Agenda

• Why EarthDirEX?• Challenges• Ground loops• Features• Charging

Page 4: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Why EarthDirEX?

• No outdoor unit• 30% Tax Credit (until Dec. 31, 2016) • Stable sub-surface temperature• Less maintenance

• No pump, no glycol and no outdoor coil, no fan motor

• Lower operating cost and installed cost• 60% Less drilling = lower cost boreholes

• Direct exchange ~80’/ton • Water source ~200’/ton

Page 5: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Definition - Challenges

• Direct Exchange -There’s no water, no pump, no refrigerant to water heat exchanger. All these items do is reduce system efficiency.

• Heat exchanger is in direct contact with the Earth. • But copper will corrode in the ground!• Less than 1% of the ground is corrosive to copper• Its illegal to bury refrigerant tubing!

• DOE/EPA approved direct exchange

Page 6: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

EPA Letter

Page 7: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Earth Loop Sizing

• Two ways to size Earth Loop• use the climate zone map• use the formula below

• Cooling load ÷ heating load =• less than 1, then use 65' per ton• between 1 and 1.75, then use 80' per ton• greater than 1.75, then use 100' per ton

Page 8: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Sizing is 65, 80 or 100 feet per ton depending on the climate zone

65 ft/ton

80 ft/ton

100 ft/ton

Page 9: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Sizing Earth loops

ft/ton 65 80 100 65 80 1002 130 160 200 2 130 165 2003 195 240 300 3 200 250 3254 260 320 400 4 280 325 4005 325 400 500 5 325 400 2/250

12 possible 7 unique to build

Page 10: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Earth Loops

Page 11: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Earth Loops

Page 12: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Earth Loop

Page 13: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Some Earth Loop Details

• Watch out for corrosive ground • Stay away from a ph below 5.5 or over 11

• All liquid lines are ½ inch • Encased in a 1 inch plastic pipe• A vacuum must be pulled before backfilling

• 2 vapor lines are used in the Earth loop • Coming out of the Earth loop is one vapor line

• Up to 250 foot loops are ¾ inch vapor line• Over 250 foot loops are 7/8 inch vapor line

Page 14: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

More Earth Loop Details

• The liquid line and the vapor line from the Earth loop to the compressor unit should be buried the deeper of 1.5 feet or below the maximum frost line

• Must insulate both lines from the top of the Earth loop to the compressor section with heavy duty ¾ inch closed cell insulation, capable of withstand 220°f degree

Page 15: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Features

• One bi-directional EXV in compressor section

• Interface control board• Oil separator• Accumulator with sight glass & float

ball for charging• Earth loop seal valve

Page 16: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Efficiency and capacities

Cooling Capacity EER

Heating Capacity COP

2 ton 29400 23.8 21000 4.2

3 ton 42000 21.3 35200 4.1

4 ton 57000 20.1 46500 4.2

5 ton 71000 19.3 58000 3.9

Page 17: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Match ups

Compressor Section

Air Handler

Y1SA-024 B6EMMN036K-B

Y1SA-036 B6EMMN036K-B

Y1SA-048 B6EMMN060K-C

Y1SA-060 B6EMMN060K-C

Page 18: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Refrigerant Charging

Start In Heating Mode & Charge To Sight Glass• let system operate 15 min• check sight glass, add R410A• when the ball is floating in the middle - done

Page 19: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Oil Separator

• Temprite coalescent filters will pick up all dirt and particulates down to 0.3 microns

• Typical filter/driers only catch 50 microns or larger

• A second filter (shipped with the unit) is to be used as a replacement in 24 to 48 hours (no more then 5 psi drop)

Page 20: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Heating To Cooling Transition

• The compressor section includes a hot gas valve• After heating cycle, the earth loop temperature is low

– it was just operation as the evaporator

• In cooling the refrigerant returning to the compressor section could be two phase (flashing)

• In cooling mode after 3 minutes of operation, if the suction pressure drops below 95 psig (29°F), a hot gas solenoid valve opens for 10 seconds every 3 min.

– Compressor discharge gas is injected into the outlet of the EXV in the compressor box

• This process will repeat until the suction pressure is above 95 psig

• If after 60 hot gas injections, the suction pressure is still below 95 psig, the system will go into soft lock out for 60 minutes

Page 21: David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.

Well Seal Valve

• In 4 and 5 ton systems, the compressor section is equipped with a earth loop seal valve assembly to keep the refrigerant in the earth loop during the off cycle

• The assembly consists of a vapor line solenoid valve and a check valve for cooling mode

• The solenoid valve is opened during heating mode operation• The purpose of this assembly is to:

– Minimize the chance of refrigerant leaking indoors during the off cycle– Minimize the chance of leaking a large amount of refrigerant