Design and Detailing of Seismic Connections for Braced Frame Structures[1]

download Design and Detailing of Seismic Connections for Braced Frame Structures[1]

of 19

Transcript of Design and Detailing of Seismic Connections for Braced Frame Structures[1]

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    1/19

    Design andDetailing of

    SeismicConnections for

    Braced FrameStructures

    Terry R. Lundeen

    Author

    Terry Lundeen is a principalwith the structural engineeringfirm of Coughlin Porter Lundeen,Inc., in Seattle. His experienceover the past 20 years includesthe design of numerous building

    structures as well as deep water offshore platforms and large air-craft assembly facilities. Hereceived his bachelor of sciencein civil engineering from BradleyUniversity in 1980 and his master of science in civil engineeringfrom the University of Houston in1985.

    Mr. Lundeen has a specialinterest in seismic design andretrofit of structures, he is activein the development of seismicdesign provisions for the UniformBuilding Code through theStructural Engineers Associationof Washington and for the federalNEHRP documents through theBuilding Seismic Safety Counciland the American Society of CivilEngineers. He contributes to thepreparation of the Western StatesStructural Engineers Exam andlectures on the seismic design of steel structures at the Universityof Washington. He is a registeredstructural engineer in California,Washington and British Columbia.

    Summary

    A s a result of lessons learnedfrom recent earthquakes(Loma Prieta, Northridge, Kobe)as well as on-going research, theseismic design and detailing of braced frame connections hasevolved significantly over the pastten years.

    Using an example office build-ing, this paper presents thedesign of braced frame connec-tions according to the recentlyreleased 1997 Edition of theSeismic Provisions for Structural Steel Buildings by AISC. Theexamples include various types of brace connections and columnsplices for SpeciallyConcentrically Braced Frames,Ordinary Concentrically Braced

    25-1

    Frames and Eccentrically BracedFrames. The seismic designapproach and details are basedon practical implementation of thecurrent provisions on numerouscommercial, industrial, education-al and residential buildings.

    2003 by American Institute of Steel Construction, Inc. All rights reserved.This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    2/19

    DESIGN AND DETAILING OF SEISMIC CONNECTIONSFOR BRACED FRAME STRUCTURES

    TERRY R. LUNDEEN

    INTRODUCTION

    This paper presents the design and detailing of braced frame connections for seismic loading. A prototype 4-story office building in Seismic Zone 3is used as the basis for the examples. A typicalfloor framing plan with braced frame locations isgiven in Figure 1.

    The examples include the three basic braced frametypes: Special Concentrically Braced Frames(SCBF), Ordinary Concentrically Braced Frames(OCBF), and Eccentrically Braced Frames (EBF).A variety of brace types are provided including

    pipes, structural tubes, and wide flanges.Additionally, both welded and bolted connectionsare provided for reference.

    Table 1General Criteria

    Code:

    Structure:

    MaterialSpecifications:

    Loads:

    AISC Seismic Provisions for Structural Steel Buildings

    AISC Manual for Load &Resistance Factor Design

    Office building Located in Seismic Zone 3 Soil profile type Sc The frame configuration are

    as follows:1. Special Concentrically

    Braced Frame; R = 6.42. Ordinary Concentrically

    Braced Frame; R = 5.63. Eccentrically Braced

    Frame; R = 7

    Steel framing A572, Grade 50 High-strength A325/A490

    bolts Welding Electrodes: E70

    Roof Dead Load = 20psf Roof Live Load = 25psf Floor Dead Load = 80psf Floor Live Load = 80psf

    (reducible)

    The overall forces on the structure are based on the1997 Edition of the Uniform Building Code. Thedesign of steel members and connections is based on the AISC Seismic Provisions for SteelBuildings, dated April 17, 1997. A list of thegeneral design criteria is given in Table 1.

    While most of the new code provisions are similar to those of older versions, there have been somechanges and updates. These changes includeexplicit consideration of material overstrength and more direct integration of the AISC SeismicProvisions into the model building codes.Additional, more detailed, revisions are also

    presented in this paper.

    While the subject of the paper is connection design, brace and column member issues that directlyeffect the connections are discussed. The detaileddesign of these members, however, is not provided.

    Figure 1 - Typical Floor Plan

    25-3 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    3/19

    SPECIAL CONCENTRICALLY BRACEDFRAME (SCBF) CONNECTION DESIGN

    For this system, a frame consisting of welded pipe braces and a frame consisting of bolted wide flange braces are provided. Frame elevations for bothconfigurations are given in Figures 2 and 3. The

    braces are arranged in a Chevron pattern both because it represents the most commonly used arrangement and because of the additional designconsiderations given in the Provisions.

    For a building of this size, the welded pipeconfiguration is preferable both from a design and construction perspective. The bolted wide flangeconfiguration is given as a reference for largestructures with brace forces that cannot beaccommodated with pipes. Similarly, the strongaxis column orientation given in the first frame isdesirable; however, a weak axis columnarrangement is also provided for reference.

    The SCBF is a newer version of the traditionalsteel braced frame. This system was developed to

    provide documented ductility, both analytically and through testing. In general, yielding and column buckling of the braces provide this ductility. Inorder for this behavior to be achieved, local

    buckling in the braces or connections cannot occur.

    Another requirement to guarantee the desirable behavior of this system is to preclude plastic hingeformation in Chevron beams under unbalanced

    brace buckling and yielding forces. Also, the beamflanges at Chevron connections must be braced out-of-plane.

    The connections in SCBF's must be stronger thanthe yielding members. For this system, theconnections must also have either the strength todevelop a strong axis plastic hinge or be arranged to allow a weak axis yield line to form under thecyclic yielding and buckling of the braces.

    A final consideration for this system is with thecolumns. In addition to having the strength toresist axial forces from the amplified earthquakeload combinations, the columns and splices aredesigned for a nominal shear force in the column.This shear strength requirement is provided

    because plastic hinges formed in the columns atlarge story drifts in some of the initial analyticalanalyses of the system.

    Figure 2 - SCBF Elevation

    Figure 3 - Frame Elevation

    25-4 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    4/19

    WELDED PIPE BRACE-TO-WIDE FLANGECOLUMN CONNECTION (Fig. 4)

    Required Strength

    The required strength of bracing connections, per

    AISC Sec. 13.3.a, is determined from the least of the following equations:

    1. Bracing member's nominal axial tensilestrength:

    where equals 1.1 per AISCSec. 6.2.

    Figure 4 - Welded Pipe Brace-to-Wide FlangeColumn Connection

    2. Maximum force, transferred to brace by system as determined by analysis

    Brace-to-Gusset WeldThe required weld thickness for the brace-to-gusset, assuming 12 in. of weld along (4) edges:

    Use 12" of " weld on (4) edges

    The weld thicknesses are relatively large tolimit the extension of the gusset plates beyond the yield line.

    Gusset-to-Beam and Column Welds

    Using the Uniform Force Method as recommended per LRFD Vol. II Part 11, the axial force from the brace is resolved into the corresponding moment,horizontal, and vertical forces on the gusset plate.This is shown on the free body diagram of thegusset plate Fig. 5.

    As can be seen, the connection force to thebeam is much larger than that to the column.

    As such, larger welds are used at the beam

    flange to control the size of the gusset plate.

    Figure 5 Gusset-to-Beam and Column Weld Forces

    25-5

    Case 1 is normally used in design since Case 2basically requires static push-over analysis or non-linear time history analysis to establishthe maximum system force.

    This connection was designed with a "yield line" a distance of 2t from the brace in lieu of the flexural strength requirements of Section13.3c.

    2003 by American Institute of Steel Construction, Inc. All rights reserved.This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    5/19

    Weld of gusset-to-beam flanges

    Use " weld for gusset to beam flanges.

    Weld of gusset to column

    Use " weld for gusset to column.

    Gusset Plate Thickness

    Per AISC Sec. 13.3.b: The design tensile strength,determined from the limit states of tension ruptureand block shear rupture strength per LRFD Chapter D, shall be greater than or equal to the required strength, as determined from above.

    Also, the design compression strength, determined from the plate buckling limit state, shall be greater than the buckling strength of the brace which isgiven from the following:

    Finally, the plate must have adequate shear yielding strength for the designed fillet weld sizes.

    Table 2

    Criteria

    Block Shear

    Tension Yielding

    Plate Buckling

    Shear Yielding atFillet Welds

    Required Gusset PlateThickness (in)

    .42

    .41

    .54

    .71

    Use " gusset plate

    Once the overall dimensions of the gusset plate are established by the welds and yield line, the thickness is determined from thevarious remaining criteria.

    25-6 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    6/19

    WELDED PIPE BRACE-TO-BEAMCONNECTION (Fig. 6)

    The beam flanges of this connection must bebraced out-of-plane per AISC Sec. 13.4a.4.

    Perpendicular floor beams or angle bracing

    similar to that shown in the EBF section canbe used to provide this bracing.

    Required Strength

    The required strength is the same as for the pipe-to-column connection.

    Brace-to-Gusset Weld

    The brace-to-gusset weld is the same as for the pipe-to-column Connection.

    Gusset-to-Beam Weld

    Figure 7 - Gusset-to-Beam Weld Forces

    Gusset Plate Thickness

    The minimum gusset plate thickness follows thesame procedures as for the pipe-to-columnconnection.

    Check minimum thickness of gusset

    From pipe to gusset:

    From gusset to beam:

    The Chevron beam is quite deep to provide the required strength for theunbalanced brace loads. This depthresults in a relatively long gusset platewith large bending stresses.

    The angle between the brace and the gusset plate has been limited to 30 torecognize shear lag effects at the plate-to-beam weld.

    A stiffener plate has been added at the

    center of the gusset plate to help developthe yield line.

    Figure 6- Welded Pipe Brace-to-Beam Connection

    25-7

    Weld size required

    2003 by American Institute of Steel Construction, Inc. All rights reserved.This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    7/19

    BOLTED WIDE FLANGE BRACE-TO-WIDEFLANGE COLUMN CONNECTION (Fig. 8)

    Required Strength

    The required strength follows the same provisionsand procedures as for the pipe-to-columnconnection.

    Figure 8 - Bolted Wide Flange Brace-to-Wide Flange Column Connection

    Distribute brace force in proportion to web and flange areas

    Force in flange

    Force in web

    While the strength requirements are the same as for the welded pipe, the bolted wide flange produces much higher connection forces due to lower buckling-to-yield ratios(brace design based on buckling and connection design based on yielding).

    Brace-to-Gusset Connection

    Using the connection layout shown, the following basic LRFD requirements are checked:

    Table 3

    ItemSingle shear of braceflange bolts

    Flange plate grosssection yielding

    Flange plate net sectionrupture

    Flange plate block shear

    Bearing of bolts in braceflange

    Single shear of brace

    web boltsWeb plate gross sectionyielding

    Web plate net sectionrupture

    Web plate block shear

    Bearing of bolts in braceweb

    308

    308

    308

    308

    308

    176

    176

    176

    176

    176

    354

    405

    356

    397

    524

    265

    276

    203

    367

    239

    Note that the flange and web are sized to have aslightly higher sections than the brace flanges andweb are therefore acceptable by inspection.

    The flange plate-to-gusset weld follows the same procedures as for the pipe-to-column connection.

    Assume 15" weld along all (4) edges of the plate.

    Use 15" of " weld for the flange plate-to-gusset connection on (4) edges.

    While potentially easier to erect, the bolted connection requires a much more extensivedesign effort as well as increased fabricationcost.

    For a bolted connection such as this, the net section of the brace will by definition be theweak link in the connection. This situationoccurs because the Provisions require theremaining portions of the connection to be sized for 110% of the tensile yield of thebrace gross section.

    25-8 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    8/19

    Gusset-to-Beam Welds Gusset-to-Column Bolts

    The gusset-to-beam welds follows the same procedures as for the pipe-to-column connection.

    However, since the column is bending about itsweak axis, is taken as approximately zeroresulting in the moment and horizontal componentof the column being approximately zero. Theforces are shown on the free body diagram of thegusset plate in Fig. 9.

    Figure 9 - Gusset-to-Beam Weld Forces

    This connection has been configured for shopwelding the gusset plate to the beam and

    field bolting the beam/gusset to the column.

    For the weak axis column connection, stiffeners have been added at the top and bottom of the gusset to preclude local buckling.

    Weld of gusset to beam flange

    Use " weld for gusset to beam flange.Weld of shear tab to column

    Use " weld for shear tab to column.

    Figure 10 Gusset-to-Column Bolt Forces

    From LFRD Vol II, Table 8-19

    From table

    Use (5) 1" A490-x bolts in two verticalrows

    Gusset Plate Thickness

    The minimum thickness of the gusset plate isdetermined following the same provisions and procedures discussed earlier for the pipe-to-columnconnection.

    Table 4

    Criteria

    Tension Yielding

    Plate Buckling

    Shear Yielding @

    Fillet Welds

    Required Gusset PlateThickness (in)

    .60

    .73

    1.09

    Use gusset plate

    25-9 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    9/19

    BOLTED WIDE FLANGE BRACE-TO-BEAMCONNECTION (Fig. 11)

    Required Strength

    The required strength is the same as for the bolted

    wide flange brace-to-weak axis wide flangecolumn.

    Brace-to-Gusset Connection

    The wide flange brace-to-gusset connectionfollows the same procedures as that for the bolted wide flange brace-to-weak axis wide flangecolumn.

    Gusset-to-Beam Weld

    Figure 12 - Gusset-to-Beam Weld Forces

    The gusset-to-beam weld follows the same procedures for welded pipe brace-to-beamconnection.

    Gusset Plate Thickness

    The minimum thickness of the gusset plate followsthe same procedures as for the pipe-to-columnconnection.

    Use 1" gusset plate

    WIDE FLANGE COLUMN SPLICE (Fig. 13)

    Figure 13 - Wide Flange Column Splice

    Web Plate and Weld

    Per AISC Sec. 13.5.b: Splices shall be capable of developing nominal shear strength of smaller section.

    Figure 11 Bolted Wide Flange Brace-to-Beam Connection

    25-10 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    10/19

    Size weld of plate-to-column web using LRFDTable 8-42.

    Use fillet weld

    Design the weld plate to resist the column shear and the flange welds to resist the axial tension force.

    Load condition 4-2 becomes significant for taller, more slender frames.

    It is difficult for partial-penetration welds tocomply with the column splice requirements.

    Although base plates have not been included in this paper, there is strong analogybetween the strength and weld requirementsof column splices and base plates.

    Flange Welds

    Per AISC Sec. 8.3a.1: If partial penetration weld used, the design strength of the joints must be atleast 200 percent of the required strength per equation 4-2.

    Equation 4-2 does not include the redundancy

    factor.

    Try partial joint weld

    Since Equation 4-2 negligible, notapplicable.

    Per AISC Sec. 8.3a.2: The minimum required strength for each flange shall be 0.5 times

    Partial penetration weld

    Try complete penetration weld

    Flexural Strength Check

    Per AISC Sec. 13.5.b: Splices shall develop 50 percent of the nominal flexural strength of thesmaller section.

    Figure 14 Splice Flexural Forces

    25-11 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    11/19

    ORDINARY CONCENTRICALLYBRACED FRAME (OCBF) CONNECTIONDESIGN

    This system is the basic steel braced frame that has been a part of seismic codes for many years. Theframe is configured with welded pipe braces (seeFigure 15) for a direct comparison with the SCBFin the previous section.

    As opposed to the ductility approach for the SCBF,the design basis for the OCBF is primarily based on strength. The provisions require braces withgreater stiffness (lower kl/r ratios) and greater strength (lower system R factor and 80% reductionof design strength). In addition to theserequirements, new provisions have been added to

    preclude local buckling of the braces.

    The OCBF system also has special requirementsfor Chevron configurations. Instead of requiringincreased beam strength for unbalanced braceforces, the OCBF provisions amplify the designforces on the braces, resulting in even stronger,stiffer braces.

    The connections have slightly lower demands thanthose of SCBF's. The design force can be based onthe amplified seismic load combination if it islower than the yielding of the brace. Also, untilrecently, there were no requirements for plastichinge formation or out-of-plane yielding of theconnection. These requirements were added to thecurrent version of the Provisions. Even though therequirements are slightly less, the actualconnections will be larger in the OCBF because of the larger forces in the stronger, stiffer braces.

    Column splices must be designed for the amplifiedearthquake load combinations, but have no specialshear strength requirements. As for SCBF, theProvisions include special requirements for splicesmade with fillet welds or partial-penetration groovewelds.

    Figure 15 - OCBF Elevation

    WELDED TUBE BRACE-TO-WIDE FLANGECOLUMN CONNECTION (Fig. 16)

    Figure 16 Welded Tube Brace-to-Wide FlangeColumn Connection

    Required Strength

    The required strength of bracing connections, per AISC Sec. 14.3.a, is determined from the least of the following equations:

    Bracing member's nominal axial tensile strength:

    where equals 1.1 per AISC Sec. 6.2

    Force in the brace resulting from the followingLoad Combinations per AISC Sec. 4.1

    Eqn. (4-1)

    Eqn. (4-2)

    25-12 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    12/19

    where for OCBF per UBC Table 16-Nand does not include the redundancy factor

    The connection design for this OCBF is based on the amplified seismic forces instead of thebrace yield force.

    Maximum force, transferred to brace by systemas determined by analysis

    Brace-to-Gusset Weld

    The required weld length for the brace to the gussetfollows the same procedures as for the SCBF pipe-to-column connection.

    This connection is arranged with the braceterminating close to the beam flange, resulting in a smaller gusset plate.

    Assume 15 in of weld along (4) edges.

    Use 15in of weld on (4) edges

    Gusset-to-Beam and Column Welds

    The gusset-to-beam and column connectionsfollow the same procedures used for the SCBF

    pipe-to-column connection. However, per AISCSec. 14.3c, an additional plastic moment equal to

    will be included when the analysisindicates the brace will buckle.

    Figure 17 Gusset-to-Beam and Column Weld Forces

    Weld of gusset-to-beam flanges

    Use weld for gusset-to-beam flange

    Because the connection cannot rotate freelyout-of-plane, the new version of the Provisionsrequires the welds to be designed for anadditional force based on the plastic moment Strength of the brace. This additional requirement results in very large welds and athick gusset plate.

    Weld of gusset-to-column

    Use 1" weld for gusset-to-beam column

    Gusset Plate Thickness

    Determining the thickness of the gusset platefollows the same procedures as for the SCBF pipe-to-column connection.

    Table 5

    Criteria

    Block Shear

    Tension YieldingPlate Buckling

    Shear Yielding @Fillet Welds

    Required GussetPlate Thickness (in)

    .32 in

    .33 in

    .42 in

    1.92 in

    Use 2" gusset plate

    25-13

    2003 by American Institute of Steel Construction, Inc. All rights reserved.This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    13/19

    WELDED TUBE BRACE-TO-BEAMCONNECTION (Fig. 18)

    Required Strength

    The required strength is the same as for the tube-to-

    column connection.Brace-to-Gusset Weld

    The brace-to-gusset weld is the same as for thetube-to-column connection.

    Gusset-to-Beam Connection

    The gusset-to-beam connection follows the same procedures for the SCBF pipe-to-columnconnection. Also included is the additional plasticmoment as discussed in the previous section.

    Gusset Plate Thickness

    The gusset plate thickness follows the same procedures as for the SCBF pipe-to-columnconnection.

    use 1" gusset plate

    Figure 19 Gusset-to-Beam Connection

    Figure 18 Welded Tube Brace-to-Beam Connection

    25-14 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    14/19

    ECCENTRICALLY BRACED FRAME(EBF) CONNECTION DESIGN

    The EBF system was introduced into the buildingcodes in the late 1980's and has received moderateuse in steel braced frame buildings since. Theframe in this example uses welded tubeconnections similar to the OCBF (see Figure 20 for a frame elevation).

    As for the SCBF and OCBF examples, a Chevronconfiguration with the links in the center wasselected. The building codes currently also allowlinks to be placed adjacent to columns. For thatconfiguration, the connection design criteriacurrently being developed for welded steel momentframe connections needs to be considered inaddition to the topics presented in this paper.

    The ductility in the EBF system comes from therotation and yielding of the link. The link in thisexample was configured for shear yielding (shortlink) rather than for flexural yielding (long link).

    The EBF provisions are based on a capacity designapproach and therefore all members and connections must be stronger than the link. The

    brace design is based on buckling strength under the strain hardened link force. The required strength of the connection then needs to exceed theexpected strength of the brace in compression.

    Additional connection issues with the EBF areassociated with the design and detailing of the link.To assure stable yielding, web stiffeners are

    required at each end of the link and also atintermediate locations. In general, closer stiffener spacing is required for shear links than for flexurallinks. The Provisions do not allow web doubler

    plates or brace gusset plates extending into the link region. Finally, the Provisions require the flangesof the link to be braced out-of-plane.

    Column splices must be designed for the amplified earthquake load combinations, but have no specialshear strength requirements. As for SCBF, theProvisions include special requirements for splicesmade with fillet welds or partial-penetration groovewelds.

    Figure 20 EBF Elevation

    WELDED TUBE BRACE-TO-WIDE FLANGECOLUMN CONNECTION (Fig. 21)

    Figure 21 Welded Tube Brace-to-Wide FlangeColumn Connection

    Required Strength

    The required strength of brace, per AISC Sec 15.6ais determined from the resulting forces generated

    by the expected nominal shear strength of the link increased by 125% to account for strain

    hardening.

    Next, per AISC Sec. 15.6d, the required strength of the connection shall be at least the expected nominal strength of the brace. For the TS 8 x 8 x

    25-15 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    15/19

    The required connection strength of the EBF is the lowest of the various frames shown inthis paper. The reason for this lower demand is that the EBF has the largest system R factor and that the connection force is based onbrace compression strength rather than brace

    yielding.

    Brace-to-Gusset Weld

    The required weld thickness for the brace to thegusset follows the same procedures as for theSCBF pipe-to-column connection.

    Assuming 14" of weld along (4) edges

    Use 14" of weld along (4) edges

    Gusset-to-Beam and Column Welds

    Figure 22 - Free Body Diagram of Brace to Beam/Column Connection

    Uniform Force Method as recommended per LRFDVol. II Part 11, the axial force from the brace isresolved into the corresponding moment,horizontal, and vertical forces on the gusset plate.This is shown on the free body diagram of thegusset plate Fig. 22.

    Weld of gusset-to-beam flanges

    Resultant

    Use fillet weld for gusset-to-beam flange

    Weld of gusset to column

    Use weld (similar to weld along beam) for gusset to column

    As for the OCBF, the brace extends to thebeam flange to minimize the size of the

    gusset plate.

    Gusset Plate Thickness

    Table 6

    Criteria

    Block Shear

    Tension Yielding

    Plate Buckling

    Shear Yielding @Fillet Welds

    Required Gusset PlateThickness (in)

    .33 in

    .21 in

    .31 in

    .55in

    Use gusset plate

    25-16 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    16/19

    WELDED TUBE BRACE-TO-BEAMCONNECTION (Fig. 23)

    Required Strength

    The required strength is the same as the EBFwelded tube brace-to-wide flange columnconnection.

    Brace-to-Gusset Weld

    The required weld length for the brace to the gussetis the same as the EBF welded tube brace-to-wideflange column connection.

    Figure 24 Free Body Diagram of Brace-to-Beam/Column Connection

    Elastic Vector Method

    Choose weld

    Since the gusset plate cannot extend into thelink region, a stiffener is added at the end of the link to balance the loading on the welds.

    Gusset Plate Thickness

    Table 7

    Criteria

    Block Shear

    Tension Yielding

    Plate Buckling

    Shear Yielding @Fillet Welds

    Required Gusset PlateThickness (in)

    .33 in

    .29 in

    .31 in

    .63 in

    Use gusset plate

    Figure 23 Welded Tube Brace-to-Beam Connection

    25-17 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    17/19

    BEAM LINK (Fig. 23) Link Stiffener Welds

    Per AISC Sec 15.3c, fillet welds connecting link stiffeners shall have a design strength:

    is area of stiffener) for connectionof web to stiffener.

    for connection of flange to stiffener.

    Weld For Web

    Choose a weld

    Weld for Flange

    Choose a weld

    Lateral support of link

    Per AISC Sec 15.5, lateral support is to be provided at both the top and bottom of the link

    flanges at each end.

    End Link Stiffeners

    Per AISC Sec. 15.3a, provide full depth webstiffeners on both sides of link at end of braces:

    Width Thickness or 3/8" whichever is greater

    (2) sided, full beam width & depth

    Use plate thick

    Link stiffener requirements are prescriptive.

    Intermediate Link Stiffeners

    Per AISC Sec. 15.3b:

    1.) Provide intermediate web stiffenersspaced at; since link length

    and link rotation

    2.) - Intermediate link web stiffeners shall befull depth.

    -If link depth

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    18/19

    Design support for 6% of flange strength

    Lateral support of beam links @ ends of W18x40

    Choose 3 x 3 x

    The composite metal deck and concrete slab provide lateral support of the top flange.

    BEAM-TO-COLUMN CONNECTIONS

    Figure 26 - Beam-to-Column Connections

    Required Strength

    Per AISC Sec. 15.7, these connections shall have

    the strength to resist (2) equal and opposite forcesequal to 2% of flange capacity - actinglaterally on the beam flanges.

    The Provisions require nominal torsional restraint of the beam away from the link.This requirement is met by adding stiffener

    plates to a typical bolted shear connection.

    Plates and WeldsWeld at Column:

    Choose a weld

    Weld at Beam

    Choose a weld with a plate " x 4" x 4"

    WIDE FLANGE COLUMN SPLICE @ EBF

    Figure 27 EBF Column Splice

    The column splice for the EBF is essentiallythe same as for the OCBF.

    Required Strength

    Per AISC Sec 8.3 the design strength of columnsplices shall meet or exceed the required strengthof Sec. 8.2:

    Eqn. 4-1

    Eqn. 4-2

    But need not exceed:

    a. the maximum load transferred to thecolumn considering times thenominal strength of the member

    b. limit as determined form the resistance of the foundation to overturning uplift

    For this splice, Eqn 4-2 governs

    However, for EBF also check axial tensionwhen nominal shear strength of links reached,

    25-19 2003 by American Institute of Steel Construction, Inc. All rights reserved.

    This publication or any part thereof must not be reproduced in any form without permission of the publisher.

  • 7/26/2019 Design and Detailing of Seismic Connections for Braced Frame Structures[1]

    19/19

    Flange Welds

    Per AISC Sec. 8.3a and 8.3b:

    Column splices made with fillet and partial joint penetration groove welds shall not be located within 4' nor half the column clear height of beam

    to column connections, whichever is less.If subjected to a tensile stress per load combination4-2 filler metal shall meet requirements of CVNtoughness as required by Sec. 7.3b, and

    1.) The design strength of partial joint penetration welds shall be at least equal to200% of required strength.

    2.) The minimum required strength for eachflange shall be

    Beveled transitions are not required when changesin thickness and width of flanges and web occur.

    Initially try a partial penetration groove weld thatwill be at least equal to 200% of the required strength.

    Use a complete penetration weld at each flange,this will satisfy strength requirements of Sec 8.2and Sec. 8.3a.

    Locate splice @ 4' from floor or 14/2 - 7/2 = 3'-6";4' from floor governs

    *provide shear plate to web for erection

    CONCLUSION

    Properly designed and detailed connections arecritical to achieve the expected performance of

    braced frames in earthquakes. As can be seen inthe design examples, there are numerous buildingcode provisions that address connection design.These provisions have evolved over the years asnew braced frame systems have been introduced and as more experience has been gained from the

    behavior of buildings in actual earthquakes.

    ACKNOWLEDGEMENTS

    The author wishes to acknowledge the considerableeffort s of Garo Pehlivanian, Kristie Fromhold,Steve Curran and Michael Townsend in assisting inthe development of this paper.