AREA DESIGNACION hw tw bf tf Peso lx Sx rx Zx ly Sy ry Zy J Cw mm mm mm mm cm2 Kg/m cm4 cm3 cm cm3 cm4 cm3 cm cm3 cm4 x 106 cm6 I-COL 200 X 21.7 200 5.5 100 8.0 27.16 21.7 1.840 184.00 8.24 200.15 134.00 26,800 2.22 41.39 4.43 12,349 I-COL 248 X 25.8 248 5.0 124 8.0 32.68 25.8 3.540 285.48 10.40 305.36 255.00 41,129 2.79 62.95 5.20 36,720 I-COL 298 X 32.6 298 5.5 149 8.0 40.80 32.6 6.320 424.16 12.40 455.03 442.00 59,329 3.29 90.94 6.65 92,931 I-COL 300 X 37.3 300 6.5 150 9.0 46.78 37.3 7.210 480.67 12.40 522.08 508.00 67,733 3.29 104.23 9.87 107,545 I-COL 350 X 50 350 7.0 175 11.0 63.14 50.0 13.600 777.14 14.70 840.85 984.00 112,457 3.95 172.46 19.28 282,706 I-COL 400 X 66 400 8.0 200 13.0 84.12 66.0 23.700 1,185,00 16.80 1,285,95 1,740,00 174,000 4.54 265.98 35.68 651,495 I-COL 450 X 76.5 450 9.0 200 14.0 96.76 76.5 33.500 1,488,89 18.60 1,621,49 1,870,00 187,000 4.40 288.55 46.84 888,699 I-COL 200 X 50.50 200 8.0 200 12.0 63.53 50.5 4.720 472.00 8.62 513.15 1,600,00 160,000 5.02 242.82 26.04 141,376 I-COL 250 X 72.4 250 9.0 250 14.0 92.18 72.4 10.800 864.00 10.80 936.89 3,650,00 292,000 6.29 442.00 51.13 508,226 I-COL 300 X 94.5 300 10.0 300 15.0 110.80 94.5 18.800 1,253,33 13.00 1,464,75 6,240,00 416,000 7.51 681.75 76.50 1,267,110 LOS PERFILES LAMINADOS COLMENA CUMPLEN CON LA NORMA ASTM A-36 ESFUERZO DE FLUENCIA Fy=2530 Kg/cm2 (36,000 PSI) (253 Mpa) Fu=4000 Kg/cm2 (56,000 PSI) (400 Mpa) ELONGACION 23% EN 2" PERFILES LAMINADOS TIPO I Y H COLMENA ALMA ALETAS SECCION TOTAL TORSION

description

por precios mas economia para dar mas de

Transcript of dedde

AREA

DESIGNACION hw tw bf tf Peso lx Sx rx Zx ly Sy ry Zy J Cw

mm mm mm mm cm2 Kg/m cm4 cm3 cm cm3 cm4 cm3 cm cm3 cm4 x 106 cm6

I-COL 200 X 21.7 200 5.5 100 8.0 27.16 21.7 1.840 184.00 8.24 200.15 134.00 26,800 2.22 41.39 4.43 12,349

I-COL 248 X 25.8 248 5.0 124 8.0 32.68 25.8 3.540 285.48 10.40 305.36 255.00 41,129 2.79 62.95 5.20 36,720

I-COL 298 X 32.6 298 5.5 149 8.0 40.80 32.6 6.320 424.16 12.40 455.03 442.00 59,329 3.29 90.94 6.65 92,931

I-COL 300 X 37.3 300 6.5 150 9.0 46.78 37.3 7.210 480.67 12.40 522.08 508.00 67,733 3.29 104.23 9.87 107,545

I-COL 350 X 50 350 7.0 175 11.0 63.14 50.0 13.600 777.14 14.70 840.85 984.00 112,457 3.95 172.46 19.28 282,706

I-COL 400 X 66 400 8.0 200 13.0 84.12 66.0 23.700 1,185,00 16.80 1,285,95 1,740,00 174,000 4.54 265.98 35.68 651,495

I-COL 450 X 76.5 450 9.0 200 14.0 96.76 76.5 33.500 1,488,89 18.60 1,621,49 1,870,00 187,000 4.40 288.55 46.84 888,699

I-COL 200 X 50.50 200 8.0 200 12.0 63.53 50.5 4.720 472.00 8.62 513.15 1,600,00 160,000 5.02 242.82 26.04 141,376

I-COL 250 X 72.4 250 9.0 250 14.0 92.18 72.4 10.800 864.00 10.80 936.89 3,650,00 292,000 6.29 442.00 51.13 508,226

I-COL 300 X 94.5 300 10.0 300 15.0 110.80 94.5 18.800 1,253,33 13.00 1,464,75 6,240,00 416,000 7.51 681.75 76.50 1,267,110

LOS PERFILES LAMINADOS COLMENA CUMPLEN CON LA NORMA ASTM A-36

ESFUERZO DE FLUENCIA Fy=2530 Kg/cm2 (36,000 PSI) (253 Mpa)

Fu=4000 Kg/cm2 (56,000 PSI) (400 Mpa)

ELONGACION 23% EN 2"

PERFILES LAMINADOS TIPO I Y H COLMENA

ALMA ALETAS SECCION TOTAL TORSION