Datasheet System Conquest 6_17.12.11_01 1/9 CONQUEST 6 Electronic control system for whirlpool Product datasheet VALANTIS SARL CH – 2610 ST-IMIER

description

CONQUEST 6. Electronic control system for whirlpool. Product datasheet. VALANTIS SARL CH – 2610 ST-IMIER. 1/9. Datasheet System Conquest 6_17.12.11_01. Features. ON/OFF pump. Spot light or RGB light (chromotherapy). Interval pump. Water level control. Water heater. ON/OFF blower. - PowerPoint PPT Presentation

Transcript of Datasheet System Conquest 6_17.12.11_01

Page 1: Datasheet System Conquest 6_17.12.11_01

Datasheet System Conquest 6_17.12.11_01 1/9

CONQUEST 6

Electronic control systemfor whirlpool

Product datasheet

VALANTIS SARLCH – 2610 ST-IMIER

Page 2: Datasheet System Conquest 6_17.12.11_01

2/9

Features

ON/OFF blower

ON/OFF pump

Manual blower power control (+/-)

Variation of blower flow (wave effect)

Interval pump Water level control

Spot light or RGB light (chromotherapy)

Concept

Disinfection mode (drying)

Safety rules

IMPORTANTFollow the directions for installation and connection of the control box. This one is not suitable for

medical use.

a) The box must be located in a dry and clean area with good ventilation and installed at least 3 centimers above the ground floor.b) Make sure that there are no unconnected wires inside the control box.c) Keep at least 2 centimeters between low and high power cables.d) All electrical parts must be mounted in a such way that they cannot fall down into the whirlpool.e) It is highly recommended to contact a state-registered electrician for installation. Valantis declines all responsability for consequences of damages caused by the device.f) Temperature ranges : storage -20 to 60°C, operating 0 to 45°C.g) It is not recommended to put on stress the system over an normal use. A security stops it automatically if any activity is detected after 20 minutes.h) On the main entry of the electrical installation, a fuse (FI) corresponding at least to the sum of the power supply of the device must be installed

We reserve the right to change the product and specification without notice. VALANTIS SARL

CH – 2610 ST-IMIER

Water level ControllerNewjac 8

Blower

Spot Chromo 1

Panel Conquest 6

Driver Chromo 2 Spot Chromo

2

Pump

Spot

Interval blower Rincing mode (flush)

Rincing valve or chemical disinfection

Datasheet System Conquest 6_17.12.11_01

Water heater

Water heater

Chemical Disinfection

Page 3: Datasheet System Conquest 6_17.12.11_01

3/9

Components

Plastic enclosure 45x30x15mm1 LED indicatorAdjustable by trimmerCable length 1800 mm. IP65ROHS

Water level sensor « TLS1 »Code 0010137600

VALANTIS SARLCH – 2610 ST-IMIER

Panel Conquest 6Code VPF09026X1

Non-contractual picture

Non-contractual picture

Datasheet System Conquest 6_17.12.11_01

Oblong shape plastic enclosure 174 x 30 mmChrome coated enclosure.Membrane foil front panel6 buttons 2 LED’s indicatorCable length 2000 mm.IP65 / ROHS

Controller Newjac 8Code VPF07002C1

Control box 230V 50/60 Hz 16A2 variable outputs (triacs)3 ON/OFF outputs (relays)Plastic enclosure 200x155x80 mmFit out with- 4 cable glands PE M16 for cable 5-10 mm.- 3 grommets (shutters) M16IP56ROHS

Non-contractual picture

Page 4: Datasheet System Conquest 6_17.12.11_01

4/9

Components 2/2

Driver Chromo 2Code VPF10030A1

Plastic enclosure 130 x 90 x 55 mm2 inputs for RGB spot lightFit out with :- 1 x PE M16 for cable diam. 5-10 mm- 1 x grommet (shutters) M16- IP56 / ROHS

VALANTIS SARLCH – 2610 ST-IMIER

Spot ChromoCode VPF10031A1

Chrome coated enclosure diam. 55 mmThickness 1.5 mm8 colours (white, red, orange, yellow,green, blue, indigo, purple)Cable length 2000 mm. with PE M16 + nutIP65 / ROHS

Non-contractual picture

Non-contractual picture

Datasheet System Conquest 6_17.12.11_01

Page 5: Datasheet System Conquest 6_17.12.11_01

5/9

Control box connection

Specification

Rated voltage :230V, 50/60Hz, 1 phaseRated power : 3680WRated current :16A

Maximum load

Water heater: 230V, 9A, 2070WSpot : 230V, 9A, 2070WRincing valveor chemical disinfection: 230V, 9A, 2070WPump : 230V, 6A, 1380WBlower : 230V, 6A, 1380W

The sum of the loads must not exceed rated power and current

VALANTIS SARLCH – 2610 ST-IMIERDatasheet System Conquest 6_17.12.11_01

PowerSupply230V

Panel Conquest 6Code VPF08012X15V

Water level sensor TLS1Code 00101376005V

Spot230V

Pump230V

+ = whiteSD = brown- = green

+

-SD

Rincing valve230VorChemical disinfection230V

WaterHeater230V

Blower230V

Page 6: Datasheet System Conquest 6_17.12.11_01

6/9

Recommended connection with RGB spot light

VALANTIS SARLCH – 2610 ST-IMIER

IMPORTANT : 5V cables (panel, temperature and water level sensor) must notcross power areas of the electronic board. Outside the enclosure, it is highlyrecommended to separate cabling of 230V and 5V cables.

Datasheet System Conquest 6_17.12.11_01

Page 7: Datasheet System Conquest 6_17.12.11_01

1. ON/OFF spot or RGB spot light2. ON/OFF pump / Interval pump/ Water heater / Disinfection (option)3. Variation blower / Interval blower4. ON/OFF blower5. + blower 6. - blower 7. LED pump8. LED blower

VALANTIS SARLCH – 2610 ST-IMIER

FUNCTION BUTTON ACTION ON BUTTON

RESULT OF ACTION ON BUTTON / STATE LED INDICATOR

Switch on the system."Waiting for water" mode enable (not enough water in the whirlpool.) Panel disable for use.

LED 8 blinks each 5 sec.

Enough water in the whirlpool. Ready for bath. Panel enable for use.

LED 7 and 8 ON

1st press Blower ON. Power flow 100%. LED 8 blinks 2 x per sec.

2nd press Blower OFF. LED 8 ON

Press Blower ON. Power flow 100%. Available for +/- LED 8 blinks 2 x per sec.

1st continued press

Decrease power of blower LED 8 blinks 2 x per sec.

2nd continued press

Increase power of blower LED 8 blinks 2 x per sec.

Press Blower OFF LED 8 ON

Press Blower ON. Power flow 100%. Available for Variation / Interval

LED 8 blinks 2 x per sec.

Press Start Variation program LED 8 blinks 2 x per sec.

Press Switch from Variation to Interval mode and so on at each next action on button

LED 8 blinks 2 x per sec.

Press Blower OFF LED 8 ON

1st press Pump ON. Power flow 100%. Water heater ON (if connected)

LED 7 blinks 2 x per sec.

2nd press Pump OFF. Water heater OFF. LED 7 ON

Press Pump ON. Power flow 100%. LED 7 blinks 2 x per sec.

Press (long 2 sec.)

Start interval. Water heater OFF (if connected) LED 7 blinks 2 x per sec.

Press Pump OFF LED 7 ON

INTERVAL WATER

AIR - / +

VARIATION / INTERVAL AIR

AIR

WATER

1 2 3 4 5

7

6

8

User manual 1/2

Datasheet System Conquest 6_17.12.11_01 7/9

Page 8: Datasheet System Conquest 6_17.12.11_01

VALANTIS SARLCH – 2610 ST-IMIER

FUNCTION BUTTON ACTION ON BUTTON

RESULT OF ACTION ON BUTTON / STATE LED INDICATOR

CHEMICAL DISINFECTION (OPTION)

Press (long 2 sec.)

Pump + Disinfection valve ON After 5 sec. Disinfection valve OFF After 3 min. Pump OFF. During the cycle, button 2 allows to stop the process. Other functions are not available.

LED 7 blinks 2 x per sec.

1st press Start Spot light or Chromotherapy light program

2nd press Stop Spot light or Chromotherapy light program

1st press Start chromotherapy light program

Double click Fix on current colour

Next double click Fix on next colour

2nd press Stop RGB light

All the functions are automatically stopped after 20 min. of inactivity

LED 7 and 8 ON

This function is enable only if the water level sensor has detected water during at least 2 min.Whirlpool is emptying. No detection of water during 12 min. (continually) = Disinfection mode enable.

LED 7 and 8 blink each sec.

After 12 min, Blower ON during 3 min. LED 8 blinks each sec.Blower OFF. Return to "Waiting for water" mode LED 8 blinks each 5

sec.During this cyle button 4 is enable to stop drying modeThis function is enable only if the water level sensor has detected water during at least 2 min.Whirlpool is emptying. No detection of water during 8 min. (continually) = Disinfection mode enable.

LED 7 and 8 blink each sec.

After 8 min, Rincing valve ON during 1 min. LED 7 blinks each sec.Then waiting time during 3 min. LED 7 and 8 blink each

sec.Finally Blower ON during 3 min. LED 8 blinks each sec.Blower OFF. Return to "Waiting for water" mode LED 8 blinks each 5

sec.During this cyle button 4 is enable to stop disinfection mode

DISINFECTION OPTION NR. 2 : RINCING+DRYING

DISINFECTION, OPTION NR. 1 : DRYING

RGB LIGHT (MANUAL)

SPOT LIGHT OR RGB LIGHT (AUTOMATIC)

User manual 2/2

Datasheet System Conquest 6_17.12.11_01 8/9

Page 9: Datasheet System Conquest 6_17.12.11_01

VALANTIS SARLCH – 2610 ST-IMIER

Programs

The panel contains several programs whose can be selected by a code.The following programs are available :

Program

Nr. Description

ST6A 1 Panel Conquest 6A without disinfection

ST6AT 2 Panel Conquest 6A with progressive drying disinfection

ST6E 3 Panel Conquest 6E without disinfection

ST6R 4 Panel Conquest 6E with rincing disinfection

ST 5 Panel Conquest 6 without disinfection

STAT 6 Panel Conquest 6 with progressive drying disinfection

STET * 7 Panel Conquest 6 with rincing + progressive drying desinfection

TST 8 Test (Valantis internal use only)

Re-programming instructions :

Switch on the system with water into the whirlpool.Within 2 min., drain the whirlpool until the TLS don’t detect water anymore (LEDs blink each 5 sec.).Press buttons 0 1 2 0 1 during an interval of maximum 2 min. LEDs blink 8 times per sequence.Button 0 = select program. Observe corresponding LED sequence blinking as per a.m. program nr.Button 1 = save selected program.Button 2 = cancel the selection. Return to the previous program.

* Ex-factory setting

Datasheet System Conquest 6_17.12.11_01

012

9/9