Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration...

30
ASIKO 1 ASIKO

Transcript of Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration...

Page 1: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO1

ASIKO

Page 2: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

2

Using Cooking Gas (LPG) for Refrigeration

and Cooling

Page 3: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO3

Presentation Outline

◆ Who is Asiko?

◆ Energy Transition

◆ LPG in Nigeria

◆ Cooling: A Means to Development

◆ Cooking Gas For Cooling

◆ Summary

Page 4: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Benin (Future)

Ijora DepotCoastal

Terminal

Kano Depot

Abuja Depot

Oshogbo Depot

Alagbole Depot

3x Ilorin Depot

Owerri Depot

Third Party Coastal Terminal

Gas Distribution Hubs / Depots

Gas Producers / Suppliers

Distribution / Bulk

Retail (New)

Asiko Group Current Operations

Page 5: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Asiko Typical LPG Depot

Page 6: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO6

Our Logistics

Page 7: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

An LPG Power Plant

Page 8: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

An LPG Fired Cold Room

Page 9: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO9

Presentation Outline

◆ Who is Asiko?

◆ Energy Transition

◆ LPG in Nigeria

◆ Cooling: A Means to Development

◆ Cooking Gas For Cooling

◆ Summary

Page 10: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Ene

rgy

Sup

ply

Pat

tern

LPG

Time and Degree of Economic Development

Biomass

Coal/Oil

Electricity

Natural Gas

Undeveloped Developing Developed

PP: 40322 Sec_3

Energy Transition

Page 11: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO11

Presentation Outline

◆ Who is Asiko?

◆ Energy Transition

◆ LPG in Nigeria

◆ Cooling: A Means to Development

◆ Cooking Gas For Cooling

◆ Summary

Page 12: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO12

Upcoming LPG Production in Nigeria

Page 13: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Comparative Unit Cost

(N/kWh)

0.0

30.0

20.0

10.0

50.0

40.0

100.0

90.0

80.0

70.0

60.0

Diesel LPG

Fuel Cost (N/kWh)

LPG Costs40% less

than diesel

Comparative unitcost of powerfor Diesel cf. LPG –FUEL COST ONLY:

▪ Diesel = N77/kWh

▪ LPG = N47/kWh

Page 14: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO14

Presentation Outline

◆ Who is Asiko?

◆ Energy Transition

◆ LPG in Nigeria

◆ Cooling: A Means to Development

◆ Cooking Gas For Cooling and Power

◆ Summary

Page 15: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Cooling/Cold Chain As a Means To

Development

15

◆ Allows industries maximize every part of the supply chain, and retains value at every stop until consumed. Applies to all industries

◆ A robust cold chain aids improved health (blood banks, vaccines etc.)

◆ Reduced inter-communual clashes caused by grazing

◆ Horticulture and other temperature sensitive luxury industries will thrive.

◆ Reduced food wastage; better food prices.

Page 16: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

The Cooling Conundrum Cuts Across

Diverse Industries and Professions

16

• Agriculture

• Health Care

• Information Technology

• Manufacturing

• Diary and Livestock

• Horticulture

• Restaurants and Leisure

• Logistics

Page 17: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO17

Presentation Outline

◆ Who is Asiko?

◆ Energy Transition

◆ LPG in Nigeria

◆ Cooling: A Means to Development

◆ Cooking Gas For Cooling and Power

◆ Summary

Page 18: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Asiko Approach to LPG Cooling

Vapor Absorption

Refrigeration System

• An absorption refrigerator

uses a heat source to provide

the energy needed for the

cooling process.

• VARS are often classified as

heat-driven systems. They are

used especially, when there is

a source of inexpensive

thermal energy at a

temperature of 100 to 200°C

• Cooking gas (LPG) can burns at over 300 °C, which makes it ideal for

VARS

Page 19: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

An LPG Fired Cold Room (Made in Nigeria)

Enclosed Space Cooking GasSolar Panels

Inverter System VAR System Indoor Unit

Page 20: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

The VAR System Advantage

▪ No CFC, hence environment friendly

- Uses water (R 712) as refrigerant instead of

ozone depleting Chlorofluorocarbons

▪ No noise

- No moving parts, therefore no dynamic load

- No vibration, therefore silent operation

▪ Negligible maintenance

▪ Negligible electric power

- 0.75kW for a 5RT Vs 5kW for an

electrically powered compressor unit of

same size

- Power required for only small pumps

▪ Modular Design

- Compact design; on skid Delivery

Page 21: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

LPG/Cooking Gas Cooling REFERENCES

Residencial Space Cooling

Location Lekki Lagos

Operating mode Direct Fired

Total Cooling Capacity

5RT/17.9kW

Fuel LPG

Scope Engineered equipment delivery

Delivery In service 2015

Residencial Space Coolomg

Location Banana Island

Operating mode Direct Fired

Total Cooling Capacity

10RT/35.8kW

Fuel LPG

Scope Engineered Equipment Delivery and Installation

Delivery In service 2015

Medical Space Cooling (FCC)

Location Ikoyi, Lagos

Operating mode

Direct Fired

Total Cooling Capacity

15RT/53.7kW

Fuel LPG

Scope Engineered Equipment Delivery and Installation

Delivery 2016

Page 22: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Mall Development - OPTION 1Diesel Power + Electric Cooling

Cooling

3,000kWDiesel

464 kg/hr

DIESEL POWER ELECTRIC

COOLING

Electricity

Page 23: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Mall Development - OPTION 2Gas Power + Electric Cooling

Cooling

3,000kWLP Gas

464 kg/hr

ELECTRIC

COOLING

Electricity

GAS POWER

N247m

/Annum

Savings!

Page 24: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Mall Development - OPTION 3Gas CCHP

Cooling

3,000kW

LP Gas

139 kg/hr

GAS COOLINGGAS POWER

N381m

/Annum

Savings!

Clean Waste Heat

Electricity

Page 25: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Payback (in Months)

25

17.4

6.7

0.0

2.0

4.0

6.0

8.0

10.0

12.0

14.0

16.0

18.0

20.0

Option 13 x 1250 Diesel

Option 23 x 1250 LPG

Option 32 x 750 LPG

Payback on Incremental Costs - Months

Option 1 Option 2 Option 3

Page 26: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Power Supply-Beverage Company Client(Single 3,000 kVA Gas cf. Diesel)

Power Demand

(kWh)

DieselCost

(N/kWh)

Gas Cost

(N/kWh)

CostSavings

(N/kWh)

AnnualSaving

(N)

Fuel Cost 8,352,000 47.80 21.25 26.55 221,745,600

Equipment Cost

8,352,000 10.28 18.50* (8.22) (68,653,440)

Total 58.08 39.75 18.33

Net Annual Savings

153,092,160* Capital cost amortized over 5 years

Page 27: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO

Power Supply – Mall Project Client(Single 2,400 kW Gas cf. Diesel)

Power Demand @ 75% Load

(kWh)

DieselCost

(N/kWh)

Gas Cost

(N/kWh)

CostSavings

(N/kWh)

AnnualSaving

(N)

Fuel Cost 15,120,000 47.80 21.25 26.55 401,436,000

Equipment Cost

15,120,000 10.28 18.50* (8.22) (124,286,400)

Total 58.08 39.75 18.33

Net Annual Savings

277,149,600

* Capital cost amortized over 5 years

Page 28: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKO28

Presentation Outline

◆ Who is Asiko?

◆ Energy Transition

◆ LPG in Nigeria

◆ Cooling: A Means to Development

◆ Cooking Gas For Cooling and Power

◆ Summary

Page 29: Distributed Power Project...ASIKO Asiko Approach to LPG Cooling Vapor Absorption Refrigeration System • An absorption refrigerator uses a heat source to provide the energy needed

ASIKOASIKO

Summary

29

◆ Gas in the form of LPG is readily available in Nigeria and W. Africa

◆ LPG will increasingly become the preferred fuel of choice from a cost savings and environmental point of view.

◆ Asiko has the capacity, through an un-paralleled supply and logistics network, to deliver reliable, cost saving energy and cooling projects in Nigeria & W. Africa

◆ We are committed to delivering clean, cheap gas COOLING SOLUTIONS to our clients.