Model : Asterix Part No: SL-AST-001
Electrical:
Supply Voltage 200-240V, 50-60Hz (auto-ranging)Rated Current 6A ( @240V )Output Power 24V, 75W per port - Total 1200W
Fuse Rating 2x10A-T
Control:
Network control of unit with proprietary protocol to control LEDs
Physical:
2U Rack Mount Chassis Rack and surface-mountableDimensions 480mm (W) x 88mm (H) x 737mm (D)
Weight 13kgData Input RJ-45
Power Input IEC 60320-C14Power and Data Output 16 x 4-Pin connector
Airflow 2 Fan input front panelOperating Temperature 0°C..+50°C, <80% RH
Storage Temperature 0°C..+50°C, <60% RHEnvironment IP20
Accessories:
1 x Power cable1 x Rack Mounting Kit
Certifications:
CE, RoHs
88
88
737
ShowLED Asterix Datasheet
CREATIVE LED SOLUTIONS©Copyr ight 2018 ShowLED, A l l R ights Reserved www.showled.com // T: +971 6 557 83 07 // E : [email protected] FZC // SAIF Zone Q4 006-007 // Shar jah // PO Box: 120888 // United Arab Emirates
Asterix is a power/data supply for the ShowLED range of LED pixels -Animation, Hybrid & Dexter.
It is designed for large LED setups and incorporates features to allowfor remote monitoring. The unit has 16 outputs; each port rated at24V/75 Watts with a total of 1200 Watts/unit.
A user interface gives access to network settings, pixel test procedures and for setting LED configurations with redundancy or repair modes.
Asterix has unique features to protect controller ports and to alert pixelfailures. Over voltage, over temperature, over current and shortcircuits are protected and reported with the built-in Remote MonitoringSystem (RMS).
88
88
737
ShowLED Asterix Datasheet
CREATIVE LED SOLUTIONS©Copyr ight 2018 ShowLED, A l l R ights Reserved www.showled.com // T: +971 6 557 83 07 // E : [email protected] FZC // SAIF Zone Q4 006-007 // Shar jah // PO Box: 120888 // United Arab Emirates
Dimensional Data Typical Connection Diagram
Typical Depth with connectors - 850mmMedia Player
Network SwitchV-Box
Asterix #2 Dexter - Pixels 1025 to 2048
Dexter - Pixels 1 to 1024
Asterix #1
Rear View
Front View
Side Views
IEC Power Inlet
Menu LCD Status LEDsMenu Control Switch
Power Switch
Dexter Lead-Out Cables
To Network Switch
Smart Current Limiter (SCL)
The ShowLED SCL is the ideal combination between an electronic and a physical fuse.At the time of initial setup, the SCL ‘learns’ the typical current values of the attachedloads. After this learning process the SCL will react fast to a fault condition - within 0.2seconds, even if the current is only at 105% above the recorded threshold.
Auto-reset: if the fault condition disappears the SCL will auto-reset without the need for a manual intervention.
Physical fuse: a last line of defense in case the power supply or the Smart Current Limiter should fail.
Protection- over voltage - over current- short circuit- under voltage
ShowLED Asterix Datasheet
CREATIVE LED SOLUTIONS©Copyr ight 2018 ShowLED, A l l R ights Reserved www.showled.com // T: +971 6 557 83 07 // E : [email protected] FZC // SAIF Zone Q4 006-007 // Shar jah // PO Box: 120888 // United Arab Emirates
Remote Monitoring System (RMS)
The RMS system provides real time reporting of the system status indicting any faults andtheir location on the Media Facade.
With this information, routine and preventative maintenance can be carried out.
Fault information will be notified via an e-mail report.
Asterix Controllers RMS Visual Display Receiving Upates Reporting via E-mail
TEL
+97
1 6
557
83 0
7 F
AX
+97
1 6
557
84 0
9 E
-MA
IL: I
NFO
@SH
OW
LED
.CO
M W
WW
.SH
OW
LED
.CO
M
© Copyright 2017 ShowLED, All Rights Reserved.
CREATIVE LED SOLUTIONS
TEL
+97
1 6
557
83 0
7 F
AX+
971
6 55
7 84
09
E-M
AIL
: IN
FO@
SHO
WLE
D.C
OM
WW
W.S
HO
WLE
D.C
OM
© Copyright 2017 ShowLED, All Rights Reserved.
39
REMOTE MONITORING SYSTEM
Controller racks RMS Collector Warning mails
Reporting SCLs 100%
UT =284
1 E
rror re
po
rting
- SC
L 3
41
3B
24
TU
_5
3C
72
ha
s a d
ata
pro
ble
m
UT =301
Reporting SCLs 100%
Reporting SCLs 100%
UT =320
1 Error reporting - SCL 3413B24TU_53C72 has a data problem
! Currently no errors
! Currently no errors