digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017...

12
digital audio modular processing system C8000 Dolby ® D/D + encoder C8612 phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com 1/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY features • Fully compliant Dolby ® Digital (AC3) or Dolby ® Digital+ Encoder • 5.1 and independent 2.0 Encoders • 5.1 transcoder from Dolby ® Digital (AC3) to Dolby ® Digital+ • 16 / 20 / 24 Bit Audio input data format • RS485 Metadata input • Metadata selectable from audio input, external or presets • Unique Metadata extractor to gather up Metadata from C8000 bus • Eight Metadata presets • Dolby ® Metadata display and editing • Coded output stream available on internal bus as well as on BNC • Unbalanced, AES output for Dolby ® encoded signals • Remote control (web interface) via C8702 frame controller block diagram

Transcript of digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017...

Page 1: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

1/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

features

• Fully compliant Dolby® Digital (AC3) or Dolby® Digital+ Encoder • 5.1 and independent 2.0 Encoders • 5.1 transcoder from Dolby® Digital (AC3) to Dolby® Digital+ • 16 / 20 / 24 Bit Audio input data format • RS485 Metadata input • Metadata selectable from audio input, external or presets • Unique Metadata extractor to gather up Metadata from C8000 bus • Eight Metadata presets • Dolby® Metadata display and editing • Coded output stream available on internal bus as well as on BNC • Unbalanced, AES output for Dolby® encoded signals • Remote control (web interface) via C8702 frame controller

block diagram

Page 2: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

2/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

technical specifications

External output: connector BNC impedance 75Ω signal level 1Vp-p standard AES 3, SMPTE 276M unbalanced data format 16, 20, 24bit sample rate 48kHz

Input audio formats 16, 20, 24bit Output audio formats:

Dolby® D (AC3) 16bit streams 48kHz Dolby® D+ (E-AC3) 16 or 32bit streams 48kHz

Latency:

Dolby® D 91ms Dolby® D+ 112ms

Metadata input:

format Standard Dolby® Metadata stream (RS485) baud rate 115,2kbps connector Sub-D, 9-pin, female

Backplane connector: ref. to DIN 41612, 64pin, a+b, male Power supply: +5V DC Consumption: approx. 600mA Dimensions: 3RU, 4HP, 160mmd deep (Euro Format) Ambient: 10ºC to 40ºC Humidity: 90%, non condensing

Dolby® Metadata The Dolby® Laboratories, Inc. have introduced the “data about the audio data“, the Dolby® Metadata which travel along with the multi channel bit stream from acquisition (point of audio recording) to delivery (Dolby Digital decoder at home (either part of the TV Set Top Box or the home theater system). Beside some technical issues, like the configuration of audio channels, those Metadata may control the home equipment in a way that the sound impression is as close as possible to what the producers intention was when mixing a movie sound track. There is not enough room for explanation of the Dolby Metadata system in a product manual like this. We recommend to those who are not familiar with this quite complex matter, to study the many publications from Dolby Inc. probably found here:

http://www.dolby.com/technicallibrary.aspx?id=306&taxid=166 You can browse the Technical Library and <Search> for “Dolby E”. Here you will find the “Dolby® Metadata Guide”.

Page 3: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

3/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

installation

INIT

BUS-EN ON

DIP

SW-1BSW-1CSW-1D

BOOTCANADDR

Set the CAN ADDR rotary encoder to an address, which is not in use by an other module of a C8000 frame (for details regarding CAN addressing, see C8000 system manual).

BUS-EN = OFF will disable the bus driver circuits on power up SW-1B = ON enables the CAN “+16” address schema to handle up to 32 modules SW-1C = not used SW-1D = not used

Important Note! If the module has an unknown bus configuration, you must set BUS-EN=OFF, before inserting the module into a C8000 frame. Otherwise you are in risk to disturb other channels of the frame. Pressing the INIT button during power up, will initialize the module parameters to factory default values.

status LEDs

STATUS green = OK red = bad flashing

green = under GUI control

DOLBY D green = Off =

DOLBY D+ blue = Off =

Page 4: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

4/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

web browser based configuration

Se tup of all configurations, parameters and functions via a web browser. See also C8702 Frame Controller.

OVERVIEW

The above example shows a C8612 (Name: “AC3 Encoder”) in a typically processing chain. Clicking on the spanner tool within the module graphics of the C8612 will open the pages of that module. If you click on the switch tool you will get the page for changing Presets only.

Page 5: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

5/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

PRESETS

Because this device has two independent encoders, it offers two independent sets of Presets. But in case of Dolby D to D+ transcoding, there is no user intervention possible, i.e. Preset operation and Metadata setup are not possible in this case.

Load Preset will load one of the 8 available Presets (1-8 for Encoder 1 and 9 to 16 for

Encoder 2) from the modules NV memory

Save as Preset here you can select a Preset Number (memory location) and assign that preset a 4 character name

Preset Clipboard you can copy the data of the active parameters of the two sets of Presets to a clip board and paste such data into the Preset memory of another module within one frame

Backup Presets store all presets of one C8612 into a file

Restore Presets restore all presets of a C8612 from a file

Page 6: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

6/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

DEVICE

Device Name You can assign a 16 digit name to the module.

Restart Module Pressing <RESTART> will warm start the module.

Initialize Pressing <INITIALIZE> will initialize the module to factory default.

Controller Version Display of the firmware version of the module controller.

Dolby Firmware Version Version of the Dolby piggyback module.

BACKUP Pressing <BACKUP> will move all settings including the Presets to the PC, so you can store the backup data to a file.

RESTORE Pressing <RESTORE> after loading a backup file will move all settings including the Presets back to the module.

Page 7: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

7/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

SETUP / ROUTING : Setup of the module and the Bus routing

From C8000 System Bus The audio busses from the C8k frame may be assigned to the encoder

channels for the respective signals. An AC3 signal may be provided for D >> D+ transcoding

To C8000 System Bus The encoder outputs may be assigned to C8k busses as well as to the external BNC output

Enable Bus Driver You may turn off (tri state mode) all bus drivers for installation to prevent conflicts with modules already in service.

Page 8: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

8/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

Error Detection The serial audio data from the frame bus can be monitored for proper

positioning of an Error-Flag. A bad Error-Flag is an indication that there is disturbance upstream (input signal, input module, DSP module). The Error Detection can be turned Off and On for each input from the bus. You will see the status on the left hand side: “Embedder (Bus Status)”. A grey “LED” shows that the detection is disabled. While green is OK, red indicates an error condition.

The bus status as well as the SDI input status may be presented to external monitoring systems via SNMP. The frame controller summarizes such status information and generates SNMP traps for the frame as an entity or may activate GPOs (if GPI/O module(s) are installed). The SNMP manager may afterwards poll the “modulesStatus” for more detailed status information per input (see SNMP documentation for details).

Mode The Dolby® module offers different operating modes (e.g. PCM encoding to Dolby D or Dolby D+ or Dolby® D to D+ transcoding) for both encoders.

Metadata Source For both encoders, the source of the Metadata can be selected independently either from the C8k bus, from a Preset or via external (RS485) connector.

Channel Status Bits For both bus outputs OUT1 and OUT 2 as well as for the BNC output you can decide between indication of Professional or Consumer format.

Page 9: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

9/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

METADATA ENC 1 : Shows the set of Metadata which are relevant for the first encoder.

If the Metadata Source is set to Preset you may change these values. In Preset mode the Extended Bitstream Information are enabled. In this case the Nominal Center and Surround Mix Level are mapped from the Lo/Ro parameters. If the Metadata Source is set to Bus it is possible to overwrite the Data Rate value manually.

There is not enough room for explanation of the Dolby® Metadata system in a product manual like this. We recommend to those who are not familiar with this quite complex matter, to study the many publications from Dolby Inc. you will probably find here:

http://www.dolby.com/technicallibrary.aspx?id=306

You can browse the Technical Library and <Search> for “Dolby E”. Beside many other documents you will find “A Guide to Dolby Metadata”.

On page 11/12 you will find a table of the Metadata and their respective values for both encoders.

Page 10: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

10/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

METADATA ENC 2 : Shows the set of Metadata which are relevant for the second encoder.

If the Metadata Source is internal (Preset) you may change these values. For details on the meaning of such Metadata, see the relevant Dolby® papers (see above). On page 11/12 you will find a table of the Metadata and their respective values for both encoders.

Page 11: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

11/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

Dolby Digital Metadata for C8612 encoders :

Parameter

Range Encoder 1 Range Encoder 2

General

Channel Mode 1+1, 1/0, 2/0, 3/0, 2/1, 3/1, 2/2, 3/2

1+1, 1/0, 2/0

LFE On, Off N.A. Bit Stream Mode

C. Main, Mus Eff Vis. Imp, H. Imp Dialogue, Comment Emerg., Karaoke

C. Main, Mus Eff Vis. Imp, H. Imp Dialogue, Comment Emerg., Karaoke

Original Bit Stream

On, Off On, Off

Copyright

On, Off

On, Off

Dynamic Range Control Dialog Normalization -1dBFS ... -31dBFS -1dBFS ... -31dBFS Profile Line Mode

None, Film St Film Lt, Mus St Mus Lt, Speech

None, Film St Film Lt, Mus St Mus Lt, Speech

Profile RF Mode None, Film St Film Lt, Mus St Mus Lt, Speech

None, Film St Film Lt, Mus St Mus Lt, Speech

Filter DC-Highpass On, Off On, Off Low Pass On, Off On, Off LFE Low Pass On, Off N.A. RF Overmod. Protection On, Off On, Off Surround 3dB Attenuation On, Off N.A. Surround Phase Shift On, Off N.A

Downmix Nominal Center Mix Level -3dB, -4,5dB, -6dB N.A Nominal Surround Mix Level

-3dB, -6dB, off N.A

Preferred Downmix Mode Not indicated Lt/Rt, Lo/Ro

N.A

Lo/Ro Center Mix Level OFF, -6dB, -4,5dB -3dB, -1,5dB, 0dB 1,5dB, 3dB

N.A

Lo/Ro Surround Mix Level OFF, -6dB, -4,5dB -3dB, -1,5dB

N.A

Lt/Rt Center Mix Level OFF, -6dB, -4,5dB -3dB, -1,5dB, 0dB 1,5dB, 3dB

N.A

Lt/Rt Surround Mix Level OFF, -6dB, -4,5dB -3dB, -1,5dB, 0dB 1,5dB, 3dB

N.A

Page 12: digital audio modular processing system Dolby D/D encoder ... › wp-content › uploads › 2017 › 02 › C... · digital audio modular processing system C8000 ... • 5.1 and

digital audio modular processing system

C8000

Dolby® D/D+ encoder C8612

phone : +49-30-677721-0 fax : +49-30-677721-46 [email protected] www.junger-audio.com

12/12 Jünger Audio-Studiotechnik GmbH Justus-von-Liebig-Straße 7 D – 12489 Berlin GERMANY

GPI/O

On the GPI/O page you can assign GPI numbers to activate one of the Presets for Encoder 1 and 2 If a GPI is detected by a GPI/O module C8817 it will put an associated number on the CAN bus. Each module in a frame is permanently listening for such numbers. You can also assign GPO numbers which will indicate the respective action. E.g. if a Preset x is loaded the C8612 puts the associated GPO number on the CAN bus. The GPI/O module permanently listens for such numbers. If it reads such number it will engage the respective GPO (see C8817 manual for details).