Development of a Low Cost 3-10kW Tubular SOFC Power...

32
Development of a Low Cost 3-10kW Tubular SOFC Power System Norman Bessette Acumentrics Corporation June 10, 2010 This presentation contains no proprietary, confidential, or otherwise restricted information FC032

Transcript of Development of a Low Cost 3-10kW Tubular SOFC Power...

Page 1: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Development of a Low Cost 3-10kW Tubular SOFC Power System

Norman BessetteAcumentrics Corporation

June 10, 2010

This presentation contains no proprietary, confidential, or otherwise restricted information

FC032

Page 2: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

• ~ 95 Employees• Manufacturing since 1994•Based in Westwood, Mass.•~40,000 sq. ft facility• Critical disciplines in-house

Electrical EngineeringMechanical EngineeringChemical EngineeringThermal ModelingCeramics ProcessingManufacturingSales & MarketingAutomationFinance

Strategic Partners

Acumentrics Corporation

Page 3: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Uninterruptible Power Supplies for Harsh Environments

Features:• Sealed electronics• Able to withstand vibration• Unity power factor input• Wide input 80VAC - 265VAC• Isolated 120 / 240VAC output• Hot swap battery case• Parallelable to 20 kWatts

Acumentrics Battery-based UPS

Page 4: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Solar Flare Tests RUPS at 170˚F for 16 hours

General Atomics SkyWarrior

Page 5: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Overview

TimelineProject Start: 4/1/2008Project End: 9/30/2011Percent Complete: 60%

BarriersCell Power DensityStack Power DensityCell Cost ReductionSystem Cost ReductionSystem EfficiencyLifetime

BudgetProject Funding

DOE Share=$11,692,737Contractor=$3,897,579

Funding Received$6,695,325

Page 6: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Objectives

Improve Cell Power & Stability

Cost Reduce Cell Manufacturing

Increase Stack & System Efficiency

Develop ability to operate on liquid fuels (funded through ONR & DOD)

Integrate to remote power, military, and mCHP platforms to allow short, medium, and longer term market penetrations

Page 7: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Technical Approach

Perfect the individual System pieces followed by optimizing their integration:Cell Technology: Improve power & stability of the cell building blockCell Manufacturing: Improve processing yield & productivity while decreasing material consumptionStack Technology: Refine stack assembly and improve heat removal and integrity while cost reducing componentsSystem Performance: Develop simplified controls and BOP to allow for a reliable, highly efficient unit.

Page 8: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Cell Performance Progress

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80

Current density (A/cm2)

Pote

ntia

l (Vo

lts)

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

Pow

er d

ensi

ty (W

/cm

2 )

March 2010, 800°C

Year 2009, 800°C

Feb. 2010, 800°C

Feb. 2010, 750°C

April 2010, 750°C

615mW/cm2 @ 0.5V, 75%

Page 9: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Cell Performance Progress

0.072

0.099

0.261

0.339

0.421

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

Pow

er D

ensi

ty a

t 0.7

V, 8

00o C

, W c

m-2

2004 2005 2006 2009 2010

24% Gain Since 2009 Meeting

Page 10: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power
Page 11: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

EERE Funded Program Status

Achieved passage of BP1/BP2 “Go/No-Go” test in June 2009

Demonstrated over 40% net AC on both steam reformed & advanced generator systems

Significantly increased power per cell.

Reduced operating temperature by 100C and potential for 200C

Developed reduced recuperator cost and flexible design through this program and DOE Heat Exchanger SBIR.

Page 12: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Goal: 1500hr operation with <1%/500hr degradation rate

Setup:1kW nominal-Previously had ~473hrs operation-Hour-averaged data shown

0.9%/1000hr(0.7%/1000hrcounting starting hours)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 200 400 600 800 1000 1200 1400 1600 1800Elapsed Time, hr

DC

Pow

er, k

W; E

ffici

ency

, [1]

0

100

200

300

400

500

600

700

800

900

Tem

perature, C

DC PowerEfficiencyTemperature

Page 13: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

System Operation

Tubular CellsInherent strength and tolerance to rapid temperature change

High Operating Temperature (800 C)

Internal fuel reforming and cogeneration opportunity

Standard Manufacturing Process

Low capex Standard Components

Standard HVAC balance-of-plant componentsLeverage 12 years DC/AC conversion experience

Page 14: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Stack Design

Cathode Air Downcomer

Offgas Injectors

Fuel Plenum

Offgas Plenum

Cathode Air Distribution Region

CatyliticOxidation Tile

Cathode Air to and from Recuperator

Anode Gas Inlet

Cathode Air Downcomer

Offgas Injectors

Fuel Plenum

Offgas Plenum

Cathode Air Distribution Region

CatyliticOxidation Tile

Cathode Air to and from Recuperator

Anode Gas Inlet

Page 15: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Recuperator Reductions

100 cu. in.3.8 lbs

300 cu. in.17.8 lbs

REQUIREMENTS•Exhaust Inlet Temperature: 850 - 950C

•Air Outlet Temperature: 725 - 800 C

•Effectiveness: >85%

•Total Pres Drop: 1250 Pa

•Equal Air & Exhaust Flows

•Air Flow – 150 Slpm/ kWe

•100,000+ Hours & Hundreds of Thermal Cycles

Page 16: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Improvements in Generator Design

0

20

40

60

80

100

120

140

160

0 200 400 600 800 1000 1200

Current Density (mA/cm2)

Pow

er/C

ell (

W)

0%

10%

20%

30%

40%

50%

60%

Cel

l Effi

cien

cy (%

DC

/LH

V)

122W/Cell

65W/cell

10W/cell

2009 Cells

2010 Cells

Generator Design2009

Generator Design2010

Latest Cell Design

6x decrease in cell count at 40% efficiency

Latest Generator Design

2x decrease in cell count for 40% efficiency

Page 17: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Fuel Cell Manufacturing

Isostatic Press Automated dip-coating

Plasma spray

Automated CathodeCoating

High Temperature Firing

• Facility Capable of >300kW/yr• Cell Cost down 55% since 2009

review• Down 67% material, 45% labor• Cell Power up >100%/cell

Page 18: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Relevance to EERE Stationary Milestones

Efficiency proven over 40% on stack. Demonstrate system in 2010/2011

CHP efficiency of 85% proven on 1kWe wall hung systems

Demonstrated start-up and load transients as part of ONR liquid fuels testing

Latest generation systems operated with stacks over 5000hrs and total system tests over 8000hrs

2008 Status 2012 2015 2020Acumentrics Present Status

Electrical efficiency at rated power 34% 40% 42.50% 45% 35-40%CHP energy efficiency 80% 85% 87.50% 90% 85%Factory cost $750/kW $650/kW $550/kW $450/kWTransient response (10%- 90% rated power) 5 min 4 min 3 min 2 min <3 minStart-up time from 20°C ambient temperature 60 min 45 min 30 min 20 min 25 minDegradation with cycling < 2%/1000 h 0.7%/1000 h 0.5%/1000 h 0.3%/1000 h <1%/1000hOperating lifetime 6,000 h 30,000 h 40,000 h 60,000 h >5000hSystem availability 97% 97.50% 98% 99% 99%

Page 19: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Products

Page 20: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Remote Power System Specifications

500 W DC / Load following capability / Natural Gas, propane fueledElectrical Efficiency of 20-35%

14” 26”

14”

2.9ft3

60-70lbs

Previous GenerationSize: 22” x 22” x 33”, 220lbs, 9.2ft3 Present Generation

68% weight reduction

70% weight reduction

Page 21: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power
Page 22: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Environmental Testing

Operating at various ambient temperatures up to 45 degrees C >5000hrs.

Page 23: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

JP-8 Fueled 10kW Generator

Desulfurizer

108 cellstack

Cathode Air

Electronics

Condenser

Pre cooler

Batteries

40kWT reformer

Filter

Page 24: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power
Page 25: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

mCHP vs. power plant and (condensing) boiler

Power plant heating

Primary energy 100%

Primary energy100%

Losses

Losses

72% useful energy

90% useful energy

Losses

microCHP

microCHPsimultaneous power and heat production

Common technologyseparate power and heat production

20%power

70%heat

56%heat

16%power24%

4%

10%

60%40%

= 10 – 25% lower primary energy consumption= 10 – 25% lower CO2 emissions = 10 – 25% lower energy cost

Page 26: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

1kW Home CHP Appliance

25% energy savingsDemo with major European utilitiesFollow-on work under EFESO programNeed to integrate latest Cell technology

1 Booster Boiler2 Fuel Cell Stack3 Exhaust Heat Exchanger4 Fuel desulfurizer

Page 27: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Collaborations - EFESO Program

Enviromentally Friendly Energy from Solid Oxide fuel cellItalian government program granted to Ariston thermal group and 15 partners including Acumentrics.Acumentrics is the first foreign company to be issued an Italian government grant for a green energy programHeavily dependent upon the previous and future support of the U.S. DOE.Three year, $1.1M program culminating in a 1kWel and 2.5kWel mCHP prototype.Brings in key technology contributors on inverters, balance of plant components, testing labs/Universities and certifying bodies

Page 28: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Ariston Wall Mounted mCHP

One kilowatt unit with 20 kW thermal boilerHuge achievement to meet space and weight requirements80-90% total efficiency, 33”x22”x18”180lb total, 100lb FC sys

Page 29: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

mCHP Appliance

Fuel Cell

Recuperator

Peak Boiler Inverter

DC/DC Converter

BatteriesDesulfurizer

ID Fan

Controller

2kW Electrical/30kW thermalOn-demand hot waterCondensing Boiler40%electrical, 85-90% total efficiency

Page 30: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Proposed Future Work

Assure cell stabilityCorrelate stability vs. current densityDemonstrate stability over thermal cycles

Resolve thermal issues in stack due to higher power densityTest improved thermal management techniquesCompare results of CPOX and steam reformed systems

Continue cost reductions on each product platformContinue cell manufacturing automationContinue “make/buy” decisions on generator and BOP components

Page 31: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Summary

Significant progress in cell power enhancement

Advanced Cell Manufacturing automation & material reduction while increasing cell performance.

Significant progress in stack size & weight

Demonstrated stable system operation in real world conditions for >5000hrs.

Defined a path to market entry for the short, medium, and long term.

Page 32: Development of a Low Cost 3-10kW Tubular SOFC Power Systemhydrogendoedev.nrel.gov/pdfs/review10/fc032_bessette_2010_o_web.pdf · Development of a Low Cost 3-10kW Tubular SOFC Power

Thanks to

Reginald Tyler of the DOE-Golden Office

Dimitrios Papageorgopoulos -DOE EERE

Thomas Benjamin-Argonne National Laboratory

Don Hoffman, John Heinzel, Ed House - ONR

Ariston Thermal Group

Technical Staff at Acumentrics