Diagnosis 1 v-112JA

download Diagnosis 1 v-112JA

of 10

Transcript of Diagnosis 1 v-112JA

  • 7/28/2019 Diagnosis 1 v-112JA

    1/10

    Date:5/2/2013 3:05 PM

    810 Vibration Tester Diagnostic Report

    Device Serial Number : 2178006Machine Setup Name : V-112JAMeasurement Date/Time : 05/02/2013 13:49:04Drive Train

    DiagnosisFault description Fault severity Severity Score Severity Scale

    Motor Imbalance Serious 53/100

    Imbalance Serious 53/100

    RecommendationsRecommendations Priority Priority Description

    Balance Unit 3 Important

  • 7/28/2019 Diagnosis 1 v-112JA

    2/10

    Page2

    Date:5/2/2013 3:05 PM

    Location : Location 1Range : High rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec

    Location : Location 1Range : Low rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec

  • 7/28/2019 Diagnosis 1 v-112JA

    3/10

    Page3

    Date:5/2/2013 3:05 PM

    Location : Location 1Range : High rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec

    Location : Location 1Range : Low rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec

  • 7/28/2019 Diagnosis 1 v-112JA

    4/10

    Page4

    Date:5/2/2013 3:05 PM

    Location : Location 1Range : High rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec

    Location : Location 1Range : Low rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec

  • 7/28/2019 Diagnosis 1 v-112JA

    5/10

    Page5

    Date:5/2/2013 3:05 PM

    Location : Location 2Range : High rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec

    Location : Location 2Range : Low rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec

  • 7/28/2019 Diagnosis 1 v-112JA

    6/10

    Page6

    Date:5/2/2013 3:05 PM

    Location : Location 2Range : High rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec

    Location : Location 2Range : Low rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec

  • 7/28/2019 Diagnosis 1 v-112JA

    7/10

    Page7

    Date:5/2/2013 3:05 PM

    Location : Location 2Range : High rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec

    Location : Location 2Range : Low rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec

  • 7/28/2019 Diagnosis 1 v-112JA

    8/10

    Page8

    Date:5/2/2013 3:05 PM

    Fault description : Motor ImbalanceFault severity : Serious (53)Cited peak number Bearing Axis Vibration amplitude Order Range

    Cited peak1 Location1 Tangential 16.30 mm/sec 1 Low

    Cited peak2 Location2 Tangential 12.78 mm/sec 1 Low

    Cited peak3 Location1 Radial 3.60 mm/sec 1 Low

    Cited peak4 Location1 Axial 1.72 mm/sec 1 Low

    Cited peak5 Location2 Radial 1.28 mm/sec 1 Low

    Cited peak6 Location2 Axial 1.17 mm/sec 1 Low

  • 7/28/2019 Diagnosis 1 v-112JA

    9/10

    Page9

    Date:5/2/2013 3:05 PM

    Fault description : ImbalanceFault severity : Serious (53)Cited peak number Bearing Axis Vibration amplitude Order Range

    Cited peak1 Location1 Tangential 16.30 mm/sec 1 Low

    Cited peak2 Location2 Tangential 12.78 mm/sec 1 Low

    Cited peak3 Location1 Radial 3.60 mm/sec 1 Low

    Cited peak4 Location1 Axial 1.72 mm/sec 1 Low

    Cited peak5 Location2 Radial 1.28 mm/sec 1 Low

    Cited peak6 Location2 Axial 1.17 mm/sec 1 Low

  • 7/28/2019 Diagnosis 1 v-112JA

    10/10

    Page10

    Date:5/2/2013 3:05 PM

    Machine Setup DetailsMachine Setup Name : V-112JASetup Field Input

    Motor type AC

    AC motor with VFD No

    Speed in RPM 1780

    Nominal kw 74.57

    Motor mounted Vertical

    Motor has Roller bearing

    Motor detached from drive train No

    Motor close-coupled Yes

    Motor directly bolted to Centrifugal pump

    No. of pump vanes [optional]