DL389B - Image and Video Upload, Storage, Optimization and CDN

16
Hi-NCV-Lo MFD °F °C μA CAT Ill 600V 400A MAX/MIN HOLD Hz / Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V INSTRUCTION MANUAL ENGLISH DL389B TRMS Dual Display Clamp Meter 1-800-547-5740 www.ueitest.com • email: [email protected] 1000V CAT II 600V CAT III

Transcript of DL389B - Image and Video Upload, Storage, Optimization and CDN

Page 1: DL389B - Image and Video Upload, Storage, Optimization and CDN

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

INSTRUCTION MANUALENGLISH

DL389B

TRMS Dual Display Clamp Meter

1-800-547-5740www.ueitest.com • email: [email protected]

1000VCAT II

600VCAT III

Page 2: DL389B - Image and Video Upload, Storage, Optimization and CDN

TABLE OF CONTENTS

FUNCTION .............................................................................................3

FEATURES .............................................................................................3

GENERAL SPECIFICATIONS .............................................................3

IMPORTANT SAFETY WARNINGS ................................................. 4

SYMBOLS .............................................................................................5

CATEGORY DEFINITIONS ...................................................................5

OVERVIEW ..................................................................................... 6 - 7

FCC IC INFORMATION .........................................................................7

OPERATING INSTRUCTIONS AC/DC Voltage 750Vac/1000Vdc ............................................ 8

Resistance ...................................................................................9

Continuity ....................................................................................9

Diode ..........................................................................................10

AC Amp <400A ....................................................................... 11 Capacitance (MFD) ................................................................ 11

AC/DC Low Amps .....................................................................12

Non-Contact Voltage Hi-Lo ......................................................13

Temperature C°/F° .....................................................................13

Frequency (Hz) / Duty Cycle Measurements ...........................14

Test Lead Notes .........................................................................15

Battery Replacement ................................................................15

WARRANTY .........................................................................................16

DISPOSAL ...........................................................................................16

CLEANING ...........................................................................................16

STORAGE ...........................................................................................16

Page 3: DL389B - Image and Video Upload, Storage, Optimization and CDN

3

FUNCTION

• True RMS• 750V AC• 1000V DC• 400A AC • Temperature: -22°F to 752°F (-30°C to 400°C)• Capacitance: 4000µF

• AC/DC low amps: 2000µA• Frequency 199.9kHz• Duty cycle: 99%• Resistance: 40MΩ• Hi-NCV-Lo • Diode Test• Continuity

FEATURES

• Dual Display• Input Jack Locks• Worklight• Back Light• Auto/Manual Ranging• Min/Max• Test Lead Storage

• Magnetic Mount• User Temperature Calibration• Auto Power Off • Degree °F or °C• Low Battery Indicator• Test Lead Holder on Clamp

GENERAL SPECIFICATIONS

• Operating Temperature: 32° to 104°F • Storage Temperature: -4° to 140°F• Operating Humidity: <80% Max• Operating Altitude: 6,562 ft (2000m)• Pollution Degree: 2• Display: 4,000 Count• Back Light: YES• Refresh Rate: 3 per Sec.• Over-range: “OL” is displayed• Dimensions: 8.70 in x 3.23 in x 1.50 in• Item Weight: 11.1 oz • Calibration: Recommended Annually• CAT Rating: CATIII 600V/CATll 1000V• Certifications: CATlll 600V/CATII 1000V, cETLus UL61010-1:2012• Battery Type: (AAA) 2• Includes: Test leads (ATL55), K-Type temperature probe, 2 (AAA) batteries, Manual, Pouch• Accuracy: ± (% of reading + # of least significant digits)

Page 4: DL389B - Image and Video Upload, Storage, Optimization and CDN

4

IMPORTANT SAFETY WARNINGS WARNING

Read entire safety notes section regarding potential hazard and proper instructions before using this meter. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage this instrument.

WARNINGTo ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injuries or death.

WARNING• Before each use, verify meter operation by measuring a known voltage or current.• Never use the meter on a circuit with voltages that exceed the category based rating of this meter. • Do not use this meter during electrical storms or in wet weather.• Do not use the meter or test leads if they appear damaged. • Ensure meter leads are fully seated and keep fingers away from the metal probe contact when making measurements. Always grip the leads behind the finger guards molded into the probe.• Do not open the meter to replace batteries while the probes are connected. • Use caution when working with voltages above 60V DC or 25V AC RMS. Such voltages pose shock hazards.• To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears. • Unless measuring voltage or current, shut off and lockout power before measuring resistance or capacitance.• Always adhere to national and local safety codes. Use proper personal protective equipment (PPE) to prevent shock and arc blast injury where hazardous live conductors are exposed.• Always turn off power to a circuit or assembly under test before cutting, unsoldering or breaking the current path. Even small amounts of current can be dangerous.• Always disconnect the live test lead before disconnecting the common test lead from the circuit. • In the event of electrical shock, ALWAYS bring the victim to the emergency room for evaluation, regardless of victim’s apparent recovery. Electrical shock can cause unstable heart rhythms that may need medical attention.• If any of the following occurs during testing, turn off the power source to the circuit being tested: arcing, flame, smoke, extreme heat, smell of burning materials or discoloration melting of components.

WARNINGHigher voltages and currents require greater awareness of physical safety hazards. Before connecting the test leads, turn off power to the circuit under test, set meter to the desired function and range, connect the test leads to the meter first, then connect to the circuit under test. Reapply power. If an erroneous reading is observed, disconnect power immediately and recheck all settings and connections.

WARNINGThis meter is designed for trade professionals who are familiar with the hazards of their trade. Observe all recommended safety procedures that include proper lock-out utilization and use of personal protective equipment that includes safety glasses, gloves and flame resistant clothing.

Page 5: DL389B - Image and Video Upload, Storage, Optimization and CDN

5

SYMBOLS

AC (Alternating Current) DC (Direct Current)

Negative DC AC/DC Voltage or Current

Auto-Ranging Overload: Range Exceeded

Auto Power Off Active Non-Contact Voltage

Low Battery Hold/Capture Value

Minimum Measured Value Displayed

Maximum Measured Value Displayed

Duty Cycle Hertz/Frequency

Voltage Amperage

Ohms/Resistance Diode

Capacitance Mode In Nanofarads or Microfarads nF Nanofarad

Microfarad Microamps

Degrees Fahrenheit Degrees Celsius

Continuity Mega (X106 or 1,000,000)

Milli (X10-3 or 0.001) Kilo (X103 or 1,000)

Nano (X10-9 or 0.000000001) Micro (X10-6 or 0.000001)

Warning or Caution Ground

Dangerous Levels Double Insulation (Protection To Class II)

Safe for Disconnect from Live Conductors

CATEGORY RATING DEFINITIONS

Measurement Category

Short-Circuit (typical) kAa

Location in the building installation

II < 10 Circuits connected to mains socket outlets and similar points in the MAINS installation

III < 50 Mains distributions parts of the building

IV > 50 Source of the mains installation in the building

Page 6: DL389B - Image and Video Upload, Storage, Optimization and CDN

6

A. Wire Separation Tab/NCV Sensor: Use to isolate an individual wire from a bundle for testing. NCV sensor detects live voltage.B. Clamp: Measure inductive AC current. Opens to 1.25” (32mm)C. Conductor Alignment Marks: Use to aid the visual alignment of a conductor when measuring inductive amperage. Greatest accuracy is achieved when the conductor inside the clamp is centered at the intersection of these marks.D. Test Lead Holder: Used for hand-free use of the test probes.E. Worklight: Lights clamp area in dark work environments.F. Category Max Indicator: Maximum CAT Rating for Clamp/jaw.G. Hand Guide: Used as a point of reference for the operator’s safety.H. Clamp Lever: Opens and closes current clamp jaw. NOTE: The clamp uses a high-tension spring to close the jaw. Do not allow fingers or objects to become pinched in the base as the jaws close. I. Hi-NCV-Lo Alert Light: Indicates voltage when in NCV mode.J. Hi-NCV-Lo Button: 24V to 600V range • Press and hold for NCV detectionK. Range Button: • Press repeatedly to cycle through manual ranges. • Press and hold to return to auto ranging mode. • AT is displayed on LCD only during auto ranging mode. • Note: Select range prior to MAX/MIN for best results. L. Max/Min Button: • Press to enter MAX/MIN mode. • Press repeatedly to alternate between Maximum and Minimum readings. • Press and hold to return to live readings. M. Hold Button: • Press to hold the reading on the display. Press again to return to live reading. • Press and hold to turn on Worklight and Back Light. Press and hold again to turn off.

E

F

H

K

O

PQ

J

M

R

U

X

Y

W

VI

OVERVIEW

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

B

C

A

D

G

LN

ST

Page 7: DL389B - Image and Video Upload, Storage, Optimization and CDN

7

N. Function Dial: Turns on meter and is used to select the function.O. Display: • High contrast backlit dual display. • AC Amps Upper display • All other readings in Lower DisplayP. Select Button: • Used to choose measurement mode from a single dial selection; AC or DC volts, continuity, diode, AC or DC low amps, ˚F or ˚C in temperature mode.Q. Thermocouple Temperature InputR. Category Max Indicator: Maximum CAT Rating for input jacks. • Multifunction input port used for measuring: AC or DC volts, resistance, continuity, diode, capacitance, AC or DC µA and temperature. • Use CATIII test leads or higherS. Hertz/Duty Cycle Button (Hz/Duty): • Press once in voltage mode to enter Hz mode • Press again to enter duty cycle mode • Press again to return to voltage modeT. Input Jack Lock: Switch to use Temperature or Test lead inputsU. Test Lead InputsV. Magnetic Mount: For hands-free work.W. Battery Cover: Easy access for replacing batteries.X. Serial NumberY. Test Lead Holders: For storing test leads when not in use.Apo: Auto power off after 30 minutes of use.

OVERVIEW (CONT.)

FCC/IC INFORMATION

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in any particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try and correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.

CAUTION Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.

This device complies with Industry Canada license - exempt RSS standard(s). Operation is subject to the following two conditions:

(1) this device may not cause interference, and(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Page 8: DL389B - Image and Video Upload, Storage, Optimization and CDN

8

WARNING

• Use CATIII rated Test leads or higher.• Do not attempt to measure more than 750V AC/1000V DC.• Do not exceed 25 volts AC or DC – RMS at either the common or Multifunction input ports as measured from earth ground.

AC Volts

Range Resolution Accuracy Overload Protection

400mV 0.1mV

± (2.0% +5 dgts) 750V RMS

4V 1mV

40V 10mV

400V 100mV

750V 1.0V

45Hz to 1kHz True RMS (crest factor <3:1)

DC Volts

Range Resolution Accuracy Overload Protection

400mV 0.1mV

± (0.5% +4 dgts) 1000V RMS

4V 1mV

40V 10mV

400V 0.1V

1000V 1V ± (0.8% + 10 dgts)

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

V

Features:

RANGE

AC/DC Voltage 750VAC/1000VDC

• Default =

• Press x1 =

Page 9: DL389B - Image and Video Upload, Storage, Optimization and CDN

9

WARNING • Do not measure resistance on a live circuit.

Range Resolution Accuracy Overload Protection

400Ω 100mΩ

± (1.0% +4 dgts) 600V RMS

4kΩ 1Ω

40kΩ 10Ω

400kΩ 100Ω

4MΩ 1kΩ

40MΩ 10kΩ ± (2.0% +4 dgts)

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

• Buzzer sounds at less than 50Ω.

WARNING• Do not measure resistance on a live circuit.

Open Circuit Voltage Overload Protection

<0.44V 600V RMS

Threshold approx. <50Ω

• Default =

• Press x1 =

Resistance: < 40MΩ

Continuity

Ω

Features:

Features:

RANGE

Page 10: DL389B - Image and Video Upload, Storage, Optimization and CDN

10

• Default =

• Press x1 =

• ‘0’ Both directions (shorted)• Forward voltage drop if forward biased.• “O.L.” if reverse biased.

Range Open Circuit V Test Current Overload Protection

2.0V <1.6V DC 0.25mA 600V RMS

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

Diode

GOOD DIODE

BAD DIODE

Forward Biasdisplays approx. voltage drop

Reverse BiasDisplays "OL"

orOpen DiodeDisplays "OL" Both directions

Features:

A

Page 11: DL389B - Image and Video Upload, Storage, Optimization and CDN

11

Range Resolution Accuracy Overload Protection

40nF 0.01nF

± (3.5% +6 dgts) 600V RMS

400nF 0.1nF

4µF 0.001µF

40µF 0.01µF

400µF 0.1µF

4000µF 1µF

Capacitance (MFD)

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

AC Amps: <400A

• Center wire in guides for best accuracy.• Opposing currents cancel (use line-splitter when necessary). Keep hands below guard when measuring high current levels.• Do not attempt to measure more than 400A AC.

Range Resolution Accuracy Overload Protection

40A 0.01A ± (2.9% +15 dgts)600V RMS

400A 0.1A ± (1.9% + 8 dgts)

45Hz to 400Hz True RMS (crest factor <3:1)

Features:

SingleConductorOnly

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

Features:

RANGE

Page 12: DL389B - Image and Video Upload, Storage, Optimization and CDN

12

WARNING • Do not attempt to measure more than 2000µA.

DC Low Amps (Test Lead Input)

Range Resolution Accuracy Overload Protection

400µA 0.01µA± (1.2% +3 dgts) 2000µA/600V RMS

2000µA 0.1µA

AC Low Amps (Test Lead Input)

Range Resolution Accuracy Overload Protection

400µA 0.01µA ± (2.0% +5 dgts) 2000µA/600V RMS

2000µA 0.1µA ±(1.5% +5 dgts)

45Hz to 400Hz True RMS (crest factor <3:1)

AC/DC Low Amps: <2000µA

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

• Default =

• Press x1 =µA

Features:

RANGE

µA

Page 13: DL389B - Image and Video Upload, Storage, Optimization and CDN

13

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

• Press and hold NCV button, move clamp meter tip near voltage source.• Non-Contact Voltage Detection is used to detect power with sensor

located in the tip of the clamp head indicates positive response with both an Audible and Visual alert.

• Do not use non contact voltage detector to determine if there is current on the wire. Detection operation could be affected by socket design, insulation thickness, type or other factors.

• Voltage indicator light may also light when voltage is present on the meter’s input jack or from an external interference such as motors, flashlights, etc.

Non-Contact Voltage Hi - Lo

NCV

NCV Sensorlocated in tip

Temperature °F/°C

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

• Default =

• Press x1 =

Features:

WARNING

Disconnect test lead probes from voltage source and meter. • Press Select button to change between Fahrenheit and Celsius.

Range Resolution Accuracy Overload Protection

-22˚ to 14˚F (-30˚ to -10˚C)

0.1˚F (0.1˚C)

± (1.0% + 5.4˚F) ± (1.0% + 3.0˚C)

30V RMS15˚ to 752˚F (-9˚ to 400˚C)

± (1.0% + 3.6˚F) ± (1.0% + 2.0˚C)

Sensor must be thermocouple type.Stated accuracy does not account for thermocouple accuracy

• “Lo” NCV light indicates voltage <120V. “Hi” NCV light indicates the presences of voltage >120V. NOTE: The worklight will turn off during NCV tests.

/

Page 14: DL389B - Image and Video Upload, Storage, Optimization and CDN

14

Use CAT III test leads or higher.

Select AC Voltage mode, press the button for Frequency and Duty Cycle modes.

Frequency

Range Resolution Accuracy Overload Protection

99.99Hz 0.01Hz

± (0.1% +4 dgts) 600V RMS

999.9Hz 0.1Hz

9.999kHz 1Hz

99.99kHz 10Hz

199.9kHz 100Hz

Minimum Frequency: 0.5Hz, DC V offset should be zero Sensitivity: > 10% of each AC volt range except 4V (>20%) range only

Duty Cycle

Range Accuracy Overload Protection

1.0 to 99.0% ± (0.2% per kHz +0.1%) +5 dgts 600V RMS

0.5Hz to 100KHz (pulswidth > 2µ sec)

Frequency (Hz) / Duty Cycle Measurements

Hi-NCV-LoMFD

°F °CµA

CAT Ill 600V 400A

MAX/MINHOLD

Hz / DutySELECTTEMP

DISCONNECT

30V MA

X

TEST LEADS

True RMSDL389B

MAX

CATll1000VCATIII600V

• Default = • Press x1 = • Press x2 = %

Features:

V

Hz/Duty

Page 15: DL389B - Image and Video Upload, Storage, Optimization and CDN

15

Test Lead NotesCATIV 600V Measurement Locations

• Ensure the test lead shield is pressed firmly in place. Failure to use the CAT IV shield increases arc-flash risk.

CATII 1000V Measurement Locations

• CAT IV shields may be removed for CAT II locations. This will allow testing on recessed conductors such as standard wall outlets. Take care not to lose the shields.

WARNING: Test lead category protections apply only to test leads and should not be confused with the meter’s specific CAT rating. Observe the maximum category protection indicated on the meter the test leads are plugged into.

4mm

18mm

4mm

18mm

Battery Replacement

• When the batteries are too low for safe operation, the Low Battery indicator will display.

• Loosen screw. Remove battery cover.• Replace the old batteries with 2 new

(AAA) batteries.• Replace the battery cover. Tighten the screw.

Page 16: DL389B - Image and Video Upload, Storage, Optimization and CDN

WARRANTY

The DL389B is warranted to be free from defects in materials and workmanship for a period of 2 years from the date of purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi’s option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warranty.

Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.

A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. Instruments out of warranty will be repaired (when repairable) for a service charge

For more information on warranty and service, contact:

www.ueitest.com • Email: [email protected]

This warranty gives you specific legal rights. You may also have other rights, which vary from state to state.

DISPOSAL

CAUTION: This symbol indicates that equipment and its accessories shall be subject to separate collection and correct disposal.

CLEANING

Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the structural components.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the instrument to return to normal operating conditions before using it.

Copyright © 2018 Kane USA. All Rights Reserved. 26069/1218