DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with...

8
DFX-MM series The Ultrasonic Flow Meter for Liquid Hydrocarbons Custody Transfer Application 09/04/2008 Page1 L002B DFX-MM leaflet Now the multipath liquid UFM's keep their performance promises 32 Beams 32 Beams

Transcript of DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with...

Page 1: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

DFX-MM series

The Ultrasonic Flow Meterfor Liquid Hydrocarbons Custody Transfer Application

09/0

4/2

008 P

age1

L002B D

FX-M

M lea

flet

Now the multipath liquid UFM's keep their performance promises

32 Beams

32 Beams

Page 2: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

09/0

4/2

008 P

age2

L002B D

FX-M

M lea

flet

DFX-MM features & benefits

PerformanceA master meter class UFM exceeding current

standards from 0.2 to 200 cSt

Superior linearity and repeatability thanks to

unequalled spatial scanning and ultra-fast scanning

rate

compliant with OIML R117 class 0.3, M.I.D.

2004/22/EC and API MPMS Ch5.8

Truly Provable with standard turbine prover loops

Design32-beams protected design

Transit time operating principle

Unique 22.5° axial symetry with excentration design

for really much less sensitivity to flow profile

disturbances

Small volume transducers cavities minimize the

scaling effects and avoid gas pockets

InstallationReduced straight runs installation possible

Compact integrated electronics for easy site

commissioning and start-up

CommunicationHigh integration to common flow computers.

Secure ethernet communication

HTML-based configuration and auditing software with

open communication protocol for on-line remote

technical support

Powerfull flow imaging capability

ServiceUltrasonic paths redundancy allows scheduled site

maintenance and downtime reduction.

Transducers exchangeable without recalibrating the

meter

DFX-MM applications

FSO's & FPSO's custody transfer (Crude

oil)

On and Offshore allocation metering

(Crude oil, condensates)

Pipeline metering stations (Crude Oil,

Refined products)

Tanker loading / offloading terminals

(Crude Oil, Refined products,

Petrochemicals)

Storage management (Crude Oil,

Refined products, Petrochemicals)

Page 3: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

DFX-MM performance comparison with other UFM's

2 4 6 8 10 12 14 16 181

10

100

Recommended Prover Volume v/s Meter Size

API MPMS chapter .5-8 recommendationConventional UFM #1 Conventional UFM #2DFX-MM proving requirements

Meter Size ( inch )

Pro

ver

Volu

me (

m3 )

DFX-MM proving volume comparison with other UFM's

1 000 10 000 100 000 1 000 0000,980

0,985

0,990

0,995

1,000

1,005

1,010

1,015

1,020

Typical Meter Factor v/s Reynolds Number for different UFM patterns.

32-beams DFX meter8'' 4-beams parallel UFM8'' Star UFM8" Helical turbine meter

Reynolds Number

Mete

r Fact

or

DFX-MM is the only UFM with a stable meter factor over a wide Reynolds range and therefore is ideal for multiproduct pipelines and crude oils with viscosity variation.

DFX-MM requires much less prove volume than other UFM's and therefore is truly provable with standard turbine prover loops where other UFM's definitively should be proved by master meter method.

09/0

4/2

008 P

age3

L002B D

FX-M

M lea

flet

Page 4: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

DFX-MM calibration curves

DFX-MM sustains a premium +/- 0.10 % accuracy with a constant K-Factor over a wide range of viscosities and of operating conditions.

09/0

4/2

008 P

age4

L002B D

FX-M

M lea

flet

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 20000,990

0,991

0,992

0,993

0,994

0,995

0,996

0,997

0,998

0,999

1,000

1,001

1,002

1,003

1,004

1,005

1,006

1,007

1,008

1,009

1,010

DFX-MM 08'' : baselinesFlowstraightener 7 D long, ball prover volume 10m3

JET FUEL 5,0 cst 17 °C Water 6%JET FUEL 4,5 cst 24 °CJET FUEL 4,5 cst 24 °C Ball valve 40% closedGASOIL 8,4 cst 18 °CGASOIL 8,4 cst 18 °C Ball valve 40% closedOIL 15,5 cst 22 °COIL 62,0 cst 16 °CSame oil, no flow conditioner

Flowrate

Mete

r Fa

cto

r

2 000 20 000 200 000 2 000 0000,990

0,991

0,992

0,993

0,994

0,995

0,996

0,997

0,998

0,999

1,000

1,001

1,002

1,003

1,004

1,005

1,006

1,007

1,008

1,009

1,010

DFX-MM 08'' : baselines v/s Reynolds NumberFlowstraightener 7 D long, ball prover volume 10m3

JET FUEL 5,0 cst 17 °C Water 6%JET FUEL 4,5 cst 24 °CJET FUEL 4,5 cst 24 °C Ball valve 40% closedGASOIL 8,4 cst 18 °CGASOIL 8,4 cst 18 °C Ball valve 40% closedOIL 15,5 cst 22 °COIL 62,0 cst 16 °CSame oil, no flow conditioner

Reynolds Number

Mete

r Fa

cto

r

Page 5: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

DFX-MM software

DFX-MM is accurate from low to very high velocities (up to 20 meters/second) and therefore gives versatility to your metering operations.

DFX-MM accurately measures viscous flows even with no flow conditioner and therefore is ideal when pressure drop is the concern.

DFX-MM interfacing is easy and cost effective thanks to its Web server and Ethernet link,making skid commissioning, meter health check and auditing operations straightforward.

DFX-MM calibration curves

09/0

4/2

008 P

age5

L002B D

FX-M

M lea

flet

0 200 400 600 800 1000 1200 14000,992

0,993

0,994

0,995

0,996

0,997

0,998

0,999

1,000

1,001

1,002

1,003

1,004

1,005

1,006

1,007

1,008

DFX-MM 08'' : HEAVY OIL baselines

Flowstraightener 7 D long (With & Without), ball prover volume 10m3

OIL 62,0 cst 16 °CSame oil, no flow conditioner

Flowrate m3/hr

Mete

r Facto

r

0 200 400 600 800 1000 1200 1400 1600 1800 20000,992

0,993

0,994

0,995

0,996

0,997

0,998

0,999

1,000

1,001

1,002

1,003

1,004

1,005

1,006

1,007

1,008

DFX-MM 08'' : LOW VISCOSITY baselinesFlowstraightener 7 D long, ball prover volume 10m3

JET FUEL 5,0 cst 17 °C Water 6%JET FUEL 4,5 cst 24 °CJET FUEL 4,5 cst 24 °C Ball valve 40% closedGASOIL 8,4 cst 18 °CGASOIL 8,4 cst 18 °C Ball valve 40% closed

Flowrate m3/hr

Me

ter

Fa

ctor

Page 6: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

Nominal flow-rangesfor standard accuracy +/-0,15%

Meter size Flow rate (m3/h) Flow rate (BPH)

Inch mm Min. Max. Min. Max.

4'' 100 15 350 94 2201

6'' 150 30 800 189 5032

8'' 200 60 1400 377 8806

10'' 250 90 2200 566 13838

12'' 300 130 3200 818 20127

14'' 350 160 3800 1006 23901

16'' 400 200 5000 1258 31449

18'' 450 250 6200 1572 38997

20'' 500 350 7800 2201 49061

24'' 600 500 11000 3145 69188

Length & Weight*

Meter size Meter length Weight (Kg) Weight (lb)

Inch mm Inch mm # 150 # 300 # 600 #900 # 150 # 300 # 600 # 900

4'' 100 16 406 44 53 63 75 97 117 139 165

6'' 150 18 457 70 87 112 146 154 192 247 322

8'' 200 20 508 103 127 166 234 227 280 366 516

10'' 250 22 559 136 178 259 300 392 571

12'' 300 24 610 193 242 318 425 534 701

14'' 350 28 711 262 346 474 578 763 1045

16'' 400 30 762 346 443 654 763 977 1442

18'' 450 32 813 443

20'' 500 32 813 535

24'' 600 36 914 645

Note : given length are for face to face flanges

Nominal flow-rangesfor premium accuracy +/-0,1%

Meter size Flow rate (m3/h) Flow rate (BPH)

Inch mm Min. Max. Min. Max.

4'' 100 30 300 189 1887

6'' 150 65 650 409 4088

8'' 200 120 1200 755 7548

10'' 250 200 2000 1258 12580

12'' 300 300 3000 1887 18869

14'' 350 320 3200 2013 20127

16'' 400 400 4000 2516 25159

18'' 450 520 5200 3271 32707

20'' 500 650 6500 4088 40884

24'' 600 950 9500 5975 59753

09/0

4/2

008 P

age6

L002B D

FX-M

M lea

flet

DFX-MM performances & datas

Page 7: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

METROLOGY Compliances : OIML R117 class 0.3

API MPMS ch5.8M.I.D. 2004/22/EC

Accuracy : +/- 0,15% from 0.5 to 12 m/s +/- 0,10% from 1 to 10 m/s

Repeatability : provable, 0.05% 5 runs with conventional prover loops

Installation :7 D upstream with recommended flow conditionner + 3 D downstream 15 D upstream without flow conditionner + 5 D downstream

CERTIFICATIONS compliant with all relevant European Community standards

Safety : ATEX 94/9/EC pressure : P.E.D. 97/23/EC

ASME B31.3Metrology : M.I.D. 2004/22/EC (pending)

Environment : E.M.C 89/336/ECIngress protection : I.P. IEC529

ENVIRONMENT Temperature : process : -55°C to + 120°C

ambient: -40°C to + 55°CPressure : Up to 100 barViscosity : 0.3 to 200 centistockes

Density : 400 to 1500 kg/m3

BODY Materials : Carbon steel, Low temp carbon steel, Stainless steel

Flanges : ANSI #150 #300 #600 SO RF SSF

Internal : full bore

CONVERTERPower supply : 110 / 220 VAC 50/60 Hz or 18 / 32 VDC, 15W

Pulse volume output : two open-collectors 30V 0.5A isolation 1500V Communication port : embedded secured HTTP server + IEEE 802.3 Ethernet link

Please contact M&T for specifications outside above standard ones

09/0

4/2

008 P

age7

L002B D

FX-M

M lea

flet

DFX-MM specifications

Page 8: DFX-MM spdfs.findtheneedle.co.uk/17128..pdf · 2004/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design ... API MPMS chapter .5-8 recommendation Conventional

A B - C D - E F - G H

DFX-MM 12 - A 1 - 1 1 - 1 0

METERING & TECHNOLOGY S.A.S.- S.A.S. au capital de 37 500 € - R.C.S. 494 307 457 Chartres - TVA FR60494307457 - www.mnt-sas.com

Rue des 4 Filles BP 50007 28231 EPERNON Cedex FRANCE Tel: +33 (0) 965 027 803 / 237 835 446 Fax: +33 (0) 237 835 547 E.mail : [email protected]

DFX-MM ordering contacts

Section A : Product line

DFX-MM

Section B : Meter Size

04 4'' / DN100

06 6'' / DN150

08 8'' / DN200

10 10'' / DN250

12 12'' / DN300

14 14'' / DN350

16 16'' / DN400

18 18'' / DN450

20 20'' / DN500

24 24'' / DN600

Section C : Pressure Class

A 150# ANSI R.F. Flanges

B 300# ANSI R.F. Flanges

C 600# ANSI R.F. Flanges

D Other (please contact us)

Section D : Materials of construction

Body Flanges Internals

1 C.S A106 C.S A105 SS 316L

2 L.T.C.S. A333 Gr6 L.T.C.S. A350 LF2 SS 316L

3 SS 316L SS 316L SS 316L

4 Other Other Other

Section E : Installation conditions

1 Standard with recommended flow straightener

2 Standard without flow straightener

3 Customized

Section F : Accuracy class

1 standard +/-0.15%

2 premium +/-0.1%

Section G : Documentation

0 None

1 Standard

2 Customized

Section H : Special request

0 None

S Special request

METERING & TECHNOLOGY S.A.S.Adress : Rue des 4 Filles BP 50007 28231 EPERNON Cedex FRANCE Tel: +33 (0) 965 027 803 / 237 835 446Fax: +33 (0) 237 835 547E.mail : [email protected] : www.mnt-sas.com

09/0

4/2

008 P

age8

L002B D

FX-M

M lea

flet

DFX-MM ordering codes