Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within...

30
OLAV-3 Oak Ridge July 2011 Matthew Cox Diamond Light Source, UK [email protected] Diamond Light Source Vacuum Systems: The First Four Years of User Operations 1

Transcript of Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within...

Page 1: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

OLAV-3 Oak Ridge July 2011

Matthew CoxDiamond Light Source, [email protected]

Diamond Light Source Vacuum Systems:

The First Four Years of User Operations

1

Page 2: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Topics

OLAV-3 Oak Ridge July 2011

Overview of Diamond Vacuum Systems

Operational performance

Upgrades

Challenges and issues

Future plans

2

Page 3: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

What is Diamond Light Source?

OLAV-3 Oak Ridge July 2011

• The UK national synchrotron facility, 100 km from London

• Generates brilliant beams of light, from infra‐red to hard X‐rays, 

for a range of science applications

• 3rd generation light source making heavy use of insertion devices 

in straight sections (undulators and wigglers)

• Construction began in early 2003

• User operations began in January 2007 with 7 beamlines 

operational (Phase 1)

• Now 20 beamlines operational + 2 being installed (Phase 2)

• Will increase to 32 beamlines over the next 6 years (Phase 3)

3

Page 4: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Beamline

3 GeV electron storage ring562m circumference

<10-9 mbar

Booster synchrotron

100 MeV Linac

Front end

Diamond layout

OLAV-3 Oak Ridge July 2011 4

Page 5: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Aerial view

OLAV-3 Oak Ridge July 2011 5

Page 6: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Why ultra‐high vacuum?

OLAV-3 Oak Ridge July 2011

• Storage ring• p < 10‐9 mbar• Interactions between circulating electrons and residual gas molecules

– Stored beam lifetime– Gas Bremsstrahlung radiation

• Scales as Z2 – minimise high Z gases

• Beamlines• Hydrocarbon contamination of x‐ray optics (mirrors, gratings, crystals)• Some sample environments require UHV• Gas phase absorption and scattering

• Residual gas• Hydrogen often predominant but not a problem – low Z, non‐contaminating• Water and hydrocarbons need attention

• Electrons• Disappear after use!

6

Page 7: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Storage ring vacuum engineering

OLAV-3 Oak Ridge July 2011

• High radiation environment in shielding tunnel• Materials – stainless steel, copper, ceramic• Electronics• Personnel access• Remote control and monitoring

• High heat loads and power densities – up to 30kW some insertion devices

• Locally high magnetic fields• Long narrow beam channels with little space for vacuum pumps: 

conductance limited, many pumps• High reliability

• 24/7 operation, 5 shutdowns a year

• Quality control at every stage is vital

• Protection from vacuum accidents and electron and photon beam damage is important 

7

Page 8: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Diamond Storage Ring Vacuum Equipment

OLAV-3 Oak Ridge July 2011

• Pumps– 500 Noble diode ion pumps– 50 Titanium sublimation pumps– 50 Non‐ evaporable getter (NEG) cartridge pumps– 9 NEG coated vessels– Mobile turbomolecular / scroll pump carts for interventions

• Instrumentation– 200 Inverted Magnetron Gauges (IMGs) and 200 Piranis– 80 Residual Gas Analysers (RGAs)

• Valves– 50 RF‐shielded pneumatic gate valves– 50 All‐metal pneumatic gate valves to front ends / absorbers– 150 Right‐angle manual valves

8

Page 9: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Bakeout policy

OLAV-3 Oak Ridge July 2011

Generally do not bake out in‐situCostLimited intervention timeLabour intensive and prone to human errorThermal expansionGood results achieved without in‐situ bakeout

Instead: Ex‐situ prebake and installation under dry nitrogen purgeEx‐situ bakeout typically 250°C vessel at supplier, 200°C assemblies at DiamondDry nitrogen flow helps to prevent water vapour from entering the system

In situ bake out where:Non‐evaporable Getter (NEG) coating activationWhere significant exposure to atmospheric moisture is unavoidableWhere ultimate pressure or gas composition is particularly critical

9

Page 10: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Storage ring vacuum performance

10

All vacuum systems working well. Performance within specification

3700 A.h beam conditioning dose (July 2011)

Machine has been tested at 300 mA. Routinely operating at 225 mA in top‐up mode (every 10 minutes). Short term will incrementally increase to 300 mA targeting 500 mA longer term.

Average gauge reading (nitrogen equivalent pressure)

Static pressure (no beam) 2.8 x 10‐10 mbar

Dynamic pressure at 225 mA = 4.5 x 10‐10 mbar 

Residual gas composition typically > 95% H2, balance mainly CO – (RGAs not calibrated)

Beam lifetime typically 20 h at 225 mA (not dominated by gas lifetime)

OLAV-3 Oak Ridge July 2011

Page 11: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

1.0E-12

1.0E-11

1.0E-10

1.0E-09

1.0E-08

0.0001 0.001 0.01 0.1 1 10 100 1000Beam dose (A.h)

Dyn

amic

pre

ssur

e (m

bar/m

A)

1

10

100

1000

10000

Cur

rent

x li

fetim

e (m

A.h

)

PressureLifetime

300mA 10‐9 mbar = 3.3x10‐12 mbar/mAPSD yield (η) vs dose (Γ)

follows:η ∝ Γ-0.73

OLAV-3 Oak Ridge July 2011 11

Storage ring beam conditioning

Page 12: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Operational reliability 2007 ‐ 2011

OLAV-3 Oak Ridge July 2011 12

2007 2008 2009 2010 2011 (to June 2nd)

User beam (h) 3160 4092 4536 4753 2184

Uptime (%) 92.3 94.9 96.4 97.4 98.2

MTBF (h) 10.64 14.5 21.1 27.3 48.5

MTTR (h) 0.71 0.6 0.77 0.72 0.84

Total beam trips 297 282 217 174 43

Vacuum beam trips 26 22 15 1 3

SR RF beam trips 130 171 114 112 18

Unofficial statistics!Longest stored beam with no trip 172 hours

Page 13: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Operational reliability 2010

OLAV-3 Oak Ridge July 2011 13

1 1 1

24

1 0 1 1

7

30 0

37

46

2 3

19

1

1

05

22

2

11

11

7

6

05

101520253035404550556065707580859095

100105110115120

# Tr

ipss

Groups

Beam Trips by Group During Each Run (2010)

Run 06-10

Run 05-10

Run 04-10

Run 03-10

Run 02-10

Run 01-10

Page 14: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Operations calendar 2011

OLAV-3 Oak Ridge July 2011 14

Page 15: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Main vacuum mechanical upgrades since initial build

OLAV-3 Oak Ridge July 2011

• 6 of 72 girders replaced with new builds (Synchrotron Radiation (SR) aperture, magnetic lattice)

1 x B22 IR beamline3 x I13 Double mini beta2 x I09 Double mini beta

• 21 front ends installed (17 ID, 4 BM)

• 18 of 22 insertion device straights installed 12 in-vac undulator (including 1 cryo)9 NEG coated vessel for ex-vac ID2 superconducting multipole wiggler

• 20 (+ 2 in progress) beamlines installed

• Superconducting RF cavity exchanges and pumping improvements (to reduce hydrogen cryo-pumping in cavities thought to be linked to RF breakdown events)

15

Page 16: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Main vacuum controls and equipment upgrades since initial build

OLAV-3 Oak Ridge July 2011

• Many refinements to interlock system to reduce unwanted beam trips

• Permanent magnet filters fitted to prevent stray electrons affecting IMG gauges

• Some Piranis stop working in the presence of stored beam. Thought to be RF heating but not well understood. Pirani interlocks overridden

• Development of new fast valve control system

• Introduction of new ion pump controller

• Introduction of new cold cathode / Pirani gauge controller

• Improved RGA integration with EPICS

16

Page 17: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

New girders and straight installation for I13

OLAV-3 Oak Ridge July 2011 17

New vacuum string build,bakeout and integration

on to girderOld 8.3m straight Straight vessels and

girders removed

New girder lift New girder installationNew 9.4m straight

with quadrupole magnets

Page 18: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Beam conditioning of new I13 girders and straight

1 10

0

50

100

150

200 C

urre

nt (m

A)

SR-DI-DCCT-01:SIGNAL SR-DI-DCCT-01:LIFE120 SR12A-VA-IMG-04:P

Beam dose (A.h)

0

2

4

6

8

10

12

14

16

18

20

22

Life

time

(h)

1E-9

1E-8

1E-7

p (m

bar)

Slope -0.74

1 101E -10

1E -9

1E -8

1E -7g g p p

p (m

bar)

B eam dose (A .h )

2 H 2 18 H 2O 28 C O

New 22m section of storage ringinstalled Sept 2010 (for beamlineI13)

Beam conditioning at 200 mA

Main gases: H2, CO, H2O

Pressure rise due to PSD ~10-7

mbar

PSD yield (η) vs dose (Γ) follows:

η ∝ Γ-0.74

18OLAV-3 Oak Ridge July 2011 Lifetime recovery after girder swap June 2011

Conditioning plots after girder swap Sept 2010

Page 19: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Beamline I13 vacuum layout• Complex beamline with two main 

branches (CO and IM)• External vacuum duct

• Two 150m long  x‐ray beam pipes 100 to 200 mm diameter

• Windowless• Pumped from ends only (except 

during installation)• Differential pumping to achieve 

UHV ∼5x10‐9 mbar at both ends• Exposed to ambient  

temperature variation = outgassing rate variation

• In‐situ baked• New design fast‐closing mask to 

protect normal fast‐closing valve from synchrotron radiation heating to give more vacuum protection options

OLAV-3 Oak Ridge July 2011 19

Page 20: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Beamline I13 schematic (CO branch only)

OLAV-3 Oak Ridge July 2011 20

Page 21: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Beamline I13 external duct

1.00E-09

1.00E-08

1.00E-07

1.00E-06

1.00E-05

0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 150000 160000 170000 180000 190000 200000

Pre

ssur

e (m

Bar

)

z (mm)

Ext Transfer lineOH1 OH2 OH3Int Tfr Differential pumping

OLAV-3 Oak Ridge July 2011 21

Bakeout of external vacuum duct

Measured pressure in external duct CO branch

Calculated pressure in beamline (CO and IM branches)

10‐7 mbar

Page 22: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Some accelerator component failures

Titanium coating damage inside ceramic

kicker vessel

Electrical insulation failure caused melted

hole in septum vacuum vessel (x2)

OLAV-3 Oak Ridge July 2011 22

Page 23: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Some beamline vacuum issuesBroken window on

beamline (x2)

OLAV-3 Oak Ridge July 2011 23

Failed shutter bellows after a few hundred cycles – mechanical

design error (x4)

Pressure spikes from ferrofluidic vacuum seals

Carbon deposition on x-ray optics

Page 24: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Synchrotron radiation heating damage

Melted LN2 pipe in monochromator due to undulator beam heating

OLAV-3 Oak Ridge July 2011 24

Melted hole in fast closing vacuum valve titanium plate due to undulator beam

Page 25: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Kapton insulated wire problemPressure spikes trip interlock system

Beam on only

IR mirror and x‐ray absorber in beamline 

B22

RGA

Mass 69

CF3+

OLAV-3 Oak Ridge July 2011 25

Page 26: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Kapton insulated wire problem

Kapton insulated wire contains unexpected FEP binder which 

breaks down due to scattered x‐rays

CF3+ also seen with electron irradiation (5keV) in test system

Solution: remove Kapton insulated wire near strong x‐ray beam 

absorber or scatterer

OLAV-3 Oak Ridge July 2011 26

Multiple occurrences in different front ends and beamlines

Page 27: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Future upgrades and challenges

OLAV-3 Oak Ridge July 2011

• Complete phase 2 then phase 3 and beyond:• Complex beamlines• Complex vacuum experimental stations and detectors• 7.9 m long NEG vessel for I05?• “Superbend” dipole magnet?• Additional IDs in existing straights?

• Optimisation of vacuum interlock protection system: beamline protection vs machine reliability

• Maintain and improve supplier vacuum QA for beamlines and small quantities of vessels

• One-offs of complex vessels for spares and upgrades: manufacturers maybe unable or unwilling

• Obsolescence of equipment and spares• Direct integration of RGA systems into EPICS (currently via Windows PC

intermediate)• Increase beam current to 500 mA

27

Page 28: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Summary

OLAV-3 Oak Ridge July 2011

• Diamond has a large and complex UHV system

• It is operating reliably to specification (<10‐9

mbar in the storage ring). The main residual gas is hydrogen

• Many small and medium size upgrades have been installed over the past 4 ‐ 5 years

• A number of vacuum challenges had to be solved along the way

• The journey is not over yet and there will be more challenges to come

28

Page 29: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

Acknowledgements

OLAV-3 Oak Ridge July 2011

• Diamond Technical Groups

Vacuum

Engineering

Controls

• Suppliers

• Other labs for helpful advice

29

Page 30: Diamond Light Source Vacuum systems€¦ · All vacuum systems working well. Performance within specification. 3700 A.h beam conditioning dose (July 2011) Machine has been tested

OLAV-3 Oak Ridge July 2011

Thank you

30