PRODUCT DATA SHEETStorMaxx Ptec Storage Tanks
SunMaxx Solar, Inc.56 Broome Corporate PkwyConklin, NY 137481.877.786.62991.800.786.0329 faxwww.sunmaxxsolar.com
Technical Specifications StorMaxxPtec 502HX
StorMaxxPtec 802HX
StorMaxxPtec 1052HX
StorMaxxPtec 1302HX
Capacity (gal) 50 80 105 130
Dia. w/o insulation (in)* 19.7 19.7 23.6 25.6
Dia. w/ insulation (in) 23.6 23.6 27.6 29.5
Insulation (in)* 2
Height w/ insulation (in) 48.5 66.8 65.4 70.2
Tilted height (in) 53.9 70.9 70.9 77.6
Heat area top/bottom (ft2) 6.5/8.6 8.6/12.9 10.8/16.2 12.9/19.4
Water content WT top/bottom (gal) 1/1.3 1.3/2 1.7/2.5 2/3
Volume flow WT top/bottom (gal/hour) 185/317 264/423 317/528 370/634
Pressure loss WT top/bottom (psi) 0.44/1 .5/1.3 .65/1.74 .8/3.6
Performance index top/bottom†
according to DIN 4708 1.23/3.6 1.8/8 2.1/11 2.5/14
Continuous output top/bottom according to DIN 4708 (50°F/180°F/115°F) (gal/hour) 108/188 160/256 190/312 219/370
Max. T/max. P TW (°F/psi) 200 / 145
Max. T/max. P HZG‡ (°F/psi) 320/363
Cold-/Hotwater, ext. thread (KW/WW) (in) G1
Circulation, ext. thread (Z) (in) G¾
Heat exchangers, all ext. threaded (VL/RL) (in) G¾
Electric heating, int. thread (E-HZG) (in) G 1½
Nominal width of the inspection flange (RFL) DN 110
Connections for sensors/regulators (F1, F2) Sensor sleeve, inside diameter 9 mm
Thermometer connection M8 thermometer optional
* Insulation is not detachable.† In order to achieve the performance NL given Here, the boiler output needs to be higher than the stated continuous output.‡ The working medium of the heat exchanger is water in liquid state only.
• Upright storage tank made of steel S235JRG2 with 2 large surface bare-tube heat exchangers• Enameling in accordance with DIN 4753 Part 3 on the inside, primer applied to the outside• Magnesium protection anode of 1¼’’ provided for completion of the cathodic corrosion protection
in accordance with DIN 4753 Part 6• Sensor tube included• As standard fitted with a 1½’’ sleeve for re-fitting of an electric
heating element• Inspection opening 180 x 110 x LK 150• All external threads are flat sealing• CFC-free hard PU-foam insulation with a thickness of 50 mm and a casing of foil-clad, colored
synthetic material in accordance with DIN 4753 Part 8, RAL colours 9006; 9010; 2002; 5015• Compressive strength 10 bar
© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.
PRODUCT DATA SHEET, continuedStorMaxx Ptec Storage Tanks
SunMaxx Solar, Inc.56 Broome Corporate PkwyConklin, NY 137481.877.786.62991.800.786.0329 faxwww.sunmaxxsolar.com
1. Hot Water Outlet2. Cold Water Inlet3. Solar Supply4. Solar Return5. Auxiliary Coil Port6. Recirculation Port7. Magnesium Anode8. Temp Sensor Well9. Cleaning Flange10. Electric Heating Element*11. Thermometer*