dc-services LIFT SOLUTIONS
Transcript of dc-services LIFT SOLUTIONS
![Page 1: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/1.jpg)
STANDARD
SOLUTIONSLIFT
![Page 2: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/2.jpg)
4
Μicroprocesor system for lift control
MAIN FEATURES/1• Up to 40 stops, each stop determinated as A or B side.• Up to 8 lifts in multiplex work.• CAN communication between modules.• Small dimensions.• Central procesor unit (CPU) width 72 mm. • Control panel width 120 mm for roomless lift.• Landing modules with integrated arrows and dot matrix display width 42 mm suitable for new instalation and
modernization, fi xed on landing plate with can / power connector for next stop without additional box in shaft.• Landing modules for landing calls connection and diff erent displays with diff erent protocols (for example
TFT,LCD,...) • LCD module for monitoring, adjustment and transfer parameters in LC100-C, adjust VVVF, load mesurement
device, connectable on any module in system (control panel, module on the top of car, displays, any landing modules).
• One travelling cable (18 + 2x2x0.5) with connectors on both sides.• All equipments in control panel, on cabine, in shaft, car operating panel, landing operating panels are plugable
with connectors PLUG & PLAY system.• Teleservis through internet from any point in the world with monitoring, adjusting and analyzing all I/O, calls,
parameters, statistic, errors and warnings.
MAIN FEATURES / 2• Software in all modules for all application is same. Diff erences in applications have to select only by parameters
in CPU and by address on landing modules.• Multiplex system without any necessary additional module.• All inputs have galvanic isolation, and they are equipt by LED diode.• All inputs / outputs on all modules are programable with user defi ned function and polarity. All input and
output are predefi ned for all aplication.• All landing modules are also displays or interface for displays.• Programabile marking for each stop on all type of displays without programing any display / landing module.
Programabile marking by parameters on CPU.• Delay for stopping are programable for each stop and direction.• More than 100 programable diff erent timers.• 256 last error and warning in real time with additional description (stop, drection of travel, state of door, etc.)• Daily, monthly, yearly and user defi ned travel counters • Integrated software for rescue system by standard UPS.• All display units in red and blue colors. Other colors on request.• Monitoring system via internet, ethernet, gsm modem.
LC100SYSTEM
![Page 3: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/3.jpg)
5
![Page 4: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/4.jpg)
6
CABLELC100MRL 120
LC100SYSTEM
![Page 5: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/5.jpg)
7
LC100MRL400
LC100MRL650
LC100SYSTEM
![Page 6: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/6.jpg)
8
LC100SYSTEM
![Page 7: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/7.jpg)
9
LC100SYSTEM
![Page 8: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/8.jpg)
L-1 L-2 L-3 (standard)
10
L-D
C. O. P.
![Page 9: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/9.jpg)
SP-1 TFT Display.SP-2 DOT MATRIX Display.
P-4
P-1
P-5
P-2
SP-1 (standard)
SP-2
P-6
P-3
P-7
11
L. O. P.
![Page 10: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/10.jpg)
12
M6-R
M5-R
M7-R
M8-R
TFT-LTFT-M
M8-B M8-W
M7-B M7-W
M6-B
M5-B
M6-W
M5-W
DOT
TFT
2 x 7 SEGMENT
DOTMATRIX
![Page 11: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/11.jpg)
13
LC100-C
LC100-K
LC100-Z
LC100-S
LC100MODULE
![Page 12: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/12.jpg)
14
LC100-H
LC100-J
LC100-F
LC100-E2
LC100-RLC100-T
LC100MODULE
![Page 13: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/13.jpg)
15
LC100-PL
LC100-K2
LC100-VFD
LC100-SR
LC100MODULE
![Page 14: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/14.jpg)
16
LC100-A
LC100-LLLC100-V
LC100-W2LC100-Y
LC100-V2LC100-I
LC100MODULE
![Page 15: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/15.jpg)
17
LC100-G
LC100-B
LC100-D LC100 Monitoringsystem
LC100MODULE
![Page 16: dc-services LIFT SOLUTIONS](https://reader034.fdocuments.net/reader034/viewer/2022052313/587bc9d71a28ab6c3c8b6777/html5/thumbnails/16.jpg)
22 N. Plastira str. Sykies Thessaloniki GreeceTel. 0030 2314 31 91 93, 0030 2310 62 82 70
www.dc-services.gr • [email protected] • [email protected]