Digital Panoramic X-ray System
Transcript of Digital Panoramic X-ray System
![Page 1: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/1.jpg)
PaX-P&P
Digital Panoramic X-ray System
User Manual
![Page 2: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/2.jpg)
PaX-P&P User Manual
Specifications
1. Product Digital X-ray Imaging System
2. Model Name Pax-P&P
3. Manufacturer & Address
Vatech Co., Ltd
75-11, Seogu-ri, Dongtan-myeon,Hwaseong-si,
Gyeonggi-do, 445-811, Korea
4. Date of Production
Weight & Unit Labeled on This Product
5. Performance & Usage See User Manual and/or Catalog
6. Cautions See User Manual
7. Power Source 110V/220V, 50Hz/60Hz
8.Power Consumption 1.3 Kw (MAX)
Vatech Co., Ltd 1
![Page 3: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/3.jpg)
PaX-P&P User Manual
General Safety Summary
To avoid potential hazards, please use this product only as indicated below.
1. For the safety of user and patient, please read this User Manual thoroughly before
using this product.
2. Comply with safety terms and process of use in this User Manual.
3. If you suspect there is damage to this product, please have it inspected by qualified
service personnel of your agent.
4. Fire or electrical accidents could be caused by exposing to liquid and pressure.
5. PaX-P&P should be operated within recommended voltage. In case of changing
voltage, contact your agent.
Vatech Co., Ltd 2
![Page 4: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/4.jpg)
PaX-P&P User Manual
Notice
The information contained in this manual is subject to change without any notice to improve
performance.
Vatech is not responsible for the damage or the accident caused by computer trouble, wrong
installation, improper maintenance and wrong operation.
The information in this manual may be different according to specifications of product.
In this manual, you can find 3 symbols for proper usage as below:
Indicates useful information for operating the product.
Indicates important instructions for operating the product. If you don’t follow, it may cause a malfunction. Indicates safe instructions for operating the product. If you don’t follow, it may cause extreme dangers to the patient.
Vatech Co., Ltd 3
![Page 5: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/5.jpg)
PaX-P&P User Manual
Contents Chapter 1 Introduction ................................................................... 5
1. Features............................................................................................................... 6
2. Package............................................................................................................... 7
3. Precautions.......................................................................................................... 8
Chapter 2 Structure ...................................................................... 11
1. The Structure of hardware ................................................................................. 12
2. The Composition of software............................................................................. 13
Chapter 3 Operation ..................................................................... 15
1. Preparations ...................................................................................................... 16
2. Positioning patient ............................................................................................. 17
3. Capturing Image ................................................................................................ 21
Chapter 4 Troubleshooting .......................................................... 29
1. Troubleshooting ................................................................................................. 30
Vatech Co., Ltd 4
![Page 6: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/6.jpg)
PaX-P&P User Manual
1 Chapter 1 Introduction
This chapter describes general features, structure of product and precautions in detail
Vatech Co., Ltd 5
![Page 7: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/7.jpg)
PaX-P&P User Manual
1. Features
● Less X-Ray dose for patient safety.
● Easy to control with PC
● Embedded Voice Guidance and LCD screen for a comprehensive direction to patient
at any stage.
● Easy to solve any problems.
● Easy to upgrade with C.A.N communication.
What is C.A.N Communication?
1. Abbreviation
● Controller Area Network
2. Purpose
● Use a memory of the MCU (Main Controller Unit) of each part to distribute the
loads of main control system.
● Reduce the loads of MCU with Distributed Processing System.
● Improve the communication of each MCU and stability of device.
Vatech Co., Ltd 6
![Page 8: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/8.jpg)
PaX-P&P User Manual
2. Package
Hardware
● PaX-P&P (including cables)
● Installation CD
● User Manual
● Accessories
The specifications of the hardware are subject to change for upgrading equipment without a prior notice.
Software
● EasyDent V4 program: Image viewer and Capture program
The specifications of the software are subject to change for upgrading equipment without a prior notice.
Vatech Co., Ltd 7
![Page 9: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/9.jpg)
PaX-P&P User Manual
3. Precautions
Please follow the instructions as below.
● For safety reasons, operate the product according to this User Manual.
● Check the conditions of the product (power, Cables) and PC before operating.
● Every operation of the product should be done step by step after the each
previous step is finished. Otherwise, it could cause malfunction.
● Go to next capture stage after finishing cooling time to prevent tube from being
overheated as per voice guidance or message on screen.
● Keep away from water, moisture, corrosive materials, and chemical materials.
● If there is an abnormal movement, turn off the system and then contact your
agent.
Vatech Co., Ltd 8
![Page 10: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/10.jpg)
PaX-P&P User Manual
Safe Regulation for Radiation Protection
As radiation safety and protection requirements vary from country to country and state to state, it is the responsibility of the operator to ensure that all local and national radiation safety and protection requirements are met.
● When X-ray is exposed, operators must protect themselves from radiation
by using a lead apron or by standing behind a suitable radiation shield.
● When X-ray is exposed, operators must provide the precaution to protect from
radiation by using a lead apron.
● In case of children or pregnant women, consult a doctor before X-ray exposures.
● When X-ray is exposed, operators must stand at least two meters (6feet) from X-
ray source.
● Operators must observe the patient during the exposure time in case of
emergency situation.
● When X-ray is exposed, operators must stop the system in case of any abnormal
movement.
This product could be exploded under the circumstances of being explosive material or liquid.
Vatech Co., Ltd 9
![Page 11: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/11.jpg)
PaX-P&P User Manual
The responsibility of manufacturer
The manufacturer and/or agent have the responsibility for the conditions as
below.
● PaX-P&P is installed by people who are qualified and trained by agent.
● PaX-P&P is installed as manual indicated.
● Use parts that are approved by VATECH
● Maintenance and repair services are made by people who are qualified
and trained by VATECH and/or its agent.
● PaX-P&P is operated as manual indicated.
● User doesn’t make breakage or accident.
Vatech Co., Ltd 10
![Page 12: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/12.jpg)
PaX-P&P User Manual
2 Chapter 2 Structure
This chapter describes structure, functions and software in detail so that end-user can make full use of P&P.
Vatech Co., Ltd 11
![Page 13: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/13.jpg)
PaX-P&P User Manual
1. The Structure of hardware `
Tube area
LCD Screen
Sensor area
Lamp button
Emergency Switch
Handle frame
LED Lamp
● LCD Screen : Show guide messages at each step for proper patient position.
● Sensor area : There is a X-ray image Sensor module.
● Tube area : There is a Tube generating X-ray beam.
● LED Lamp : Changed from blue to orange when X-ray is generated.
● Handle frame : Patient can grip for proper position.
● Emergency switch : Press this button in emergency situation.
● Lamp button : Press this button to turn on Laser beam
(The Laser beam will be turned off after 3 minutes)
Vatech Co., Ltd 12
![Page 14: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/14.jpg)
PaX-P&P User Manual
2. The Composition of software The followings are a brief explanation about the composition of capturing program.
⑫
⑪
⑩ ⑨
⑧
⑦
① ②
③
④ ⑤
⑥
① Display of capturing status and image
● Display the progress of capturing stage.
② Patient information.
● Show chart No, Name, and Age of patient.
③ Message instruction.
● Shows Instruction in accordance with capturing process.
④ Selecting the gender
● Select Man, Woman or Child
⑤ Selecting the build
● Select Fat, Normal or Slim
Vatech Co., Ltd 13
![Page 15: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/15.jpg)
PaX-P&P User Manual
You can not choice patient type on child mode.
⑥ Select capture mode
● Select capture mode among the Normal, Tmj Open, Tmj Close, Sinus, Right, Front, Left.
⑦ Mode Confirm
● Click after choosing capture mode and patient type.
⑧ Open, Save, Exit
● Open image file, Save image file, Close capture program.
⑨ Kvp and mA
● Be able to adjust Kvp value manually (40Kvp~90Kvp)
● Be able to adjust mA value manually (2mA~10mA)
⑩ Lamp
● Turn On / Off lamp for positioning patient.
⑪ Return
● Cancel the present setting.
⑫ Ready
● Click “Ready” after positioning patient.
⑬ Progress bar
● Indicates the progress of capturing image and processing.
The composition could be varied and changed without notice for developing or upgrading capturing program.
Vatech Co., Ltd 14
![Page 16: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/16.jpg)
PaX-P&P User Manual
3 Chapter 3 Operation
This chapter describes how to operate PaX-P&P for proper usage.
Vatech Co., Ltd 15
![Page 17: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/17.jpg)
PaX-P&P User Manual
1. Preparations
Check followings before capturing image.
● Turn on the product first and then turn on PC.
● Check whether the product is turned on or not.
● Do not operate the product while the previous step or movement is not
Finished.
● Check whether PC operation is normal or not.
Follow the instruction message on the screen.
Vatech Co., Ltd 16
![Page 18: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/18.jpg)
PaX-P&P User Manual
2. Positioning patient
To acquire the best image, please comply with followings.
① Ask patient to take off any materials such as glasses, earrings,
necklaces or any accessories.
② Patients should wear lead apron to protect from radiation.
③ Adjust the height of the Chinrest to patient.
④ Position patient on the middle of product.
⑤ While the patient is holding the handles, ask to step
forward so that the patient inclines to the back side.
Vatech Co., Ltd 17
![Page 19: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/19.jpg)
PaX-P&P User Manual
⑥ Ask patient to bite the bite block after covering with a hygienic bag provided.
⑦ Adjust the Frankfurt beam to patient.
⑧ Adjust the Middle beam to patient.
Vatech Co., Ltd 18
![Page 20: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/20.jpg)
PaX-P&P User Manual
⑨ Adjust the Canine beam to patient as the picture below
⑩ Sinus Mode.
Adjust the Canine beam as the picture above.
10~15°
Vatech Co., Ltd 19
![Page 21: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/21.jpg)
PaX-P&P User Manual
⑪ Toothless Patient
Adjust the Canine beam as the picture above.
Vatech Co., Ltd 20
![Page 22: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/22.jpg)
PaX-P&P User Manual
3. Capturing Image
Registering a New Patient Please do following instructions to register a new patient.
① Turn on the product and PC.
② Run EasyDent V4program and then, Click “Patient” ( ) icon to register a new
patient.
③ Input the information of the patient on the register window as below.
④ Click “Add” to complete the registration of the new patient information.
When capturing a registered patient, do not need to register again.
Vatech Co., Ltd 21
![Page 23: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/23.jpg)
PaX-P&P User Manual
The procedure of capturing image
Please follow the instructions below for capturing image.
In case of capturing TMJ modes, TMJ close mode will be ready automatically after capturing TMJ Open.
① Turn on PaX-P&P and PC.
② Run EasyDent V4 program and then select patient.
Clic③ k “Panorama” icon to run capturing program.
Vatech Co., Ltd 22
![Page 24: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/24.jpg)
PaX-P&P User Manual
Operating the system during communication with sensor may cause wrong movement or malfunction.
④ Capturing screen will be displayed after initializing.
⑤ Set the condition of capturing image modes.
-Patient, Patient type, Kvp, mA, Capture mode.
⑥ After setting, click ( ) “Mode Confirm”.
Each mode and condition has the default value of Kvp and mA. If needed, you can change the value of Kvp and mA.
Vatech Co., Ltd 23
![Page 25: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/25.jpg)
PaX-P&P User Manual
⑦ Position patient (Refer to page 17~20)
Use “Lamp”( ) button to position a patient to the right position. The Lamp will be turned off after 3 minutes automatically.
Please wait until the progress bar is finished.
Vatech Co., Ltd 24
![Page 26: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/26.jpg)
PaX-P&P User Manual
⑧ Keep pressing Exposure switch.
Please keep pressing Exposure switch until the Progress bar is comple ted. Otherwise, the image capture will be canceled.
Vatech Co., Ltd 25
![Page 27: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/27.jpg)
PaX-P&P User Manual
⑨ Keep pressing Exposure switch button until the progress bar is finished.
and then, the captured image will be optimized on the screen.
During capturing, there will be “Capture Image Preview” to see the progress of capturing image.
After finishing image capture, there will be the image just captured.
Vatech Co., Ltd 26
![Page 28: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/28.jpg)
PaX-P&P User Manual
⑩ Click “OK” to save the image after capturing.
Or click “Cancel” to capture again
⑪ Click “OK” to capture same patient again.
Or click “Cancel”.
Vatech Co., Ltd 27
![Page 29: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/29.jpg)
PaX-P&P User Manual
⑫ Double click the latest thumbnail image to see the image just captured.
⑬ This is Normal Panorama image captured by PaX-P&P.
For more detail information, refer to the User manual of EasyDent V4.
Vatech Co., Ltd 28
![Page 30: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/30.jpg)
PaX-P&P User Manual
4 Chapter 4 Troubleshooting
This chapter describes how to solve any problems that you may meet during operation.
Vatech Co., Ltd 29
![Page 31: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/31.jpg)
PaX-P&P User Manual
1. Troubleshooting
In case you meet any troubles during operating, follow instructions below to check and
fix the trouble and/or contact your agency.
.
● No movement of the product
Factors Solutions
Power Check the power of the product
Initializing Turn off and turn on again
Connection with PC Check the connection of RS232 cable with PC
Up / Down Check emergency button
Check Up / Down switch
● No movement of Exposure switch
Factor Solution
Ready to capture Check whether the system is ready to capture or not
● Malfunction of laser beam
Factor Solution
Overtime Click Lamp button on capturing screen.
Vatech Co., Ltd 30
![Page 32: Digital Panoramic X-ray System](https://reader034.fdocuments.net/reader034/viewer/2022050705/55203f914a79597d718b4681/html5/thumbnails/32.jpg)
PaX-P&P User Manual
Vatech Company Limited
75-11 Seogu-ri, Dongtan-myen,
Hwaseong-si, Gyeonggi-do, 445-811, Korea
Tell: 031) 377-9554
Fax: 031) 377-1882
Homepage: www.vatech.co.kr
Vatech Co., Ltd 31