Direct charge measurement in Floating Gate transistors of Flash EEPROM using
Scanning Electron Microscopy
Franck Courbon, Sergei Skorobogatov Computer Laboratory, University of Cambridge, Cambridge, United Kingdom
Christopher Woods
Quo Vadis Lab, London, United Kingdom
Abstract
We present a characterization methodology for fast direct
measurement of the charge accumulated on Floating Gate (FG)
transistors of Flash EEPROM cells. Using a Scanning Electron
Microscope (SEM) in Passive Voltage Contrast (PVC) mode
we were able to distinguish between '0' and '1' bit values stored
in each memory cell. Moreover, it was possible to characterize
the remaining charge on the FG; thus making this technique
valuable for Failure Analysis applications for data retention
measurements in Flash EEPROM. The technique is at least
two orders of magnitude faster than state-of-the-art Scanning
Probe Microscopy (SPM) methods. Only a relatively simple
backside sample preparation is necessary for accessing the FG
of memory transistors. The technique presented was
successfully implemented on a 0.35 μm technology node
microcontroller and a 0.21 μm smart card integrated circuit.
We also show the ease of such technique to cover all cells of a
memory (using intrinsic features of SEM) and to automate
memory cells characterization using standard image processing
technique.
Keywords: Flash EEPROM, Reverse engineering, Scanning
Electron Microscope (SEM), Passive Voltage Contrast (PVC),
Image processing
Introduction
Embedded systems rely heavily on non-volatile memory
(ROM, EEPROM, and Flash) to store code and data. There is
a constantly growing demand for the confidentiality of the
information stored in embedded devices for Intellectual
Property (IP) protection and sensitive data such as passwords
and cryptographic keys.
Amongst non-volatile memories many investigations have
shown the weaknesses of Mask ROM (factory programmable)
against adversaries. A Mask ROM cell consists of a single
transistor and some types of Mask ROM memory can be easily
observed even under an optical microscope if the information
is encoded in the contact layer, metal layer or diffusion layer.
It was possible to read even the most secure type of Mask
ROM with an ion-implanted doping encoding under a
microscope after selective dash etching. In 1999, Kommerling
and Kuhn [1] showed how to extract ROM contents using
standard Failure Analysis techniques. Since then Mask ROMs
have not been considered to be secure unless encrypted or at
least obfuscated.
This paper focuses on Flash EEPROM and there are many
types of them. Originally EEPROM was referred to as a two-
transistor electrically re-programmable cell, while Flash was
introduced later and had a single transistor (Figures 1, 2) [2].
These days both structures are usually referred to as a Flash
memory. Each semiconductor manufacturer has many different
designs with a unique layout for Flash memory cells. But they
all have something in common – the information is stored in a
form of electric charge inside the memory transistor. The
actual number of electrons varies from 105 in old technologies
to less than 103 in modern chips. These electrons shift the
threshold voltage of the memory transistor and this is then
detected by a readout circuit. The electrons are placed into a
memory transistor by applying high voltages to the memory
transistor employing either one of two mechanisms: Fowler-
Nordheim tunneling or Channel Hot Electron (CHE) injection
(Figures 1, 2). In order to erase the cell another combination of
high voltages is applied which force the electrons to tunnel
through a very thin oxide barrier. The oxide is slowly damaged
during program-erase cycles, which result in the limited
number of programming cycles – usually between 100 and 106.
Flash EEPROM is widely used as a protection against Reverse
Engineering because conventional de-processing methods only
reveal the transistor structure and not its state. Flash EEPROM
is a memory type present in devices where security leaks
would lead to different societal and financial consequences.
The '0s' and '1s' are a matter of presence or absence of electron
charges within the floating gate. The capability to retrieve
Flash EEPROM memory contents in a practical and fast way
has never yet been published.
However, some key micro-electronics manufacturers, such as
Sharp in 2005 [3], Cypress in 2008 [4], Virage Logic in 2009
[5] and Synopsys in 2011 [6] noted the security threat relating
to the possibility of memory extraction using SEM. Plus, IBM
[7] also disclosed at CHES 2000 the following: “The electron
beam of a conventional scanning electron microscope can be
used to read, and possibly write, individual bits in an EPROM,
EEPROM, or RAM.” However, there are no publications
which substantiate this as yet. Several publications exist which
refer to Atomic Force Microscopy (AFM) techniques being
used to highlight differences between '0' and '1' in Flash
EEPROM. For instance, the use of a current applied on a
conductive tip allows seeing some interaction whenever
electron charges are present within memory cells. Following
Skorobogatov’s conclusions [8], the first investigations using
SPM-based techniques have been performed by De Nardi et
al. [9,10] and, recently, similarly performed again by different
teams Konopinski et al. [11], Hanzii et al. [12] and Dhar et al.
[13,14].
Figure 1: Structure and operation of 2T Flash EEPROM
Figure 2: Structure and operation of 1T Flash EEPROM
Due to SPM system limitations, only slow and reduced area
Flash EEPROM charge measurements are documented to date.
The main drawbacks of SPM techniques are the low scanning
speed (approximately 10 minutes per 20×20 µm image), the
small area covered (approximately 100×100 µm), the need to
replace the tip (as it becomes unusable after days of
continuous scanning) and the necessity of operator
interventions (moving to the scanning area). This results in an
impractical technique of characterizing a complete memory of
several mm2.
To satisfy the large number of transistors in integrated circuits,
recent investigations have shown the advantages of using SEM
in the security community. Courbon et al. [15] showed the
capability in practice of accessing a transistor’s active region
with the help of an easy, fast and low-cost front-side sample
preparation, based on wet etching. They use standard SEM
imagery and image processing techniques to observe and
process different shapes present in chips’ synthesized logic.
Sugawara et al. [16] prepare their sample at the contact layer
before using a SEM. They are able to distinguish the different
p/n junctions and conclude on the underlying dopant profile.
This current paper also deals with Scanning Electron
Microscopy for a different need, reverse engineering Flash
EEPROM memory contents commonly thought unreachable.
Background and proposed technique
The electrons accumulated in the floating gate are
representative of a '0' or a '1' bit value depending on the
memory manufacturer’s convention. The proposed technique
deals with accessing the floating gate transistors, probing in
situ electrons. Since decades, Voltage Contrast has been used
under SEM microscopes [18], ie for detecting shorts or open
contacts in integrated circuits [19]. In this case, the change in
contrast comes from the non-connection to the ground for a
conductor. The secondary electrons signal resulting from an
incident beam/matter interaction is dependent on several
parameters such as the primary beam features, the sample’s
atomic number, the nature of the area scanned, the doping
level. We validate that it is also possible to image local
charges trapped in an oxide using SEM in PVC mode. SEM
allows the imaging of a sample using an electron beam and
PVC imaging corresponds to the voltage contrast setup where
no external bias is applied to the sample. Secondary electrons
in-lens detectors (also known as TLD: Through-the-Lens
Detector) are particularly adapted to observe surface potential
rather than observing topography [20] due to collection
efficiency.. No work relating to the characterization of
integrated circuit embedded memory using a SEM in PVC
mode has been published to date. The goal is to be able to
characterize memory cells in a fast and efficient way. This
could have many applications in Failure and Forensic Analysis
by helping to measure the precise charge inside memory
transistors; especially in cases when the device was electrically
or physically damaged thus preventing conventional access
paths.
Table 1: Proposed technique global flow
We propose the technique outlined in Table 1, which combines
backside sample preparation, SEM acquisition and image
processing. For our dedicated application the image
acquisition step is based on three principles: having sufficient
spatial resolution to distinguish memory states, not creating a
conductive path between the control gate and the floating gate,
limiting charge-up effects inherent to the use of an electron
beam over a dielectric. Several fine-tuned parameters therefore
have to be used. Sample preparation is crucial too as all silicon
is removed down to the tunnel oxide while leaving the charge
blocking layer intact over a large area.
We acknowledge that neither the sample preparation nor the
fine-tuned SEM nor the image processing techniques are new
but their combination results in a fast and effective approach
for characterizing Flash EEPROM and its practical
implementation is about 250 times faster than AFM based
technique state of the art. Also, Scanning Electron
Microscopes are wide- spread in companies, organizations and
universities, renting one is open to everyone and costs less
than a $100 per hour.
Sample preparation
Devices Under Test
We applied our methodology on the Atmel ATmega32U4
microcontroller [21] and the Inside Secure AT90SCxx
ROM/EEPROM smart-card [22]. The microcontroller was
fabricated with a 0.35 µm CMOS process with 3 metal layers,
while the smartcard chip is 0.21 µm CMOS with 6 metal
layers. Using a universal programmer we programmed a set of
identical ATmega32U4 samples with a specific pattern to
ensure that charge differences would be noticeable no matter
what the physical layout of the memory. However, due to the
higher security of the smartcard we were unable to program
arbitrary data; still, some regions were readable, so that at least
we knew the data structure.
Accessing the area of interest
The PVC technique requires access to the region of interest,
i.e. the floating gate of the memory transistor. Two approaches
are currently documented regarding accessing floating gate
transistors (for AFM measurement techniques application):
either frontside with delayering down to the inter-poly
dielectric layer or backside down to the tunnel oxide layer.
Due to the charge nature, high energetic solutions cannot be
used (plasma etching or a high temperature approach).
Moreover, the surface roughness needs to be even over a large
surface. Thus, as in previous successful sample preparation
experiments reported in several publications, we use a
backside approach where most of the silicon substrate is
removed using mechanical polishing before a selective wet
etching is used to remove the remaining Silicon thickness,
without affecting the floating gates tunnel oxides.
Parallel lapping
The samples were prepared using a simple polishing/lapping
machine with devices mounted on a sample holding jig to
assist precise thickness control and parallel lapping surface.
The cost of this machine, shown in Table 1, is about 6000 $.
As we are using a backside approach, we first encounter and
remove a copper heatsink with the mechanical grinding tool.
Once removed, we use successively hard diamond discs to
remove silicon down to a 100 µm thickness. Then we use high
grit abrasive discs to slowly reduce the thickness down to
20±5 µm. Then, using polishing paste, we remove scratches
and obtain a mirror polish aspect with a fairly constant
roughness. The results of the different stages of the silicon
removal process are shown in Figure 3.
Figure 3: Successive silicon removal process down to:
a) Copper heatsink; b) 100µm Si; c) 20µm Si; d) polished
Wet etching
Once the 20±5 µm thickness is obtained, we use wet chemical
etching to access the floating gate transistor’s tunnel oxide.
We use the same approach as the one developed by Korchnoy
[17] and re-used in various AFM works [11]. We use Choline
Hydroxide to remove the remaining substrate without
damaging the thin tunnel oxide of 10 nm. The solution was
heated to 90ºC to increase the etching process speed while
keeping a sufficient Si/SiO2 selectivity ratio of about 5000.
The result of the selective silicon etching is presented in
Figure 4.
Figure 4: Sample after selective chemical etching
Image acquisition
Using SEM to characterize trapped charge
Parameters were chosen in accordance with PVC state-of-the-
art approaches. Once integrated circuits prepared, we used a
SEM microscope with both Field and InLens detectors
available. No success was achieved with standard secondary
electrons detectors. Therefore, we selected the InLens detector
and used a small working distance of 2 to 5 mm to maximise
secondary electrons collection. A low accelerating voltage of 1
kV to 3 kV was used, as charge-up is limited by taking an
energy close to the characterization energy of SiO2.. The
penetration depth of such a beam will not create a conductive
path between floating and control gates which lead to data
vanishing. A strong probe current degrades the signal to noise
ratio, spatial and voltage resolution. We try to use a small
diaphragm aperture to limit the probe current value. We limit
the number of incident electrons using a low magnification.
The chosen magnification (1 to 5 kX) needs to permit
sufficient pixels to characterize each memory cell though.
With regard to pixels, the chosen spatial resolution in our
experiments was 1024x768, it affects the scanning time (and
therefore the time spent on a memory point). We also limit the
number of incident electrons by using a scanning speed as fast
as tens ms per frame. At such a fast scanning speed the noise
becomes an issue, therefore, we integrated over multiple
acquisitions to achieve the final, high quality image.
Atmega32U4 content extraction
Sample preparation
Figure 5 is an optical image of the Flash EEPROM memory
array, it shows a uniform sample preparation over the full
memory array thanks to our setup.
Figure 5: Optical image of memory array in ATmega32U4
Figure 6 shows a SEM image of four Flash EEPROM memory
cells rows each containing 8 bits of information. One can
distinguish the different properties of each memory cell (2-T
design, drain contacts, tunnel oxide, word lines and a source
line in the middle of Figure 6).
Figure 6: SEM image of the memory array in ATmega32U4
Results
Depending on the capabilities of a particular SEM there are a
certain number of parameters which can be adjusted, apart
from the accelerating voltage and magnification. Aperture size,
scanning speed, dwelling time and spot size are those affecting
the PVC quality. However, we were not able to achieve a good
image quality with large apertures. Working distance was set
to 3.3 mm. When using the minimal dwelling time of 50 ns
(time on a pixel) we had to increase the probe current to
improve the signal-to-noise ratio. Although that permitted a
fair image quality, we were only able to integrate over 8
frames before the difference between cells programmed to '0'
and '1' disappeared completely. The best image contrast was
achieved at 2.5 kV with the estimated probe current of
approximately 75 pA. This resulted in a very noisy picture
presented in Figure 7.
Figure 7: Extracting memory contents at 2.5 kV with 75 pA
probe current, images integrated over 8 frames
We continued working on improving the image quality and
found that at lower probe currents the charge was staying
longer thus permitting larger number of frames to be scanned.
As a result we were able to integrate over tens of frames, thus
significantly reducing the noise. Figure 8 shows the result of
such an acquisition at the highest scanning speed at 2 kV with
15 pA probe current at a larger working distance of 5.3 mm.
Figure 8: Extracting memory contents at 2kV with 15pA probe
current, images integrated over 50 frames
The best image quality and contrast was achieved for the same
working distance of 5.3 mm at 2.5 kV – a compromise
between the best contrast and a reasonable number of frames
we can acquire before the charge disappears from the floating
gate of the memory transistors. The probe current was about
20 pA with these settings. All those parameters allowed us to
obtain clear differences between '0' and '1' states as seen in
Figure 9. It has to be noted that all images were obtained
without additional image processing to highlight differences
between '0' and '1' states. From the programmed test data we
worked out that '0' state of a programmed cell corresponds to
the darker memory cell, while '1' state of an erased cell
corresponds to the brighter cell. After several acquisitions with
such parameters, all cells become dark. It is possible to control
the process of “injecting and removing charge” by adjusting
the accelerating voltage and probe current. Also, one can
notice a bright surface if a high density electron beam interacts
with the sample.
Figure 9: Extracting memory contents at 2.5kV with 20pA
probe current, images integrated over 50 frames
Over Figure 9, we note 40 lines of information each containing
16 bytes (128 bits). It results in 640 bytes per acquisition. In
terms of time, we require approximately 9.5 seconds to
achieve this image (factor of scanning speed, and noise
reduction setup). Thus, the final acquisition throughput is
approximately 67 bytes per second, or approximately 4
kilobytes per minute.
Figure 10 outlines the characterization information that can be
extracted. Some memory cells look brighter than the others.
This is likely to be caused by the difference in the trapped
charge on the floating gates of the memory cells. For chip
manufacturers this could present a valuable tool to map the
actual charge trapped inside each memory transistor for
Failure Analysis purposes.
Figure 10: Zoom into SEM image for characterization
Blocked or passing transistors states (convention '0' and '1' for
this ATMEL sample) can be clearly distinguished as the dark
(holes, positive charge) and the bright (electrons, negative
charge) areas respectively. The intermediary contrast seen at
the word line is confirmed by the theory. Indeed, unlike 1T
cell, the theoretical 2T cell contrast difference between
programmed and erased are equal to twice the charge (as a 1T
depleted cell has a null charge).
From the test pattern that was programmed into samples we
also figured out the physical layout of the memory. The array
was split into 16 blocks each representing one bit of data from
the bit0 being the most right one to the bit15 located on the
left. The addresses were going sequentially from right to left
and each upper line had its corresponding address 128 bytes
higher. Taking the example of the device under test, the
complete memory content extraction (32 kbytes) would take
approximately 8 minutes of SEM acquisitions (less than 10
minutes including a 10 per cent image overlap).
AT90SCxx content extraction
We then validate the PVC reading technique over a second
sample, which uses a more recent technology node (0.21 µm
vs 0.35 µm). The idea is to see how far the technique could
work, despite the smaller number of electrons to be probed.
Figure 11: Optical image of memory array in AT90SCxx
Sample preparation
Figure 11 is an optical image of the AT90SCxx Flash
EEPROM memory array. The sample preparation step remains
identical as we use a backside sample preparation and
therefore we are independent of the number of metal layers.
Figure 12 shows a SEM image of three Flash EEPROM
memory cells columns each containing 2 times of 8 bits of
information.
Figure 12: SEM image of the memory array in AT90SCxx
SEM imaging with PVC
The same imaging setting as we used for the microcontroller
were initially applied. However, as technology nodes decrease,
we had to increase the magnification to have sufficient pixels
for characterizing each memory cell. We also decreased the
working distance to maximize the number of secondary
electrons detected.
Results
Figure 13 is a SEM acquisition showing the differences
between '0s' and '1s'. Some contrast enhancement has been
performed after acquisition to improve the visibility of the
difference between programmed and erased memory cells.
Also, due to the higher magnification and smaller cell size it
was only possible to integrate over maximum of 40 frames at
2.5 kV accelerating voltage and 20 pA probe current, even at a
shorter working distance of 3.0 mm. Beyond that point all
memory cells look alike. One of the reasons for that is because
incident electron beam density is important.
Figure 13: Extracting memory contents at 2.5kV with 20pA
probe current, images integrated over 40 frames
On the zoom presented in Figure 14, '0' and '1' states can be
distinguished as the bright and the dark areas respectively.
Each column represents 8 bit of information from bit7 at the
top to bit0 at the bottom. The addresses were going
sequentially from left to right and each lower line had its
corresponding address 128 bytes higher. The PVC mode in
SEM is thus also implemented with success over this 0.21 µm
technology node integrated circuit.
Figure 14: Zoom into SEM image for characterization
Complete memory application
The methodology being validated over both previous samples,
we then demonstrate the capability to make operator free large
scans using intrinsic properties of Scanning Electron
Microscopy. The area to characterize, ie the full memory, is
set as region of interest thanks to a graphical user interface.
We keep the previous set of SEM parameters. Depending on
the defined magnification and the size of the memory, a certain
amount of images to acquire are indicated. The user can also
define an overlap permitting to ease the alignment of
individual images covering the entire memory, Figure 15.
Figure 15: Left: defining area, right: editing macro
Images are thus all saved and the use of SEM is over. Offline,
a multiple image alignment can be performed using open
source software or standard matlab commands based on phase
transform algorithm. In Figure 16, we give such example over
two successive acquisitions. No artefacts are obtained, and the
image alignment process only requires less than a minute for a
complete memory.
Figure 16: Left: First and second acquisition, right: final 1st
and 2nd acquisition alignment
Trapped charge characterization
We have demonstrated how to distinguish intensities variations
and to do so over a large area. The next step is to automate the
processing of such information. A Failure Analysis engineer
can observe multiple information and multiple paths can be
taken to outline it. We detail here how such technique could be
applied to detect a non-functional memory cell or a memory
cell lacking electrons (reducing its lifetime). It could be
expressed by a grayscale intensity value much smaller than the
intensity values of functional cells. In Figure 17, we extract a
64 bits profile line from the acquisition already seen in Figure
10.
Figure 17: Top: subpart of Figure 10 raw SEM image,
bottom: line profile of 64 bits of information
Using grayscale intensities only, Figure 17 does not permit to
segment cells. We then go through successive basic image
processing steps. Figure 18 shows the same memory location
after the use of multiple basic image processing techniques
such as histogram equalization and image filtering. Over this
figure one can begin to observe a profile line giving more
differences between ‘0s’ and ‘1s’.
Figure 18: Top: subpart of Figure 10 SEM image after
processing, bottom: line profile
We then select an intensity threshold value to characterize
memory cells to say if they are uncharged or not. If cells
appear black under the microscope and should be at ‘1’ in this
memory then those cells present a failure. Figure 19 directly
gives the binary pattern: ‘01010011000011110000000111111-
1100000000000000001111111111111111’ and working this
way allows a direct correlation with the input data file.
Figure 19: Top: subpart of Figure 10 SEM image after
processing and thresholding, bottom: line profile
One can also imagine applying this technique after a certain
number of write operations. If some cells do not appear bright,
then those can be considered as cells with data retention
problem. It can be an input for the failure analysis operator
before applying a corrective action to the problem. One can
also think about processing points that are along the memory
grids made of repetitive rows and columns. The overall
success of the methodology is matter of the sample preparation
but also of the capability to do not have SEM acquisitions
artefacts (such as in Figure 13). Applying image processing
could then be possible and of interest in order to quantify the
charge level (and indirectly the number of electrons stored).
Further work
It would be interesting to challenge the technique where fewer
electrons are stored in Flash EEPROM floating-gate
transistors. The applicability of the technique for smaller
technology nodes is seen as possible given that improvements
and optimizations ways are multiple. They could involve, for
example, improving the SEM contrast by adding coatings,
improve the data acquisition by having different parameters
such as the sample orientation or also process images after
acquisition. We will also try to extract the whole memory
contents to estimate the error rate and practicality of this
technique. Despite an already low magnification chosen in our
investigations, Figure 20 shows that it is even possible to get
information at a 218 times magnification. It definitely
highlights that this dedicated application is open to several
improvements.
Figure 20: A lot of parameters to optimize, here we can
differentiate 0s and 1s despite a large field of view
Conclusions
We introduce the first publication detailing Flash EEPROM
direct charge measurements using a Scanning Electron
Microscope. Using backside sample preparation and Passive
Voltage Contrast techniques we successfully extracted memory
contents at an imaging throughput of 4 kbytes per minute. It
beats current state of the art memory content extraction by a
factor of approximately 250. The technique requires a
polishing tool, wet etching acid and few hours Scanning
Electron Microscope renting. To conclude, the proposed
methodology represents an optimization of Failure Analysis
techniques but also a threat for security related concerns.
We were not only able to distinguish between memory cells
programmed with a '0' and '1' state, but were also able to see
the difference in the trapped charge on the Floating Gates of
memory cells. For chip manufacturers this could present a
valuable tool to map the actual charge trapped inside each
memory transistor for Failure Analysis purposes. This could
help in addressing the issues with data retention time, radiation
hardness testing and data remanence effects in Flash EEPROM
memory devices. It could also be useful for Forensic Analysis
applications when the contents of the embedded memory needs
to be extracted from devices which were electrically or
physically damaged as a result of an accident or a deliberate
attempt to remove data.
References
[1] O. Kommerling and M. Kuhn: Design principles for
tamper-resistant smartcard processors, 1st worskop on
Smartcard Technologies, 1999
[2] W. Brown, J. Brewer, Nonvolatile Semiconductor
Memory Technology: A Comprehensive Guide to
Understanding and Using NVSM Devices, IEEE Press,
1997.
[3] G. Smith: Addressing Security Concerns of Flash
Memory in Smart Cards. Application Note, Sharp, 2005
http://www.sharpsma.com/download/Security-Concerns-
Flash-Anpdf
[4] K. Ramkumar: Cypress SONOS Technology. White
Paper, Cypress Semiconductor, 2008
http://www.element14.com/community/servlet/JiveServl
et/previewBody/28069-102-1-
77264/cypress_sonos_technology_11.pdf
[5] T. Humes: Ensuring data security in logic non-volatile
memory applications: Floating-gate versus oxide
rupture. Virage Logic, 2009 http://mil-
embedded.com/articles/ensuring-versus-oxide-rupture/
[6] C. Zajac: Protect Your Electronic Wallet Against
Hackers. White Paper, Synopsys, 2011
https://www.trust-
hub.org/resources/350/download/synopsys_wallet.pdf
[7] S. Weingart: Physical Security Devices for Computer
Subsystems: A survey of Attacks and Defences, CHES
2000
[8] S. Skorobogatov: Semi-invasive attacks - A new
approach to hardware security analysis. University of
Cambridge Technical Report, 2005
[9] C. De Nardi, R. Desplats, P. Perdu, F. Beaudouin and J.-
L. Gauffier, Oxide charge measurements in EEPROM
devices, Microelectronics Reliability, Vol.45, 2005, pp
1514-1519
[10] C. De Nardi, R. Desplats, P. Perdu, C. Guérin, J.L.
Gauffier, T.B. Amundsen: Direct Measurements of
Charge in Floating Gate Transistor Channels of Flash
Memories Using Scanning Capacitance Microscopy.
ISTFA, 2006
[11] D. Konopinski, Forensic applications of atomic force
microscopy, 2013
[12] D. Hanzii, E. Kelm, N. Luapunov, R. Milovanov, G.
Molodcova, M. Yanul, D. Zubov: Determining the state
of non-volatile memory cells with floating-gate using
scanning probe microscopy. International Conference
Micro- and Nano-Electronics, 2012
[13] R. Dhar, S. Dixon-Warren, J. Campbell, M. Green, D.
Ban et al: Direct charge measurements to read back
stored data in nonvolatile memory devices using
scanning capacitance microscopy. 2013
[14] R. Dhar, S. Dixon-Warren, M. Kawaliye, J. Campbell,
M. Green, D. Ban: Read Back of Stored Data in Non
Volatile Memory Devices by Scanning Capacitance
Microscopy. Materials Res. Soc. Symposium, 2013
[15] F. Courbon, P. Loubet-Moundi, J.A. Fournier, A. Tria:
Increasing the efficiency of laser fault injections using
fast gate level reverse engineering. HOST Symposium,
2014
[16] T. Sugawara, D. Suzuki, R. Fujii, S. Tawa, R. Hori, M.
Shiozaki, T. Fujino: Reversing stealthy dopant-level
circuits. CHES Workshop, 2015
[17] V. Korchnoy: Investigation of Choline Hydroxide for
selective Silicon etch from a gate oxide failure analysis
standpoint. 2002
[18] J. Colvin: A new technique to rapidly identify low level
gate oxide leakage in field effect semiconductors using a
scanning electron microscope, EOS/ESD Symp., 1990
[19] M. Jenkins, P. Tangyunyong, E. Cole Jr., J. Soden, J.
Walraven, A. Pimentel: Floating substrate passive
voltage contrast (FSPVC). ISTFA, 2006
[20] E. Cole Jr.: Beam-based localization techniques for IC
failure analysis. Microelectronic failure analysis desk
reference, 1999
[21] Atmel Atmega32U4 AVR Microcontroller.
http://www.atmel.com/devices/ATMEGA32U4.aspx
[22] Inside Secure AT90SC Secure Microcontroller
Summary. http://www.insidesecure.com/Products-
Technologies