DESMI priming ejector.pdf

2
Function: Compressed air will flow through the ejector D and create a vacuum in the pump casing and suction line. After priming, the pumps will build up pres- sure in the discharge line which will activate the presure switch F . The presssure switch then dis- connect the power to the solenoid valves E and the priming stops automati- cally. At a fluid pressure of e.g. 10 m total head the unit will disconnect automati- cally (adjustable from 3 - 100 m total head). If the pressure drops to less than 10 m total head the unit will automatically start functioning until a counter pressure has been reestablished. DESMI priming ejector DESMI Danmark A/S Tagholm 1 DK-9400 Nørresundby Phone: + 45 72 44 02 50 Fax: + 45 98 17 54 99 Internet: www.desmi.dk E-mail: [email protected] The DESMI priming ejector is designed for mounting on non-selfpriming centrifu- gal pumps thus making the pump unit self-priming. In order to make the unit work, the delivery pipe has to be shut off, e.g. by means of a non-return valve A Drain B Air Inlet C Check valve D Ejector E Solenoid valve F Pressure switch G Connection with suction line D E A F C B E G

description

Desmi Ejector

Transcript of DESMI priming ejector.pdf

Page 1: DESMI priming ejector.pdf

Function:Compressed air will flow through the ejector D andcreate a vacuum in the pump casing and suction line. After priming, the pumps will build up pres-sure in the discharge line which will activate the presure switch F . The presssure switch then dis-connect the power to the solenoid valves E and the priming stops automati-cally.

At a fluid pressure of e.g. 10 m total head the unit will disconnect automati-cally (adjustable from 3 - 100 m total head). If the pressure drops to less than 10 m total head the unit will automatically start functioning until a counter pressure has been reestablished.

DESMI priming ejector

DESMI Danmark A/STagholm 1DK-9400 NørresundbyPhone: + 45 72 44 02 50Fax: + 45 98 17 54 99Internet: www.desmi.dkE-mail: [email protected]

The DESMI priming ejector is designed for mounting on non-selfpriming centrifu-gal pumps thus making the pump unit self-priming.

In order to make the unit work, the delivery pipe has to be shut off, e.g. by means of a non-return valve

A Drain

B Air Inlet

C Check valve

D Ejector

E Solenoid valve

F Pressure switch

G Connection with suction line

D

E

A

F

C

B E

G

Page 2: DESMI priming ejector.pdf

DESMI A/STagholm 1DK-9400 NørresundbyPhone: + 45 96 32 81 11Fax: + 45 98 17 54 99Internet: www.desmi.comE-mail: [email protected]

- contact us for further information

The DESM priming ejec-tor is available in sizes 1/2” or 1”. Ejectors can be supplied with one or two solenoid valves. Depend-ing on the specific task.