The Zonri' s single break, insulator operated disconnector has been designed for both rural distribution and substation type disconnector applications and complying with IEC 60129.Rated voltage from 12kV to 36kV,rated current up to 1200A. 19 20 Three phase disconnect switch Features Technical parameters: GW58-12/24/36 outdoor MV disconnect switch are used to open an close circuit with voltage but no-load 50/60Hz,12kV up to 36kV power system, this anti-pollution type can be used in the series pollution area. Manufacture according IEC standards. Up to 36kV,900A,200kV BIL. Three phase disconnector. Porcelain and polymer type insulator. Manual and electric drivers. Accessories and relays. Test Item Rated voltage Rated current Rated frequency Rated short-time withstand current Rated short-circuit duration Main loop resistance Power frequency withstand (wet) Power frequency withstand (ydr) Lightning impulse withstand voltage. Mechanical life Unit Data kV A Hz kA s ìÙ kV kV kV Times 12 400/630 50/60 20 4 100 30 48 75 2000 24 400/630 50/60 20 4 100 65 85 125 2000 36 400/630 50/60 25 4 100 85 115 185 2000 Disconnectors

Transcript of Disconnectors - zonrielectric.com It accords with the standards of IEC62271-102 &...

Page 1: Disconnectors - zonrielectric.com It accords with the standards of IEC62271-102 & GB/T3804:3.6~40.5kV High voltage switches, IEC60694 & GB/T11022: High voltage switch apparatus and

The Zonri's single break, insulator operated disconnector has been designed for both rural distribution and

substation type disconnector applications and complying with IEC 60129.Rated voltage from 12kV to 36kV,rated

current up to 1200A.

19 20

Three phase disconnect switch

Features

Technical parameters:

GW58-12/24/36 outdoor MV disconnect switch are used to

open an close circuit with voltage but no-load 50/60Hz,12kV

up to 36kV power system, this anti-pollution type can be used

in the series pollution area.

Manufacture according IEC standards.

Up to 36kV,900A,200kV BIL.

Three phase disconnector.

Porcelain and polymer type insulator.

Manual and electric drivers.

Accessories and relays.

Test Item

Rated voltage

Rated current

Rated frequency

Rated short-time withstand current

Rated short-circuit duration

Main loop resistance

Power frequency withstand (wet)

Power frequency withstand (ydr)

Lightning impulse withstand voltage.

Mechanical life

Unit Data

kV

A

Hz

kA

s

ìÙ

kV

kV

kV

Times

12

400/630

50/60

20

4

100

30

48

75

2000

24

400/630

50/60

20

4

100

65

85

125

2000

36

400/630

50/60

25

4

100

85

115

185

2000

Disconnectors

Page 2: Disconnectors - zonrielectric.com It accords with the standards of IEC62271-102 & GB/T3804:3.6~40.5kV High voltage switches, IEC60694 & GB/T11022: High voltage switch apparatus and

21

Technical specifications

Type

Rated Voltage kV

Rated Current A

Momentany Current A

BIL kV

Short Time Withstand

Current 2S(Sym)A

GW9-15/400

15

400

40000

125

25000

GW9-15/630

15

630

40000

125

2500

GW9-15/900

15

900

40000

125

2500

15KV

Type

Rated Voltage kV

Rated Current A

Momentany Current A

BIL kV

Short Time Withstand

Current 2S(Sym)A

GW9-24/400

24

400

40000

125

25000

GW9-24/630

24

630

40000

125

2500

GW9-24/900

24

900

40000

125

2500

24KV

Type

Rated Voltage kV

Rated Current A

Momentany Current A

BIL kV

Short Time Withstand

Current 2S(Sym)A

GW9-36/400

36

400

40000

125

25000

GW9-36/630

36

630

40000

125

2500

GW9-36/900

36

900

40000

125

2500

36KV

Three phase disconnect switch

Technical specifications

Technical specifications

Page 3: Disconnectors - zonrielectric.com It accords with the standards of IEC62271-102 & GB/T3804:3.6~40.5kV High voltage switches, IEC60694 & GB/T11022: High voltage switch apparatus and

FZW33 12kV/24kV Outdoor AC vacuum type load disconnector is a new product adopts domestic existing mature load

breaker switch product ion experience and overseas advanced technology to design and manufacture. The load

breaker is composed of disconnect blade, vacuum interrupter and operation mechanism. vacuum extinguishing arc,

there are merits as strong extinguishing arc ability, reliable performance, long lifetime, small volume, no explosive danger

and no pollution to environment.

These disconnectors are suitable for powering networks of 12,24kV,to be used as a disconnecting devive of MV/LV

distribution transformers and to disconnect the MV outdoor tine.

It accords with the standards of IEC62271-102 & GB/T3804:3.6~40.5kV High voltage switches, IEC60694 &

GB/T11022: High voltage switch apparatus and control apparatus.

Vacuum Type Load Disconnector

Page 4: Disconnectors - zonrielectric.com It accords with the standards of IEC62271-102 & GB/T3804:3.6~40.5kV High voltage switches, IEC60694 & GB/T11022: High voltage switch apparatus and

Ambient condition

1. Altitude: 1000m;

2. Ambient temperature: -35 ~+50 C ;

3. Relative humidity: daily average 90%; monthly average 95%;

4. Earthquake intensity: 8 degree;

5. Applicable occasions should be free from inflammable, explosives and severe vibration.

Technical specification

No .

1

2

3

4

5

6

7

8

9

11

12

13

14

15

16

17

18

Test Item

10

Vacuum arc extinguish chamber

No .

1

2

3

4

Item

19

20

Rated voltage

Rated current

Rated frequency

Rated short-time withstand current

Rated short-circuit duration

Rated active load breaking current

Rated loop breaking current

Rated cable charging current

5% rated active load breaking current

Rated short-circuit making current

Main loop resistance

power frequency withstand voltage against the earth, between phases

power frequency withstand voltage against the isolating distance

Lightning impulse withstand voltage against the earth, between phases (peak)

Lightning impulse withstand voltage against the air gap(peak)

Mechanical life

Three phase closing asynchronous

Main contact blade pressure

Distance between electric parts and phase to earth

Rated operating force

kV

A

Hz

kA

s

A

A

A

A

kA

kV rms

kV rms

kV

kV

Times

ms

N

mm

N

12

400/630

50/60

20

4

400/630

400/630

12

31.5

50

100

40

48

75

85

10000

5

520

300

300

Unit Data

24

400/630

50/60

20

4

400/630

400/630

12

31.5

50

100

65

79

125

145

10000

5

520

600

300

Contact distance

Average breaking speed

Three phase breaking asynchronous

Three phase making asynchronous

DataUnit

mm

m/s

ms

ms

10 1

1.2 0.2

<3

<3