Data Sheet Measurement and Automation Systems 2101198-AF - ABB · PDF file• Local...

4
Data Sheet 2101198-AF Measurement and Automation Systems Line Sheets System Software WINCCU - EFM HOST Complete Gas Volume/Energy Data Management API21.1 Compliant Audit Trail 13 standard reports (e.g. Hourly / Daily Volume, missing data, field balance) User Configurable Variance Reports Multiple Export formats (e.g. CSV, ASCII, PGAS, CFX) Import non-Totalflow EFM data via XML Full featured gas volume editor Microsoft Access or SQL Server databases LAN/WAN multi-user capability Remote Communications ο Multiple Communication Port Controller ο Radio, Telco, CDPD, Satellite, and more ο Automatic Retry Groups ο Exception Reporting Support ο TCP/IP socket interface Task Scheduler ο Status Polls, EFM Collects ο Batch configuration of field devices ο Reporting, emailing WEBCCU WINCCU add-on works over internet or intranet Browser presentation capability for WinCCU database Microsoft .NET Technology Post near real-time data to internet site Graphical presentation of historical trends Standard WinCCU Reports ο Flow Data, Alarms, Events, Characteristics, Trends Flexible, “Active Reports” editor Flexible, ChartFX graphing environment Demand polling and configuration of field de- vices TF.NET INTERNET / INTRANET DATABASE NAVIGATION and VIEWING Browser presentation capability for virtually any database Microsoft .NET technology Access near real-time data from web site Graphical presentation of trend data Standard WinCCU reports (Flow Data, Alarms, Events, Characteristics, Trends) Flexible, “Active Reports” editor Demand polling and configuration of field devices PCCU CONFIGURATION and COLLECTION Setup Totalflow devices and collect data. Windows application Local interface to all ABB Totalflow Flow Computers, RTU’s, and Chromatographs Calibrate and configure all IO Local data collection Local data graphing and reporting Configure remote communication ports Configure Trend Files in addition to standard EFM Historical Files Diagnostics - Troubleshooting Monitor real time status Program analog and digital Operations Program display and keypad functionality Configure and troubleshoot NGC View chromatograms and configure cycle times Remote configuration capabilities

Transcript of Data Sheet Measurement and Automation Systems 2101198-AF - ABB · PDF file• Local...

Data Sheet 2101198-AF

Measurement and Automation Systems Line Sheets

System Software

WINCCU - EFM HOST

Complete Gas Volume/Energy Data Management • API21.1 Compliant Audit Trail • 13 standard reports (e.g. Hourly / Daily

Volume, missing data, field balance) • User Configurable Variance Reports

• Multiple Export formats (e.g. CSV, ASCII, PGAS, CFX)

• Import non-Totalflow EFM data via XML • Full featured gas volume editor • Microsoft Access or SQL Server databases • LAN/WAN multi-user capability

Remote Communications ο Multiple Communication Port Controller ο Radio, Telco, CDPD, Satellite, and more ο Automatic Retry Groups ο Exception Reporting Support ο TCP/IP socket interface Task Scheduler ο Status Polls, EFM Collects ο Batch configuration of field devices ο Reporting, emailing

WEBCCU

• WINCCU add-on works over internet or intranet • Browser presentation capability for WinCCU

database • Microsoft .NET Technology • Post near real-time data to internet site • Graphical presentation of historical trends • Standard WinCCU Reports

ο Flow Data, Alarms, Events, Characteristics, Trends

• Flexible, “Active Reports” editor • Flexible, ChartFX graphing environment • Demand polling and configuration of field de-

vices

TF.NET INTERNET / INTRANET DATABASE NAVIGATION and VIEWING

• Browser presentation capability for virtually any database

• Microsoft .NET technology • Access near real-time data from web site • Graphical presentation of trend data • Standard WinCCU reports (Flow Data, Alarms,

Events, Characteristics, Trends) • Flexible, “Active Reports” editor • Demand polling and configuration of field devices

PCCU CONFIGURATION and COLLECTION

Setup Totalflow devices and collect data. • Windows application • Local interface to all ABB Totalflow Flow

Computers, RTU’s, and Chromatographs • Calibrate and configure all IO • Local data collection • Local data graphing and reporting • Configure remote communication ports • Configure Trend Files in addition to standard

EFM Historical Files • Diagnostics - Troubleshooting • Monitor real time status • Program analog and digital Operations • Program display and keypad functionality • Configure and troubleshoot NGC • View chromatograms and configure cycle times • Remote configuration capabilities

Measurement and Automation Systems 2101198-AF

2

EZ Blocks

• Provides intuitive, graphical way to create custom Operations

• Works with G4 devices • Similar to Function Block Language in IEC-61131 • Simple yet powerful library of blocks • Offline development possible with simulator • Built-in debugger

VAS VOICE ALARM MESSAGING • Windows application • Dialogic Speechboard Management • Call in / Call out services

Supports up to 4 Phone Lines ο (2) Call In, (2) Call Out Comprehensive Callout on Alarm List ο Multiple Regions ο Multiple Receivers of Call with Priority

• Confirmation of authorized receiver of call • Log records of callouts • Call received confirmation

• Trigger callout from polled or exception alarms

TDS32 OPC / DDE DRIVER

• Totalflow protocol link to all OPC / DDE aware software systems

• Coexist with WinCCU or as Stand Alone Link to other systems

• Retrieve exception reporting status from Totalflow devices

• Browse functionality • Persistent data retention • Supports 50,000+ Tags

PLUNGER ANALYSIS SOFTWARE

Windows application for optimizing plunger control parameters in a Flow Computer or RTU • Increase gas production volumes • Reduce extended shut-ins due to liquid loading • Lower operating costs • Characterize well conditions to optimize liquid

production

Measurement and Automation Systems 2101198-AF

3

WELLTELL WIRELESS UTILITY

• Configure radio settings to enhance wireless communications and troubleshoot field installa-tions

• Set battery wake and sleep thresholds to protect from permanent damage

• Change channel and frequency settings to mini-mize interference

• Adjust baud rates for adding multiple IO clients to a single host

WELLTELL LOCAL CALIBRATION SOFTWARE

• Calibrate at the IO device location to eliminate the need for a second person at the RTU or Flow Computer

• Calibrations can be sent wirelessly to the RTU • 2,3 and 5 point calibrations of Analog Inputs • Calibration support for Analog Outputs and Tem-

perature RTDs

MASTERLINK

• Windows application for LevelMaster Tank Level Sensor setup

• Configure communications • Establish unique device ID • Calibrate surface and interface levels • View level and temperature

Measurement and Automation Systems 2101198-AF

Recommended System Requirements and Supported Operating Systems

Power and Productivity for a Better World. ™

www.abb.com/totalflow www.abb.us

www.abb.com

ABB Inc. Totalflow Products 7051 Industrial Blvd. Bartlesville, OK 74006 Tel: (918) 338-4888 Fax: (918) 338-4699 (800) 442-3097

For more information, please contact your local ABB Totalflow representative or visit our website.

Pent

ium

IV, 2

GHz

Mem

ory

Hard

Driv

e M

emor

y (d

ata

stor

age

excl

uded

)

CD R

OM

driv

e

SVG

A or

hig

her r

esol

utio

n

9 pi

n S

eria

l por

t or

USB

Win

cow

s 7

Win

dow

s X

P

Win

dow

s Vi

sta

Win

dow

s Se

rver

200

0

Win

dow

s Se

rver

200

3

Win

dow

s Se

rver

200

8

Mic

roso

ft SQ

L Se

rver

200

0 or

20

05

IIS 6

.0

.NET

Fra

mew

ork

2.0

or h

ighe

r

Vers

ions

Sup

port

PCCU 1 GB 1 GB 1 3 7.18 and higher

Plunger Anlys 1 GB 1 GB 1 2.0 and higher

EZ Blocks 1 GB 1 GB 1 5 1.0 and higher

WellTell4 1 GB 10 MB 1.0 and higher

MasterLink 1 GB 1 MB 1.0 and higher

WinCCU 1 GB 1 GB 1 2 6.08 and higher

TF.net 4 GB 1 GB 3.0 and higher

WebCCU 1 GB 1 GB 3.0 and higher

VAS6 1 GB 1 GB 1.0 and higher

TDS 1 GB 1 GB 1.0 and higher

1 - Edgeport1 recommended for USB to Serial conversion2 - Requires manual installation3 - NGC not supported4 - Utility and Local Calibration Software5 - .NET 3.5 SP-1 recommended

CLI

ENT

SOFT

WA

RE

HO

ST

SOFT

WA

RE