DATA SHEET VARIAIR U 5.101 ROTARY VANE– VACUUM PUMPS

5
MAKE IT BECKER. VARIAIR U 5.101 DATA SHEET ROTARY VANE– VACUUM PUMPS oil-lubricated and air-cooled frequency inverter

Transcript of DATA SHEET VARIAIR U 5.101 ROTARY VANE– VACUUM PUMPS

Page 1: DATA SHEET VARIAIR U 5.101 ROTARY VANE– VACUUM PUMPS

MAKE IT BECKER.

VARIAIR U 5.101DATA SHEET

ROTARY VANE–VACUUM PUMPSoil-lubricated and air-cooled

frequency inverter

Page 2: DATA SHEET VARIAIR U 5.101 ROTARY VANE– VACUUM PUMPS

2 • BECKER VARIAIR U 5.101

1)

2)

According to DIN EN ISO 11203, accuracy class of measurement: class 2, extended measurement uncertainty: 3 dB1 m [39.4 inch] distance, at medium load, both connection sides pipedBecker Lube M100 mineral • S100 synthetic • SL100 foodGas ballast valve: vacuum 1.0 mbar absolute with opened gas ballast valve; water vapour tolerance max. 7 mbar; water vapour capacity max. 0.9 l/h (at 85°C operating temperature)

1234567▪

▪▪

Vacuum connection (G1¼)

Exhaust air (diverter)

Oil filler cap (G¾)

Oil sight glas (G1)

Screw plug for oil drain (G½)

Rubber buffer position

optional: threaded connector for exhaust air (G1¼)

incl. gas ballast valve, non-return valve, oil separator

and oil filter

The motor illustration may vary

Dimensions in mm [inch]

Nominalcapacity

Vacuum absolutefor continous operation

Frequency Emission sound pressure level 1)

Weight Oil 2)M U

V W3~

3~

3~

L1L2 L3

m³/h mbar Hz dB(A) kg l Frequency inverter A

max. max. 50 Hz 60 Hz VAU4/4 max.

140 0.1 40–65 65 68 71.5 2.04.0 kW400–480 V ±10%50/60 Hz

16

15[0

.6]

736 [29]

≈717 [≈28.2]

31[1.2]

138 [5.4]

360 [14.2]

348 [13.7]

max.

min.

in

out

3

4

5

2

380 [15]

189 [7.4]

130

[5.

1] 28

8 [

11.3

]

33

0 [

13]

≈3

73 [

≈14

.7]

M8

182 [7.2]

194 [7.6]20

[0.8

]

77[3]

371 [14.6]

457 [18]

25

3 [

10]

≈240 [≈9.5]

141.5 [5.6]

1

G1¼

57.5[2.3]

32[1.3]

12[0

.5]

182

[7.2

]77

[3]

6

666

18.5[0.7]

138[5.4]141.5[5.6]

337 [13.3]

369 [14.5]

78[3.1]

22

3 [

8.8

]

G1¼

7

Page 3: DATA SHEET VARIAIR U 5.101 ROTARY VANE– VACUUM PUMPS

BECKER VARIAIR U 5.101 • 3

-99,99 -99,9 -99 -90 00,01 0,1 1 10 100

160

2000

1000

120

80

40

0 0

100

80

60

40

20

200

150

100

50

0 32

3 4

2

1

3

2

1

0 0

0,1 1 10 100 1000-999,9 -999 -990 -900 0

Suction air rate refers to the intake pressureReference data (atmosphere): 1000 mbar (100 kPa), 20°C (68°F)Tolerance: ±10%

[kPa]-99.99 -99.9 -99 -90 relative 0

0.01 0.1 1 10 absolute 100

SU

CT

ION

AIR

RA

TE

[m

³/h

]

[l/m

in]

EX

HA

US

T A

IR T

EM

PE

RA

TU

RE

[°C

]

[°F]

MO

TO

R S

HA

FT P

OW

ER

[k

W]

[hp

]

0.1 relative-999.9 absolute

VACUUM [mbar]

Page 4: DATA SHEET VARIAIR U 5.101 ROTARY VANE– VACUUM PUMPS

4 • BECKER VARIAIR U 5.101

6

5

3

2 4

1

1)

▪See separate data sheetCombination options on request

VARIANTS AND ACCESSORIES

Oil level switch Oil temperature monitor Maintenance indicator Ball valve

123456

Oil level switch 1) (G1)

Oil temperature monitor 1) (G½)

Maintenance indicator 1) (G¾) for oil separating elements

Ball valve (G½), with locking and hose connector 19 mm (0.75 inch)

Temperature sensor PT100Water cooler U5.100-0-114.2 1) with connectors for hoses with an external diameter of 8 mm (0.32 inch)

Optional GAS BALLAST VALVE for increased water vapour tolerance (3.0 mbar absolute)

water vapour tolerance: max. 62 mbar; water vapour capacity: max. 2.4 l/h (at 85°C operating temperature)

THREADED CONNECTOR for exhaust air (G1¼)

ACCESSORIES

▪▪

External suction filter 1)

Oil: Becker Lube M100 mineral, S100 synthetic and SL100 food

Page 5: DATA SHEET VARIAIR U 5.101 ROTARY VANE– VACUUM PUMPS

MAKE IT BECKER.

www.becker-international.com

20

21-

01-

28

Rig

ht

of

mo

difi

cat

ion

re

serv

ed