Deliverable 3.1 – Memo on Instrumentation Completion

12
Deliverable 3.1 – Memo on Instrumentation Completion From IAA: Deliverable 3.1: A memo demonstrating with photos the completed instrumentation of sixteen bioretention cells at the study site. Appendices will include receipts for the soil moisture sensors and other low value incidental equipment to complete instrumentation of the bioretention cells. $ 10,400 Target Date: July 31, 2019 This memo is written to fulfill Deliverable 3.1 stating that instrumentation need to carry out the project titled The effects of mulch on stormwater treatment and maintenance effort in bioretention systems. Soil Moisture Sensors (charged to this project) Sixteen bioretention cells have been instrumented with 2 soil moisture sensors apiece, one close to the cell inlet, the other by the outlet. Each soil moisture sensors connects wirelessly to a datalogger that then sends data at 30-minute intervals to cloud-server where data can be viewed and downloaded. Figure 1: Image shows layout of 16 bioretention cells

Transcript of Deliverable 3.1 – Memo on Instrumentation Completion

Page 1: Deliverable 3.1 – Memo on Instrumentation Completion

Deliverable 3.1 – Memo on Instrumentation Completion

From IAA: Deliverable 3.1: A memo demonstrating with photos the completed instrumentation of sixteen bioretention cells at the study site. Appendices will include receipts for the soil moisture sensors and other low value incidental equipment to complete instrumentation of the bioretention cells.

$ 10,400 Target Date: July 31, 2019

This memo is written to fulfill Deliverable 3.1 stating that instrumentation need to carry out the project titled The effects of mulch on stormwater treatment and maintenance effort in bioretention systems.

Soil Moisture Sensors (charged to this project)

Sixteen bioretention cells have been instrumented with 2 soil moisture sensors apiece, one close to the cell inlet, the other by the outlet. Each soil moisture sensors connects wirelessly to a datalogger that then sends data at 30-minute intervals to cloud-server where data can be viewed and downloaded.

Figure 1: Image shows layout of 16 bioretention cells

Page 2: Deliverable 3.1 – Memo on Instrumentation Completion

Figure 2: Image shows the two soil moisture sensors in each cell, one at inflow and one at outflow

Figure 3: Soil moisture sensors at inflow and outflow installed at 12 inches below the surface. The white mote transmits sensor data to a central datalogger (not shown) wirelessly

Page 3: Deliverable 3.1 – Memo on Instrumentation Completion

Figure 4: Soil moisture sensor data viewed on a cloud server allowing remote access

Page 4: Deliverable 3.1 – Memo on Instrumentation Completion

Cistern Pressure Transducer (charged to this project)

A replacement pressure transducer was purchased and installed in our stormwater collection cistern. The pressure transducer will enable us to determine water levels in the cistern, and thereby enable determination of outflow flow rates from the cistern to the bioretention cells. Stormwater collected in this cistern will be dosed and distributed to all 16 bioretention cells.

Figure 5: Pressure transducer installed to record water level in the main stormwater cistern. Water level in the cistern enables the determination of outflow from the cistern to the bioretention cells.

Page 5: Deliverable 3.1 – Memo on Instrumentation Completion

Outflow flow meters (not charged to this project)

Outflow from each of the 16 bioretention cells and one direct outflow from the cistern are plumbed to 17 flow meters. During sampling events, each one of these 17 set ups will be associated with an automatic water sampler that will collect flow-paced water quality samples.

Figure 6: Flow meters to measure outflow from the 16 bioretention cells and direct outflow from the cistern

Page 6: Deliverable 3.1 – Memo on Instrumentation Completion

Figure 7: Outflow flow meter and sampling port configuration

Page 7: Deliverable 3.1 – Memo on Instrumentation Completion

Appendix A – Receipts for Soil Moisture Sensors and Pressure Transducer

Page 8: Deliverable 3.1 – Memo on Instrumentation Completion
Page 9: Deliverable 3.1 – Memo on Instrumentation Completion
Page 10: Deliverable 3.1 – Memo on Instrumentation Completion
Page 11: Deliverable 3.1 – Memo on Instrumentation Completion
Page 12: Deliverable 3.1 – Memo on Instrumentation Completion

Campbell Scientific Inc815 West 1800 North • Logan, Utah 84321-1784

Phone 435.227.9092 • Fax 435.227.9091Fed. I.D. #87-0305157 • DUNS#06-798-0730

P.O. NumberInvoice NumberShipment NumberInvoice / Ship DateDue DateCustomer Number

Page

Invoice

BILL

TO

SHIP

TO

Buyer Contact Payment TermsPhone Ship ViaEmail Freight Terms

User Name Incoterms

Li Model Part/UID Description CO Qty UM Unit Price Ext. Price

Total

Terms and conditions with Campbell Scientific Inc. are governed by the terms found at http://www.campbellsci.com/terms.Banking details will never be done via unsolicited email.

Jayakaran262119347518-114 Oct 201914 Oct 2019536361

Anand Jayakaran Anand JayakaranWashington State University Washington State UniversityFrench 220 2606 W Pioneer AvePO Box 641020 WSU PuyallupPullman, WA 99164 Puyallup, WA 98371-4998

Anand Jayakaran CRDT_CRD253-445-4523 FEDEX [email protected] PP&AAnand Jayakaran FOB Logan, UT

1 CS451-30-H 28790-11 Pressure Transducer SDI-1 US 1 EA 956.00 956.00A-7-WN 14

Subtotal 956.00Sales Tax 95.86Freight 12.31

1,064.17

PAID IN FULL