• Designed to mount over doorways
• Deep louvers direct energy straight down
• Protect critical areas
• Multiple units can be used on top, and sides, of doorways for extremely
critical areas
• Component of UVC Operating Room Equipment “Package” (see back)
Ampule Filling
Autopsy Room
Animal Research
Bakery
Biology Lab
Bottling Plant
Brewery
Chemistry Lab
Contagion Ward
Cytology Lab
Cystoscopy Room
Delivery Room
Doctors Of ce
Drug/Cosmetic Manufacturing
Food Processing
Kennel
Microbiology Lab
Nursery
Nursing Home
Operating Room
Pathology Lab
Pediatric Wards
Pet Shop
Research
Sterile Packaging
Syrup Room
Veterinary Hospitals
Zoo
®
®
La Serie DB confina la energía germicida en una viga de luz estrecha con una cobertura promedio de 3 pies con respecto a la puerta. Aberturas más amplias pueden ser equipadas con dos o más
unidades montados en un tándem sobre la abertura. La profundidad y el ancho de esta viga de luz son controladas con rejillas profun-das que crean una poderosa y concentrada cortina de energía UV
dando como resultado una máxima salida de UVC e incrementando la seguridad del personal. El ancho y profundidad de la viga puede aumentar el
control de la lámpara/piso/distancia y crear una barrera fungicida-germicida balanceada con fijación al piso. La lámpara y persiana son fáciles de remover y dar mantenimiento, y el reemplazo de una lámpara no requiere desmontaje ni desmontar los accesorios.
AU
V D
B S
ER
IES
Door Barrier Germicidal Fixtures
®
www.auvhvac.com
212 South Mt. Zion Road • Lebanon, IN 46052
(765) 483-9514 • (800) 288-9288
Fax: (765) 483-9525
Represented by:
Factors are presented for American Ultraviolet xtures only and American Ultraviolet reserves the right to alter dimensions for design and ef ciency improvement without prior notice.
Prolonged, direct exposure to UVC light can cause temporary skin redness and eye irritation, but does not cause skin cancer or cataracts. American Ultraviolet systems are designed with safety in mind and, when properly installed by a professional contractor, do not allow exposure to UV irradiation and allow for safe operation and maintenance. DB 0809/5M
DB-36 SERIES SPECIFICATIONS
DB-36 Series Germicidal Fixtures from American Ultraviolet are
constructed of hospital grade stainless steel. They are 7” long and
4” deep and come complete with an 8’ service cord and pull chain
switch. Effective lamp life is rated for 12,000 hours. Ready surface
installation is possible with “keyhole” slots and additional screw
holes in the mounting place on back. Louvers can be easily removed
for lamp maintenance while xtures remain in place.
MOUNTING TEMPLATE
DB-36 ELECTRICAL CHARACTERISTICS
110-277V/50 or 60Hz
420mA Transformer
Lamp Watts: 39
INSTALLATION
Normal Contamination Area
Provides in excess of 170 microwatts
per square cm. at 3’ level and 30
microwatts per square cm. at oor
level (7’ high)
Critical Areas
Exceeds government requirement of
250 microwatts per square cm. at 3’
level, door center
PERSONNEL PROTECTION
As personnel will normally pass through the ultraviolet radiation
beam in a matter of less than a second, no protective clothing or
equipment is required. Personnel should not look directly into
the Door Barrier xture. Always turn the power off before
cleaning or re-lamping.
Ask about our Complete UVC Operating Room Equipment “Package”
UVC Operating Room Equipment “Package”
TB FixtureDoor Barrier Fixtures
Safety Equipment
Variable
Transformers
(Variac)Training
Radiometer
Direct Surface-Mounted
Fixtures (ceiling mounted)
15” 15”
Center Line 7/8” Electrical K-O
11/8”
11/8”
Keyhole Slots
C E I L I N G
WALL
DB-36Side View
2
3
4
5
6
7
F L O O R
269
171
87
57
39
30
DOOR
AREA
Max. Beam Depth 14”
Ger
mic
idal
ult
ravio
let
253.7
nm
mic
row
atts
per
squar
e ce
nti
met
er-c
ente
r of
bea
m
Dis
tance
(fe
et)
from
x
ture
RADIATION DISTRIBUTION (Cross Section View)DB Barrera Germicida en Puertas
DISTRIBUCIÓN DE ENERGÍA (vista transversal)SE
RIE
S D
B D
E A
UV
DB-36 ESPECIFICACIONESLas series DB-36 germicidas de American Ultraviolet son fabrica-dos en acero inoxidable grado hospitalario. Dimensiones: 7 pies de longitud y 4” de ancho incluyen cable toma corriente de 8 pies de longitud y cadena interruptora para el encendido y apagado. La vida de la lámpara es 12,000 horas. Lista para instalación de super-ficie posible con perforaciones y huecos para tornillos adicionales. Las rejillas se pueden quitar fácilmente.
DB-36 CARACTERÍSTICAS ELÉCTRICAS10-277V/50 or 60Hz420mA TransformadorLámpara Watts: 39
INSTALACIONArea contaminación NormalProporciona en exceso 170 micro-wattspor cm² a 3 pies de altura y 30 microwatts por cm² a una altura de 7 pies del piso a la unidadÁreas de Contaminación CríticaExcede los requerimientos gubernamentales de 250 microwatts per cm² a 3 pies del centro de la puerta
PROTECCIÓN PERSONALAl momento que el personal cruza por debajo de la viga de luz, en menos de un segundo, no se requiere ni equipo ni ropa protectora. Sin embargo el personal no debe mirar directamente a la luz; Siempre apague el equipo antes de reemplazar o limpiar la lámpara.
AU
V D
B S
ER
IES
Door Barrier Germicidal Fixtures
®
www.auvhvac.com
212 South Mt. Zion Road • Lebanon, IN 46052
(765) 483-9514 • (800) 288-9288
Fax: (765) 483-9525
Represented by:
Factors are presented for American Ultraviolet xtures only and American Ultraviolet reserves the right to alter dimensions for design and ef ciency improvement without prior notice.
Prolonged, direct exposure to UVC light can cause temporary skin redness and eye irritation, but does not cause skin cancer or cataracts. American Ultraviolet systems are designed with safety in mind and, when properly installed by a professional contractor, do not allow exposure to UV irradiation and allow for safe operation and maintenance. DB 0809/5M
DB-36 SERIES SPECIFICATIONS
DB-36 Series Germicidal Fixtures from American Ultraviolet are
constructed of hospital grade stainless steel. They are 7” long and
4” deep and come complete with an 8’ service cord and pull chain
switch. Effective lamp life is rated for 12,000 hours. Ready surface
installation is possible with “keyhole” slots and additional screw
holes in the mounting place on back. Louvers can be easily removed
for lamp maintenance while xtures remain in place.
MOUNTING TEMPLATE
DB-36 ELECTRICAL CHARACTERISTICS
110-277V/50 or 60Hz
420mA Transformer
Lamp Watts: 39
INSTALLATION
Normal Contamination Area
Provides in excess of 170 microwatts
per square cm. at 3’ level and 30
microwatts per square cm. at oor
level (7’ high)
Critical Areas
Exceeds government requirement of
250 microwatts per square cm. at 3’
level, door center
PERSONNEL PROTECTION
As personnel will normally pass through the ultraviolet radiation
beam in a matter of less than a second, no protective clothing or
equipment is required. Personnel should not look directly into
the Door Barrier xture. Always turn the power off before
cleaning or re-lamping.
Ask about our Complete UVC Operating Room Equipment “Package”
UVC Operating Room Equipment “Package”
TB FixtureDoor Barrier Fixtures
Safety Equipment
Variable
Transformers
(Variac)Training
Radiometer
Direct Surface-Mounted
Fixtures (ceiling mounted)
15” 15”
Center Line 7/8” Electrical K-O
11/8”
11/8”
Keyhole Slots
C E I L I N G
WALL
DB-36Side View
2
3
4
5
6
7
F L O O R
269
171
87
57
39
30
DOOR
AREA
Max. Beam Depth 14”
Ger
mic
idal
ult
ravio
let
253.7
nm
mic
row
atts
per
squar
e ce
nti
met
er-c
ente
r of
bea
m
Dis
tance
(fe
et)
from
x
ture
RADIATION DISTRIBUTION (Cross Section View)
PLANTILLA PARA INSTALACIÓN
Línea Central 7/8” Electrico K-O
Perforaciones de montaje
T E C H O
P I S O
AREA
DE
PUERT
Emis
or l
ultra
viol
eta
253.
7 nm
mic
row
atts
Porc
entím
etro
2 d
e vi
ga d
e lu
z
Dis
tanc
iaen
en P
ies
DB-36 Vista lateral
Max.viga de luzProfundidad 14”
269 2
171 3
87 4
57 5
39 6
30 7
“ Paquete” del Equipo UV para QuirófanosPregúnte sobre nuestro paquete complejo de equipo
para quirófanos
Elemento TB
Equipo de Seguridad
Entrenamiento
?
Radíometro
Elementos Montados de Superficie (Montado en techo)
Representado por:
Elementos de Barrera en
Puerta
www.auvhvac.com212 South Mt. Zion Road • Lebanon, IN 46052
(765) 483-9514 • (800) 288-9288Fax: (765) 483-9525
Desde 1960. Es todo lo que racemes.
Los factores se enumeran solo para elementos de American Ultraviolet y American Ultraviolet se reserva el derecho de cambiar las dimensiones por el diseño y la mejora de la eficacia sin aviso previo.
La exposición directa prolongada de luz UVC puede provocar enrojecimiento en la piel e irritación en los ojos de forma temporal, pero no provoca cáncer ni cataratas. Los sistemas de American Ultraviolet están diseñados tomando en cuenta la seguridad e instalados por un contratista profesional, sin permitir exposición a la irradiación UV y permitiendo un mantenimiento y manejo seguro.