diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for...

8
diasys diagnostic systems 15 clinical chemistry immunoturbidimetric tests instruments calibrators · standards · controls · supplementary reagents ::010 ::011 ::012 ::013 ::014 ::015 ::016 ::017 ::018 ::026 ::027 ::028 ::029 ::030 ::031 ::032 ::036 ::037 ::038 ::039 ::043 ::044 ::045 ::048 ::049 ::050 ::051 ::052 ::056 ::037 ::058 ::060 ::061 ::062 ::063 ::064 short catalogue ::065 ::066 ::067 ::068 ::069 ::070 ::071

Transcript of diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for...

Page 1: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 1

Probedruck

C M Y CM MY CY CMY K

d i a sys d i a g n o st i c syst e m s

15

clinical chemistry

immunoturbidimetric tests

instruments

calibrators · standards · controls · supplementary reagents

::010 ::011 ::012 ::013 ::014 ::015 ::016 ::017 ::018

::026 ::027 ::028 ::029 ::030 ::031 ::032

::036 ::037 ::038 ::039

::043 ::044 ::045

::048 ::049

::050 ::051 ::052

::056 ::037 ::058

::060 ::061 ::062 ::063 ::064

short catalogue

::065 ::066 ::067 ::068

::069 ::070

::071

Page 2: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 2

Probedruck

C M Y CM MY CY CMY K

02

welcome to diasysDiaSys Diagnostic Systems is a leading specialist in development and manufacturing of diagnosticsystems of high quality combined with ease of use and reduced environmental burden.

Focusing on clinical chemistry and immunoturbidimetric tests, DiaSys has introduced more than90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or automated use. The portfolio includes a broad range of appropriate calibrators and controls,as well as photometric systems and glucose/lactate analyzers. To date, customers and partnersin more than 100 countries around the world rely on DiaSys quality.

DiaSys maintains a quality management system certified according to ISO 13485/ISO 9001.

All products are CE marked according to Directive 98/79/EC.

the short catalogueThe DiaSys short catalogue 2015 provides a brief but concise outline of all available instruments,reagents for clinical chemistry and immunoturbidimetry, as well as of calibrators, controls, standardsand supplementary reagents.

how to place your orderDue to the variety of kit sizes and systems supplied, no order numbers are specified in thisshort catalogue. If you want to place an order for DiaSys products, all product information isavailable from the complete DiaSys product catalogue 2015, or please refer to to our websitewww.diasys-diagnostics.com.

system specific kitsDiaSys reagents are offered in dedicated kits for several analyzer systems. For an overview at aglance, a dot behind the respective reagent marks the suitable instrument line. Find additionalinformation about corresponding instrument lines in the footer of the page.

some abbreviations in common use

contents page

FS Fluid-stable, ready-to-use reagent

:: Clinical Chemistry 03

:: Immunoturbidimetric Tests 05

:: Calibrators/Standards 06

:: Controls/Supplementary Reagents/Special Products 07

:: Instruments 08

03

05

06

07

08

Page 3: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 3

Probedruck

C M Y CM MY CY CMY K

reagents

clin

ical

che

mis

try

a – e

Product

03

clinical chemistry

Method resp

ons®

BioM

ajes

ty®

JCA-

BM60

10/C

Mul

tiple

-pur

pose

Hita

chi 9

11

Hita

chi 9

17

ADVI

A

Pres

tige

24i

Sele

ctra

supplied systems*

* Additional information (for precise information concerning supplied analyzer types please refer to DiaSys product catalogue 2015)Multi-purpose Kits: DiaSys reagents in kits for multi-purpose and manual use - no analyzer specific bottlesKits for Hitachi 911: Full barcode; bottles suitable for several Hitachi and Olympus analyzers, ADVIA, Abbott ARCHITECT TM

Kits for Hitachi 917: Full barcode; bottles suitable for several Hitachi, Olympus, ADVIA analyzers and Modular PKit for ADVIA Systems: Full barcode; bottles suitable for ADVIA 1200/1650/1800/2400

Kit for Prestige 24i and BIOLIS 24i

Kits for Selectra Systems: Bottles suitable for Vitalab Selectra

ALAT (GPT) FS (IFCC mod.) UV test according to IFCC • • • • • •Albumin FS Bromocresol green method • • • • • •Alkaline phosphatase FS DGKC Test according to DGKC • • • •Alkaline phosphatase FS IFCC 37°C Test according to IFCC • • • • • •

-Amylase CC FS EPS-G7 method according to IFCC • • • • • •ASAT (GOT) FS (IFCC mod.) UV test according to IFCC • • • • • •ATP Hexokinase FS Enzymatic UV test using hexokinase •Bicarbonate FS Enzymatic test using NADH analogue • • • • • Bile acids Colorimetric test •Bilirubin Auto Direct FS DCA method • • • • • •Bilirubin Auto Total FS DCA method • • • • • •Bilirubin Jendrassik-Gróf FS Colorimetric test according to Jendrassik-Gróf •Calcium AS FS Arsenazo III method • • Calcium P FS Phosphonazo III method • • • • • Chloride 21 FS Advanced colorimetric test • •Cholesterol FS 5' version CHOD-PAP method •Cholesterol FS 10' version CHOD-PAP method • • • • • •Cholinesterase FS Butyrylthiocholine test according to DGKC • • • • • •CK-MB FS Test according to IFCC/DGKC • • • • • •CK-NAC FS Test according to IFCC/DGKC • • • • • •Creatinine FS Jaffé method (compensation optional) • • • • • •Creatinine PAP FS Enzymatic PAP method • • • • • •Ethanol FS Enzymatic endpoint test • • • • •

Page 4: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 4

Probedruck

C M Y CM MY CY CMY K

clinical chemistry

reagents

clin

ical

che

mis

try

g – u

04

Product Method resp

ons®

BioM

ajes

ty®

JCA-

BM60

10/C

Mul

tiple

-pur

pose

Hita

chi 9

11

Hita

chi 9

17

ADVI

A

Pres

tige

24i

Sele

ctra

supplied systems*

* Additional information (for precise information concerning supplied analyzer types please refer to DiaSys product catalogue 2015)Multi-purpose Kits: DiaSys reagents in kits for multi-purpose and manual use - no analyzer specific bottlesKits for Hitachi 911: Full barcode; bottles suitable for several Hitachi and Olympus analyzers, ADVIA, Abbott ARCHITECT TM

Kits for Hitachi 917: Full barcode; bottles suitable for several Hitachi, Olympus, ADVIA analyzers and Modular PKit for ADVIA Systems: Full barcode; bottles suitable for ADVIA 1200/1650/1800/2400

Kit for Prestige 24i and BIOLIS 24i

Kits for Selectra Systems: Bottles suitable for Vitalab Selectra

Gamma-GT FS (Szasz mod./IFCC stand.) Szasz method IFCC standardized • • • • • •GLDH FS DGKC UV test according to DGKC • • • •Glucose Gluc-DH FS Glucose dehydrogenase method •Glucose GOD FS 5' version GOD-PAP method •Glucose GOD FS 10' version GOD-PAP method • • • • Glucose Hexokinase FS Hexokinase method • • • • • HbA1c FS Enzymatic method • • • •

-HBDH FS UV test according to DGKC •HDL-C Immuno FS Direct immunoinhibition method • • • • • Hemoglobin FS Hemiglobincyanide method •Homocysteine FS Enzymatic cycling method • •

-Hydroxybutyrate FS Enzymatic method • • • •Iron FS Ferene Ferene method • • • • • •Lactate FS UV test with LDH • • • • •LDH FS DGKC UV test according to DGKC • • • •LDH FS IFCC UV test according to IFCC • • • • • •LDL-C Select FS Selective direct measurement • • • • • Lipase DC FS Enzymatic colorimetric method • • • • • •Lp-PLA2 FS Enzymatic method • •Magnesium XL FS Xylidyl blue method • • • • • •NEFA FS (Non-esterified fatty acids) Enzymatic method • • • •Pancreatic amylase CC FS EPS-G7 method • • • • •Phosphate FS UV test using molybdate • • • • • •Phospholipids FS Enzymatic colorimetric test • • •Potassium FS Enzymatic method • •Sodium FS Enzymatic method • •Total protein FS Biuret method • • • • • •Total protein UC FS Pyrogallol red method • • • •Triglycerides FS 5' version GPO method • •Triglycerides FS 10' version GPO method • • • • • UIBC FS (Unsaturated iron binding capacity) Ferene method • • • • Urea FS Urease-GLDH method • • • • • •Urea CT FS Colorimetric method (Berthelot) • •Uric acid FS TBHBA Uricase-TBHBA method • • •Uric acid FS TOOS Uricase-TOOS method • • • • • •

Page 5: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 5

Probedruck

C M Y CM MY CY CMY K

reagents

imm

unot

urbi

dim

etri

c te

sts

a – t

Product

05

Method resp

ons®

BioM

ajes

ty®

JCA-

BM60

10/C

Mul

tiple

-pur

pose

Hita

chi 9

11

Hita

chi 9

17

ADVI

A

Pres

tige

24i

Sele

ctra

supplied systems*

immunoturbidimetric tests

* Additional information (for precise information concerning supplied analyzer types please refer to DiaSys product catalogue 2015)Multi-purpose Kits: DiaSys reagents in kits for multi-purpose and manual use - no analyzer specific bottlesKits for Hitachi 911: Full barcode; bottles suitable for several Hitachi and Olympus analyzers, ADVIA, Abbott ARCHITECT TM

Kits for Hitachi 917: Full barcode; bottles suitable for several Hitachi, Olympus, ADVIA analyzers and Modular PKit for ADVIA Systems: Full barcode; bottles suitable for ADVIA 1200/1650/1800/2400

Kit for Prestige 24i and BIOLIS 24i

Kits for Selectra Systems: Bottles suitable for Vitalab Selectra

Albumin in Urine/CSF FS (Microalbumin) Immunoturbidimetric test • • • • • •Antistreptolysin O FS Particle-enhanced immunoturbidimetric test • • • • •Apolipoprotein A1 FS Immunoturbidimetric test • • • • •Apolipoprotein B FS Immunoturbidimetric test • • • • •Complement C3c FS Immunoturbidimetric test • • • •Complement C4 FS Immunoturbidimetric test • • • •CRP FS Immunoturbidimetric test • • • • • •CRP U-hs Particle-enhanced immunoturbidimetric test • • • •Cystatin C FS Particle-enhanced immunoturbidimetric test • • • •D-Dimer FS Particle-enhanced immunoturbidimetric test • • • •Ferritin FS Particle-enhanced immunoturbidimetric test • • • •Ferritin 21 FS new Particle-enhanced immunoturbidimetric test • • •Ferritin SR Particle-enhanced immunoturbidimetric test • HbA1c FS Particle-enhanced immunoturbidimetric test • • • • •Immunoglobulin A FS Immunoturbidimetric test • • • • •Immunoglobulin E FS Particle-enhanced immunoturbidimetric test • • • •Immunoglobulin G FS Immunoturbidimetric test • • • • •Immunoglobulin M FS Immunoturbidimetric test • • • • •Lp(a) 21 FS Particle-enhanced immunoturbidimetric test • • • •Myoglobin FS Particle-enhanced immunoturbidimetric test • • • •Prealbumin FS Immunoturbidimetric test • • • •Rheumatoid factor FS Immunoturbidimetric test • • • • • •Transferrin FS Immunoturbidimetric test • • • • •

Page 6: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 6

Probedruck

C M Y CM MY CY CMY K

calibrators and standardsca

libr

ator

s · s

tand

ards

06

calibrators

TruCal U Multi-calibrator for clinical chemistryTruCal E Liquid-stable multi-calibrator for electrolytesTruCal Lipid Lipid calibratorTruCal Protein Liquid-stable multi-calibrator for proteinsTruCal Protein high Liquid-stable multi-calibrator for proteinsTruCal Albumin U/CSF For use with Albumin in Urine/CSF FSTruCal Albumin U/CSF high For use with Albumin in Urine/CSF FSTruCal Apo A1/B For use with Apolipoprotein A1 FS and Apolipoprotein B FSTruCal ASO For use with Antistreptolysin O FSTruCal CK-MB For use with CK-MB FSTruCal CRP For use with CRP FSTruCal CRP 150 For use with CRP FSTruCal CRP high For use with CRP FS up to 500 mg/LTruCal CRP hs For use with CRP U-hs TruCal CRP U For use with CRP U-hsTruCal Cystatin C For use with Cystatin C FSTruCal D-Dimer For use with D-Dimer FSTruCal Ferritin For use with Ferritin FSTruCal Ferritin 21 For use with Ferritin 21 FSTruCal Ferritin SR For use with Ferritin SRTruCal HbA1c liquid For use with HbA1c FSTruCal HbA1c For use with HbA1c FSTruCal Homocysteine For use with Homocysteine FSTruCal IgE For use with Immunoglobulin E FSTruCal Lp(a) 21 For use with Lp(a) 21 FSTruCal Myoglobin For use with Myoglobin FSTruCal RF For use with Rheumatoid factor FSTruCal UIBC For use with UIBC FS

standards

Albumin Standard FS Iron Standard FSATP Standard FS Magnesium Standard FSBicarbonate Standard FS NEFA Standard FSCalcium Standard FS Phosphate Standard FSChloride Standard FS Phospholipids Standard FSCholesterol Standard FS Total protein Standard FSCreatinine Standard FS Total protein UC Standard FSEthanol Standard FS Triglycerides Standard FS (additional value for glycerol)

Glucose Standard FS Urea Standard FS-Hydroxybutyrate Standard FS Uric acid Standard FS

Page 7: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 7

Probedruck

C M Y CM MY CY CMY K

cont

rols

supp

lem

enta

ry r

eage

nts

and

spec

ial p

rodu

cts

07

controls and additional products

design 99° Grafikdesign · www.99grad.de

Urinary stone analysis Reagent kit for qualitative determination 30 determinations eachof the most important components ofurinary calculi

special products Kit size

Cleaner A Acidic cleaning solution 4 x 60 mL

Cleaner B Alkaline cleaning solution 4 x 60 mL

Cleaner 6 x 200 mL

cleaner for Kit size

controls

TruLab N "Normal" control for clinical chemistryTruLab P "Pathological" control for clinical chemistryTruLab L Lipid controlTruLab Protein Liquid-stable protein controlTruLab Urine Control for analytes in urineTruLab Albumin U/CSF For use with Albumin in Urine/CSF FSTruLab Bicarbonate For use with Bicarbonate FSTruLab CRP For use with CRP FS and CRP U-hs TruLab CRP hs For use with CRP U-hs TruLab Cystatin C For use with Cystatin C FSTruLab D-Dimer For use with D-Dimer FSTruLab Ethanol For use with Ethanol FSTruLab HbA1c liquid For use with HbA1c FSTruLab HbA1c For use with HbA1c FSTruLab Homocysteine For use with Homocysteine FSTruLab Lp(a) For use with Lp(a) 21 FS

supplementary reagents

CK-MB DS Supplementary reagent for determination of CK-MBDouble signal for increased sensitivity and precision

Glucose Hemolyzing Solution For use with Glucose Gluc-DH FS

HbA1c Hemolyzing Solution For use with HbA1c FS

HbA1c Hemolyzing Solution For use with HbA1c FS

HDL Precipitant Supplementary reagent for use with Cholesterol FS

LDL Precipitant Supplementary reagent for use with Cholesterol FS

Pyridoxal-5-Phosphate FS Supplementary reagent for IFCC recommended ASAT/ALAT determination

Cleaner 14 Alkaline cleaning solution for Selectra Systems

Page 8: diasys diagnostic systems - Sysmex · diasys diagnostic systems 15 ... 90 optimized reagents for routine and special diagnostics in user-friendly kits for manual or ... Kits for Hitachi

DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 8

Probedruck

C M Y CM MY CY CMY K

instruments

instruments

inst

rum

ents

828106 | Edition 2015 | 12-2014

DiaSys Diagnostic Systems GmbH

Alte Strasse 9 :: 65558 Holzheim/Germany

Phone +49 (0) 64 32 /91 46-0 :: Fax +49 (0) 64 32 /91 46-32

[email protected] :: www.diasys-diagnostics.com

Handed over by:

Automated bench top :: 150 tests/h (mono-reagents), 100 tests/hclinical chemistry analyzer (2-component reagents)

:: Combined reagent/sample tray for 30

reagents and 30 patient samples:: STAT-analytics possible for 2 sample

positions

Fully automated bench top :: 200 tests/h (360 tests/h with ISE) random access clinical :: STAT-sample capability

chemistry analyzer :: On-board capacity: 30 reagents:: 39 sample tray positions for samples,

calibrators and controls

Random access :: 800 tests/h (total throughput clinical chemistry analyzer 1200 tests/h with ISE)

:: 48 simultaneous assay measurements(53 with ISE)

:: Micro volume technology:: Advanced HbA1c determination

Advanced point-of-care analyzer :: Photometric measurement of HbA1c, glucose, hemoglobin and more

StarDust MC15 Semi-automated analyzer :: Photometers for measurement of substrates, enzymes, electrolytes and

immunoturbidimetric tests, including serological parameters and specific proteins

:: Fully programmable

photometric analyzers

JCA-BM6010/C*

water purification systems

MINI OP100 Up to 30 L/day :: Reverse osmosis combined withion exchange

OP101/OP101+ Up to 50 L/day :: Removal of 99 % of all contaminants:: Manometric and conductometric

OP202+/OP302+ Up to 50 – 100 L/day (OP202+) controlsUp to 150 L/day (OP302+)

* Please contact your local supplier concerning availability in your country

biosensor glucose/lactate analyzers

30 sample positions :: Biosensor technology for theColour touch screen measurement of glucose and/or lactate

:: High accuracy and excellent precisionFor single samples and small series :: Maintenance-free biosensorOptional measurement of :: Automatic calibrationhemoglobin :: Individual hematocrit correction

for whole blood samples:: Printer and EDP interface included