Effectiveness of the Telemetric Flood Monitoring Device
______________________________________________________________
Computer Engineering Department
College of Engineering Education
University of Mindanao
![Page 2: Design project](https://reader036.fdocuments.net/reader036/viewer/2022082805/54bf17a54a795908368b4583/html5/thumbnails/2.jpg)
Statement of the Problem
This study is to establish the best telemetric design for a flood monitoring device.
Specifically, to answer the following questions:
Effectiveness of the Telemetric Flood Monitoring Device
![Page 3: Design project](https://reader036.fdocuments.net/reader036/viewer/2022082805/54bf17a54a795908368b4583/html5/thumbnails/3.jpg)
Statement of the Problem
1. What is the average values using the following parameters:
a) Water level, and
b) Response time of the system?
2. What are the physical specifications of the designs?
Effectiveness of the Telemetric Flood Monitoring Device
![Page 4: Design project](https://reader036.fdocuments.net/reader036/viewer/2022082805/54bf17a54a795908368b4583/html5/thumbnails/4.jpg)
Statement of the Problem
3. How much would cost to develop the designs?
4. What is the significant difference between the reading in terms of:
a) Water level, and
b) Response time of the system?
Effectiveness of the Telemetric Flood Monitoring Device
![Page 5: Design project](https://reader036.fdocuments.net/reader036/viewer/2022082805/54bf17a54a795908368b4583/html5/thumbnails/5.jpg)
Conceptual Framework
TYPES OF DESIGN
1) Floating Sensor2) Ultrasonic Sensor
EFFECTIVENESS
a) Water Level Reading
b) Response Time
Effectiveness of the Telemetric Flood Monitoring Device
![Page 6: Design project](https://reader036.fdocuments.net/reader036/viewer/2022082805/54bf17a54a795908368b4583/html5/thumbnails/6.jpg)
Research Procedure
1. Test Effectiveness in:
a) Water Level Readings:
i. Actual Reading (human)
ii. Displayed Reading (LCD/ Indicator)
iii. Transmitted Reading (Server)
b) Response time : Critical Water Level
Two test per trial
c) 30 trials
Effectiveness of the Telemetric Flood Monitoring Device
![Page 7: Design project](https://reader036.fdocuments.net/reader036/viewer/2022082805/54bf17a54a795908368b4583/html5/thumbnails/7.jpg)
Research Procedure
2. After the tally of readings and time,
a) The specific component used and
b) The actual cost
Effectiveness of the Telemetric Flood Monitoring Device
![Page 8: Design project](https://reader036.fdocuments.net/reader036/viewer/2022082805/54bf17a54a795908368b4583/html5/thumbnails/8.jpg)
Effectiveness of the Telemetric Flood Monitoring Device
______________________________________________________________
Harold A. Caparida
Jhun Bryan V. Cenabre
Raldey T. Lape
January 17, 2012