DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN...
Transcript of DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN...
![Page 1: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/1.jpg)
DBP AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN
CARLISLE BOROUGH
Jamie R. Shambaugh, P.E. - GFMichael J. Mehaffey, P.E. – GF
Peter S. Selan – Borough of Carlisle
![Page 2: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/2.jpg)
• Project Background and Objectives• DBP Formation and Control Theory• DBP Control Study Summary
– Alternatives Evaluation– Recommendations
• Project Design Collaboration• Construction• Operation and Results• Questions and Comments
Outline
![Page 3: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/3.jpg)
Project Background
SOURCE: MAPQUEST
![Page 4: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/4.jpg)
• Borough of Carlisle water system supplies:– Borough and neighboring bulk water customers– Serves approximately 20,000 people
• WTP permitted capacity of 7 mgd– Conventional process with granular media filtration
• Source of supply - Conodoguinet Creek• Borough and Staff place a high priority on water quality and
quality of service• 1st in PA to achieve Partnership for Safe Water Phase IV
Project Background
![Page 5: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/5.jpg)
Project Location – Demonstrates Root Cause
![Page 6: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/6.jpg)
WTP
WEST END TANK
![Page 7: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/7.jpg)
• Staff identified water quality concerns in the system’s West End• West End is relatively new – sized for demands
– Primarily warehouse development• TTHM concentrations very elevated in West End• Booster chlorination required to maintain residuals• Mixing required to eliminate stratification• TTHM concentrations and chlorine residuals are very good in
remainder of system• Stage 1 DBPR compliance (RAA) not a problem• Stage 2 DBPR projected to be not in compliance
Project Background
![Page 8: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/8.jpg)
• Prior to this project Staff tried to reduce DBP concentrations:– Valve position and distribution modifications– Performed a tracer test– Considered pumping from tank to reduce water age
Project Background
![Page 9: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/9.jpg)
Stage 1 TTHM Data
West End/CSC
![Page 10: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/10.jpg)
TTHM LRAA (Stage 1 DBPR Data)
![Page 11: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/11.jpg)
Stage 1 HAA Data
West End/CSC
![Page 12: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/12.jpg)
HAA LRAA (Stage 1 DBPR Data)
![Page 13: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/13.jpg)
Borough’s Fluoride Tracer Test Tells the Story
![Page 14: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/14.jpg)
West End Piping Schematic
WTP
T
T
T
16”16”
12”*
16”
![Page 15: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/15.jpg)
DBP Formation and Control Theory
![Page 16: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/16.jpg)
DBP Formation and Control Theory
![Page 17: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/17.jpg)
Proven Approach – Storage Tank Aeration
![Page 18: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/18.jpg)
Well-Designed Storage TankAeration Can Provide TTHM Compliance
![Page 19: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/19.jpg)
Approach – Modification of System Operations
DBP Control via Tank Operating Changes, Aeration
Water Age >> 16 days (Fluoride Tracer)Estimated Water Age ~ 32 days
TTHM = 140 - 170 ppbHAA = 80 – 95 ppb
Projected Water Age Following Operational Changes ~ 7 days
TTHM < 60 ppbHAA < 50 ppb
![Page 20: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/20.jpg)
• West End Tank– 2.3 Mgal Standpipe– Height to Overflow = 133 feet
• Floating Storage with Fill/Drain Controlled by WTP– Refill initiated when water level reached 123 feet– Cycle occurs approx. two (2) times per day– Daily tank turnover approximately 15% (theoretical)– Water age much greater – Ref. Fluoride Tracer
• Existing pumped recirculation system for mixing• Booster chlorination required at tank• Water age and booster chlorine = Elevated DBPs
DBP Control Study - Summary
![Page 21: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/21.jpg)
• WTP– Phase IV Partnership– Low TOC Effluent– Minimal Opportunity to Reduce NOM Cost-Effectively
• Borough Very Reluctant to Chloraminate• DBP and Chlorine Residual Issues – Localized to West End Area• DBP issues are direct result of excessive water age• Borough Staff Prefer a Localized Approach to Address Distribution
System Water Quality
DBP Control Study - Summary
![Page 22: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/22.jpg)
• TTHM compliance is primary driver• HAA compliance is also an issue• The Borough needs to reduce both TTHM and HAA concentrations
in the West End for long-term compliance with the Stage 2 DBPR
DBP Control Study - Summary
![Page 23: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/23.jpg)
• Storage Tank Aeration• Tank Operation Modifications• Transmission/Distribution System Modifications• Alternative Disinfectants• Biologically Active Carbon/Other Treatment
DBP Control Study – Alternatives Evaluation
![Page 24: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/24.jpg)
• Storage Tank Aeration– Proven approach for TTHM reduction– Can be designed for required % removal– Will NOT address HAA concerns– Will NOT address water age root cause– Will NOT address chlorine residual – booster chlorine required &
HAA formation will continue• Transmission/Distribution System Modifications
– No opportunity for looping– Can induce additional flow by CSC site but will not address root
cause
DBP Control Study – Alternatives Evaluation
![Page 25: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/25.jpg)
• Tank Operation Modifications (Pumped Storage)– Longer draw cycles– Allow discharged water to be used– Limit the volume used, if necessary– Can reduce water age to 7 days or less
• Alternative Disinfectants– Viable alternative– Last alternative based on Borough preference
• Biologically Active Carbon/Other Treatment– Effective for HAA reduction– Not effective for TTHM reduction
DBP Control Study – Alternatives Evaluation
![Page 26: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/26.jpg)
• Minor valve position modifications• Convert West End Tank to Pumped Storage – Reduce Water Age• Storage Tank Aeration – If Necessary
Recommended Approach: Phases/Multi-Faceted
![Page 27: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/27.jpg)
• Reduction in available fire flow– Flow testing with tank online and offline– Fire flow >2,500 gpm with tank offline– Lag pump activates at low pressure
• Reduction in stored volume– Existing effective volume only 175,000 gallons of 2.33 Mgal– Increases useable volume to 1.8 Mgal– Maintains minimum 175,000 gallons available at all times
• Loss of Utility Power
Pumped Storage Concerns
![Page 28: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/28.jpg)
• Maintain pumped recirculation/mixing capability– 260 gpm at 30’ TDH, 3 hp
• Reuse chlorine analyzer, etc. as possible• Provide space for future hypo system, if necessary• Replace fiberglass structure with precast concrete• Two (2) booster pumps
– 400 – 500 gpm at 120’ TDH, 20 hp• Spray aeration system (bid alternate)
– 15 hp spray aerator with 2 hp ventilation blower• Motor operated refill and flow control valve
Design Criteria
![Page 29: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/29.jpg)
• High level start (adjustable)• Pump maintains preset discharge pressure• Lag pump starts if minimum pressure not achieved• Low level pump stop (adjustable)• Delay following pump down (adjustable)
– Allow pumped water to be used• Refill at a controlled rate (adjustable)• Pumping operations initiated upon completion of fill to high level
setpoint
BPS Control and Operation
![Page 30: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/30.jpg)
West End Tank Pumped Storage Operation
Pump Start Level
Pump Stop & Hold Level
EmergencyStorage
OperatingVolume
![Page 31: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/31.jpg)
![Page 32: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/32.jpg)
West End Tank Project – Site Plan
![Page 33: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/33.jpg)
![Page 34: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/34.jpg)
West End Tank and BPS
![Page 35: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/35.jpg)
![Page 36: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/36.jpg)
Lower Plan – Existing Altitude Valve Vault
![Page 37: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/37.jpg)
Valve/Piping Vault
![Page 38: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/38.jpg)
Main Control Panel
![Page 39: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/39.jpg)
![Page 40: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/40.jpg)
![Page 41: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/41.jpg)
• Operation• Emergency/Fireflow• Power Loss
– Generator Capable– Return to Floating Storage with Emergency Power at WTP
Normal Operating Approach
![Page 42: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/42.jpg)
Performance – TTHM Reduction
![Page 43: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/43.jpg)
Performance – HAA Reduction
![Page 44: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/44.jpg)
• Effective water age control– DBP Compliance– Chlorine Residual Maintenance
• Effective collaboration– Successful Project
Conclusions
![Page 45: DBP AND DISTRIBUTION SYSTEM CHLORINE … AND DISTRIBUTION SYSTEM CHLORINE RESIDUAL CONTROL IN CARLISLE BOROUGH Jamie R. Shambaugh, P.E. - GF Michael J. Mehaffey, P.E. – GF Peter](https://reader031.fdocuments.net/reader031/viewer/2022022514/5af18c927f8b9aa9168f37ac/html5/thumbnails/45.jpg)
• WTP Optimization (TOC, chlorination point)• Disinfection Modification (i.e. modified pre-conceived ideas
related to WTP process recycle)• Disinfectant Type - chloramines• Tank Aeration• System Operation and Tank Operation Modifications
Select the Right Approach for DBP & Chlorine Control