DCCK 18 M 10/10 AIK - di-soric.com fileDCCK 18 M 10/10 AIK Inductive Proximity Switch di-soric GmbH...

1
200483 © di-soric | Subject to modifications | 09/09/19 | Page 1 (1) DCCK 18 M 10/10 AIK Inductive Proximity Switch di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com TECHNICAL INFORMATION (typ.) +20°C, 24V DC Operating principle Inductive Evaluation analog Size M18 x 1 (thread) Design screw Mounting quasi-flush Characteristics extremely high operating distance Operating distance 0 … 10 mm Standardized measuring plate 30 x 30 x 1 mm Service voltage 15 ... 30 V DC No-load current < 12 mA Analog output 0 ... 10 V, 4 ... 20 mA Switching frequency 500 Hz Reproducibility ± 0,02 mm (TA = constant) / 0,3 mm (23°C ± 5°C) Ambient temperature, operation -25 … +70 °C Insulation voltage endurance 500 V Protection class IP 67 Casing material brass nickel plated Material PUR (Cable) Connection Cable, 2,0 m BN = brown BK = black BU = blue WH = white mA V 3 2 4 1 BN BK WH BU Safety instructions The Instruments are not to be used for safety applications, in particular applications in which safety of persons depends on proper operation of the instruments. These instruments shall exclusively be used by qualified personnel. Analog voltage output Analog currant output Cable, highly flexible Integrated amplifier Short-circuit protection

Transcript of DCCK 18 M 10/10 AIK - di-soric.com fileDCCK 18 M 10/10 AIK Inductive Proximity Switch di-soric GmbH...

200483

© di-soric | Subject to modifications | 09/09/19 | Page 1 (1)

DCCK 18 M 10/10 AIK

Inductive Proximity Switch

di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach

Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com

TECHNICAL INFORMATION (typ.) +20°C, 24V DC

Operating principle   Inductive

Evaluation   analog

Size   M18 x 1 (thread)

Design   screw

Mounting   quasi-flush

Characteristics   extremely high operating distance

Operating distance   0 … 10 mm

Standardized measuring plate   30 x 30 x 1 mm

Service voltage   15 ... 30 V DC

No-load current   < 12 mA

Analog output   0 ... 10 V, 4 ... 20 mA

Switching frequency   500 Hz

Reproducibility   ± 0,02 mm (TA = constant) / 0,3 mm (23°C ± 5°C)

Ambient temperature, operation   -25 … +70 °C

Insulation voltage endurance   500 V

Protection class   IP 67

Casing material   brass nickel plated

Material   PUR (Cable)

Connection   Cable, 2,0 m

BN = brown

BK = black

BU = blue

WH = white

mA

V

3

2

4

1BN

BK

WH

BU

Safety instructionsThe Instruments are not to be used for safety applications, in particularapplications in which safety of persons depends on proper operation of theinstruments.These instruments shall exclusively be used by qualified personnel.

Analog voltage output

Analog currant output

Cable, highly flexible

Integrated amplifier