DataSheet - Titan Power Plus SU-2.4

3
© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice. PRODUCT DATA SHEET TitanPowerPlus SU-2.4 Flat Plate Collector SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com 12-Year Warranty (when installed by a certified installer) SRCC Certified Solar Keymark Certified Sealing Casing Lateral thermal insulation Glazing Double-sided adhesive tape Absorber material (copper) Thermal insulation Rear panel 1 2 3 4 5 6 7 8 Technical Specifications Dimensions (in) 96.18 x 38.78 x 3.03 (244,3 x 98.5 x 7.7 cm) Gross Collector Area (ft 2 ) 25.94 (2.41 m 2 ) Net Aperture Area (ft 2 ) 24.43 (2.27 m 2 ) Ratio Net/Gross Area 0.94 Dry Weight (lbs.) 90.39 (41 kg) Fluid Capacity (gal.) 0.26 (1 L) Minimum Flow Rate (gpm) 0.173 (40 L/hr) Nominal Flow Rate (gpm) 0.587 (133 L/hr) Maximum Flow Rate (gpm) 1.05 (240 L/hr) Recommended Flow Rate (gpm) 0.176 - 0.167 (40 - 140 L/hr) Max Number of Collectors in Series 10 Tilt Angle (deg) 35 - 90 Maximum Operating Pressure (psi) 87 (6 bars) Recommended Operating Pressure (psi) 36.3 - 43.5 (2.5 - 3 bars) Stagnation Temperature 383 °F (195 °C) Materials Stainless Steel, grade AISI: 304; 0.7 mm gauge 3.2 mm toughened glass Mounting Options construction for sloping roof integration into sloping roof on flat roof with stand facade

Transcript of DataSheet - Titan Power Plus SU-2.4

Page 1: DataSheet - Titan Power Plus SU-2.4

© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.

PRODUCT DATA SHEETTitanPowerPlus SU-2.4 Flat Plate Collector

SunMaxx Solar, Inc.56 Broome Corporate PkwyConklin, NY 137481.877.786.62991.800.786.0329 faxwww.sunmaxxsolar.com

12-Year Warranty (when installed by a certified installer)SRCC CertifiedSolar Keymark Certified

SealingCasingLateral thermal insulationGlazingDouble-sided adhesive tapeAbsorber material (copper)Thermal insulationRear panel

1

2

3

4

5

6

7

8

Technical SpecificationsDimensions (in) 96.18 x 38.78 x 3.03

(244,3 x 98.5 x 7.7 cm)

Gross Collector Area (ft2) 25.94 (2.41 m2)

Net Aperture Area (ft2) 24.43 (2.27 m2)

Ratio Net/Gross Area 0.94

Dry Weight (lbs.) 90.39 (41 kg)

Fluid Capacity (gal.) 0.26 (1 L)

Minimum Flow Rate (gpm) 0.173 (40 L/hr)

Nominal Flow Rate (gpm) 0.587 (133 L/hr)

Maximum Flow Rate (gpm) 1.05 (240 L/hr)

Recommended Flow Rate (gpm) 0.176 - 0.167 (40 - 140 L/hr)

Max Number of Collectors in Series 10

Tilt Angle (deg) 35 - 90

Maximum Operating Pressure (psi) 87 (6 bars)

Recommended Operating Pressure (psi) 36.3 - 43.5 (2.5 - 3 bars)

Stagnation Temperature 383 °F (195 °C)

MaterialsStainless Steel, grade AISI: 304; 0.7 mm gauge

3.2 mm toughened glass

Mounting Optionsconstruction for sloping roof

integration into sloping roof

on flat roof with stand

facade

Page 2: DataSheet - Titan Power Plus SU-2.4

© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.

PRODUCT DATA SHEETTitanPowerPlus SU-2.4 Flat Plate Collector

SunMaxx Solar, Inc.56 Broome Corporate PkwyConklin, NY 137481.877.786.62991.800.786.0329 faxwww.sunmaxxsolar.com

PEAK POWER PER COLLECTOR UNIT (Wpeak)Peak Power (Wpeak) 1501 WThermal Capacity* 4.7 kJ/KFlow rate during test 160 l/hFluid for test Water-Glycol 33.3%

*Specific thermal capacity C of the collector without fluid, determined according to 6.1.6.2 of EN12975-2:2006

INCIDENT ANGLE MODIFIER (IAM)K1, transversal IAM at 50° 0.95

K2, longitudinal IAM at 50° 0.95

RELATIVE EFFICIENCY (η)Reference Gross Aperture Absorberη0 0.754 0.801 0.805a1 [WK-1m-2] 3.43 3.64 3.66a2 [WK-2m-2] 0.0106 0.0112 0.0113

-0.5

0

0.5

1

1.5

2

2.5

3

3.5

0.4 0.8 0.9 1.3 1.4 1.8 1.9 2.2 2.5 2.2 2.9 3.1 3.4 3.5 3.9 4.0 4.2 4.4

Pre

ssu

re L

oss

(psi

)

Flow Rate (Gpm)

GS2400 TIN H

GSE 2400 TIN Q

Linear (GS2400 TIN H)

Linear (GSE 2400 TIN Q)

GS 2400 TIN HGSE 2400 TIN Q

Page 3: DataSheet - Titan Power Plus SU-2.4

APPROVAL STAMPS

SunMaxx Solar, Inc.56 Broome Corporate PkwyConklin, NY 137481.877.786.62991.800.786.0329 faxwww.sunmaxxsolar.com

Architectural Stamps and Remarks

Contractor Stamp and Remarks

Contractor Note - Sign Below