DOE Data Center Energy Efficiency Program

23
1 DOE Data Center Energy Efficiency Program Paul Scheihing U.S. Department of Energy Energy Efficiency and Renewable Energy February, 2009

Transcript of DOE Data Center Energy Efficiency Program

Page 1: DOE Data Center Energy Efficiency Program

1

DOE Data Center Energy Efficiency Program

Paul ScheihingU.S. Department of Energy Energy Efficiency and Renewable Energy

February, 2009

Page 2: DOE Data Center Energy Efficiency Program

2

DOE Industrial Technologies ProgramWorking to improve the energy efficiency of U.S. industryU.S. industry consumes 32 quadrillion Btu per year -- almost 1/3 of all energy used in

the nationPartnerships with energy-intensive industries are key to ITP’s success:

• 5 quads of energy savings, 86 MMTCE reduction

Save Energy Now is working to reduce industrial energy intensity 25% by 2017

Page 3: DOE Data Center Energy Efficiency Program

3

Data Centers are INFORMATION FACTORIES…Resembling large

industrial facilities

Page 4: DOE Data Center Energy Efficiency Program

4

Containing Specialized Equipment

Page 5: DOE Data Center Energy Efficiency Program

5

Save Energy Now: Products & ServicesTools

Training

Information

Assessments

• Website• Information Center• Tip Sheets• Case studies• Webcasts

• Process Heating• Steam Systems• Plant Energy Profiler• Motors & Pumps• Fans

• Basic• Advanced• Qualified Specialist

• Energy Savings Assessments

• Industrial Assessment Centers

Page 6: DOE Data Center Energy Efficiency Program

6

Energy Issues Abound• Data centers are an important and growing market• Data centers are energy intensive

Server racks now designed for more than 25+ kW

Typical facility ~ 1MW, can be > 20 MW

Cost of electricity approaching capital cost of IT equipment

1.5% of all electricity in the U.S. in 2006 ($4.5 Billion)

Growing at 12% per year (will double in 5 years)

Power and cooling constraints in existing facilities

Utility distribution constraints• Currently no consistent metric to measure output• Perverse incentives -- IT and facilities costs separate

Page 7: DOE Data Center Energy Efficiency Program

7

7

Data Center Energy Efficiency = 15% (or less)

100 Units Source Energy

Typical Data Center Energy End Use

Server Load /Computing Operations

Cooling Equipment

Power Conversions& Distribution

33 Units Delivered

35 UnitsPower Generation

(Energy Efficiency = Useful computation / Total Source Energy)

Presenter
Presentation Notes
Details of energy use in data centers: Server Load/ Computing Operations Cooling equipment (air conditioners, fans, humidifiers, pumps) Power distribution equipment (transformers, uninterruptible power supplies, AC/DC inverters, wiring)
Page 8: DOE Data Center Energy Efficiency Program

8

Potential Savings

• 20-40% savings typically possible• Aggressive strategies – better than

50% savings• Extend life and capacity of existing

infrastructure• Save Energy Now has developed

tools to:

Estimate where energy is going

How use compares to others

Identify savings opportunities

Page 9: DOE Data Center Energy Efficiency Program

9

Server Load/ Computing Operations

Cooling Equipment

Power Conversion & Distribution

Alternative Power

Generation

• High voltage distribution• High efficiency UPS systems• Efficient redundancy strategies• Use of DC power

• Server innovation• Virtualization• High efficiency

power supplies• Load management

• Better air management• Move to liquid cooling• Optimized chilled-water plants• Use of free cooling• Heat recovery

• On-site generation Including fuel cells and renewable sources

• CHP applications(Waste heat for cooling)

Energy Efficiency Opportunities

Presenter
Presentation Notes
IT Opportunities Power supply efficiency Standby/sleep power modes IT equipment fans Virtualization Load shifting Memory management and efficiency Cooling Opportunities Air Management Free Cooling – air or water Environmental conditions Centralized Air Handlers Low Pressure Drop Systems Fan Efficiency Cooling Plant Optimization Direct Liquid Cooling Right sizing/redundancy Heat recovery Building envelope Electrical Opportunities UPS and transformer efficiency High voltage distribution Use of DC power Right sizing/redundancy Lighting – efficiency and controls Standby generation On-site generation Premium efficiency motors
Page 10: DOE Data Center Energy Efficiency Program

10

Data Center Performance Varies in Cooling and Power Conversion

Typical DCiE (Data Center Infrastructure Efficiency) < 0.5• IT electrical and cooling systems are far from optimized • Less than half of the energy is for the servers

Typical Practice DCiE < 0.5

Better Practice DCiE = 0.7

IT Energy

Infrastructure

IT Energy

Infrastructure

Infrastructure

IT Energy

Best Practice DCiE = 0.85

DCiEData Center Infrastructure Efficiency

Energy for IT Equipment

Total Energy for Data Center

DCiE =

Page 11: DOE Data Center Energy Efficiency Program

11

DC Pro tool 2008 results• Over 1,000 people have

registered to use tool• 15 companies beta tested,

including 11 Green Grid companies

• Companies using tool in procurement specs and energy management team planning

Page 12: DOE Data Center Energy Efficiency Program

12

Save Energy Now On-line profiling tool: “Data Center Pro”

OUTPUTSOverall picture of

energy use and efficiency

End-use breakout

Potential areas for energy efficiency improvement

Overall energy use reduction potential

INPUTS

Description

Utility bill data

System information

IT

Cooling

Power

On-site gen

Presenter
Presentation Notes
Now that I’ve discussed how the PEP tool fits into our tool strategy, I want to take you through a brief overview of the PEP Tool. The PEP tool is a tool that takes a plant-wide approach to energy savings and looks at both equipment efficiency and operation practices to identify savings opportunities. Users input plant data that includes : equipment information that describes the plant’s operation and production, energy costs and usage from monthly fuel and electric bills as well as energy generation and exportation information. operation practices information The PEP Tool uses this data to: provide plant-wide energy maps for electricity, fuel, & steam to describe the plant’s energy flow and usage. identify where energy efficiency opportunities exist give the user an idea of the magnitude of the savings associated with these opportunities compare the plant’s practices to industry recognized best practices
Page 13: DOE Data Center Energy Efficiency Program

13

2008 Case Study Results

• Lucasfilm and Verizon case studies with potential cost savings identified of $343,000 and $181,000 per year, respectively

• Additional case studies desired

Page 14: DOE Data Center Energy Efficiency Program

14

Data Center Overview• Located at the Presidio of San Francisco National Park• 23-acre facility/13,500 square feet (data center)• Houses a render farm (cluster of computers that work to

process digital images), file servers, and storage systems• More than 4,300 processors• Cooled by a central chilled water plant serving the Lucasfilm

campus• Receives back-up power through UPS systems

Lucasfilms Case Study

Page 15: DOE Data Center Energy Efficiency Program

15

Case Study: Lucasfilms Ltd. (cont’d)Recommended Solutions and cost savings

• Remove redundant UPS systems ($12,000/year)

• Turn servers off during downtime ($30,000/year)

• Stage chillers to maintain high load factor ($10,000/year)

• Operate UPS in switched by-pass mode ($98,000/year)

• Improve air flow ($89,000/year)• Implement water-side economizer

($103,000/year)• Install lighting controls

($1,000/year)

Estimated Savings and Payback• Cost Savings: $343,000• Energy Savings: 3,109,200 kWh• Implementation costs: $429,500• Payback: 1.2 Years

Page 16: DOE Data Center Energy Efficiency Program

16

2011 goal is 10% energy savings overall in U.S. data center– 10.7 billion kWh– Equivalent to electricity consumed by 1 million typical U.S. households– Reduces greenhouse gas emissions by 6.5 million metrics tons of CO2 per year

DOE-Green Grid Goal for Energy Savings

Green Grid - DOE Energy Savings Goal; 10.7 billion kWh/yr by 2011

Presenter
Presentation Notes
Source: “Report to Congress on Server and Data Center Energy Efficiency Public Law 109-431” US EPA, August 2, 2007
Page 17: DOE Data Center Energy Efficiency Program

17

Federal Energy Management Program

• Best practices showcased at Federal data centers

• Pilot adoption of Best-in-Class guidelines at Federal data centers

• Adoption of to-be-developed industry standard for Best-in-Class at newly constructed Federal data centers

EPA• Metrics• Server performance

rating & ENERGY STAR label• Data center ENERGY STAR

performance benchmarking

Industrial Technologies Program• DC Pro tool suite & training• Metrics & energy baselining• Qualified specialists• Case studies• Certification of continual

improvement• Recognition of high energy savers• Best practice information & training• Best-in-Class guidelines• R&D - technology development

Industry

• Tools• Metrics• Training• Best practice information• Best-in-Class guidelines• IT work productivity standard

Page 18: DOE Data Center Energy Efficiency Program

18

2008 Activity• Tools and Assessment Protocols

- DC Pro tool v1.0 released- Electrical assessment tool beta released- IT module initiated with Green Grid- Air management assessment tool alpha released

• HVAC Tool – in development• Training

- Pilot trainings (5)- Developing joint training with ASHRAE and Green Grid

Page 19: DOE Data Center Energy Efficiency Program

19

Products• DC Pro tool• Assessment

protocols• Training curriculum• Case studies• Best practices• Best-in-Class

guidelines• Technology R&D

and demonstrations

Market Delivery • 200 Qualified

Specialists• Suppliers• Engineering

firms• Utilities• Associations

and technical societies

Data Center Results • 10 billion kWh per

year saved• 3,000 people trained

on tools and assessment protocols

• 1,500 data centers improve energy efficiency > 25%

• 200 data centers improve energy efficiency >50%

By 2011

Page 20: DOE Data Center Energy Efficiency Program

20

2009 Activity• Tools and Assessment Protocols

- Improve DC Pro tool- IT module released- Air management released- HVAC tool initiated

• Training- ASHRAE-Green Grid-DOE pilot trainings- Hold data center trainings at multiple events

• Develop and pilot Qualified Specialist program• Develop R&D program

Page 21: DOE Data Center Energy Efficiency Program

21

Calls to Action

21

• More case studies – especially data centers improving more than 25%

• Use DC Pro tools and provide feedback

• Staff and customers participate in training workshops

• Staff become qualified specialists

• Participate in potential Federal data center technology demonstration program

Presenter
Presentation Notes
Let’s take a deeper look inside a data center to see where the energy actually goes.
Page 22: DOE Data Center Energy Efficiency Program

22

DOE Data Center program

Paul Scheihing

www.eere.energy.gov/industry

www.eere.energy.gov/datacenters/

[email protected]

202-586-7234

Information Tech. R&D program

Gideon Varga

www.eere.energy.gov/industry

[email protected]

202-586-0082

Page 23: DOE Data Center Energy Efficiency Program

23

Links to Get Started:DOE Website: Sign up to stay up to date on new developments www.eere.energy.gov/datacenters

Lawrence Berkeley National Laboratory (LBNL) http://hightech.lbl.gov/datacenters.html

LBNL Best Practices Guidelines (cooling, power, IT systems) http://hightech.lbl.gov/datacenters-bpg.html

ASHRAE Data Center technical guidebooks http://tc99.ashraetcs.org/

The Green Grid Association – White papers on metrics http://www.thegreengrid.org/gg_content/

Energy Star® Program http://www.energystar.gov/index.cfm?c=prod_development.server_efficiency

Uptime Institute white papers www.uptimeinstitute.org