DETAIL PLAN 24 KESTREL STREET PRIMROSE SANDS€¦ · n dp-ad 45334 tas 400648168 qld 15127260...
Transcript of DETAIL PLAN 24 KESTREL STREET PRIMROSE SANDS€¦ · n dp-ad 45334 tas 400648168 qld 15127260...
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B1.1COVER SHEET 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
LOT 24 KESTREL STREET PRIMROSE SANDS
DRAWING INDEXDRAWING NAME SCALE
COVER SHEET
SHEET No.NTS1.1
GENERAL NOTES NTS1.2
EXCAVATION PLAN 1 : 2002.2
SITE PLAN2.3
RETAINING WALL PLAN2.4
PLAN - GROUND FLOOR3.1
ELEVATION 1 & 24.1
ELEVATION 3 & 44.2
ELEVATION 5 1 : 1004.3
ELECTRICAL PLAN5.1
SECTIONS7.1
SLAB & PLUMBING PLAN
8.1
8.2
WINDOW & DOOR SCHEDULE
GR
APH
ICA
L R
EPR
ESEN
TATI
ON
ON
LY
DEMOLITION PLAN 1 : 2002.1
1 : 200
1 : 200
1 : 100
1 : 100
1 : 100
1 : 50
1 : 50
1 : 100
1 : 100
6.1 1 : 100
STANDARD DETAILS - 19.1 AS SHOWN
ENSUITE & LAUNDRY PLAN
10.1 1 : 50
KITCHEN & ROBE PLAN
STANDARD DETAILS - 29.2 AS SHOWN
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B1.2GENERAL NOTES 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
-
RICHARD MASON,ONSITE ASSESSMENTS TAS
GENERAL NOTESDO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS ONLY.THE OWNER, BUILDER AND/OR SUB-CONTRACTORS SHALL VERIFY ALL DIMENSIONS,LEVELS, SETBACKS AND ANY SPECIFICATIONS PRIOR TO COMMENCING ANY WORKSOR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALLBUILDING WORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, AUSTRALIANSTANDARDS CODES (CURRENT EDITION), BUILDING REGULATIONS, LOCAL BY-LAWSAND RESCODE REQUIREMENTS. REPORT ALL DISCREPANCIES TO THIS OFFICE FORCLARIFICATION.
1. THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS AND DRAWINGS.
THESE PLANS SHALL BE READ IN CONJUNCTION WITH THE SOIL REPORT. FOOTINGS ARE TO FOUNDED AT THE MINIMUM DEPTHS INDICATED IN THE SOIL REPORT. WHERE THE BUILDING (OTHER THAN A CLASS 10a) IS LOCATED IN A DESIGNATED TERMITE INFESTATION AREA, THE BUILDING SHALL BE PROTECTED IN ACCORDANCE WITH THE RELEVANT AUSTRALIAN STANDARDS.
2. STORMWATER SHALL BE TAKEN TO THE LEGAL POINT OF DISCHARGE TO THE SATISFACTION OF THE RELEVANT AUTHORITY.
3. SEWER OR SEPTIC SYSTEMS SHALL BE IN ACCORDANCE WITH THE RELEVANT AUTHORITY REQUIREMENTS.
4. FOOTINGS ARE NOT TO ENCROACH OVER ANY TITLE BOUNDARIES AND/OR EASEMENT LINES.
5. FOR BUILDINGS IN CLOSE PROXIMITY TO THE SEA, ENSURE THAT ALL STEELWORK, BRICK CAVITY TIES, STEEL LINTELS, ETC. THAT ARE EMBEDDED OR FIXED TO MASONRY BE PROTECTED IN ACCORDANCE WITH A.S. 3700-2001 (TABLE 2.2), HOT DIP GALVANIZED, STAINLESS STEEL OR CADMIUM COATED.
6. BUILDING SETBACKS ARE FROM TITLE LINE (NOT FENCE LINE) REFER TITLE RE-ESTABLISHMENT PLAN FOR CORRECT OFF SETS IN RELATION TO FENCE LINES.
7. ALL WET AREAS ARE TO COMPLY WITH B.C.A. 3.8.1 OR A.S. 3740 - 2004. WALL FINISHES SHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVE FLOOR LEVEL TO ANY SHOWER ENCLOSURES AND 1500mm ABOVE BATHS, BASIN, SINKS AND THROUGHS IF WITHIN 75mm OF THE WALL.
8. RISERS - (where applicable) 190MM MAXIMUM, GOING - 355mm MAXIMUM, 240mm MIMIMUM. RISERS AND TREADS ARE TO BE CONSTANT IN SIZE THRU-OUT FLIGHT. PROVIDE NON-SLIP FINISH OR SUITABLE NON-SKID STRIP NEAR EDGE OF NOSINGS. ENSURE MAXIMUM GAP BETWEEN RISERS IS NOT TO EXCEED 125mm OR USE CLOSED RISERS. PROVIDE CONTINUOUS HAND RAILING 1000mm MINIMUM HEIGHT TO BALCONIES AND DECKS WHICH ARE 1000mm OR GREATER ABOVE GROUND LEVEL. HAND RAILS ARE TO BE A MINIMUM OF 865MM ABOVE STAIR NOSINGS AND LANDINGS. MAXIMUM GAP BETWEEN BALUSTERS SHALL BE 125mm.
9. SMOKE ALARMS ARE TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH A.S. 3786-1993, AND UNLESS INSTALLED IN AN EXISTING PART OF A CLASS 1, 2 OR 3 BUILDING OR A CLASS 4 PART OF A BUILDING. THE SMOKE ALARM SHALL BE HARD-WIRED WITH A BATTERY BACK-UP INTERCONNECTED.
WALL LINTELS & SUPPORT STUDS THRU-OUT:FOR ALL EXTERNAL PERIMETER LOAD-BEARING LINTELS AND THEIRSUPPORTING STUDS REFER TO THE ENGINEERS DETAILS AND DRAWINGSAND TO GENERAL SPECIFICATIONS.
INTERNAL DOORS:ALL INTERNAL DOORS ARE TO BE 2040 HIGH UNLESS NOTED OTHERWISEON THE PLAN.
WC DOORS:HINGED DOORS THAT OPEN INWARDS TOWARDS THE PAN BUT THE EDGE OFTHE DOOR IS A MINIMUM 1200mm AWAY FROM THE PAN AT ITS NEAREST POINT,MUST HAVE DEMOUNTABLE HINGES TO ALLOW EASY REMOVAL OF THE DOORFROM THE OUTSIDE THE WC COMPARTMENT.
ROOFINGMETAL ROOF OVER ROOF BATTENS AT 330mm CTRS. TYPICAL THRU-OUTUNLESS NOTED OTHERWISE. METAL ROOF ON EITHER TIMBER OR METALBATTENS TO BE USED AND FIXED IN ACCORDANCE WITH THE MANUFACTURERSDETAILS AND SPECIFICATIONS & PROVIDE APPROVED CAPPING AND FLASHINGTHRU-OUT.
SELECTED TIMBER FRAMED ROOF TRUSS AT 900mm MAX. CTRS. TOMANUFACTURERS SPECIFICATIONS UNLESS NOTED OTHERWISE.
PLASTERBOARD LINED CEILINGS THRU-OUT.
SELECTED PROFILE METAL EAVES GUTTER AND FASCIA TO THE PERIMETEROF THE ROOF AREA.
ALSO READ IN CONJUNCTION WITH ANY ENGINEERS DETAILS AND DRAWINGSFOR ANY ROOF BEAMS, LINTELS, ETC.
4.5mm THICK F.C. SHEET LINING TO THE UNDERSIDE OF THE FIRST
LINTEL NOTES:BUILDER TO NOTE THAT LINTELS SELECTED BY THE ENGINEER ARE DESIGNEDTO CARRY ONLY STANDARD TILE ROOFING AND TRUSS LOADS WHERE AREAT 600MM MAXIMUM CTRS. IF ANY GIRDER TRUSSES ARE LOCATED DIRECTLYON ANY LINTELS.
TRUSS MANUFACTURER AND/OR BUILDER TO REFER TO THE ENGINEER TOCONFIRM IF LINTEL AND SUPPORTING STUDS ARE ADEQUATE.
ENGINEER'S DRAWINGS TAKE PRECEDENCE OVER NOMINAL SIZES INDICATEDON THESE PLANS.
FRAMING SCHEDULEN/A
SOIL CLASSIFICATIONrefer to soil report attached
BY :
DATE :
B.A.L. :
26/07/2019
BAL 29
WALL FRAME(REFER TO ENGINEERING DRAWINGS)
EXTERNAL STUDS
INTERNAL STUDS
N/A
450mm ctrs U.N.O.BAL 29 GLAZING:FOR WINDOWS:COMPLY WITH ONE OF THE FOLLOWING OPTIONS:
OPTION 1: STANDARD WINDOWS CAN BE USED PROVIDED THEY ARE COMPLETELYPROTECTED BY BUSHFIRE SHUTTERS COMPLYING WITH AS 3959:2009.
OPTION 2: WINDOWS MUST MEET THE FOLLOWING:
1. ALL GLAZING SHALL BE TOUGHENED SAFETY GLASS MINIMUM 5mm.2. WINDOW FRAMES SHALL BE MADE FROM ONE OF THE FOLLOWING: A. BUSHFIRE RESISTANT TIMBER - SEE p.16 B. METAL - THIS INCLUDES ALUMINIUM C. uPVC WITH METAL REINFORCING3. EXPOSED EXTERNAL HARDWARE THAT SUPPORT THE SASH IN ITS FUNCTION OF OPENING AND CLOSING TO BE MADE FROM METAL.4. ALL GLASS WITHIN 40mm OF GROUND OR OTHER STRUCTURES WITHIN 18 DEGREES OF HORIZONTAL (REFER 4 DIAGRAM pp. 12-13) MUST BE SCREENED EXTERNALLY WITH METAL SCREENS WITH MAXIMUM APERTURE OF 2mm (STEEL, BRONZE OR ALUMINIUM).5. ALL OPENINGS MUST BE SCREENED INTERNALLY OR EXTERNALLY WITH METAL SCREENS WITH MAXIMUM APERTURE OF 2mm (STEEL, BRONZE OR ALUMINIUM).
NOTE: INTERNAL AND EXTERNAL SCREENS MUST BE FITTED IN A WAY THAT DOES NOTALLOW GAPS GREATER THAN 3mm IN DIAMETER. WHERE IGU's ARE USED AND 5mmTOUGHENED GLASS IS REQUIRED IT ONLY NEEDS TO BE APPLIED TO THE EXTERNAL FACE
FOR SIDE HUNG EXTERNAL DOORS INCLUDING FRENCH AND BI-FOLD DOORS:OPTION 1: AS PER WINDOWS.OPTION 2: ARE COMPLETELY PROTECTED BY EXTERNAL METAL MESH SCREENS WITH AMAXIMUM APERTURE OF 2mm (STEEL, BRONZE OR ALUMINIUM)OPTION 3: 1. DOORS SHALL BE: A. NON COMBUSTIBLE OR B. 35mm SOLID TIMBER FOR THE FIRST 400mm ABOVE THRESHOLD OR C. HOLLOW CORE DOORS MUST BE PROTECTED EXTERNALLY WITH METAL SCREENS WITH MAXIMUM APERTURE OF 2mm (STEEL, BRONZE ALUMINIUM). D. A FULLY FRAMED GLAZED DOOR MADE FROM NON COMBUSTIBLE MATERIALS OR BUSHFIRERESISTANT TIMBER (p. 16) 2. EXPOSED EXTERNAL HARDWARE MUST BE METAL. 3. ALL GLAZING SHALL BE TOUGHENED SAFETY GLASS MINIMUM OF 6mm. 4. ALL GLASS WITHIN 400mm OF GROUND OR OTHER STRUCTURES WITHIN 18 DEGREES OF HORIZONTAL (REFER 4 DIAGRAMS pp. 12-13) MUST BE SCREENED EXTERNALLY WITH METAL SCREENS WITH MAXIMUM APERTURE OF 2mm (STEEL, BRONZE OR ALUMINIUM). A GUIDE TO WINDOWS AND DOORS IN BUSHFIRE PRONE AREAS 5. DOOR FRAMES SHALL BE MADE OF A. BUSHFIRE RESISTING TIMBER (SEE page 16) B. METAL C. METAL-REINFORCED uPVC 6. DOORS SHALL BE TIGHT FITTING. 7. WEATHER STRIPS, DRAUGHT SEALS SHALL BE INSTALLED AT BASE OF SIDE HUNG EXTERNAL DOORS.FOR EXTERNAL SLIDING DOORS:OPTION 1: AS PER WINDOWS.OPTION 2: ARE COMPLETELY PROTECTED BY EXTERNAL METAL SCREENS WITH A MAXIMUM APERTURE OF 2mm (STEEL, BRONZE OR ALUMINIUM)OPTION 3: 1. FRAMES SHALL BE MADE OF: 2. EXPOSED EXTERNAL HARDWARE MUST BE METAL. 3. ALL GLAZING SHALL BE TOUGHENED SAFETY GLASS MINIMUM 6mm. 4. SLIDING DOORS SHALL BE TIGHT FITTING IN THE FRAME. THE CONSTRUCTION OF SLIDING DOORS SHOULD PREVENT THE ENTRY OF MEMBERS WHEN CLOSED.
NOTE: SLIDING DOORS ARE NOT REQUIRED TO BE SCREENED.
SPECIFICATION NOTES:TIMBER FRAMING:ALL TIMBER FRAMING THRU-OUT IS TO BE IN ACCORDANCE WITH A.S.1684.2-2010 AND ALSO READ IN CONJUNCTION WITH THE ENGINEERS DETAILSAND DRAWINGS.
FLOORING & FOOTINGS:FINISHED FLOOR LEVELS ARE NOMINAL ONLY AND SHOULD BE CONFIRMEDPRIOR TO START OF WORK.
READ IN ACCORDANCE WITH SOIL REPORT REQUIREMENTS. READ INCONJUNCTION WITH THE ENGINEERS DETAILS FOR ALL FOOTING SIZE ANDDETAILS.
PLEASE NOTE MINIMUM FOUNDING DEPTH TO BE DETERMINED AS 'NOTED"IN THE SOIL REPORT.
WALLING:90 x 35 MGP10 COMMON STUDS70 x 35 F5 NOGGINGS2 (90 x 35) MGP10 TOP PLATES EXTERNAL WALL2 (90 x 45) MGP12 TOP PLATES - INTERNAL LOAD BEARING WALLS2 (90 x 45) MGP10 JAMB STUDS3 (90 x 45) MGP10 JAMB STUDS TO ALL GIRDER TRUSS LOAD LOCATION
LININGS:10mm PLASTERBOARD TO ALL INTERNAL WALLS10mm PLASTERBOARDS TO CEILINGSSELECTED WATER RESISTANT SUB-STRATE AND TILING TO WET AREAS.
HEATING AND COOLING:ALL HEATING AND COOLING UNITS, SIZES, TYPES AND LOCATIONS ARETO BE CONFIRMED BETWEEN THE BUILDER AND THE SUPPLIER.
ALL HEATING AND COOLING DUCTS AND VENT LOCATIONS ARE TO BECONFIRMED BY THE BUILDER PRIOR TO COMMENCEMENT OF BUILDINGTO DETERMINE IF ANY ADDITIONAL RISER DUCTS ARE REQUIRED.
ALL HEATING AND COOLING POINTS LOCATIONS, MAY VARY FROM PLANTO PLAN.
GEOTECHNICAL:THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH A GEOTECHNICALREPORT. IT IS THE BUILDER'S RESPONSIBILITY TO OBTAIN SUCH REPORTSPRIOR TO COMMENCEMENT OF WORKS.
FULL HEIGHT CONTROL JOINTS (FOOTING TO EAVES) AT 5m MAX. CTRS UNLESSNOTED OTHERWISE - REFER TO ARTICULATION JOINT PLAN.
REFER TO SOIL REPORT.
WATERPROOFING:AS370 - WATERPROOFING MEMBRANES, SUBSTRATA ANDSTRUCTURAL DETAILS FOR THE WATERPROOFING OF DOMESTICBUILDING CLASS 1A MUST BE IN ACCORDANCE WITH AS3740.REFER TO DETAILS WITHIN THE PLAN SET.
TERMITE MANAGEMENT:WHERE APPLICABLE AN APPLIED TERMITE MANAGEMENT SYSTEM,BOTH PART A 7 PART B MUST BE IN ACCORDANCE WITH AUSTRALIANSTANDARD 3660.1-2014TERMITE MANAGEMENT - NEW BUILDINGWORK AS PER THE BCA CLAUSE 31.3
BRACING SCHEDULEREFER TO ENGINEERING DRAWINGS
ENERGY REPORT
FLOOR: CONCRETE SLAB 50mm XPS = R2.7
INSULATION TO BE INSTALLED TO THE FOLLOWING AREAS :
6 STAR NOTE:
PVC WINDOWS & SLIDING DOORS DOUBLE GLAZEDU-value = 2.09 / SHGC = 0.42.
65/50/150 THERMACELL HAVE R1.7, THERMAL MASSCOMPENSATES FOR LOW R RATING (STORES HEAT/COOLNESS).
NOTE ROOF HAS ANTICON ROOF BLANKETR1.4 + R4 CEILING BATTS
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REF No. # SXR962 - 18/09/2019
WINDOWS:ALL GLAZINGSHALL CONFORM TO AS 1288-2006. WINDOW SIZES SHOWN ARE NOMINAL DEPENDINGON THE WINDOW MANUFACTURERS CLOSEST STANDARD SPECIFICATIONS.
1. ALL GLAZING IS TO BE IN ACCORDANCE WITH AS1228-2006.2. READ IN CONJUNCTION WITH THE WINDOW SCHEDULE AND ELEVATIONS.3. ALL EXTERNAL DOORS ARE TO FITTED WITH WEATHER STRIPS.4. REFER TO WINDOW SCHEDULE FOR OPENING STYLES.5. ALL WINDOWS TO BE DOUBLE GLAZED.
NOTE: THESE HEIGHTS MAY VARY SLIGHTLY ACCORDING TO DIFFERENCES IN CONCRETE PANEL SIZES.
EXTERNAL WALLS: THERMACELL POLYSTYRENEEXTRUDED = R1.7
CONSTRUCTION INSULATION TYPE
INTERNAL WALLS: TIMBER STUD NO INSULATION
ROOF: METALCEILING: PLASTERBOARD
FIBREGLASS ORROCKWOOL BATTS= R4.0 + 1.4
B
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B2.1DEMOLITION PLAN 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
NOTE:1. Level Datum is AHD per RTK GPS.2. Only that detail apparent on site at the time of survey
has been located by this plan. Other features andservices may exist on, under or over the site.
3. Contour interval is 0.25 metres.
32.60 m
22.0
0 m
10.89 m
42.71 m
5.00 m
7.00
m
KESTRELSTREET
C.T.7649/111
track
Paling Fence
EucalyptDBH1200
EucalyptDBH900EucalyptDBH1200
overhead power
Power Pole
Picket
Picket
Picket
Star
Star
Peg
No Mark
drain
Brick HouseNo.11 Kestrel St
VacantNo.22 Kestrel St
Palin
g Fe
nce
Ref Peg57.86
Pty Ltd
DETAIL PLAN24 KESTREL STREETPRIMROSE SANDS
DRAWING No.
DATE
SCALE
DRAWN
19169-02
NMC
CLIENT Terhorst
62 Channel Highway Ph. 62296563Kingston 7050 Mobile: 0427 879 023Email: [email protected]
Web: www.larkandcreese.com.auLand & Engineering SurveyorsLARK & CREESE
05/06/19
1:150
NOTE:TREES TO BE REMOVED BY OWNER
SHOWN HATCHED
62.0
0
62.2
5
62.5
0
62.7
5
63.0
0
61.0
0
60.0
0
59.0
0
58.0
0
58.2
5
58.5
0
58.7
5
59.2
5
59.5
0
59.7
560.2
5
60.5
0
60.7
561.2
5
61.5
0
61.7
5
EXISTING TREES TO BEREMOVED BY OWNER
DEMOLITION PLAN
NOTE : AUTHORITY APPROVALSITING OF PROPOSED RESIDENCE ISSUBJECT TO APPROVAL BY DEVELOPERAND RELEVANT LOCAL AUTHORITY.
NOTE : DRIVEWAY GRADIENTDRIVEWAY TO BE GRADED TO ENSUREMAXIMUM 1:6 GRADIENT FROM CROSSOVERTO GARAGE FLOOR
NOTE : TERMITE PROTECTION(AT GARAGE)PROVIDE TERMITE TREATMENT INACCORDANCE WITH AS 3660.1
NOTE : DRAINAGE REQUIREMENTSTREATMENT OF WASTEWATER PRIOR TO LANDDISPOSAL/ABSORPTION IS PREFERRED.
TO INSTALL A SEPTIC TANK DISCHARGING TOAN ADVANCED ENVIRO SEPTIC (AES) BED.
UPSLOPE CUT-OFF DRAINAGE IS REQUIRED;GIVEN PROXIMITY TO THE UPSLOPE BUILDING.
NOTE : BOUNDARY PEGS1. TO BE LOCATED PRIOR TO COMMENCEMENT OF WORKS.
NOTE : DOWNPIPESREFER TO RAINWATER HARVESTING
NOTE : BOUNDARY WALLSN/A
NOTE: DWELLING IS TO BE CONNECTED TORECYCLED WATER AND PLUMBED INACCORDANCE WITH SORELL COUNCILREQUIREMENTS AND RECOMMENDATIONSINCLUDING A FRONT AND REAR RECYCLEDWATER TAP AND CONNECTION TO ALLTOILETS AS MINIMUM.
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B2.2EXCAVATION PLAN 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
NOTE:1. Level Datum is AHD per RTK GPS.2. Only that detail apparent on site at the time of survey
has been located by this plan. Other features andservices may exist on, under or over the site.
3. Contour interval is 0.25 metres.
32.60 m
22.0
0 m
10.89 m
42.71 m
5.00 m
7.00
m
KESTRELSTREET
C.T.7649/111
Paling Fence
EucalyptDBH1200
overhead power
Power Pole
Picket
Picket
Picket
Star
Star
Peg
No Mark
drain
Brick HouseNo.11 Kestrel St
VacantNo.22 Kestrel St
Palin
g Fe
nce
Ref Peg57.86
Pty Ltd
DETAIL PLAN24 KESTREL STREETPRIMROSE SANDS
DRAWING No.
DATE
SCALE
DRAWN
19169-02
NMC
CLIENT Terhorst
62 Channel Highway Ph. 62296563Kingston 7050 Mobile: 0427 879 023Email: [email protected]
Web: www.larkandcreese.com.auLand & Engineering SurveyorsLARK & CREESE
05/06/19
1:150
62.0
0
62.2
5
62.5
0
62.7
5
63.0
0
61.0
0
60.0
0
59.0
0
58.0
0
58.2
5
58.5
0
58.7
5
59.2
5
59.5
0
59.7
560.2
5
60.5
0
60.7
561.2
5
61.5
0
61.7
5
14,030
1,000 970
26513,500
265
17,466
16,44
5
10,018
11,354
14,405
14,631
12,092
11,334
6,000
765
3,70
094
3
1,213
943
889
5,53
065
082
0
265
5,00
026
5
6,01
4
16,000
7,00
0
GARAGEF.F.L. AT R.L. 62.30
SAND PADAT R.L. 62.40
R.L. 60.15
R.L. 60.35
R.L. 62.36
VERANDAHR.L. 60.55
R.L. 60.15
HOUSE OVERALL
EXTENT OF SAND PADEXTENT OF SAND PAD
CONCRETE SLAB
EXTE
NT
OF
SAN
D P
ADEX
TEN
T O
F SA
ND
PAD
HO
US
E O
VE
RA
LL
CO
NC
RE
TE S
LAB
SAND PAD OUTLINE
CONCRETE SLAB OUTLINE
HOUSE OUTLINE
BUILDING PLATFORM = R.L. 60.61 mSAND PAD = R.L. 60.15 m
EXTENT OF CUT
EXCAVATION VOLUME : 1.92 m³FILL VOLUME : 7.21 m³NET : 5.30 m³ BORROW
DECK OUTLINE
SAND PAD
SAN
D P
AD
EXCAVATION VOLUME : 1.92 m³FILL VOLUME : 7.21 m³NET : 5.30 m³ BORROW
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
NOTE : AUTHORITY APPROVALSITING OF PROPOSED RESIDENCE ISSUBJECT TO APPROVAL BY DEVELOPERAND RELEVANT LOCAL AUTHORITY.
NOTE : DRIVEWAY GRADIENTDRIVEWAY TO BE GRADED TO ENSUREMAXIMUM 1:6 GRADIENT FROM CROSSOVERTO GARAGE FLOOR
NOTE : TERMITE PROTECTION(AT GARAGE)PROVIDE TERMITE TREATMENT INACCORDANCE WITH AS 3660.1
NOTE : DRAINAGE REQUIREMENTSTREATMENT OF WASTEWATER PRIOR TO LANDDISPOSAL/ABSORPTION IS PREFERRED.
TO INSTALL A SEPTIC TANK DISCHARGING TOAN ADVANCED ENVIRO SEPTIC (AES) BED.
UPSLOPE CUT-OFF DRAINAGE IS REQUIRED;GIVEN PROXIMITY TO THE UPSLOPE BUILDING.
NOTE : BOUNDARY PEGS1. TO BE LOCATED PRIOR TO COMMENCEMENT OF WORKS.
NOTE : DOWNPIPESREFER TO RAINWATER HARVESTING
NOTE : BOUNDARY WALLSN/A
NOTE: DWELLING IS TO BE CONNECTED TORECYCLED WATER AND PLUMBED INACCORDANCE WITH SORELL COUNCILREQUIREMENTS AND RECOMMENDATIONSINCLUDING A FRONT AND REAR RECYCLEDWATER TAP AND CONNECTION TO ALLTOILETS AS MINIMUM.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B2.3SITE PLAN 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
NOTE:1. Level Datum is AHD per RTK GPS.2. Only that detail apparent on site at the time of survey
has been located by this plan. Other features andservices may exist on, under or over the site.
3. Contour interval is 0.25 metres.
32.60 m
22.0
0 m
10.89 m
42.71 m
5.00 m
7.00
m
KESTRELSTREET
C.T.7649/111
Paling Fence
EucalyptDBH1200
overhead power
Power Pole
Picket
Picket
Picket
Star
Star
Peg
No Mark
drain
Brick HouseNo.11 Kestrel St
VacantNo.22 Kestrel St
Palin
g Fe
nce
Ref Peg57.86
Pty Ltd
DETAIL PLAN24 KESTREL STREETPRIMROSE SANDS
DRAWING No.
DATE
SCALE
DRAWN
19169-02
NMC
CLIENT Terhorst
62 Channel Highway Ph. 62296563Kingston 7050 Mobile: 0427 879 023Email: [email protected]
Web: www.larkandcreese.com.auLand & Engineering SurveyorsLARK & CREESE
05/06/19
1:150
PROPOSED RESIDENCEF.F.L. 0.00 (R.L. 60.61)SAND PAD R.L. 60.15
GARAGECONCRETE SLAB
(R.L. 62.40)
BAL-40
BAL-29
3.0 m WIDE DRIVEWAYCOMPACTED FCR WITH
GRAVEL OVERLAY
SETBACK
SETBACK
SETBACK
SETB
ACK
SETBACK
SETBACK
SETOUTPOINT
SETOUTPOINT
SETOUT
SETOUT
SETOUT
SETOUT
SETO
UT
SETO
UT SETOUT POINT
LOT AREA : 763.14 m²
EXTENT OF SAND PAD
EXTE
NT
OF
SAN
D P
AD
BAL-29
BAL-40
CROSSOVER TO COUNCILREQUIREMENTSCROSSOVER WITH HARDSTANDTO COMPLY WITH PART 4.3,THE DETERMINATION
BLOCKPAVED STEPS350W x 180H
1000 HIGH STAINLESS STEELWIRE BALUSTRADE
62.0
0
62.2
5
62.5
0
62.7
5
63.0
0
61.0
0
60.0
0
59.0
0
58.0
0
58.2
5
58.5
0
58.7
5
59.2
5
59.5
0
59.7
560.2
5
60.5
0
60.7
561.2
5
61.5
0
61.7
5
AES BED 5.60m x1.80m
GALVANISED STEELFRAMED CONSTRUCTIONTO VERANDAH
3250L SEPTIC TANK
ELECTRICALPRELAY
NOTE:BATTER SLOPES WILL BE INITIALLYSTABILISED USING GEOTEXTILEPLANTED WITH NATIVE GRASSES.
NOTE:BUSHFIRE ATTACK LEVEL TO BE BAL-29REFER TO CONSULTANT DRAWINGS BUSHFIRE HAZARD MANAGEMENT PLAN.BUILDING WORKS TO COMPLY WITH BAL-29,AS 3959-2019.
SETOUTPOINT
NOTE:WASTE WATER TREATMENT
SYSTEM IN PIPE LAYS(DOWNPIPE LINE TO BE "CHARGED LINEFULLY SEALED THROUGH GRAVITY PRESSURE)
22,470 LITRE TANK3.40m DIAMETER x 2.475 HIGH
DUALPURPOSE
TANK
OVERHEAD PRIVATEPOWER POLE CONNECTEDTO UNDERGROUNDSERVICE POWER RUN
DP
DP DP
3,789
9,588
7,033
5,48
8
4,811
11,230
14,922
15,025
1,533
15,093
14,356
3,150
12,7
67
5,89
4
3,33
8
8,26
7 SE
TOU
T
12,674 SETOUT
14,127 SETOUT
5,11
6 SE
TOU
T
10,1
97 S
ETO
UT
9,536 SETOUT
7,497 SETOUT
11,3
11 S
ETO
UT
5,47
5 SE
TOUT
1,52
5
938
888
15,081
3,00
0
1,500
2,000
10,300 (NOM.)
6,01
4
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT
ALUMINIUM FRAME
VERANDAHF.F.L. -0.060 (R.L. 60.55)
SETB
ACK
SETOUT POINT
EXTE
NT
OF
SAN
D P
AD
R.L.60.35
R.L. 62.36
EXISTING
RAMP UP PATH
RAINWATER TANK PUMPELECTRICAL BOX
ELEC. M/BOX
TAP
TAP
TAP
EXT. AIRCON
RESERVED AREAFOR AES
ELECTRIC HWS& HEAT PUMP
SOLARINVERTER
BOX
R.L. 60.15
R.L. 60.15
±0 ±0
±0±0
1 : 200
TOTAL HOUSE AREATOTAL HOUSE AREA 99.19 m²SITE AREA 763.14 m²SITE COVERAGE 13.00 %
FOOT PATH 93.05 m²
PERMEABLE COVERAGE 55.08 %IMPERMEABLECOVERAGE (HARD SURFACEAT FRONT)
12.14 %
OPEN SPACE 87.00 %
PAVING CALCULATION
DRIVEWAY 92.63 m²CROSSOVER 22.35 m²
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
NOTE : AUTHORITY APPROVALSITING OF PROPOSED RESIDENCE ISSUBJECT TO APPROVAL BY DEVELOPERAND RELEVANT LOCAL AUTHORITY.
NOTE : DRIVEWAY GRADIENTDRIVEWAY TO BE GRADED TO ENSUREMAXIMUM 1:6 GRADIENT FROM CROSSOVERTO GARAGE FLOOR
NOTE : TERMITE PROTECTION(AT GARAGE)PROVIDE TERMITE TREATMENT INACCORDANCE WITH AS 3660.1
NOTE : DRAINAGE REQUIREMENTSTREATMENT OF WASTEWATER PRIOR TO LANDDISPOSAL/ABSORPTION IS PREFERRED.
TO INSTALL A SEPTIC TANK DISCHARGING TOAN ADVANCED ENVIRO SEPTIC (AES) BED.
UPSLOPE CUT-OFF DRAINAGE IS REQUIRED;GIVEN PROXIMITY TO THE UPSLOPE BUILDING.
NOTE : BOUNDARY PEGS1. TO BE LOCATED PRIOR TO COMMENCEMENT OF WORKS.
NOTE : DOWNPIPESREFER TO RAINWATER HARVESTING
NOTE : BOUNDARY WALLSN/A
NOTE: DWELLING IS TO BE CONNECTED TORECYCLED WATER AND PLUMBED INACCORDANCE WITH SORELL COUNCILREQUIREMENTS AND RECOMMENDATIONSINCLUDING A FRONT AND REAR RECYCLEDWATER TAP AND CONNECTION TO ALLTOILETS AS MINIMUM.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B2.4RETAINING WALL PLAN 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
NOTE:1. Level Datum is AHD per RTK GPS.2. Only that detail apparent on site at the time of survey
has been located by this plan. Other features andservices may exist on, under or over the site.
3. Contour interval is 0.25 metres.
32.60 m
22.0
0 m
10.89 m
42.71 m
5.00 m
7.00
m
KESTRELSTREET
C.T.7649/111
Paling Fence
EucalyptDBH1200
overhead power
Power Pole
Picket
Picket
Picket
Star
Star
Peg
No Mark
drain
Brick HouseNo.11 Kestrel St
VacantNo.22 Kestrel St
Palin
g Fe
nce
Ref Peg57.86
Pty Ltd
DETAIL PLAN24 KESTREL STREETPRIMROSE SANDS
DRAWING No.
DATE
SCALE
DRAWN
19169-02
NMC
CLIENT Terhorst
62 Channel Highway Ph. 62296563Kingston 7050 Mobile: 0427 879 023Email: [email protected]
Web: www.larkandcreese.com.auLand & Engineering SurveyorsLARK & CREESE
05/06/19
1:150
PROPOSED RESIDENCEF.F.L. 0.00 (R.L. 60.61)SAND PAD R.L. 60.15
GARAGECONCRETE SLAB
(R.L. 62.40)
BAL-40
BAL-29
3.0 m WIDE DRIVEWAYCOMPACTED FCR WITH
GRAVEL OVERLAY
EXTENT OF SAND PAD
EXTE
NT
OF
SAN
D P
AD
BAL-29
BAL-40
CROSSOVER TO COUNCILREQUIREMENTSCROSSOVER WITH HARDSTANDTO COMPLY WITH PART 4.3,THE DETERMINATION
BLOCKPAVED STEPS350W x 180H
1000 HIGH STAINLESS STEELWIRE BALUSTRADE
62.0
0
62.2
5
62.5
0
62.7
5
63.0
0
61.0
0
60.0
0
59.0
0
58.0
0
58.2
5
58.5
0
58.7
5
59.2
5
59.5
0
59.7
560.2
5
60.5
0
60.7
561.2
5
61.5
0
61.7
5
GALVANISED STEELFRAMED CONSTRUCTIONTO VERANDAH
ELECTRICALPRELAY
NOTE:BATTER SLOPES WILL BE INITIALLYSTABILISED USING GEOTEXTILEPLANTED WITH NATIVE GRASSES.
NOTE:BUSHFIRE ATTACK LEVEL TO BE BAL-29REFER TO CONSULTANT DRAWINGS BUSHFIRE HAZARD MANAGEMENT PLAN.BUILDING WORKS TO COMPLY WITH BAL-29,AS 3959-2019.
22,470 LITRE TANK3.40m DIAMETER x 2.475 HIGH
DUALPURPOSE
TANK
OVERHEAD PRIVATEPOWER POLE CONNECTEDTO UNDERGROUNDSERVICE POWER RUN
DP
DP DP
502
3,928
3,70
093
6
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT
ALUMINIUM FRAME
VERANDAHF.F.L. -0.060 (R.L. 60.55)
SETOUT POINT
EXTE
NT
OF
SAN
D P
AD
R.L.60.35
R.L. 62.36
EXISTING
RAMP UP PATH
RETAINING WALLT.O.W = R.L. 63.00
RETAINING WALLT.O.W = R.L. 62.70
RETAINING WALLT.O.W = R.L. 63.00
RAINWATER TANK PUMPELECTRICAL BOX
ELEC. M/BOX
TAP
TAP
TAP
EXT. AIRCON
RESERVED AREAFOR AES
ELECTRIC HWS& HEAT PUMP
SOLARINVERTER
BOX
R.L. 60.15
R.L. 60.15
NOTE : SITE SCRAPESCRAPE SITE TO REMOVE SURFACEVEGETATION AND PROVIDE LEVEL BUILDINGPLATFORM. PROVIDE ADDITIONAL CUT TOGARAGE AREA TO ACCOMODATE 86mmSLAB STEP DOWN.
NOTE : AUTHORITY APPROVALSITING OF PROPOSED RESIDENCE ISSUBJECT TO APPROVAL BY DEVELOPERAND RELEVANT LOCAL AUTHORITY.
NOTE : BACK FILLSITE TO BE BACK FILLED TO REBATEHEIGHT AND FALL AWAY FROM DWELLING.
NOTE : DRIVEWAY GRADIENTDRIVEWAY TO BE GRADED TO ENSUREMAXIMUM 1:6 GRADIENT FROM CROSSOVERTO GARAGE FLOOR
NOTE : TERMITE PROTECTIONPROVIDE TERMITE TREATMENT INACCORDANCE WITH AS 3660.1
NOTE : DRAINAGE REQUIREMENTS1. SITE PLUMBING AND DRAINAGE SHALL COMPLY WITH AS 2870-2011 RESIDENTIAL SLABS AND FOOTINGS, NCC312 DRAINAGE AND AS3500 NATIONAL PLUMBING AND DRAINAGE CODE.2. SURFACE WILL BE GRADED AWAY FROM FOOTING (MINIMUM FALL 1:20)3. TEMPORARY DOWNPIPES CONNECTED TO THE THE STORMWATER SYSTEM TO BE INSTALLED UPON COMPLETION OF THE ROOF COVER.4. BASE OF CUT GRADED TO SILT TRAP(S) PROTECTED BY GRAVEL FILTERS AND/OR SPOON DRAINS AS REQUIRED TO REMOVE SURFACE WATER AWAY FROM FOOTINGS AND TO PREVENT ON SITE PONDING.5. DESIGN OF SITE AND STORMWATER DRAINAGE IS AT THE DISCRETION OF THE DRAINAGE CONTRACTOR.6. SEWER PIPE AND DRAINAGE PIPE DIMENSIONS AND OFFSETS HAVE BEEN COPIED FROM RELEVANT AUTHORITIES OF THESE ASSETS. ALL MEASUREMENTS SHOWN ARE APPROXIMATE.
NOTE : BOUNDARY PEGS1. TO BE LOCATED PRIOR TO COMMENCEMENT OF WORKS.
NOTE : DOWNPIPES1. TO BE LOCATED PRIOR TO COMMENCEMENT OF WORKS.
NOTE : BOUNDARY WALLS1. WALL ON BOUNDARY CALCULATION: MAX. ALLOWABLE TO BE BUILT IS 10m + 25% OF REMAINING LENGTH OF BOUNDARY.
NOTE: DWELLING IS TO BE CONNECTED TORECYCLED WATER AND PLUMBED INACCORDANCE WITH WESTERN WATERRECOMMENTATIONS INCLUDING A FRONT ANDREAR RECYCLED WATER TAP ANDCONNECTION TO ALL TOILETS AS MINIMUM.
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B3.1FLOOR PLAN 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
DW
2100x1500 A2100x1500 A
720
820 CSD820 CSD
820
CS
D
2400x4000 SD
2400
x240
0 S
GD
800x
600
A
900x1200 A
REM
OTE
CO
NTR
OL
SEC
TIO
NAL
DO
OR
REFWMDry
BED 1BED 2
ENS
STUDYL'DRY
LIVING
DINING
KIT
CH
EN
VERANDAH
VERANDAH
C L
CL
A7.1
A7.1
DPB7.1
B7.1
C7.1
C7.1
DP DP
FW
14,030 OVERALL
265 157,312
166,142
15 265
2652,510 ENS
902,810 L'DRY
901,790 STUDY
906,120 KITCHEN/DINING/LIVING
2653,000 VERANDAH
6,075 1,200 W 5,435470
850
265
5,00
026
5
465
600
W4,
465
265
1,89
0 E
NS
903,
020
BE
D 2
265
6,01
4
265
800
L'D
RY 90
1,00
0 PA
SS90
1,22
01,
800
RO
BE
265
265
1,89
0 S
TUD
Y90
3,02
0 B
ED
126
5
14,030 OVERALL265 15 7,060 P2 PANEL
156,395 P1 PANEL
15 265
1,015 1,500 W 2,210 1,500 W 2,940 4,000 S/DOOR 865
2653,600 BED 2
903,600 BED 1
906,120 KITCHEN/DINING/LIVING
265
630
2,44
063
0
3,000
3,000
5,53
0 P6
PAN
EL2,
000
7,53
0 O
VER
ALL
400400
850 1,500 850850 1,500 850
3,000 VERANDAH
6,000 GARAGE O/ALL
751,
738
751,
738
75
3,70
0 O
VER
ALL
1,85
01,
850
9,600 VERANDAH
ROBE
RA
KIN
G C
EIL
ING
CONCRETE SLABF.F.L. 0.00 (R.L. 60.61)
OVERHEADCUPB'DS
ELEC HPUBOCHARCOALFILTEREXTRACTOR
RA
KIN
G C
EIL
ING
RA
KIN
G C
EIL
ING
RA
KIN
GC
EIL
ING
2810Wx 2100H OPENING
BORED ERECTION PADTO ENGINEER'S SPECIFICATION
89 x 89mm SHS POST SUPPORTON 450Ø CONCRETE COLUMNTO ENGINEER'S SPECIFICATION
1000 HIGH STAINLESS STEEL WIREBALUSTRADE TO NCC REQUIREMENTS
NOTE :PRECAST CONCRETE SANDWICHPANEL TO EXTERNAL WALL WITH
50mm XPS GRADE INSULATION
NOTE :RAKING CEILING THROUGHOUT
1:10
0 FA
LL
450 WIDE RAKE EAVES (LINED)
450
WID
E EA
VES
(UNCOVERED)F.F.L. -0.060(R.L. 60.55)
P4
P3
P6
P5
P2 P1BORED ERECTION PAD
TO ENGINEER'S SPECIFICATIONSAND PAD R.L. 60.15
1000 HIGH STAINLESS STEEL WIREBALUSTRADE TO NCC REQUIREMENTS
SITE BOUNDARY
SITE BOUNDARY
SITE
BO
UN
DAR
Y
SITE BOUNDARY
900H TOPONLY
GARAGECONCRETE SLAB
(R.L. 62.40)
GARAGE NOTE :* RAKING CEILING WITH EXPOSED RAFTER* PREFABRICATED STEEL WITH COLORBOND SIDINGS ON CONCRETE SLAB.
D01
D02
D03
D03D03
D04
W01 W01
W02
W03
(UNCOVERED)F.F.L. -0.060 (R.L. 60.55)
RA
KIN
GC
EIL
ING
89 x 89mm SHS POST SUPPORTON 450Ø CONCRETE COLUMNTO ENGINEER'S SPECIFICATION
1200 WIDE RAKE EAVES (LINED)
VERANDAH CONSTRUCTION - 125 PFC &75x75 STEEL JOISTS ON 89 x 89 BEARERWITH 18mm HARDIE SHEET PANELON TOP TO COMPLY BAL-29
NOTE :GARAGE DOWNPIPE TO BE SEALED AND CHARGED
100 Ø PVC STORMWATER LINE FEEDING TO RAIN WATER TANK
ELECTRICMETER BOX
WALL MOUNTEDSOLAR INVERTER BOX
TAP
TAP
TAP
NB
N
ROBE
OVERHEADCUPB'DS
D06
ELEC. BOX (A/C & HWU)
EXTERNAL A/CON HARDSTAND
A/C INT. UNIT
DB
- POWER TO GARAGE (FROM SUB DIST. BOARD)
- SOLAR DC TO GARAGE (FROM SOLAR PANELS)
- DATA TO GARAGE(FROM PATCH BOARD)- SOLAR AC TO HOUSE
(TO METER BOX)
D05
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT
ALUMINIUM FRAME
WM TAPS 600H(UNDER B'TOP)
SHR
EXTENT OF CLEARPOLYCARBONATEROOFING SHOWN
SHADED
900 HIGHWORK BENCH
GAR
AGE
OPE
NIN
G
CARPETCARPET
TILESLAMINATE
TIMBER
LAMINATE TIMBER
EXTENT OF R1.7 INSULATION
34.2
44.2
4.1
4.1
2
1
4.35
2,46
52,
400
S/D
OO
R66
52,
000
VE
RA
ND
AH
7,53
0 V
ER
AN
DA
H
265
5,00
0 D
ININ
G/L
IVIN
G/K
ITC
HE
N26
5
5,53
0 P5
PAN
EL
7,53
0 O
VER
ALL
ELECTRIC HOTWATER SYSTEMON HARDSTAND
HOUSE AREA
Ground FloorLocation
HOUSE
VERANDAH
GARAGE
Area
77.59
35.79
22.20
135.58 m2
Perimeter
39.12
34.26
19.40
92.78 m
AREA [m2 ON THE FLAT] 129.29AREA [m2 ON THE RAKE] 130.87
ROOF AREAS
1:20CORNER JOINT DETAIL
NOM. 15mm GAP
REBAR TO ENG. DETAILS
CONSTRUCTION SEALANTON FOAM BACKING RODBOTH SIDES OF PANELRETURN INSULATION FOR
THERMAL CONTINUITY
1:20JOINT DETAIL
NOM. 15mm GAP CONSTRUCTION SEALANTON FOAM BACKING RODBOTH SIDES OF PANEL
NOTELOW EMMISSION PAINTS AND SEALANTS WILL BE USEDON >95% OF ALL INTERNAL AND EXTERNAL SURFACES
NOTE!! PLAN SCALED ON A2 PAPER
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
B
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B4.1ELEVATION 1 & 2 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
D39.1
2,10
0
1,200
450
2,40
0
2,40
0
COLORBOND BARGE & CAPPING
22,470 LITRE DUAL PURPOSE TANK(SIZE: 3400Ø x 22475mm HEIGHT)
RETAINING WALL (REFER SHEET 2.4)
COLORBOND BARGE & CAPPING
WIRE STAINLESS STEEL BALUSTRADEWITH HARD WOOD TOP BALUSTRADE
RAIL TO NCC REQUIREMENTSFOOT PATH
SELECTED SECTIONAL GARAGEROLLER DOOR WITH2 Nos. REMOTE CONTROLS
RIBBED STEEL CLADDING ONCONTINUOUS GIRTS AT 300mm
CONCRETE SLAB
DRIVEWAY WITH COMPACTEDFCR WITH GRAVEL OVERLAY
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT ALUMINIUM FRAME
89 x 89 SHS POST SUPPORTBEARERS FASTENED TO WALLWITH M16 BOLT SPACED AT 400mmTO ENGINEER'S SPECIFICATION
DOWNPIPE WITH LEAF TRAPAND FLUSH DIVERTER
SPLIT SYSTEM AIRCON EXTERNAL UNITON CONCRETE HARDSTAND
BRACING TO BOTTOM OF POSTTO ENGINEER'S DETAILS
OVERHEAD PRIVATEPOWER POLE CONNECTED
TO UNDERGROUNDSERVICE POWER RUN
PAINTED CONCRETE
D05
57.00 57
.25 57.50
57.50
56.75
56.50
COLORBOND ROOF 7° 00' 00" PITCH
D02
8.50 m BUILDING HEIGHT LIMIT
N.G.L. ON BOUNDARY
OP
EN
ING
VERANDAH NOTE :* GALVANISED STEEL FRAMED CONSTRUCTION
* 125mm PFC BOLTED TO WALL WITH M16 GALVANISED BOLTS4 OFF ON EACH JOINT EVENLY SPACED
* 89 x 89 SHS POSTS SUPPORT* 18mm HARDIE SHEET PANEL TO COMPLY BAL-29
EAVE
EAVE
SHALE GREY(EXTERNAL HOUSE, GARAGE& RAIN WATER TANK)
EXTERNAL FINISHES
DEEP OCEAN(ROOF & DECK POSTS)
FLAT WHITE(INTERIOR STUD WALLS &uPVC WINDOW FRAMES)
BARE CONCRETE(INTERIOR CONCRETE WALL)
CONCRETE SLAB(LIGHT COLOURED AGGREGATE)
COLORBOND ROOF 15° 00' 00" PITCH
GARAGE NOTE :THERE MUST BE A MINIMUM OF 50mm
CLEARANCE BETWEEN WALL CLADDINGAND GARAGE FLOOR LEVEL. IT IS NOTRECOMMENDED TO POUR CONCRETEDIRECTLY AGAINST WALL CLADDING.
R.L.60.150
R.L.60.550
R.L.62.360
R.L.63.000
R.L.62.400 R.L.62.507
2400
0
3119
2440 2400
0
460
3,52
7
7,41
7
3,84
4
400
3,98
7
400
1,00
0
GROUND FLOOR RL 60.61
SAND PAD R.L. 60.15
TOP OF ROOF
GARAGE FLOOR LEVEL RL 62.40
TOP OF ROOF
DIM
EN
SIO
N F
RO
M S
AN
D P
AD
1:100ELEVATION 1 (KESTREL STREET)
COLORBOND BARGE & CAPPING
EAVES LINED ON RAKE SEALED JOINT TO CONCRETE PANEL
WIRE STAINLESS STEEL BALUSTRADEWITH HARD WOOD TOP BALUSTRADE
RAIL TO NCC REQUIREMENTS
89 x 89 SHS POST SUPPORTBEARERS FASTENED TO WALL
WITH M16 BOLT SPACED AT 400mmTO ENGINEER'S SPECIFICATION
SEALED JOINT TO CONCRETE PANEL
CUT AREA
FILL AREA
IP66 EXTERNAL GPO
EAVES LINED ON RAKE
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT ALUMINIUM FRAMECOLORBOND ROOF 7° 00' 00" PITCH
D01
EXISTING N.G.L.
W01 W01
59.50
59.25
59.00
58.00
PAINTED CONCRETE
EXISTING N.G.L.
61.50
62.00
60.75
60.00
VERANDAH NOTE :* STEEL FRAMED CONSTRUCTION
* 125mm PFC BOLTED TO WALL WITH M16 GALVANISED BOLTS4 OFF ON EACH JOINT EVENLY SPACED
* 89 x 89 SHS POSTS SUPPORT* 18mm HARDIE SHEET PANEL TO COMPLY BAL-29
R.L.60.150R.L.60.550
R.L.60.150
2400
300
3119
2400
300
2400
0
1350 1350
460
3,52
7
3,57
9
400
1,00
0
GROUND FLOOR RL 60.61
SAND PAD R.L. 60.15
TOP OF ROOF
1:100ELEVATION 2
NOTELOW EMMISSION PAINTS AND SEALANTS WILL BE USEDON >95% OF ALL INTERNAL AND EXTERNAL SURFACES
BRICKY'S NOTE * ARTICULATIONS JOINTS TO ALL INTERNAL CORNERS. * COMPROMISE PERPS AND BEDS TO BE INSTALLED AS 3700. * CUT BRICKS IF NECESSARY. * DO NOT UNDER ANY CIRCUMSTANCE COMPROMISE PERPS AND BEDS. * LIFT WINDOWS TIGHT UNDER SIDE OF LINTEL BEFORE LAYING BRICK SILL.
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B4.2ELEVATION 3 & 4 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
1,200
450
COLORBOND BARGE & CAPPING
COLORBOND BARGE & CAPPING
WIRE STAINLESS STEEL BALUSTRADEWITH HARD WOOD TOP BALUSTRADERAIL TO NCC REQUIREMENTS
DOWNPIPE WITH LEAF TRAPAND FLUSH DIVERTER
METAL GUTTER & FASCIA
CUT AREA SPLIT SYSTEM AIRCON EXTERNAL UNITON CONCRETE HARDSTAND
RETAINING WALLT.O.W = R.L. 63.00(REFER SHEET 2.4)
CUT AREA
STEEL SHEET DOORTO GARAGE
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT ALUMINIUM FRAME
RIBBED STEEL CLADDING ONCONTINUOUS GIRTS AT 300mm
W03
COLORBOND ROOF 7° 00' 00" PITCH
DP
DP
PAINTED CONCRETE
EXISTING N.G.L.
61.00
62.2562
.50
62.00
EAVE
EAVE
(SAND PAD)
VERANDAH NOTE :* STEEL FRAMED CONSTRUCTION
* 125mm PFC BOLTED TO WALL WITH M16 GALVANISED BOLTS4 OFF ON EACH JOINT EVENLY SPACED
* 89 x 89 SHS POSTS SUPPORT* 18mm HARDIE SHEET PANEL TO COMPLY BAL-29
DP
GARAGE NOTE :THERE MUST BE A MINIMUM OF 50mm
CLEARANCE BETWEEN WALL CLADDINGAND GARAGE FLOOR LEVEL. IT IS NOTRECOMMENDED TO POUR CONCRETEDIRECTLY AGAINST WALL CLADDING.
COLORBOND ROOF 15° 00' 00" PITCH
R.L.60.150
R.L.60.550
2100
1300
3119
R.L.62.360
2440
460
3,52
7
3,76
9
GROUND FLOOR RL 60.61
SAND PAD R.L. 60.15
TOP OF ROOF
GARAGE FLOOR LEVEL RL 62.40SAND PAD R.L. 62.30
TOP OF GARAGE ROOF
DIM
EN
SIO
N F
RO
M S
AN
D P
AD
1:100ELEVATION 3
450
450
850 89 x 89 SHS POST SUPPORT BEARERS FASTENEDTO WALL WITH M16 BOLT SPACED AT 400mmTO ENGINEER'S SPECIFICATION
DRIVEWAY WITHCOMPACTED FRC + GRAVEL
WIRE STAINLESS STEEL BALUSTRADEWITH HARD WOOD TOP BALUSTRADERAIL TO NCC REQUIREMENTS
15mm SEALED JOINTTO CONCRETE PANEL
GARAGE BEYOND
PROPOSEDSAND PAD
COLORBOND BARGE & CAPPING
15mm SEALED JOINTTO CONCRETE PANEL
NBN CONNECTION- CONDUIT IN XPS
HOT WATERHEAT PUMP
CONDUIT IN XPS
SPLIT CYCLE AIR CONDITIONER- CONDUIT IN XPS
MAINS POWER SUPPLY- CONDUIT IN XPS
EARTH WIRE - CONDUIT IN XPS
POWER TO RAINWATER TANK PUMP- CONDUIT IN XPS
ELECTRICAL BOX
DOWNPIPE LINE TO BE "CHARGED LINEFULLY SEALED THROUGH GRAVITY PRESSURE
SPLIT SYSTEMAIRCON EXTERNAL UNIT
FILL AREA
CUT AREA
ELECTRIC HWS& HEAT PUMP
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT ALUMINIUM FRAME
RETAINING WALLT.O.W = R.L. 63.00(REFER SHEET 2.4)
OVERHEAD PRIVATEPOWER POLE CONNECTEDTO UNDERGROUNDSERVICE POWER RUN
W02
DP
59.00
60.00
61.00
63.00
58.00
57.00
EXISTING N.G.L.
PAINTEDCONCRETE
58.50
59.50
EAVE
EAVEELEC.M/BOX
E
POWER TO SUB-DISTRIBUTIONBOARD - CONDUIT IN XPS
COLORBOND ROOF 7° 00' 00" PITCH
VERANDAH NOTE :* GALVANISED STEEL FRAMED CONSTRUCTION
* 125mm PFC BOLTED TO WALL WITH M16 GALVANISED BOLTS4 OFF ON EACH JOINT EVENLY SPACED
* 89 x 89 SHS POSTS SUPPORT* 18mm HARDIE SHEET PANEL TO COMPLY BAL-29
D05
LEAF + FIRSTFLUSH DIVERTER
LEAF + FIRSTFLUSH DIVERTER
R.L.60.550R.L.60.150
2100
1200R.L.62.400
460
3,52
7
460
1,14
0
GROUND FLOOR RL 60.61
TOP OF ROOF
1:100ELEVATION 4
DOWNPIPE WITH LEAF TRAPAND FLUSH DIVERTER
SAND PAD R.L. 60.15
57.50
NOTELOW EMMISSION PAINTS AND SEALANTS WILL BE USEDON >95% OF ALL INTERNAL AND EXTERNAL SURFACES
BRICKY'S NOTE * ARTICULATIONS JOINTS TO ALL INTERNAL CORNERS. * COMPROMISE PERPS AND BEDS TO BE INSTALLED AS 3700. * CUT BRICKS IF NECESSARY. * DO NOT UNDER ANY CIRCUMSTANCE COMPROMISE PERPS AND BEDS. * LIFT WINDOWS TIGHT UNDER SIDE OF LINTEL BEFORE LAYING BRICK SILL.
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B4.3ELEVATION 5 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
DRIVEWAY WITH EXTERNAL CONCRETE
RETAINING WALL (REFER SHEET 2.4)
COLORBOND BARGE & CAPPING
SEALED JOINT TO CONCRETE PANEL
COLORBOND BARGE & CAPPING
WIRE STAINLESS STEEL BALUSTRADEWITH HARD WOOD TOP BALUSTRADE
RAIL TO NCC REQUIREMENTS
89 x 89 SHS POST SUPPORT BEARERS FASTENEDTO WALL WITH M16 BOLT SPACED AT 400mmTO ENGINEER'S SPECIFICATION
DOMESTIC WATER/FIRE FIGHTING TANK
RAINWATER TANK PUMP
BRACING TO BOTTOM OF POSTTO ENGINEER'S DETAILS
RIBBED STEEL CLADDING ONCONTINUOUS GIRTS AT 300mm
RETAINING WALLT.O.W = R.L. 62.70
RETAINING WALLT.O.W = R.L. 63.00
EAVES LINED ON RAKE
IP66 EXTERNAL GPO
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT ALUMINIUM FRAME
CLEAR POLYCARBONATE ROOFINGAT 15° 00' 00" PITCH
COLORBOND ROOF 15° 00' 00" PITCH
DRIVEWAY GRADIENT 59.50 59
.75 60.00 60
.25
59.25
59.00
58.00
DP
DP
61.00
62.00D01
W01
PAINTED CONCRETE
D02
W01
COLORBOND ROOF 7° 00' 00" PITCH
VERANDAH NOTE :* GALVANISED STEEL FRAMED CONSTRUCTION
* 125mm PFC BOLTED TO WALL WITH M16 GALVANISED BOLTS4 OFF ON EACH JOINT EVENLY SPACED
* 89 x 89 SHS POSTS SUPPORT* 18mm HARDIE SHEET PANEL TO COMPLY BAL-29
62.75
GARAGE NOTE :THERE MUST BE A MINIMUM OF 50mm
CLEARANCE BETWEEN WALL CLADDINGAND GARAGE FLOOR LEVEL. IT IS NOTRECOMMENDED TO POUR CONCRETEDIRECTLY AGAINST WALL CLADDING.
R.L.60.150
R.L.62.300
R.L.60.550
2400
300
1350
HOUSE R.L.60.610
3119
2400 2400
0 0
R.L.62.700R.L.63.000
460
3,52
7
6,19
7
GROUND FLOOR RL 60.61
SAND PAD R.L. 60.15
TOP OF GARAGE ROOF
GARAGE FLOOR LEVEL RL 62.40
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
TOP OF ROOF
1:100ELEVATION 5
22,470 LITRE SLIMLINERAIN WATER TANK ON FRC BED
NOTELOW EMMISSION PAINTS AND SEALANTS WILL BE USEDON >95% OF ALL INTERNAL AND EXTERNAL SURFACES
BRICKY'S NOTE * ARTICULATIONS JOINTS TO ALL INTERNAL CORNERS. * COMPROMISE PERPS AND BEDS TO BE INSTALLED AS 3700. * CUT BRICKS IF NECESSARY. * DO NOT UNDER ANY CIRCUMSTANCE COMPROMISE PERPS AND BEDS. * LIFT WINDOWS TIGHT UNDER SIDE OF LINTEL BEFORE LAYING BRICK SILL.
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B5.1ELECTRICAL PLAN 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
DW
REFWMDry
DP
DP DP
1100
135011001400
1100
600
8001800
1100
FW 1100
500
S
1100
D1S
S
C L
CL CLD12,710
600
EQ.
EQ.
DGPO FOR DW
GPO FOR GARAGE DOOR(CEILING MOUNTED)
LIVING
TAP
VERANDAH
DINING
BED 1BED 2
RO
BE
RO
BE
KIT
CH
EN
STUDYL'DRY
ENSN
BN
LED LIGHTING STRIPMOUNTED TO BOTTOM
OF WALL MOUNTEDCUPBOARDS
ELECTRIC METER BOX(CLIPSAL TASMANIA)
SOLAR INVERTER BOX
VERANDAH
TAP
TAP
WP/WL2000 AFLWP/WL
2000 AFL
- POWER TO GARAGE (FROM SUB DIST. BOARD)- SOLAR DC TO GARAGE (FROM SOLAR PANELS)- DATA TO GARAGE (FROM PATCH BOARD)- SOLAR AC TO HOUSE (TO METER BOX)
NOTE :GARAGE DOWNPIPE TO BE SEALED
AND CHARGED 100Ø PVC STORMWATERLINE FEEDING TO RAINWATER TANK
NOTE :HOUSE DOWNPIPE TO BE SEALED
AND CHARGED 100Ø PVC STORMWATERLINE FEEDING TO RAINWATER TANK
WP DGPO
LIGHT SWITCHCAST INTO 150mmLAYER
LIGHT SWITCHCAST INTO 150mmLAYER
CONDUIT TO GPO/TV POINTCAST INTO 150mm LAYER
WP DGPO FOR A/C
S3S1
MAINS PRIVATEELECTRICAL POLE
DB
S2
S1
S1S1
S1 S1
WP SGPOELECTRICAL PRE-LAY
WP SGPO
S1
S2
S2
DATA POINT FOR SOLAR INVERTER
5.1E1
5.1E2
EXTERNAL AIRCONON HARDSTAND RAIN WATER TANK PUMP
DUAL PURPOSE TANK22,470 LITRE ON FCR BED
ELECTRICAL BOX
ELECTRIC HWS& HEAT PUMP
ELECTRICAL LEGENDNo.
2
11
10
1
8
3
2
3
11
2
2
3
2
SYMBOL
S
TYPE1200 L SINGLE FLUORESCENT LIGHT
Double GPO @ 300AFL
Double GPO Noted HT AFL
Double WP GPO
External LED Downlight
External LED Spotlight
External LED Wall Light
H.WIRED SMOKE DETECTOR
Internal LED Downlight
LED Lighting Strip
Phone PT
Single GPO Noted HT AFL
Single WP GPO
1 NBN
LIGHTING CALCULATION - LOT 24 KESTREL STREET, PRIMPROSE SANDS
REGULATIONS AREA OF SPACE MAXIMUM WATTAGEALLOWANCE
WATT/UNIT
QTY.UNITS TOTAL COMPLIANCE
ACHIEVED - Y/N
5 W / m²IN A CLASS 1aBUILDING
77.59 m² 387.95 14 11 154 Y
4 W / m²ON VERANDAHOR BALCONY
34.59 m² 138.36 14 8 112 Y
3 W / m²IN A CLASS 10aBUILDING
21.60 m² 64.80 14 4 56 Y
NOTE :ALL SMOKE DETECTORS TO BEHARD WIRED AND INTERCONNECTED
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
7 SINGLE TOGGLE SWITCHS1
3 DOUBLE TOGGLE SWITCHS2
1 TRIPLE TOGGLE SWITCHS3
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B6.1SLAB & PLUMBING PLAN 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
WMDry
C L
C L
C L C L
CL
CL
CL
CL
C L
CL
CL
CL CL
C LC L
CLCL
C LC L
CL CL CL
CL
CL CL CL CL CL
CL CL CL CLCL
CL CL CL CL CL
DP
DP DP
FW
1,21
0
1,69
5
715
670
265
5,00
026
5
5,53
0
2,510 90 2,810
525
1,515
2,370
265 15 7,312 16 6,142 15 265
14,030
1,12
5
6,085
4,070
425
800
2,00
09,600
100
2,37
510
02,
375
100
2,38
010
0
100 2,250 100 2,300 100 2,300 100 2,250 100
7,53
0
180
600
600
600
600
600
600
600
600
600
1,95
0
14,030265 15 7,060 15 6,395 15 265
6,000
3,70
0
752,885
752,890
75
75
3,55
0
75
600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600
880 5,675 1,215 1,360 4,270 630
3,57
9
460
3,11
9
265 15 6,580 15 6,875 15 265
600
1,90
52,
575
450
900
600
4,33
060
0
3,57
9
460
3,11
9
2,90
0 3,57
9
460
3,11
9
2,90
0
865 4,000 2,940 1,500 2,210 1,500 1,015
460
2,40
0
460
300
2,10
0
4,465 600 465
460
1,10
080
0
2,465 2,400 665
460
2,40
0
265 5,000 265 265 5,000 265
2,90
0
265 15 7,312 16 6,157 265
6,075 1,200 5,435 470 850
460
1,20
090
0
265
5,00
026
5
5,53
0
630 4,270 1,360 1,215 5,675 880
14,030
600 4,330 600
5,530
600 1,905 2,575 450
5,530
880 3,057 3,057 1,215 4,941 880
14,030
460
460
1,14
068
0
6,060 1,200 5,450 470 850
415
600
4,51
5
1,015 1,500 2,210 1,500 2,940 4,000 865
2,46
52,
400
665
18mm HARDIE PANEL SHEETING1200mm x 2000 mm ON NORTH
WALL 1200mm x 3000mm ON THEEAST WALL SCREWED TO 75x50x2.5
RHS USING 12G/14G CSK METALSELF DRILL SCREWS GALV. COATED.SHEETS ARE TO BE JOINED ON THE
CENTRE LINE OF THE JOINTAT 1200mm CENTRES
GALVANISED STEEL FRAMEDCONSTRUCTION TO COMPLY BAL-29
PROPOSED RESIDENCEF.F.L. = 0.00 R.L. 60.61
BORED ERECTION PADTO ENGINEER'S SPECIFICATION
89 x 89mm SHS POST SUPPORTON 450Ø CONCRETE COLUMNTO ENGINEER'S SPECIFICATION
VERANDAHF.F.L. -0.060(R.L. 60.55)
P4P3
P6
P5
P2 P1
BORED ERECTION PADTO ENGINEER'S SPECIFICATION
SAND PAD R.L. 60.15
89 x 89mm SHS POST ON STEELPLATE BOLTED INTO 450ØCONCRETE COLUMN TOENGINEER'S SPECIFICATION
ELECTRICMETER BOX
SOLAR INVERTER BOX
TAP
TAP
TAP
LEGENDEE - ELECTRICAL ENTRY POINTIE - ISOLATED ELECTRIC POINTWC - TOILET PAN BOWL POINTVB - VANITY BASIN POINTKS - KITCHEN SINK POINTLS - LAUNDRY SINK POINTSP - SHOWER POINTFW - FLOOR WASTE POINT
NOTE :REFER TO ENGINEER'S DRAWINGSGARAGE
CONCRETE SLABF.F.L. AT R.L. 62.40
600 x 600 CENTRES POWDERCOATED ALUMINIUM FRAMEDCONSTRUCTION TO ENG. DETAILS
JOIST TO ENG. DETAILS
P1 P2
75 x 75 SHS POST SUPPORTTO ENGINEER'S SPECIFICATION
ELEVATION 1 - PANEL P1/P21:100
P6
ELEVATION 2 - PANEL P61:100
VOID (SLIDING DOOR)
VOID
(WIN
DOW)
VOID
(WIN
DOW)
VOID (WINDOW)P5
VOID (S
LIDIN
G DOOR)
ELEVATION 4 - PANEL P51:100
P3 P4
ELEVATION 3 - PANEL P3/P41:100
SEALED JOINT
SEALED JOINT
SEALED JOINT
SEALED JOINT
SEALED JOINT
SEALED JOINT
SEALED JOINT
SEALED JOINT
SEALED JOINT
SEALED JOINT SEALED JOINT SEALED JOINT
DUAL PURPOSE TANK22,470 LITRE ON FCR BED
VOID (METERBOX)
MAIN FRAME BEARERS PFC& STEEL JOISTS TO ENGINEER'SSPECIFICATION
NOTE :- DECK TO BE FABRICATED AND FULLY WELDED IN 4 SECTIONS TO ALLOW FOR GALVANIZING- MAIN FRAME BEARERS 125mm PFC, JOISTS 75 x 50 x 2.5mm RHS- 2x 4800mm x 2000mm- 2x 5535mm x 1500mm- DECK SECTIONS ARE TO BE BOLTED TOGETHER USING M16 8.8 GALVANISED BOLTS- 2 OFF M16 BOLTS, 80mm CENTRES ON MIDDLE LINE OF PFC ON EACH BACK PFC SPACED AT 1000mm CENTRES ALONG THE FULL LENGTH OF THE JOINT.
SECTION 1 SECTION 2
SEC
TIO
N 3
SEC
TIO
N 4
SOLARINVERTER BOX
RETAINING WALLT.O.W. = R.L. 63.00
RETAINING WALLT.O.W. = R.L. 63.00
RETAINING WALLT.O.W. = R.L. 62.70
C L
CL CL CL
C L
1,89
0
565
880 3,057 3,057 1,215 4,941 880
ELECTRICAL BOX
RAIN WATER TANK PUMP
VB
WC
FW
SHR
TR
SHR
WC
FWVB
VOID
(WINDOW)
EXTERNAL A/CON HARDSTAND
WINDOW M/BOX
WIN
DO
W
WINDOWWINDOW SLIDING DOOR
SLI
DIN
G D
OO
R
NOTE!! PLAN SCALED ON A2 PAPER
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B7.1SECTIONS 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
450450
COLORBOND BARGE & CAPPING
WIRE STAINLESS STEEL BALUSTRADEWITH HARD WOOD TOP BALUSTRADERAIL TO NCC REQUIREMENTS
89 x 89 SHS POST SUPPORTBEARERS FASTENED TO WALLWITH M16 BOLT SPACED AT 400mmTO ENGINEER'S SPECIFICATION
RAKING PLASTERBOARD CEILINGON METAL FURRING CHANNEL
110mm THK CONCRETE SLABWITH 50mm XPS UNDERFLOORINSULATION
PROPOSEDSAND PAD R.L. 60.15
TIMBER FRAMED WALL
CONCRETE SANDWICH PANELWITH 50mm XPS (R.2.7 BATTS) INSULATION
PROPOSED N.G.L. DRIVEWAY WITHEXTERNAL CONCRETE
EXISTING N.G.L.
FIBREGLASS OR ROCKWOOL+ R 4.0 +1.4 BATTS CEILINGINSULATION
1:100 FALL (MIN.)
GARAGE BEYOND
COLORBOND BARGE & CAPPING
PROPOSED N.G.L.
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT ALUMINIUM FRAME
BED 2 BED 1KITCHEN
LIVING/DINING
VERANDAH
COLORBOND ROOF 7° 00' 00" PITCH
D01
VERANDAH NOTE :POWDER COATED ALUMINIUM FRAMED CONSTRUCTIONWITH 18mm HARDIE SHEET PANEL TO COMPLY BAL-29
EAVE
D02
W01
W01
RO
BE
RO
BE
EAVE
59.00
60.00
61.00
62.00
58.00
57.00
EXISTING N.G.L.
57.50
58.50
59.50
SAND FILLED
R.L.60.550R.L.60.610 (FFL=0.00)
R.L.60.150
460
3,52
7
275
7511
0
460
GROUND FLOOR RL 60.61
SAND PAD R.L. 60.15
TOP OF ROOF
1:100SECTION A-A
450
1,200
89 x 89 SHS POST SUPPORTBEARERS FASTENED TO WALLWITH M16 BOLT SPACED AT 400mmTO ENGINEER'S SPECIFICATION
110mm THK CONCRETE SLABWITH 50mm XPS UNDERFLOORINSULATION
PROPOSEDSAND PAD R.L. 60.15
BORED ERECTION PAD WITHCORED OR CAST-IN Ø50mm
GROUT FILLED TUBE TOENGINEER'S SPECIFICATION
CONCRETE SANDWICH PANELWITH 50mm XPS (R.2.7 BATTS) INSULATIONFIBREGLASS OR ROCKWOOL
+ R 4.0 +1.4 BATTS CEILINGINSULATION
1:100 FALL (MIN.)
COLORBOND BARGE & CAPPINGLEAF + FIRST
FLUSH DIVERTER
RAKING PLASTERBOARDCEILING ON METALFURRING CHANNEL
60 CELL PHOTOVOLTAIC PANELSMOUNTED ON REVERSE-TILT ALUMINIUM FRAME
COLORBOND ROOF 7° 00' 00" PITCH
D03
EAVE
KITCHEN
EAVE
SAND FILLED
VERANDAH NOTE :* GALVANISED STEEL FRAMED CONSTRUCTION
* 125mm PFC BOLTED TO WALL WITH M16 GALVANISED BOLTS4 OFF ON EACH JOINT EVENLY SPACED
* 89 x 89 SHS POSTS SUPPORT* 18mm HARDIE SHEET PANEL TO COMPLY BAL-29
R.L.60.550R.L.60.610 (FFL=0.00)
R.L.60.150
2440
3119
460
3,52
7
275
7511
0
460
GROUND FLOOR RL 60.61
SAND PAD R.L. 60.15
TOP OF ROOF
820 CSD
1:100SECTION B-B
CONCRETE FOOTING TOENGINEER'S SPECIFICATION
RAKE ROOF CEILING
RETAINING WALL(REFER SHEET 2.4)
SELECTED SECTIONAL GARAGEDOOR WITH 2 No. REMOTE CONTROLS
RIBBED STEEL CLADDING ONCONTINUOUS GIRTS AT 300mmCONCRETE SLAB
DRIVEWAY WITHEXTERNAL CONCRETE
CLEARPOLYCARBONATE
ROOFING
WORK STATION
D06
COMPACTED FILL
COLORBOND BARGE & CAPPING
GARAGE
COLORBOND ROOF 15° 00' 00" PITCH
GARAGE NOTE :THERE MUST BE A MINIMUM OF 50mm
CLEARANCE BETWEEN WALL CLADDINGAND GARAGE FLOOR LEVEL. IT IS NOTRECOMMENDED TO POUR CONCRETEDIRECTLY AGAINST WALL CLADDING.
R.L.62.400
2,85
1 N
OM
.
2,10
0
GARAGE FLOOR LEVEL RL 62.40
1:100SECTION C-C
NOTELOW EMMISSION PAINTS AND SEALANTS WILL BE USEDON >95% OF ALL INTERNAL AND EXTERNAL SURFACES
BRICKY'S NOTE * ARTICULATIONS JOINTS TO ALL INTERNAL CORNERS. * COMPROMISE PERPS AND BEDS TO BE INSTALLED AS 3700. * CUT BRICKS IF NECESSARY. * DO NOT UNDER ANY CIRCUMSTANCE COMPROMISE PERPS AND BEDS. * LIFT WINDOWS TIGHT UNDER SIDE OF LINTEL BEFORE LAYING BRICK SILL.
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
B
B
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B8.1KITCHEN & ROBE 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
4 x 450WDRAWERS
DWREC
2 x 450WDRAWERS
2 x 480WDRAWERS
820
CS
D
FR REC.
C L
C L
CL
460
2,44
0
600
300
760
900
600
600
2,10
0
1,80
030
0
460
110mm THK CONCRETE SLAB OVERPLASTIC VAPOUR BARRIER OVER30mm SAND BLINDING OVER 100mmFCR OVER SAND FILL ON TOP OF PAD(REFER DETAIL SHEET 9.1)
K1
UBO
GROUND FLOOR RL: 60.61 m
BANK OF2 DRAWERS
BANK OF4 DRAWERS
ELEC. COOKTOP
CHARCOALFILTER EXTRACTOR
300 DEEP O/HEAD CUPBOARDSWITH GLASS INFILL PANELS
SHELF
SHELF
MIXER
DWRECESS
DGPO
COLD TAP
SHELFNO SHELF
REF. RECESS
820 CSD
LAMINATEEND PANEL
SAND PAD RL: 60.150 m
R.L.60.610 (FFL=0.00)
R.L.60.150 460
900
600
600
110mm THK CONCRETE SLAB OVERPLASTIC VAPOUR BARRIER OVER30mm SAND BLINDING OVER 100mmFCR OVER SAND FILL ON TOP OF PAD(REFER DETAIL SHEET 9.1)
K2
GROUND FLOOR RL: 60.61 m
BANK OF 2 DRAWERS
ELEC. COOKTOP
CHARCOAL FILTER EXTRACTOR
300 DEEP O/HEAD CUPBOARDSWITH GLASS INFILL PANELSSH
MIXER
BARECONCRETE
SAND PAD RL: 60.150 m
R.L.60.610 (FFL=0.00)
R.L.60.150
1: 50KITCHEN PLAN
2
1 KC LC L
1686
816
900
790
1,46
086
0
480
620
450
450
500
610
320
940
1,85
0
3,11
0
300 300
600
300 300
600
FR R
EC
ES
S
KS
RA
KIN
GC
EIL
ING
300 DEEP O/HEAD CUP'BDS
300 DEEP O/HEAD CUP'BDS
ELEC. HPUBO
CHARCOALFILTER EXTRACTOR
300 DEEP O/HEAD CUP'BDS
EX
TRA
CTO
RO
'HE
AD
SO
'HE
AD
S
BEN
CH
TOP
O/A
LL
DW
RE
C.
DR
WD
RW
UB
OD
RW
O'HEADS
O'HEADS
B'TOP
LAMINATE END PANEL
450
450
450
450
1,80
0
16 468 16
500 800
16 468
400mm DEEP SHELF
HANGING RAILS
4x 400mm DEEP SHELVES
ROBEBED 1 & 2
GROUND FLOOR RL: 60.61 m
BANK OF 3 DRAWERS
1 : 50
3 x 605WDRAWERS
1: 50TYP. ROBE PLAN
500
700
600
1,80
0
400
1x 400 DEEP SHELF AT 1800HW/- BANK OF 3 DRAWERS BELOW
4x 400 DEEP SHELVES AT 1800H
1x 400 DEEP SHELF AT 1800H
NOTELOW EMMISSION PAINTS AND SEALANTS WILL BE USEDON >95% OF ALL INTERNAL AND EXTERNAL SURFACES
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B8.2ENSUITE & LAUNDRY 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ETC L
600
1,50
0
900
600
600
460
1,50
060
0
110mm THK CONCRETE SLAB OVERPLASTIC VAPOUR BARRIER OVER
30mm SAND BLINDING OVER 100mmFCR OVER SAND FILL ON TOP OF PAD
(REFER DETAIL SHEET 9.1)
L1
GROUND FLOOR RL: 60.61 m
DRYERSPACE
WM TAPS
WMSPACE
SHELF
MIXER
SHELF
300 DEEP O/HEAD CUPBOARDSWITH GLASS INFILL PANELS
NO
MIN
AL
BARE CONCRETE
SAND FILLED
RAKING CEILING WITH COVE CORNICE
SAND PAD RL: 60.150 m
R.L.60.610 (FFL=0.00)
R.L.60.150
1 : 50
720
820 CSD
WM
Dry
FW
DB
1
L
1: 50ENSUITE & L'DRY PLAN
3
4
1
2 E
C LC L
CL CL
C L
1: 50
C L
450
980
460
970
920
1,610 900 400 805
800 2,010
600
500
405
200
900
TR
VB
SHR
MIXER
SHR
RA
KIN
GC
EIL
ING
WM TAPS MIXER
WM SPACE TROUGH BROOM
VAN
ITY
VANITY
RA
KIN
GC
EIL
ING
WC
T/RAILAT 1000H
TRH AT 650H
2100 HIGH OPENING
300 DEEPO/HEADCUP'BDS
SHR SCREEN& PIVOT DOOR
870
200
1,03
0
2,10
0
460
TISSUE ROLL HOLDER AT 650H
110mm THK CONCRETE SLAB OVERPLASTIC VAPOUR BARRIER OVER
30mm SAND BLINDING OVER 100mmFCR OVER SAND FILL ON TOP OF PAD
(REFER DETAIL SHEET 9.1)
E1
GROUND FLOOR RL: 60.61 m
SHELF
MIRROR
WINDOW
BARE CONCRETE
RAKING CEILING
WC
MIXER
TOWEL RAIL
SAND FILLEDSAND PAD RL: 60.150 m
R.L.60.610 (FFL=0.00)
R.L.60.150
C L
C L
C L
1,00
0
460
870 90
0
2,00
0
2,10
0
2,20
0
110mm THK CONCRETE SLAB OVERPLASTIC VAPOUR BARRIER OVER30mm SAND BLINDING OVER 100mmFCR OVER SAND FILL ON TOP OF PAD(REFER DETAIL SHEET 9.1)
MIXER
SH
R S
CR
EE
N
E2
GROUND FLOOR RL: 60.61 m
WINDOW
RAKING CEILING
TOWEL RAILAT 900 H
WC
MIXER
HANDHELD
SHOWER
SH
R R
AIN
HE
AD
OU
TLE
T
HA
ND
HE
LD S
HR
MIX
ER
CONC. HOB
SAND FILLEDSAND PAD RL: 60.150 m
R.L.60.610 (FFL=0.00)
R.L.60.150
C L
C L
1,00
0
2,00
0
2,10
0
2,20
0
460
110mm THK CONCRETE SLAB OVERPLASTIC VAPOUR BARRIER OVER
30mm SAND BLINDING OVER 100mmFCR OVER SAND FILL ON TOP OF PAD
(REFER DETAIL SHEET 9.1)
E3
GROUND FLOOR RL: 60.61 m
720 DOOR
BARE CONCRETERAKING CEILING
MIXER
SH
R S
CR
EE
N
HANDHELD
SHOWER
SH
R R
AIN
HE
AD
OU
TLE
T
HA
ND
HE
LD S
HR
MIX
ER
SAND FILLEDSAND PAD RL: 60.150 m
R.L.60.610 (FFL=0.00)
R.L.60.150
C L
C L1,
000
2,00
0
2,10
0
460
2,20
0
110mm THK CONCRETE SLAB OVERPLASTIC VAPOUR BARRIER OVER
30mm SAND BLINDING OVER 100mmFCR OVER SAND FILL ON TOP OF PAD
(REFER DETAIL SHEET 9.1)
TRHSH
R S
CR
EE
N
BARE CONCRETE
E4
GROUND FLOOR RL: 60.61 m
WINDOW
RAKING CEILING
WC
MIXER
HANDHELD
SHOWER
SH
R R
AIN
HE
AD
OU
TLE
T
HA
ND
HE
LD S
HR
MIX
ER
CONC. HOB
SAND FILLEDSAND PAD RL: 60.150 m
R.L.60.610 (FFL=0.00)
R.L.60.150
NOTELOW EMMISSION PAINTS AND SEALANTS WILL BE USEDON >95% OF ALL INTERNAL AND EXTERNAL SURFACES
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B9.1STANDARD DETAILS - 1 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
AS SHOWN
R4.0 + 1.4 BATTS INSULATION
R4.0 + 1.4 BATTS INSULATION
R1.7 BATTS INSULATION
R1.7 BATTS INSULATION
75mm XPSR2.7 BATTS INSULATION
R1.7 BATTS INSULATION
R1.7 BATTS INSULATION
75mm XPSR2.7 BATTS INSULATION
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
B
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B9.2STANDARD DETAILS - 2 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
AS SHOWN
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
REV
ISIO
NS
NORTH: JOB NUMBER:
JOB ISSUE:
SHEET NUMBER:SCALE:
DRAWN:
CHECKED:
DATE:
Level 2, 420 Collins Street, Melbourne, VIC 3000Phone: 61 3 8687 2118
Email: [email protected]
S I G
N 0
F F
C L I E N T GENERAL NOTES:
P R
O
J
E
C
T
CLIENT:
PROPERTY ADDRESS:
HOUSE TYPE:
SHEET CONTENT:
SIGNED...................................................... DATE.................
.................................................................................................
CONFIRM THESE DRAWINGS ACCORD WITH OUR REQUIREMENTS ANDAUTHORISE THEIR USE FOR NEXT STAGE PURPOSES.
I / WE.......................................................................................
SIGNED...................................................... DATE.................
THE CONTRACTOR IS RESPONSIBLE FOR SETTING OUT ANDCHECKING ALL LEVELS AND DIMENSIONS ON SITE PRIORTO COMMENCING ANY SITE WORKS.
A.L. & S.L. TERHORST
FIGURED DIMENSIONS ARE TO TAKE PREFERENCE OVERSCALE
UNLESS OTHERWISE DIMENSIONED ALL STUD WALL ARE90mm THICK AND ALL BRICK VENEER WALLS ARE 240mmTHICK.
DIMENSIONS TO STRUCTURAL TIMBERS & FACE OF BRICKSEXCLUDING BATTENS, PLASTERBOARD ETC.
REFER TO ENGINEERS DETAILS FOR STRUCTURALMEMBERS.
*
*
*
*
*
1 : 100
B10.1WINDOW & DOOR SCHEDULE 19-0076ETMS
2019
LOT 24 KESTREL STREET,
CUSTOM
PRIMROSE SANDS
ISSUE DATE REVISION DESCRIPTION INITIALSA 13/09/19 BUILDING LICENCE ETBCDKLMN
DP-AD 45334TAS 400648168QLD 15127260
18/09/19 6 STAR ENERGY REPORT ET
W01 W02 W03
1,500x2,100 1,200x900 600x800
2 1 1
Door Number
W x H Size
Quantity
D01 D02
4,000x2,400 2,400x2,400
1 1
Window Number
W x H Size
Quantity
1 : 50
D03 D04 D05 D06
880x2,100 830x2,100 830x2,100 2,440x2,100
3 1 1 1
Type Garage Steel Door(with Remote Control)uPVC Framed Sliding Door Timber Framed
Cavity Sliding Door
DOOR SCHEDULE
uPVC FramedAwning WindowType
uPVC Framed Sliding Door Timber FramedSolid Door
WINDOW SCHEDULE
NOTE :
BAL-29 PVC DOUBLE SIDED GLAZED WINDOWS WITH 6mm CLEAR INSULGLASSU-value = 2.09 | SHGC = 0.42 - REFER TO 6 STARS ENERGY REPORT
DRAWINGS TO BE READ IN CONJUCTION TO ENGINEERING DRAWINGS.
uPVC FramedAwning Window
uPVC FramedAwning Window
Double Sided Glazing Double Sided Glazing
Double Sided Glazing
Double Sided Glazing Double Sided Glazing
Steel Framed Door
(Bathroom)(Bedroom/Passage) (Garage)B