Hypothesis & GoalsHypothesis & Goals

Low levels of Aluminum in drinking water can be detected using a Photometric technique and GC-MS.

•Fluorescence Method

•GC-MS

Page 3: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

MethodologyMethodology

1. O-Phenanthroline (15mM) and Be2+ (0.1M)

2. Sodium Acetate Buffer Solution

3. Lumogallion

4. Heated

5. Triton

6. Measure Fluorescence

Page 4: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

ProblemProblem

Detecting 2x10-3 MNeeded to Detect 7.413x10-7 M

Page 5: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

Variables ChangedVariables Changed

Sodium Acetate Buffer

Time

Triton

Lumogallion

Temperature

Page 6: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

Neat vs. DilutedNeat vs. Diluted

Triton 1% v/v

TritonTriton

Triton

1% v/v

1% v/v

Page 7: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

Sodium Acetate BufferSodium Acetate Buffer

100uL pH=4.03

200uL pH=4.49

300uL pH=4.97

pH=4.49pH=4.97

pH=4.03

Page 8: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

TimeTime

30 minutes

45 minutes

60 minutes

60 min

45 min30 min

Page 9: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

TemperatureTemperature

25oC

4oC

25oC

4oC

Page 10: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

LumogallionLumogallion

100 uL = 2.85x10-6M

200 uL = 5.67x10-

6M 300 uL = 8.46x10-6M

5.67x10-6 M

8.46x10-6 M

2.85x10-6 M

Page 11: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

Optimum Conditions FoundOptimum Conditions Found

Excess lumogallionNeat Triton1 hourpH 54oC

Page 12: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

All Aluminum Chelated

Why Fluorescent Intensity ImprovesWhy Fluorescent Intensity Improves

More Viscous

Less Collisions

More time to form complex

Page 13: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

Testing 7.413x10Testing 7.413x10-7-7M SolutionM Solution

Different color Less Fluorescent Intensity

pH=4.96

pH=4.83

pH=4.77

Page 14: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

What About the Instrument?What About the Instrument?

Slit Width

– Excitation– Emission

Page 15: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

AccomplishedAccomplished

Found Optimum Conditions

Learned Instrument

Page 16: Detecting Aluminum in Drinking Water Erica Sandoval Dr. Henry Altmiller.

ConclusionConclusion

Test Drinking Water

Begin GC-MS Technique

Different Water Source