DEVELOPMENT APPLICATION - City of Clarence...Nov 27, 2019  · 2826to c/lofp ipe 4 0 0 m in im u m...

5
DEVELOPMENT APPLICATION PDPLANPMTD-2019/004598 APPLICANT: Ronald Young & Co Builders PROPOSAL: Dwelling LOCATION: 3 Carpenter Circle, CLARENDON VALE RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015 ADVERTISING EXPIRY DATE: 27 November 2019 In addition to the Application Form(s), Certificate of Title(s) and any associated consent documents the following information is available on request: Nil The relevant plans and documents can be inspected at the Council offices, 38 Bligh Street, Rosny Park, during normal office hours until 27 November 2019. Any person may make representations about the application to the General Manager, by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to [email protected]. Representations must be received by Council on or before 27 November 2019. To enable Council to contact you if necessary, would you please also include a day time contact number in any correspondence you may forward. Any personal information submitted is covered by Council’s privacy policy, available at www.ccc.tas.gov.au or at the Council offices.

Transcript of DEVELOPMENT APPLICATION - City of Clarence...Nov 27, 2019  · 2826to c/lofp ipe 4 0 0 m in im u m...

Page 1: DEVELOPMENT APPLICATION - City of Clarence...Nov 27, 2019  · 2826to c/lofp ipe 4 0 0 m in im u m 400 minimum P R E L I M I N A R Y 2 6 1 5 3 9 9 9 stormwater shc SWMH p a l i n g

DEVELOPMENT APPLICATION

PDPLANPMTD-2019/004598

APPLICANT: Ronald Young & Co Builders

PROPOSAL: Dwelling

LOCATION: 3 Carpenter Circle, CLARENDON VALE

RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015

ADVERTISING EXPIRY DATE: 27 November 2019

In addition to the Application Form(s), Certificate of Title(s) and any associated

consent documents the following information is available on request:

• Nil

The relevant plans and documents can be inspected at the Council offices, 38 Bligh

Street, Rosny Park, during normal office hours until 27 November 2019.

Any person may make representations about the application to the General

Manager, by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to

[email protected]. Representations must be received by Council on or before

27 November 2019.

To enable Council to contact you if necessary, would you please also include a day

time contact number in any correspondence you may forward.

Any personal information submitted is covered by Council’s privacy policy, available

at www.ccc.tas.gov.au or at the Council offices.

Page 2: DEVELOPMENT APPLICATION - City of Clarence...Nov 27, 2019  · 2826to c/lofp ipe 4 0 0 m in im u m 400 minimum P R E L I M I N A R Y 2 6 1 5 3 9 9 9 stormwater shc SWMH p a l i n g

2826 to c/l of pipe

400 minim

um

400 minimum P R E

L I M I N A

R Y

2

6

51

3

9

9 9

shc

SWMH

palin

g fen

ce

FP

SV

SV

lid 49.03

SMH

pit

telstra

turret

aurora

meter

water

C I R C L E

C A R P E N T E R

Height Datum is AHD

Contour Survey

Scale: 1:200

Contour Interval: 0.2 m

be natural grey concrete by builder.

into stormwater. Driveway and path to

spoon drain into grated pit. Connect pit

spoon drain to side of driveway. Connect

crossover to garage entrance. Provide

Approximately 1:15 upslope from

DRIVEWAY INFORMATION

48

8

10

11

geofabric sock

1% gradient inside

Ag. drain @ min.

approved by a qualified engineer.

AS/NZS3500, 2015 and to be inspected and

All materials and construction to comply with

Crushed rock

Pervious backfill

Embankmentaway from footings

Provide 5% fall

100 dia

40 dia

50 dia

40 dia

50 dia

50 dia

50 dia

TAP CHARGED ORG min. 150mm below FFL

DOWNPIPE

DRAINAGE LEGEND

1 WC

2 HANDBASIN

3 SHOWER

4 BATH

5 LAUNDRY TROUGH

6 KITCHEN SINK

7 VENT

8

9

10

90 dia

TAP

f/w

11 INSPECTION OPENING TO GROUND LEVEL

FLOOR WASTE

stormwater

pit to connect into

450 square grated

spoon drain

opening at one end.

cut. Fall to inspection

Ag. drain to base of

stormwater

connect into

hot water to

Overflow from

stormwater

connect into

pump units to

Drain from heat

stormwater

to connect into

100 UPVC pipe

swhcsewer

to connect into

100 UPVC pipe DRAINAGE EASEMENT 3.00 WIDE

09DWG No:

DRAWN BY:

FILE NAME:

DATE:

DRAWING:

PC

Compliance No. CC102Y - James Collins

of Ronald Young & Co Builders Pty Ltd

be reproduced without the written consent

© This document is copyright and may not

...........................................................

DATE:

...........................................................

SIGNATURE:

requirements / approvals).

the client (with exception of Council

permitted after plans are signed by

PLEASE NOTE: no variations will be

...........................................................

THIS PLAN IS ACCEPTED BY:

DRAINAGE PLAN

Scale 1:200

N

423m²

C.T. No. 163056/9

Overlay

Interim Planning Scheme

As shown in the Clarence

NOT BUSHFIRE PRONE

AT 3 CARPENTER CIRCLE, CLARENDON VALE

PROPOSED DWELLING FOR MISSION AUSTRALIA HOUSING 2003 BA 190819.dgn

26/08/19

Changes as described on Cover Sheet

REVISION DATE

DESCRIPTION

A

26 August 2019

Page 3: DEVELOPMENT APPLICATION - City of Clarence...Nov 27, 2019  · 2826to c/lofp ipe 4 0 0 m in im u m 400 minimum P R E L I M I N A R Y 2 6 1 5 3 9 9 9 stormwater shc SWMH p a l i n g

1500

1500 side setbac

k

4695 side setbac

k

2826 to c/l of pipe

4500 front setb

ack (to column

)

5645 front setb

ack (to wall)

5585 to wall

5105 re

ar setbac

k (to our

door livin

g post)

P R E

L I M I N A

R Y48

shcswhc

SWMH

DRAINAGE EASEMENT 3.00 WIDE

palin

g fen

ce

FP

SV

SV

lid 49.03

SMH

pit

telstra

turret

aurora

meter

water

C I R C L E

C A R P E N T E R

Max. 1:10 slope

Min. 4m wide

Min. 24m² POS

Height Datum is AHD

Contour Survey

Scale: 1:200

Contour Interval: 0.2 m

be natural grey concrete by builder.

into stormwater. Driveway and path to

spoon drain into grated pit. Connect pit

spoon drain to side of driveway. Connect

crossover to garage entrance. Provide

Approximately 1:15 upslope from

DRIVEWAY INFORMATION

wing fence

wing fence

max. 1:10 gradient.

POS does not exceed

Grade cut to ensure that

NOTE:

Cut @

48.00

FFL @ 48.20

Parking 1

Parking 2

01Scale 1:200

423m²

DWG No:

Changes as described on Cover SheetSITE PLAN

N

DRAWN BY:

FILE NAME:

DATE:

DRAWING:

PC

Compliance No. CC102Y - James Collins

of Ronald Young & Co Builders Pty Ltd

be reproduced without the written consent

© This document is copyright and may not

...........................................................

DATE:

...........................................................

SIGNATURE:

requirements / approvals).

the client (with exception of Council

permitted after plans are signed by

PLEASE NOTE: no variations will be

...........................................................

THIS PLAN IS ACCEPTED BY:

C.T. No. 163056/9

Overlay

Interim Planning Scheme

As shown in the Clarence

NOT BUSHFIRE PRONE

AT 3 CARPENTER CIRCLE, CLARENDON VALE

PROPOSED DWELLING FOR MISSION AUSTRALIA HOUSING 2003 BA 190819.dgn

19/09/19

Changes as described on Cover Sheet

REVISION DATE

DESCRIPTION

A

B 19 September 2019

26 August 2019

Page 4: DEVELOPMENT APPLICATION - City of Clarence...Nov 27, 2019  · 2826to c/lofp ipe 4 0 0 m in im u m 400 minimum P R E L I M I N A R Y 2 6 1 5 3 9 9 9 stormwater shc SWMH p a l i n g

250350090510901440901500906003000903400250

250350090510903030903600903400250

23001260024008900

250

3200

90

2590

2520

250

250

3200

90

1200

600

90

3220

250

5200

3700

1500

250

3200

250

250

3520

90

1500

90

900

90

1220

90

900

250

250

3520

90

1500

90

2400

800

250

250

3220

90

600

1200

90

1100

90

2010

250

23002506600905410250

23002304530902000905410250

1200

5950

2800

150

250

8400

250

230602090271033002502400

149002400P R E

L I M I N A

R Y

870

870870

870

870

wm

f/w

870

shower

1200

to kitchen joinery design

For kitchen details refer

NOTE: refm/h

HW

Heat Pump

Outdoor Unit

Meter Box

Dining

Living

Bedroom 2 Bedroom 1Bathroom / Laundry

Linen

Garage

Kitchen

Porch

Robe

Robe

Robe

2700 wide garag

e door

Robe

RobeRobe

Hall

Robe

Hall

Robe

Robe

Kitchen Garage

Linen Hall / Entry PorchLiving

Hall / Entry

Living Bedroom 2 Laundry Bedroom 1

Bathroom / Laundry

Hall

Bedroom 2

Living / Dining

Bedroom 2

Kitchen

Kitchen

Linen

Bedroom 1

Porch

Lau

ndry

Bathroom

Entry

Garag

e

Linen

Garag

e

P

20-09AW (dg)

01

W

10-15AW (dg)

02

W

20-0

6A

W (dg)

03W

20-0

6A

W (dg)

04W

15-18AW (dg)

06

W

20-1

8A

W (dg)

07W

d.p.

d.p.

Outdoor Living

05

A

conditioned spaces

between garage and adjacent

Provide R2.5 wall insulation

21-2

4SD (dg)

08W

870

d.p.

10-12AW (dg)

05

W

DiningOutdoor Living

Outdoor Living

FFL 48.20

Entry

Living

Outdoor

Scale 1:100 02DWG No:

FLOOR PLAN

DRAWN BY:

FILE NAME:

DATE:

DRAWING:

PC

Compliance No. CC102Y - James Collins

of Ronald Young & Co Builders Pty Ltd

be reproduced without the written consent

© This document is copyright and may not

...........................................................

DATE:

...........................................................

SIGNATURE:

requirements / approvals).

the client (with exception of Council

permitted after plans are signed by

PLEASE NOTE: no variations will be

...........................................................

THIS PLAN IS ACCEPTED BY:

Outdoor Living Area = 7.9m²

Porch Area = 3.8m²

Floor Area = 120.7m²

N

Overlay

Interim Planning Scheme

As shown in the Clarence

NOT BUSHFIRE PRONE

AT 3 CARPENTER CIRCLE, CLARENDON VALE

PROPOSED DWELLING FOR MISSION AUSTRALIA HOUSING 2003 BA 190819.dgn

26/08/19

Changes as described on Cover Sheet

REVISION DATE

DESCRIPTION

A

26 August 2019

Page 5: DEVELOPMENT APPLICATION - City of Clarence...Nov 27, 2019  · 2826to c/lofp ipe 4 0 0 m in im u m 400 minimum P R E L I M I N A R Y 2 6 1 5 3 9 9 9 stormwater shc SWMH p a l i n g

2400

2400

2400

2400

P R E

L I M I N A

R Y

A.J. A.J.

A.J.A.J.

A.J. A.J.

A.J. A.J.

CL

windows

aluminium

Powdercoat

windows

aluminium

Powdercoat

veneer

Brick

veneer

Brick

veneer

Brick

m/b

@ 22.5° pitch

Colorbond roof

@ 22.5° pitch

Colorbond roof

@ 22.5° pitch

Colorbond roof

@ 22.5° pitch

Colorbond roof

NGL

NGL

NGL

CL

FFL 48.20

FFL 48.20

NGL

CL

FFL 48.20

NGL NGLTitle boundary

PD4.1 template

CL

FFL 48.20

NORTH ELEVATION

SOUTH ELEVATION

WEST ELEVATIONEAST ELEVATION

03DWG No:

ELEVATIONS

DRAWN BY:

FILE NAME:

DATE:

DRAWING:

PC

Compliance No. CC102Y - James Collins

of Ronald Young & Co Builders Pty Ltd

be reproduced without the written consent

© This document is copyright and may not

...........................................................

DATE:

...........................................................

SIGNATURE:

requirements / approvals).

the client (with exception of Council

permitted after plans are signed by

PLEASE NOTE: no variations will be

...........................................................

THIS PLAN IS ACCEPTED BY:

Overlay

Interim Planning Scheme

As shown in the Clarence

NOT BUSHFIRE PRONE

AT 3 CARPENTER CIRCLE, CLARENDON VALE

PROPOSED DWELLING FOR MISSION AUSTRALIA HOUSING 2003 BA 190819.dgn

26/08/19

Changes as described on Cover Sheet

REVISION DATE

DESCRIPTION

A

26 August 2019