Data sheet Fan Systems

Transcript of Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise...

Page 1: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

1230

019

09

EX

P/G

B/F

an S

yste

ms/

DA

TA/0

416

Data sheetFan Systems

Page 2: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

2

Ta b l e o f c o n t e n t s

Fan type BTD/BPD/BTK/BPK general ......................................Page 19

Fan type BTD/BPD/BTK/BPK 200 .................................... Page 20 - 21

Fan type BTD/BPD/BTK/BPK 300 .................................... Page 22 - 23

Fan type BTD/BPD/BTK/BPK 400 .................................... Page 24 - 25

Fan type BTD/BPD/BTK/BPK 500 .................................... Page 26 - 27

Fan types MCD 30 - 50 general ............................................Page 28

Fan type MCD 30 .................................................................Page 29

Fan type MCD 40 .................................................................Page 30

Fan type MCD 50 .................................................................Page 31

Section 03. Fan type BTD/BPD/BTK/BPK

Section 04. Fan types MCD 30 - MCD 50

Section 06. Accessories

Section 01. Fan types MTD 20 – MTD 40

Table of contents ..................................................................Page 02

Fan types ..............................................................................Page 03

How to read fan graphs ........................................................Page 06

Section 00. General

Fan types MTD 20 - MTD 40 general ....................................Page 07

Fan type MTD 20 ..................................................................Page 08

Fan type MTD 22 ..................................................................Page 09

Fan type MTD 25 ..................................................................Page 10

Fan type MTD 30 ..................................................................Page 11

Fan type MTD 35 ..................................................................Page 12

Fan type MTD 40 ..................................................................Page 13

Section 02. Fan types MTK 40- MTK 75

Fan types MTK 40 - MTK 75 general ....................................Page 14

Fan type MTK 40 ..................................................................Page 15

Fan type MTK 45 ..................................................................Page 16

Fan type MTK 55 ..................................................................Page 17

Fan type MTK 75 ..................................................................Page 18

Acoustic booths type AB ............................................... Page 40 - 41

Fan types MCK 40 - MCK 100 general .................................Page 32

Fan type MCK 40 .................................................................Page 33

Fan type MCK 50 .................................................................Page 34

Fan type MCK 60 .................................................................Page 35

Fan type MCK 70 .................................................................Page 36

Fan type MCK 80 .................................................................Page 37

Fan type MCK 90 .................................................................Page 38

Fan type MCK 100 ...............................................................Page 39

Section 05. Fan types MCK 40 - MCK 100

Page 3: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

3

F a n t y p e s

Radial fan with P-impeller Radial fan with T-impeller

There are many types of fan impeller, each of which is designed for a given task:

• Radial fan with P-impeller • Radial fan with T-impeller

Radial fan with P-impellerHas flat backward-inclined blades and is designed for clean air transport. This type has the following properties:

• High efficiency• Robust construction • Only small variations in volume flow if resistance fluctuates.

Radial fan with T-impellerHas backward-inclined blades and is designed for transport of a range of materials. This type has the following properties:

• Medium and high-pressure versions• Robust construction • High degree of self-cleaning• Can handle large material volumes• Special version available for transport of plastic and paper• All fans are ATEX-certified in accordance with Directive 94/9 EF.

TemperaturesThe graphs indicate 20°C. Fans can be used for temperatures up to 60°C without physical modification. At temperatures other than 20°C, the air density is changed. This means it may be necessary to adjust the min-1. At temperatures over 20°C the fan will generally be giving reduced effect in relation to the rise in temperature. For high temperatures, the following should be taken into consideration: bearings and lubricant - whether the fan should be fitted with cooling wings – whether the motor should be supplied with extra cooling (particularly important for frequency regulation). For temperatures in excess of 60°C, extra cooling is required.

Fan typesMotors and fans are usually supplied as a unit. JKF has designed its fans for optimal performance, and it is vital to select the right one for any given task. The speed at which the fan is to run can be seen from the graph for that fan. The power input required depends on resistance in the system.

Blowers are delivered as standard in position RV (LG 270 according to Eurovent)

Page 4: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

4

F a n t y p e s

Type MTD

Type MTK

Type BTD/BTK - BPD/BPK

• Transport fan

• Direct drive

• Air volume from 750 to 11,000 m³/h

• Pressure: 110 –440 mm WG

Page 7-13

• Transport fan

• Indirect drive

• Air volume from 2,800 to 40,000 m³/h

• Pressure: 60 – 600 mm WG

Page 14-18

• Transport fan

• Indirect drive

• Air volume from 2,000 to 13,000 m³/h

• Pressure: 250 – 1,000 mm WG

Page 19-27

Page 5: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

5

F a n t y p e s

Type MCD

Type MCK

• Clean air fan

• Direct drive

• Air volume from 2,000 to 88,000 m³/h

• Pressure: 120 – 600 mm WG

Page 28-31

• Clean air fan

• Indirect drive

• Air volume from 2,500 to 115,000 m³/h

• Pressure: 80 – 600 mm WG

Page 32-39

Page 6: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

6

H o w t o r e a d f a n g r a p h s

In practice it is highly likely that the operational

point for a fan will not appear on the

graphs referring to useful effect, but between

them.

Determination of values for the operational

point selected can be calculated using the

following formulas:

Total useful effect

ηT = p × Q × 9,81

1000 × P

p = Total pressure read from graph in mm WG

Q = Air volume read from graph in m³/h

P = Power input to electric motor in kW

When calculating useful effect

When only working with power input to the

impeller, the following formulas can be used:

For direct drive fans the useful effect is

ηD = ηT + 10%

For indirect drive fans the useful effect is

ηID = ηT + 10% + 6%

For noise calculation

The following formulas can be used along with

sound measurement apparatus:

min-1 adjustment:

L2 = L1 + 60 × log n2

L1 = Noise level at min-1 n1

n2 = New min-1

Noise level at various distances:

LPA = LWA - (20 × log R) + (10 × log Q) - 11 dB(A)

LWA = Noise effect

R = Distance between noise source and receiver

Q = Direction factor

Q = 2 (hemispherical spread)

Q = 4 (quartspherical spread)

Q = 8 (octaspherical spread)

5063

6159

5750 %

0

20

40

60

80

100

120

140

160

180

0 500 1000 1500 2000 2500 3000

0 5 10 15 20 25 30 35 40 45 50

0

200

400

600

800

1000

1200

1400

1600

5063

6159

5750 %

0

20

40

60

80

100

120

140

160

180

0 500 1000 1500 2000 2500 3000

0 5 10 15 20 25 30 35 40 45 50

0

200

400

600

800

1000

1200

1400

1600

N/m² mm WG

hp kW

m³/h

m³/min.

Air volume

Power input in kW

Pressure in mm WG

Total useful effect incl. loss in electric motor, transmission, bearings and impeller + housing

Total pressure = static + dynamic pressure in outlet opening on- housing

Impeller min-1

Volume flow in m³/h

Dynamic pressure in outlet opening on housing

2800 min-1

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

0.20.40.60.81.01.21.41.61.82.02.22.42.62.8

0.0

97

7074

85 dB(A)

Sound pressure level at 1 m = noise to surroundings in dB(A)

2800 min-1

Power input to electric motor on fan

Example at 1250 m³/h

Read-off from graph for useful effect and pressure will show 150 mm WG and useful effect of 63%.

The power input graph will show a read-off of 0.7 kW at 1250 m³/h.

Every effort should be made to set a fan up to achieve the best useful effect possible.

1250 m³/hn1

Page 7: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

7

J

G

B

E

A

H

I

C

F

N

M

L

K

F a n t y p e s M T D 2 0 - M T D 4 0

MTD 20MTD 22MTD 25MTD 30MTD 35MTD 40

Dimensions

Type A B C D E F G H I J K L M N mm mm mm mm mm mm mm mm mm mm mm mm mm mm

6 positions. The position illustrations are viewed from the inlet side.

D

The direct drive centrifugal fan types MTD 20 - MTD 40 are designed for

material handling.

Equipped with self-cleaning impellers with backward-inclined blades

and aerodynamic intake. The impellers are statically and dynamically

balanced.

Max. operating temperature: 60°C

Number of blades are reduced by 2 for paper impeller.

Available in anti-spark version with stainless steel inlet and explosion-

proof (Eex) motor.

Dimensions (D) for the inlet are external. Supplied smooth.

Specific dimensions for the outlet flanges can be found under “Flanges”.

The technical data for each type appears on the following pages.

The blowers are as default delivered in position RV (LG270 according to

Eurovent).

Steel plate dimensions in mm

Type MTD 20 - MTD 30 MTD 35 - MTD 40

Impeller - standard 4 5 Impeller - reinforced 8 8 Fan housing - standard 3 3 Fan housing - reinforced 6 8

Weight without motor

kg

140166186206225251

140166186206225251

332930364555

200225250300350400

207220248267320330

448500582631670740

400475530577735795

141192210230360400

404050505050

317326356356390488

325340384415515500

198224273293293326

284310348377438462

500552618676770824

273445507388

RV(LG 270)

RN(LG 0)

RO(LG 90)

RNV(LG 315)

RNO(LG 45)

RSO(LG 135

LO(RD 270)

LN(RD 0)

LV(RD 90)

LNO(RD 315)

LNV(RD 45)

LSV(RD 135

Page 8: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

8

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

0.20.40.60.81.01.21.41.61.82.02.22.42.62.8

0.0

97

70

74

85

72 7475

dB(A)

dB(A)

0

20

40

60

80

100

120

140

160

180

0 500 1000 1500 2000 2500 3000

0 5 10 15 20 25 30 35 40 45 50

0

200

400

600

800

1000

1200

1400

1600 5063

6159

57

50 %

5948

60 %

0

20

40

60

80

100

120

140

160

180

0 500 1000 1500 2000 2500 3000

0 5 10 15 20 25 30 35 40 45 50

0

200

400

600

800

1000

1200

1400

1600 5063

6159

57

50 %

5948

60 %

Useful effect and pressure

Noise level and power input

F a n t y p e M T D 2 0Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3.200 min-1

Reinforced impeller: 2.840 min-1

Operating range:

Air volume: 750 - 1.800 m³/h

Pressure: 110 - 155 mmWG

Power supply:

230 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Variants:

Fan can be powered by flange motor

- type B5/B14.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø295 mm

Height: 114 mm

The blue curve applies for 6-bladed impeller.

Weight kW hp amp. of motor kg

1,1 1,5 4,3 10

N/m² mmWG

hp kW

m³/h

m³/min.

Air volume

2800 min-1

Useful effect

Total pressure pt

2800 min-1

Dynamic pressure pd

1400 min-1

1400 min-1

Page 9: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

9

0.00

0.50

1.00

1.50

2.00

2.50

3.00

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

93

73

91

74 71 72 dB(A)

dB(A)

0

20

40

60

80

100

120

140

160

180

200

220

0

200

400

600

800

1000

1200

1400

1600

1800

2000

2200

0 500 1000 1500 2000 2500 3000 3500 4000 4500

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

50

20 3029

20 %

64 63

63

55

50 %

0

20

40

60

80

100

120

140

160

180

200

220

0

200

400

600

800

1000

1200

1400

1600

1800

2000

2200

0 500 1000 1500 2000 2500 3000 3500 4000 4500

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

50

20 3029

20 %

64 63

63

55

50 %

Noise level and power input

Useful effect and pressure

F a n t y p e M T D 2 2Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3.200 min-1

Reinforced impeller: 2.865 min-1

Operating range:

Air volume: 1.000 - 3.100 m³/h

Pressure: 130 - 200 mmWG

Power supply:

230 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Variants:

Fan can be powered by flange motor

- type B5/B14.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø300 mm

Height: 139 mm

The blue curve applies for 6-bladed impeller.

Weight kW hp amp. of motor kg

2,2 3,0 8,0 14 2820 min-1

hp kW

1400 min-1

m³/h

m³/min.

N/m² mmWG

Air volume

Total pressure pt

Useful effect

2820 min-1

Dynamic pressure pd

1400 min-1

Page 10: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

10

0.0

1.0

2.0

3.0

4.0

5.0

6.0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

94

71 dB(A)

7072

72

76

82 dB(A)

020406080100120140160180200220240260280300

20040060080010001200140016001800200022002400260028003000

0

0 1000 2000 3000 4000 5000 6000

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100

50

22 26 22 %

5358

5955

5550 %

020406080100120140160180200220240260280300

20040060080010001200140016001800200022002400260028003000

0

0 1000 2000 3000 4000 5000 6000

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100

50

22 26 22 %

5358

5955

5550 %

Noise level and power input

Useful effect and pressure

F a n t y p e M T D 2 5Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3.200 min-1

Reinforced impeller: 2.865 min-1

Operating range:

Air volume: 1.500 - 4.500 m³/h

Pressure: 160 - 240 mmWG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Variants:

Fan can be powered by flange motor

- type B5/B14.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø360 mm

Height: 143 mm

The blue curve applies for 6-bladed impeller.

Weight kW hp amp. of motor kg

4,0 5,5 7,7 31

m³/h

m³/min.

N/m² mmWG

hp kW

Air volume

2880 min-1

1400 min-1

Total pressure pt

Useful effect

2880 min-1

Dynamic pressure pd

1400 min-1

Page 11: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

11

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

0

1

2

3

4

5

6

7

8

9

10

11

12

13

96

83 8081 dB(A)

81

80

89 dB(A)

020406080100120140160180200220240260280300320340360

50

31 48 41 40 %

5557

5755

50 %

2004006008001000120014001600180020002200240026002800300032003400

0

0 1000 2000 3000 4000 5000 6000 7000 8000 9000

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160

020406080100120140160180200220240260280300320340360

50

31 48 41 40 %

5557

5755

50 %

2004006008001000120014001600180020002200240026002800300032003400

0

0 1000 2000 3000 4000 5000 6000 7000 8000 9000

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160

Noise level and power input

Useful effect and pressure

F a n t y p e M T D 3 0Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3.200 min-1

Reinforced impeller: 2.895 min-1

Operating range:

Air volume: 2.500 - 6.500 m³/h

Pressure: 200 - 290 mmWG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Variants:

Fan can be powered by flange motor

- type B5/B14.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø410 mm

Height: 154 mm

The blue curve applies for 6-bladed impeller.

Weight kW hp amp. of motor kg

5,5 7,5 11,1 43

7,5 10,0 14,7 49

m³/h

m³/min.

N/m² mmWG

Air volume

kW

2860 min-1

1400 min-1

Total pressure pt

Useful effect

2860 min-1

Dynamic pressure pd

1400 min-1

Page 12: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

12

0

1

2

3

4

5

6

7

8

9

10

11

012

34567

89101112131415

103

95

84

86

70 71 69 dB(A)

101 dB(A

0

50

100

150

200

250

300

350

400

450

500

0 1 2 3 4 5 6 7 8 9

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

50 5664

6361

6050 %

35 4138 %

x 100

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

0

50

100

150

200

250

300

350

400

450

500

0 1 2 3 4 5 6 7 8 9

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

50 5664

6361

6050 %

35 4138 %

x 100

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

Noise level and power input

Useful effect and pressure

F a n t y p e M T D 3 5Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3.200 min-1

Reinforced impeller: 2.915 min-1

Operating range:

Air volume: 3.000 - 8.500 m³/h

Pressure: 260 - 375 mmWG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Variants:

Fan can be powered by flange motor

- type B5/B14.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø450 mm

Height: 185 mm

The blue curve applies for 6-bladed impeller.

Weight kW hp amp. of motor kg

11,0 15,0 21,2 69

15,0 20,0 28,2 83

m³/h

m³/min.

Air volume

mmWG

hp kW

2920 omdr./min.

Total pressure pt

Useful effect

Dynamic pressure pd

N/m²

1400 min-1

2920 min-1

1400 min-1

x1000

Page 13: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

13

024681012141618202224262830

10196

82

98dB(A

)

83 8072

dB(A)

2468

141618202224

30323436

40

0

1012

2628

38

04080120160200240280320360400440480520560600

5058 59 63 60

5550 %

33 4950

45 %4008001200160020002400280032003600400044004800520056006000

0

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 20 40 60 80 100 120 140 160 180 200 220 240 260

x 100

04080120160200240280320360400440480520560600

5058 59 63 60

5550 %

33 4950

45 %4008001200160020002400280032003600400044004800520056006000

0

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 20 40 60 80 100 120 140 160 180 200 220 240 260

x 100

Noise level and power input

Useful effect and pressure

F a n t y p e M T D 4 0Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3.200 min-1

Reinforced impeller: 2.930 min-1

Operating range:

Air volume: 5.000 - 11.000 m³/h

Pressure: 340 - 440 mmWG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Variants:

Fan can be powered by flange motor

- type B5/B14.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø500 mm

Height: 185 mm

The blue curve applies for 6-bladed impeller.

Weight kW hp amp. of motor kg

18,5 25,0 34,4 87

22,0 30,0 40,0 165

m³/h

m³/min.

Air volume

hp kW

Total pressure pt

Useful effect

Dynamic pressure pd

2920 min-1

2920 min-1

N/m² mmWG

1400 min-1

1400 min-1

x1000

Page 14: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

14

F

NM

L

K

D

J

G

B

EA

H

I

C

H

F a n t y p e s M T K 4 0 - M T K 7 5

MTK 40MTK 45MTK 55MTK 75

250339418700

250339418550

55556060

400450550750

330395500442

740885

10951310

1110120715401875

494528700855

55555970

550672825850

650720955

1125

326375468600

462570715800

824101312501410

200300532597

Dimensions

Type A B C D E F G H I J K L M N mm mm mm mm mm mm mm mm mm mm mm mm mm mm

The indirect drive centrifugal fan types MTK 40 - MTK 75 are designed for

material handling.

Equipped with self-cleaning impellers with backward-inclined blades

and aerodynamic intake. The impellers are statically and dynamically

balanced.

The pulleys are shaft-mounted with taperlock bushing, allowing easy

replacement for changed fan speed.

Max. operating temperature: 60°C

With cooling wings: Up to 200°C

Number of blades are reduced by 2 for paper impeller.

Available in anti-spark version with stainless steel inlet and explosion-

proof (Eex) motor.

Dimensions (D) for the inlet are external. Supplied smooth.

Belt drive is anti-static.

Specific dimensions for the outlet flanges can be found under “Flanges”.

The technical data for each type appears on the following pages.

The blowers are as default delivered in position RV (LG270 according to

Eurovent).

RV(LG 270)

RN(LG 0)

RO(LG 90)

RNV(LG 315)

RNO(LG 45)

RSO(LG 135

LO(RD 270)

LN(RD 0)

LV(RD 90)

LNO(RD 315)

LNV(RD 45)

LSV(RD 135

6 positions. The position illustrations are viewed from the inlet side.

Steel plate dimensions in mm

Weight without motor

kg

Type MTK 40/45 MTK 55 MTK 75 Impeller - standard 5 6 Impeller - reinforced 8 8 8 Fan housing - standard 3 4 Fan housing - reinforced 8 8

Page 15: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

15

0

2

4

6

8

10

12

14

16

18

20

22

24

0246810121416182022242628303234

105

86

101 dB(A

)

3200 min-1

3000 min-1

2800 min-1

2600 min-1

2400 min-1

2200 min-1

1800 min-1

F a n t y p e M T K 4 0 Te c h n i c a l d a t a

04080120160200240280320360400440480520560600

5061

63 6362

6160

50 %

4008001200160020002400280032003600400044004800520056006000

0

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 20 40 60 80 100 120 140 160 180 200 220 240 260

x 100

04080120160200240280320360400440480520560600

5061

63 6362

6160

50 %

4008001200160020002400280032003600400044004800520056006000

0

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 20 40 60 80 100 120 140 160 180 200 220 240 260

x 100m³/h

m³/min.

Air volume

Noise level and power input

Useful effect and pressure

Useful effect

2600 min-1 2800 min-1

3000 min-1 3200 min-1

2400 min-1

Dynamic pressure pd

2200 min-1

1800 min-1

N/m² mm WG

hp kW

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3,435 min-1

Reinforced impeller: 2,600 min-1

Operating range:

Air volume: 5,000 – 11,000 m³/h

Pressure: 140 – 540 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø500 mm

Height: 189 mm

Weight kW hp amp. of motor kg

11,0 15,0 21,2 69

15,0 20,0 28,2 83

x1000

Page 16: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

16

0

4

8

12

16

20

24

28

32

36

40

44

48

52

56

60

64

115

86

90

110dB(A)

04812162024283236404448525660646872768084

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

0 50 100 150 200 250 300 350 400 450 500

x 100

50 57 6363

6158

5655

50 %

04080120160200240280320360400440480520560600

4008001200160020002400280032003600400044004800520056006000

0

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

0 50 100 150 200 250 300 350 400 450 500

x 100

50 57 6363

6158

5655

50 %

04080120160200240280320360400440480520560600

4008001200160020002400280032003600400044004800520056006000

0

Noise level and power input

Useful effect and pressure

F a n t y p e M T K 4 5Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 2.450 min-1

Reinforced impeller: 1.850 min-1

Operating range:

Air volume: 6.000 - 20.000 m³/h

Pressure: 180 - 520 mmWG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø650 mm

Height: 259 mm

The blue curve applies for 6-bladed impeller

and at 1950 min-1.

Weight kW hp amp. of motor kg

18,5 25,0 34,4 87

22,0 30,0 40,0 165

30,0 40,0 52,5 240

m³/h

m³/min.

N/m² mmWG

hp kW

2350 min-1

2250 min-1

2150 min-1

2050 min-1

1950 min-1

1850 min-1

1750 min-1

1650 min-1

Total pressure pt

Useful effect

2050 min-12150 min-12250 min-12350 min-1

1950 min-1

Dynamic pressure pd

1850 min-1

1750 min-1

1650 min-1

Air volume

x1000

Page 17: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

17

0

5

10

15

20

25

30

35

40

45

50

55

60

65

0510152025303540455055606570758085

x 100

04080120160200240280320360400440480520560600640

040080012001600200024002800320036004000440048005200560060006400

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

x 100

04080120160200240280320360400440480520560600640

040080012001600200024002800320036004000440048005200560060006400

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

Noise level and power input

Useful effect and pressure

F a n t y p e M T K 5 5Te c h n i c a l d a t a

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 2.050 min-1

Reinforced impeller: 2.050 min-1

Operating range:

Air volume: 8.000 - 29.000 m³/h

Pressure: 160 - 600 mmWG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø800 mm

Height: 320 mm

The blue curve applies for 6-bladed impeller

and at 1850 min-1.

Weight kW hp amp. of motor kg

30,0 40,0 53 230

37,0 50,0 67 300

45,0 60,0 80 330

55,0 75,0 97 435

m³/h

m³/min.

N/m² mmWG

Air volume

90

1032050 min-1

2050 min-1

Useful effect

Total pressure pt

Dynamic pressure pd

1950 min-1

1850 min-1

1750 min-1

1650 min-1

1550 min-1

1450 min-1

1350 min-1

1200 min-1

1950 min-1

1850 min-1

1750 min-1

1650 min-1

1550 min-1

1450 min-1

1350 min-1

1200 min-1

dB(A)

88

90

116

5055

6363

6458

56

50 %

67

hp kW

x1000

Page 18: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

18

00

20

30

40

102030405060

10

50

60

70

80

90

100

708090100110120130

118

97

115dB(A)

F a n t y p e M T K 7 5 Te c h n i c a l d a t a

0

0

0

0

50

100

150

500

1000

1500

5 10 15 20 25

1 2 3 4

30 35 40 45 50 55 60 65 70 75 x 100

105 6 7 8 9 11 12 x 100

200

250

300

350

400

450

2000

2500

3000

3500

4000

4500

5000 500

550 5500

5056

5850 %

0

0

0

0

50

100

150

500

1000

1500

5 10 15 20 25

1 2 3 4

30 35 40 45 50 55 60 65 70 75 x 100

105 6 7 8 9 11 12 x 100

200

250

300

350

400

450

2000

2500

3000

3500

4000

4500

5000 500

550 5500

5056

5850 %

m³/h

m³/min.

Air volume

Noise level and power input

Useful effect and pressure

hp kW

1650 min-1

1450 min-1

1350 min-1

1250 min-1

Total pressure pt

Useful effect

1250 min-1

1550 min-1 1450 min-1 1350 min-1

1650 min-1

Dynamic pressure pd

1550 min-1

N/m² mm WG

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 2,050 min-1

Reinforced impeller: 1,450 min-1

Operating range:

Air volume: 25,000 – 40,000 m³/h

Pressure: 200 – 370 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø890 mm

Height: 430 mm

Weight kW hp amp. of motor kg

55,0 75,0 97,0 435

75,0 103,0 133,0 610

x1000

Page 19: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

19

N

D

F

LK

M

J

E

D

G

H1

I

C

H2

N

D

F

LK

M

J

E

D

G

H1

I

C

H2

J

E

G

C

H1

IH

2

D

RV(LG 270)

RN(LG 0)

RO(LG 90)

RNV(LG 315)

RNO(LG 45)

RSO(LG 135

LO(RD 270)

LN(RD 0)

LV(RD 90)

LNO(RD 315)

LNV(RD 45)

LSV(RD 135

F a n t y p e B T D / B P D / B T K / B P K 2 0 0 - 5 0 0

6 positions. The position illustrations are viewed from the inlet side.

The indirect driven centrifugal fan types BTK/BPK 200 - 500 and direct

driven fan types BTD/BPD 200 - 500 is designed for concentrated

material handling over long distances.

The impellers are available in 2 versions, an open T-impeller for

coarse-grained or rather long material types and a closed P-impeller for

dust particles (< 2 mm).

The impeller for paper is always made as open T-impeller with 6

blades.

T-impeller is available in wear-resistant material HARDOX.

The impeller is statically and dynamically balanced.

The fan is available in anti-spark version with stainless steel inlet and

explosion-proof (Eex) motor.

The pulleys are fitted with taperlock. This means that they can be

easily re-placed if the number of revolutions has to be changed.

Max. operating temperature: 60°C

With cooling wings: Up to 200°C (only K-models)

Dimensions (D) for the inlet are external, and is supplied smooth on

T-D

BTD/BPD/ BTK/BPK 200 - 300 and with flange on BTD/BPD/ BTK/

BPK 400 - 500.

Specific dimensions for the outlet flanges can be found under “Flanges”.

The technical data for each type appears on the following pages.

Effects measured according to ISO 5801.

The blowers are as default delivered in position RV (LG270 according to

Eurovent).

Dimensions

Type C D E F G H1 H2 I J K L M N mm mm mm mm mm mm mm mm mm mm mm mm mm

10075

10621510075

106215

200300400500200300400500

352380514522352380514522

896107612121361896

107612121361

1099125514361668934

111012081535

506584676792305366398450

4242424238383737

671786850932671760850850

720860

10081193

720860

10081193

496591588693496591588693

257371627677219328529646

454533716774454533716774

834971

12731366

834971

12731366

BTK/BPK 200BTK/BPK 300BTK/BPK 400BTK/BPK 500BTD/BPD 200BTD/BPD 300BTD/BPD 400BTD/BPD 500

506584676792545660726

1001

Weight without motor

kg

T-D/K T-K

Page 20: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

20

0

2

4

6

8

10

12

14

16

18

20

22

24

26

0

5

10

15

20

25

30

35

40Lw D,cas(A)[dB(A)]96

94

93

91

90

88

f[Hz]50

47

44

41

38

35

n[min.-1]2940

2760

2615

2420

2250

2085

31%

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

0 50 100 150

0

1000

2000

3000

4000

5000

6000

7000

800044%

46%

40%

34%

Pd

ηtotal

Lw Do(A)[dB(A)]120119118116115113

f[Hz]504744413835

n[min.-1]294027602615242022502085

050100150200250300350400450500550600650700750800 40

48

50

44

40 %

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

0 50 100 150

0500100015002000250030003500400045005000550060006500700075008000

10000

F a n t y p e B T K 2 0 0 a n d B T D 2 0 0 Te c h n i c a l d a t a

Motor: IP 55

Fan BTK 200

Supplied with the following motors:

Fan BTD 200

Supplied with the following motors:

Max. min-1:

Standard impeller: 2.940 min.-1

Reinforced impeller: 2.850 min.-1

Operating range T-impeller:

Air volume: 800 - 5.200 m³/h

Pressure: 2.150 - 7.850 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BTK 200:

B3 - motor mounted on foot.

Construction BTD 200:

B35 - motor mounted with food and flange.

T-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø650 mm

Height: 120 mm

Weight kW amp. of motor kg 15,0 27,5 83

18,5 34,4 87

22,0 40,0 165

Weight kW amp. of motor kg 15,0 27,5 83

18,5 34,4 87

22,0 39,0 180

m³/h

m³/min.

Air volume

T-impellerPe[kW]

Pt[Pa]

LwDo(A) = channel noise measured on outlet according to ISO 13347

LwD,(A) = casing noise (motor, belts, etc.)

Total pressure pt

Noise level and power input

Useful effect and pressure

Page 21: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

21

0

2

4

6

8

10

12

14

0

5

10

15

20

25

30

35

40

Lw D,cas(A)[dB(A)]94

92

91

89

88

86

f[Hz]50

47

44

41

38

35

n[min.-1]2940

2760

2615

2420

2250

2085

49%

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

0 50 100 150

0

1000

2000

3000

4000

5000

6000

7000

8000

900067%

75%75%

74%

Pd

ηtotal

Lw Do(A)[dB(A)]112111109108106104

f[Hz]504744413835

n[min.-1]294027602615242022502085

70%

66%61%56%50%

Pt

050100150200250300350400450500550600650700750800 40

48

50

44

40 %

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

0 50 100 150

0500100015002000250030003500400045005000550060006500700075008000

10000

T-impeller

F a n t y p e B P K 2 0 0 a n d B P D 2 0 0Te c h n i c a l d a t a

m³/h

m³/min.

Air volume

Noise level and power input P-impeller

Useful effect and pressure

Pe[kW]

Motor: IP 55

Fan BPK 200

Supplied with the following motors::

Fan BPD 200

Supplied with the following motors:

Max. min-1:

Impeller: 2.940 min.-1

Operating range P-impeller:

Air volume: 1.000 - 6.500 m³/h

Pressure: 1.850 - 8.350 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BPK 200:

B3 - motor mounted on foot.

ConstructionBPD 200:

B35 - motor mounted with food and flange.

P-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø654 mm

Height: 131 mm

Weight kW amp. of motor kg 15,0 27,5 83

18,5 34,4 87

22,0 40,0 165

Weight kW amp. of motor kg 15,0 27,5 83

18,5 34,4 87

22,0 39,0 180

Pt[Pa]

LwDo(A) = channel noise measured on outlet according to ISO 13347

LwD,(A) = casing noise (motor, belts, etc.)

Total pressure pt

Page 22: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

22

20

10

0

50

60

70

40

30

Lw D,cas(A)[dB(A)]105

103

102

100

99

96

f[Hz]50

47

45

40

38

34

n[min.-1]2950

2790

2645

2370

2215

2000

1000

2000

3000

0

10000

4000

5000

6000

7000

8000

9000

11000

0 1 2 3 4 5

2 4 6 80

6 7 8 9 10 11 12 13 14 15

10 2012 14 16 18 22 24

16 17 18 x 1000

30 x 10 26 28

33%42%

49%50%

52%

50%

45%

Lw Do(A)[dB(A)]125123122120118116

f[Hz]504745403834

n[min.-1]295027902645237022152000

Pt

ηtotal

Pd

0 1 2 3 4 5

100

0

300

200

2 4 6 80

1000

2000

3000

0

6 7 8 9 10 11 12 13 14 15

10 2012 14 16 18 22 24

16 17 18 x 10

30 x 10 26 28

800

700

600

500

400

900

10000

4000

5000

6000

7000

8000

90001000

11001100050

5552

50 %

x1000

Pe[kW]

Pt[Pa]

Motor: IP 55

FanBTK 300

Supplied with the following motors:

Fan BTD 300

Supplied with the following motors:

Max. min-1:

Standard impeller: 2.940 min.-1

Reinforces impeller: 2,400 min.-1

Operating range T-impeller:

Air volume: 2.000 - 11.000 m³/h

Pressure: 3.500 - 10.800 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BTK 300:

B3 - motor mounted on foot.

Construction BTD 300:

B35 - motor mounted with food and flange.

T-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø735 mm

Height: 130 mm

Weight kW amp. of motor kg 22,0 39,0 180

30,0 52,3 246

37,0 64,5 256

45,0 78,0 328

F a n t y p e B T K 3 0 0 a n d B T D 3 0 0Te c h n i c a l d a t a

m³/h

m³/min.

Air volume

Noise level and power input

Useful effect and pressure

T-impeller

LwDo(A) = channel noise measured on outlet according to ISO 13347

LwD,(A) = casing noise (motor, belts, etc.)

Total pressure pt

Weight kW amp. of motor kg 30,0 52,3 246

37,0 64,5 256

45,0 78,0 328

Page 23: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

23

0

5

10

15

20

25

30

35

40

45

50

55

60

Lw D,cas(A)[dB(A)]101

99

98

96

95

92

f[Hz]50

47

45

40

38

34

n[min.-1]2950

2790

2645

2370

2215

2000

0 1 2 3 4 5

2 4 6 80

1000

2000

3000

0

6 7 8 9 10 11 12 13 14 15

10 2012 14 16 18 22 24

16 17 18 x 1000

30 x 10 26 28

10000

4000

5000

6000

7000

8000

9000

11000

12000

Pd

41% 52% 65%65%

63%

62%

59%

51%

41%

Pt

ηtotal

Lw Do(A)[dB(A)]116115114111110108

f[Hz]504745403834

n[min.-1]295027902645237022152000

0 1 2 3 4 5

100

0

300

200

2 4 6 80

1000

2000

3000

0

6 7 8 9 10 11 12 13 14 15

10 2012 14 16 18 22 24

16 17 18 x 10

30 x 10 26 28

800

700

600

500

400

900

10000

4000

5000

6000

7000

8000

90001000

11001100050

5552

50 %

x1000

T-impeller

Motor: IP 55

Fan BPK 300

Supplied with the following motors:

Fan BPD 300

Supplied with the following motors:

Max. min-1:

Impeller: 2.950 min.-1

Operating range P-impeller:

Air volume: 2.000 - 14.000 m³/h

Pressure: 2.500 - 10.800 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BPK 300:

B3 - motor mounted on foot.

Construction BPD 300:

B35 - motor mounted with food and flange.

P-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø740 mm

Height: 177 mm

Weight kW amp. of motor kg 22,0 39,0 180

30,0 52,3 246

37,0 64,5 256

45,0 78,0 328

F a n t y p e B P K 3 0 0 a n d B P D 3 0 0Te c h n i c a l d a t a

m³/h

m³/min.

Air volume

Noise level and power input

Useful effect and pressure

P-impellerPe[kW]

Pt[Pa]

LwDo(A) = channel noise measured on outlet according to ISO 13347

LwD,(A) = casing noise (motor, belts, etc.)

Total pressure pt

Weight kW amp. of motor kg 30,0 52,3 246

37,0 64,5 256

45,0 78,0 328

Page 24: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

24

8000

6000

4000

2000

0

10000

12000

14000

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 x 1000

0 4 8 12 16 20 24 28 32 36 40 44 48 52 x 10

Pd

Pt

ηtotal

Lw Do(A)[dB(A)]131130129127125123

f[Hz]504744423734

n[min.-1]295527802610247522102005

30%44% 45%

53%48%

46%

46%

0

20

30

10

4 8 12 160 20 4024 28 32 36 44 48 60 x 10 52 56

80

90

60

70

40

50

100

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 x 1000

Lw D,cas(A)[dB(A)]115

113

112

111

108

106

f[Hz]50

47

44

42

37

34

n[min.-1]2955

2780

2610

2475

2210

2005

8000

6000

4000

2000

0

10000

12000

14000

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 x 1000

0 4 8 12 16 20 24 28 32 36 40 44 48 52 x 10

Pd

Pt

ηtotal

Lw Do(A)[dB(A)]131130129127125123

f[Hz]504744423734

n[min.-1]295527802610247522102005

30%44% 45%

53%48%

46%

46%

x1000

F a n t y p e B T K 4 0 0 a n d B T D 4 0 0Te c h n i c a l d a t a

m³/h

m³/min.

Air volume

Motor: IP 55

Fan BTK 400

Supplied with the following motors:

Fan BTD 400

Supplied with the following motors:

Max. min-1:

Impeller: 2.955 min.-1

Operating range T-impeller:

Air volume: 2.500 - 17.000 m³/h

Pressure: 3.500 - 11.700 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BTK 400:

B3 - motor mounted on foot.

Construction BTD 400:

B35 - motor mounted with food and flange.

T-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø786 mm

Height: 199 mm

Noise level and power input

Useful effect and pressure

T-impellerPe[kW]

Pt[Pa]

LwDo(A) = channel noise measured on outlet according to ISO 13347

LwD,(A) = casing noise (motor, belts, etc.)

Total pressure pt

Weight kW amp. of motor kg 37,0 65,9 305

45,0 78,0 328

55,0 95,4 452

75,0 129,0 592

Weight kW amp. of motor kg 55,0 95,4 452

75,0 129,0 592

Page 25: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

25

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 x 1000

0 4 8 12 16 20 24 28 32 36 40 44 48 52 x 10

8000

6000

4000

2000

0

10000

12000

14000

Pd

Pt

ηtotal

Lw Do(A)[dB(A)]123122120119117115

f[Hz]504744423734

n[min.-1]295527802610247522102005

47%45% 54%

70%

68%

63%

43%

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 x 1000

0 4 8 12 16 20 24 28 32 36 40 44 48 52 x 10

80

70

60

50

40

30

20

10

0

Lw D,cas(A)[dB(A)]105

103

102

101

98

96

f[Hz]50

47

44

42

37

34

n[min.-1]2955

2780

2610

2475

2210

2005

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 x 1000

0 4 8 12 16 20 24 28 32 36 40 44 48 52 x 10

80

70

60

50

40

30

20

10

0

Lw D,cas(A)[dB(A)]105

103

102

101

98

96

f[Hz]50

47

44

42

37

34

n[min.-1]2955

2780

2610

2475

2210

2005

x1000

T-impeller

F a n t y p e B P K 4 0 0 a n d B P D 4 0 0Te c h n i c a l d a t a

Motor: IP 55

Fan BPK 400

Supplied with the following motors:

Fan BPD 400

Supplied with the following motors:

Max. min-1:

Impeller: 2.955 min.-1

Operating range P-impeller::

Air volume: 4.000 - 23.000 m³/h

Pressure: 2.200 - 11.000 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BPK 400:

B3 - motor mounted on foot.

Construction BPD 400:

B35 - motor mounted with food and flange.

P-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø769 mm

Height: 240 mm

m³/h

m³/min.

Air volume

Noise level and power input

Useful effect and pressure

P-impellerPe[kW]

Pt[Pa]

LwD,(A) = casing noise (motor, belts, etc.)

LwDo(A) = channel noise measured on outlet according to ISO 13347

Total pressure pt

Weight kW amp. of motor kg 37,0 65,9 305

45,0 78,0 328

55,0 95,4 452

75,0 129,0 592

Weight kW amp. of motor kg 55,0 95,4 452

75,0 127,0 592

Page 26: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

26

4 8 12 160 20 4024 28 32 36 44 48 62 x 10 52 56 58 60

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 x 1000

Pd

33%

Pt

ηtotal

Lw Do(A)[dB(A)]135133132130128126

f[Hz]504744423733

n[min.-1]295527802615249022201970

38%49%

54%

55%

46%8000

6000

4000

2000

0

10000

12000

14000

0

40

60

20

160

180

120

140

100

80

4 8 12 160 20 4024 28 32 36 44 48 62 x 10 52 56 58 60

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 x 1000

Lw D,cas(A)[dB(A)]119

117

116

115

112

109

f[Hz]50

47

44

42

37

33

n[min.-1]2955

2780

2615

2490

2220

1970

0

40

60

20

160

180

120

140

100

80

4 8 12 160 20 4024 28 32 36 44 48 62 x 10 52 56 58 60

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 x 1000

Lw D,(A) = Casing støj (motor, remme osv.)

Lw D,cas(A)[dB(A)]119

117

116115

112

109

f[Hz]50

47

4442

37

33

n[min.-1]2955

2780

26152490

2220

1970

x1000

F a n t y p e B T K 5 0 0 a n d B T D 5 0 0Te c h n i c a l d a t a

Motor: IP 55

Fan BTK 500

Supplied with the following motors::

Fan BTD 500

Supplied with the following motors::

Max. min-1:

Impeller: 2.955 min.-1

Operating range T-impeller:

Air volume: 3.000 - 25.000 m³/h

Pressure: 3.700 - 12.800 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BTK 500:

B3 - motor mounted on foot.

Construction BTD 500:

B35 - motor mounted with food and flange.

T-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø805 mm

Height: 250 mm

Weight kW amp. of motor kg 75,0 129,0 592

90,0 155,0 672

110,0 189,0 980

Air volume

Noise level and power input

Useful effect and pressure

T-impeller

m³/h

m³/min.

Pe[kW]

Pt[Pa]

LwDo(A) = channel noise measured on outlet according to ISO 13347

LwD,(A) = casing noise (motor, belts, etc.)

Total pressure pt

Weight kW amp. of motor kg 75,0 129,0 592

90,0 155,0 672

110,0 185,0 950

Page 27: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

27

Pd

48%

Pt

ηtotal

Lw Do(A)[dB(A)]127126125124121119

f[Hz]504744423733

n[min.-1]295527802615249022201970

58% 63%68%

65%

64%

60%

53%

42%

8000

6000

4000

2000

0

10000

12000

14000

4 8 12 160 20 4024 28 32 36 44 48 62 x 10 52 56 58 60

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 x 1000

0

40

60

20

120

100

80

4 8 12 160 20 4024 28 32 36 44 48 62 x 10 52 56 58 60

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 x 1000

Lw D,cas(A)[dB(A)]112

110

109

108

105

102

f[Hz]50

47

44

42

37

33

n[min.-1]2955

2780

2615

2490

2220

1970

0

40

60

20

160

180

120

140

100

80

4 8 12 160 20 4024 28 32 36 44 48 62 x 10 52 56 58 60

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 x 1000

Lw D,(A) = Casing støj (motor, remme osv.)

Lw D,cas(A)[dB(A)]119

117

116115

112

109

f[Hz]50

47

4442

37

33

n[min.-1]2955

2780

26152490

2220

1970

x1000

T-impeller

F a n t y p e B P K 5 0 0 a n d B P D 5 0 0Te c h n i c a l d a t a

Air volume

Noise level and power input

Useful effect and pressure

P-impeller

Motor: IP 55

Fan BPK 500

Supplied with the following motors:

Fan BPD 500

Supplied with the following motors:

Max. min-1:

Impeller: 2.955 min.-1

Operating range P-impeller:

Air volume: 5.000 - 37.000 m³/h

Pressure: 1.000 - 11.700 Pa

Power supply:

3 x 400 V - 50 Hz.

Construction BPK 500:

B3 - motor mounted on foot.

Construction BPD 500:

B35 - motor mounted with food and flange.

P-impeller:

No. of blades, standard: 8 pcs.

Diameter: ø805 mm

Height : 285 mm

Weight kW amp. of motor kg 75 129 592

90 155 672

110 189 980

Weight kW amp. of motor kg 75 129 592

90 155 672

110 185 950

Pe[kW]

m³/h

LwD,(A) = casing noise (motor, belts, etc.)

LwDo(A) = channel noise measured on outlet according to ISO 13347

Total pressure pt

Page 28: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

28

N

M

L

K

F

D

J

C

H

B

A

E

H

I

G

N

M

L

K

F

D

J

C

H

B

A

E

H

I

G

RV(LG 270)

RN(LG 0)

RO(LG 90)

RNV(LG 315)

RNO(LG 45)

RSO(LG 135

LO(RD 270)

LN(RD 0)

LV(RD 90)

LNO(RD 315)

LNV(RD 45)

LSV(RD 135

Fan types MCD 30 – MCD 40 – MCD 50

6 positions. The position illustrations are viewed from the inlet side.

The direct drive centrifugal fan types MCD 30, MCD 40 and MCD 50 are

designed for transport of clean air.

Equipped with backward-inclined blades and aerodynamic intake.

The impellers are statically and dynamically balanced according to ISO

10816-3.

Normally, a frequency transformer is used to control the min-1 and the air

volume of the fan.

Max. operating temperature: 60°C

The inlet (D) is supplied with flange as standard.

Specific dimensions for the outlet and inlet flanges can be found under

“Flanges”.

Available in anti-spark version with stainless steel inlet and explosion

proof (Eex) motor.

The technical data for each type appears on the following pages.

The blowers are as default delivered in position RV (LG270 according to

Eurovent).

Dimensions

TypeA

mmB

mmC

mmD

mmE

mmF

mmG

mmH

mmI

mmJ

mmK

mmL

mmM

mmN

mm

Weightwithoutmotor

kgMCD 30 250 250 106 300 318 645 733 275 51 430 550 276 450 768 37MCD 40 350 350 106 400 368 779 903 370 49 550 650 326 550 1098 119MCD 50 450 450 106 500 416 1012 1128 370 199 672 750 436 643 1146 206

Page 29: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

29

0

1

2

3 88

81 65 79 dB(A)

69 4

5

6

7

8

8567 dB(A)

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

1 2

25

3 4

100 125 150

5 6 7 8 9

50 75

10 x 100

5472

520560

52005600

7472

66

2028 30

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

1 2

25

3 4

100 125 150

5 6 7 8 9

50 75

10 x 100

5067

520560

52005600

7368

50 %

20 2830 %

7,8 45

F a n t y p e M C D 3 0Te c h n i c a l d a t a

m³/h

m³/min.

Pa mm WG

Air volume

Noise level and power input

Useful effect and pressure

kW

2900 min-1

1450 min-1

1450 min-1

Total pressure pt

Useful effect

Dynamic pressure pd

2900 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Impeller: 3,575 min-1

Operating range:

Air volume: 2,000 – 6,000 m³/h

Pressure: 120 – 330 mm WG

Power supply:

230/400 V

Construction:

B3 – motor mounted on foot.

Variants:

Fan can be powered by flange motor –

Type B5/B14

Impeller:

No. of blades, standard: 6 pcs.

Diameter: ø424 mm

Height: 171 mm

Weight 50 Hz 60 Hz amp. of motor kg

4,0 kW

2880 min-1

4,8 kW

3456 min-1

x1000

Page 30: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

30

0 1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

9

92

88 69 85 dB(A)

7372 88 dB(A)

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

2 4

50

6 8 10 12 14 16 18

200100 300150 250

20 x 10

5156

72

76

72

3545

3735 %

6550 %

520560

52005600

76

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

2 4

50

6 8 10 12 14 16 18

200100 300150 250

20 x 10

50 5569

78

77

72

3545

3735 %

60

50 %

520560

52005600

20,2 102

F a n t y p e M C D 4 0Te c h n i c a l d a t a

m³/h

m³/min.

Pa mm WG

Air volume

Noise level and power input

Useful effect and pressure

kW

2900 min-1

1450 min-1

1450 min-1

Total pressure pt

Useful effect

Dynamic pressure pd

2900 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Impeller: 3,575 min-1

Operating range:

Air volume: 2,500 – 14,000 m³/h

Pressure: 120 – 460 mm WG

Power supply:

400/690 V

Construction:

B3 – motor mounted on foot.

Impeller:

No. of blades, standard: 6 pcs.

Diameter: ø515 mm

Height: 196 mm

Weight 50 Hz 60 Hz amp. of motor kg

13,2 kW

3528 min-1

11 kW

2940 min-1

x1000

Page 31: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

31

0

5

10

15

20

25

30

88

8479

7674 78 82

87

8582 84 88dB(A)

22,0 kW

18,5 kWdB(A)

0

100

200

300

400

0

0

500

600

2 4

50

6 8 10 12 14 16 18

200100 300150 250

20 x 1000

700

35

3758

8388

83

73%

5864

70

69

66%

18,5 kW

22,0 kW

0

1000

2000

3000

4000

5000

6000

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

2 4

50

6 8 10 12 14 16 18

200100 300150 250

20 x 10

50 5569

78

77

72

3545

3735 %

60

50 %

520560

52005600

136

158

33,0

39,2

F a n t y p e M C D 5 0Te c h n i c a l d a t a

m³/h

m³/min.

mm WG

Air volume

Noise level and power input

Useful effect and pressure

kW

2900 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Impeller: 3,575 min-1

Operating range:

Air volume: 2,500 – 22,000 m³/h

Pressure: 160 – 590 mm WG

Power supply:

400/690 V

Construction:

B3 – motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø574/608 mm

Height: 227/224 mm

Pa

Total pressure pt

Useful effect

Dynamic pressure pd

2900 min-1

2900 min-1

2900 min-1

Weight 50 Hz 60 Hz amp. of motor kg

22,2 kW

26,4 kW

3528 min-1

18,5 kW

22,0 kW

2940 min-1

x1000

Page 32: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

32

N

M

L

F

K

D

B

C

G

H

H

A

E

J I

F a n t y p e s M C K 4 0 - M C K 1 0 0

350455505605705805905

350455505605705805905

75757575757575

400500600700800900

1000

368418543593643723793

775100011861360149016701865

494587700855905

10301080

5555 597070

100100

550672825850850

10701070

650750955

1125112513251425

550650800900

100011301250

925115014001570172719402175

Dimensions

Type A B C D E F G H I J K L M N mm mm mm mm mm mm mm mm mm mm mm mm mm mm

RV(LG 270)

RN(LG 0)

RO(LG 90)

RNV(LG 315)

RNO(LG 45)

RSO(LG 135

LO(RD 270)

LN(RD 0)

LV(RD 90)

LNO(RD 315)

LNV(RD 45)

LSV(RD 135

6 positions. The position illustrations are viewed from the inlet side.

The indirect drive centrifugal fan types MCK 40 - MCK 100 are

designed for transport of clean air.

Equipped with self-cleaning impellers with backward-inclined

blades and aerodynamic intake. The impellers are statically and

dynamically balanced.

The pulleys are shaft-mounted with taperlock bushing, allowing

easy replacement for changed fan speed.

Max. operating temperature: 60°C

With cooling wings: Up to 200°C

Available in anti-spark version with stainless steel inlet and explosion-

proof (Eex) motor.

Dimensions (D) for the inlet are external. Supplied with flange as standard.

Belt drive is anti-static.

Specific dimensions for outlet and inlet flanges can be found under “Flanges”.

The technical data for each type appears on the following pages.

The blowers are as default delivered in position RV (LG270 according

to Eurovent).

Weight without motor

kg

Steel plate dimensions in mm

Type MCK 40/MCK 60 MCK 70/MCK 90 MCK 100

Impeller - standard 3 4 5 Fan housing - standard 3 3 3

MCK 40MCK 50MCK 60MCK 70MCK 80MCK 90MCK 100

1128132815631895199523102410

325436486566625700770

226343554703788

11891295

Page 33: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

33

0

400

800

1200

1600

2000

2400

2800

3200

3600

4000

4400

4800

5200

5600

6000

6400

0

40

80

120

160

200

240

280

320

360

400

440

480

520

560

600

640

0 2 4 6 8 10 12 14 16 18 20 22 x 1000

0 50 200100 300150 250 350

5068

73

76

79

68

50 %

0 1 2 3 4 5 6 7 8 91011121314151617181920212223

0 1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17

9

96

8078 76 91 dB(A)

2900 min-1

3100 min-1

3300 min-1

3500 min-1

2700 min-1

2500 min-1

2300 min-1

2900 min-13100 min-1

3300 min-13500 min-1

2700 min-1

2500 min-1

2300 min-1 0 400 80012001600200024002800320036004000440048005200560060006400

0 40 80120160200240280320360400440480520560600640

0 2 4 6 8 10 12 14 16 18 20 22 x 100

0 50 200100 300150 250 350

5068

73

76

79

68

50 %

x1000

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 3,435 min-1

Operating range:

Air volume: 4,500 - 17,000 m³/h

Pressure: 100 - 450 mmWG

Power supply:

400 V - 50 Hz.

Construction:

B3 – motor mounted on foot.

Impeller:

No. of blades, standard: 6 pcs.

Diameter: ø515 mm

Højde: 196 mm

F a n t y p e M C K 4 0Te c h n i c a l d a t a

m³/h

m³/min.

Pa mmWG

Air volume

Noise level and power input

Useful effect and pressure

kW

Total pressure pt

Useful effect

Dynamic pressure pd

Weight

kW hp amp. of motor

kg

7,5 10,0 14,7 49

11,0 15,0 21,2 69

15,0 20,0 28,2 83

18,5 25,0 34,4 87

hp

Page 34: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

34

0 2 4 6 8

0 2 4 6 81012

10 12 14

14161820

16

20 22 24 26 28 30

22242628303234363840

18

102

83

7981 98 dB(A)

F a n t y p e M C K 5 0 Te c h n i c a l d a t a

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0 2 4 6

0 40 80 120

400440480

400044004800

8 20 22 24 26 2812 14 16 1810

200 240 280 320 360 400 440 480 520 560

30 32 34 x 10

50 6070

77

76

73

6050 %

520560600

520056006000

160

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0 2 4 6

0 40 80 120

400440480

400044004800

8 20 22 24 26 2812 14 16 1810

200 240 280 320 360 400 440 480 520 560

30 32 34 x 10

50 6070

77

76

73

6050 %

520560600

520056006000

160

m³/h

m³/min.

mm WG

Air volume

Noise level and power input

Useful effect and pressure

hp kW

1950 min-1

2050 min-1

2150 min-1

2300 Rmin-1

2450 min-1

Total pressure pt

Useful effect

Dynamic pressure pd2450 min-1

2300 min-1

2150 min-1

2050 min-1

1950 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 2,450 min-1

Operating range:

Air volume: 6,000 – 28,000 m³/h

Pressure: 120 – 520 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø705 mm

Height: 243 mm

Weight kW hp amp. of motor kg 11,0 15,0 21,2 69 15,0 20,0 28,2 83 18,5 25,0 34,4 87 22,0 30,0 40,0 165 30,0 40,0 52,5 240

N/m²

x1000

Page 35: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

35

0 0 4 8 12 16 20 24 28

4 81216202428323640

32

40 44 48 52 56 60

4448525660646872768084889296100

36

646872

98

87

8478 96 dB(A)

F a n t y p e M C K 6 0 Te c h n i c a l d a t a

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

3 6 9

6 12

x 100

x 10

15 18 21 24 27 30 33 36 39 42 45 4812

30 6018 24 36 42 48 54 66 72 78

520560600

520056006000 50

6265

71

75

67

50 %

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

3 6 9

6 12

x 100

x 10

15 18 21 24 27 30 33 36 39 42 45 4812

30 6018 24 36 42 48 54 66 72 78

520560600

520056006000 50

6265

71

75

67

50 %

m³/h

m³/min.

Air volume

Noise level and power input

Useful effect and pressureN/m² mm WG

hp kW

2350 min-1

2200 min-1

2050 min-1

1950 min-1

1850 min-1

Total pressure pt

Dynamic pressure pd

2200 min-1

1950 min-1

1850 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 2,350 min-1

Operating range:

Air volume: 9,000 – 39,000 m³/h

Pressure: 160 – 600 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø805 mm

Height: 285 mm

Weight kW hp amp. of motor kg 22,0 30,0 40,0 165 30,0 40,0 52,5 240 37,0 50,0 67,0 300 45,0 62,0 80,0 330

x1000

Page 36: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

36

0 0 4 8 12 16 20 24 28

4 81216202428323640

32

40 44 48 52 56 60

4448525660646872768084889296100

36

646872

98

88

8477 93 dB(A)

F a n t y p e M C K 7 0 Te c h n i c a l d a t a

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

4 8 12

168

20 24 28 32 36 40 44 48 52 56 60 6416

10424 32 40 48 56 64 72 80 88 96

x1000

x10

50 5765

76

78

70

62

50 %

520560600

520056006000

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

4 8 12

168

20 24 28 32 36 40 44 48 52 56 60 6416

10424 32 40 48 56 64 72 80 88 96

x 1000

x 10

50 5765

76

78

70

62

50 %

520560600

520056006000

m³/h

m³/min.

N/m² mm WG

Air volume

Noise level and power inputhp kW

1950 min-1

1850 min-1

1750 min-1

1650 min-1

Total pressure pt

Useful effect

Dynamic pressure pd 2050 min-1

1950 min-1

1750 min-1

1650 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 2,050 min-1

Operating range:

Air volume: 12,000 – 54,000 m³/h

Pressure: 150 – 600 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø905 mm

Height: 315 mm

Weight kW hp amp. of motor kg 30,0 41,0 53,0 230 37,0 50,0 67,0 300 45,0 62,0 80,0 330

55,0 75,0 97,0 435 75,5 103,0 133,0 610

x1000

Page 37: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

37

0 0 4 8 12 16 20 24 28

4 81216202428323640

32

40 44 48 52 56 60

76

4448525660646872768084889296100

36

646872

104

85

84 99dB(A

F a n t y p e M C K 8 0 Te c h n i c a l d a t a

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

4 8 12

168

20 24 28 32 36 40 44 48 52 56 60 64 68 x 10016

104 112 x 1024 32 40 48 56 64 72 80 88 96

50 6374

75

76

70

6050 %

520560600

520056006000

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

0

0

400440480

400044004800

4 8 12

168

20 24 28 32 36 40 44 48 52 56 60 64 68 x 10016

104 112 x 1024 32 40 48 56 64 72 80 88 96

50 6374

75

76

70

6050 %

520560600

520056006000

m³/h

m³/min.

Air volume

Noise level and power input

Useful effect and pressure

hp kW

1850 min-1

1750 min-1

1650 min-1

1550 min-1

1450 min-1

Total pressure pt

Useful effect

Dynamic pressure pd1850 min-1

1750 min-1

1650 min-1

1550 min-1

1450 min-1

N/m² mm WG

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 1,850 min-1

Operating range:

Air volume: 16,000 – 64,000 m³/h

Pressure: 160 – 560 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø1007 mm

Height: 357 mm

Weight kW hp amp. of motor kg 37,0 50,0 67,0 300 45,0 62,0 80,0 330 55,0 75,0 97,0 435

75,5 103,0 133,0 610 90,0 123,0 159,0 660

x1000

Page 38: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

38

0 0 10 20 30 40 50 60 70

102030405060708090

8090

100110120130140150160170

110120130140150160170180190200210220230

100 102

83 82 98 dB(A)

F a n t y p e M C K 9 0 Te c h n i c a l d a t a

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

400440480

400044004800

0 105

0

15 20

25

25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100105110 x 1

5068

73

75

73

60

50 %

10050 75 125 150 175 x 10

520560600

520056006000

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

400440480

400044004800

0 105

0

15 20

25

25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100105110 x 1

5068

73

75

73

60

50 %

10050 75 125 150 175 x 10

520560600

520056006000

m³/h

m³/min.

N/m² mm WG

Air volume

Noise level and power input

Useful effect and pressure

hp kW

1650 min-1

1550 min-1

1450 min-1

1350 min-1

1250 min-1

Total pressure pt

Useful effect

Dynamic pressure pd 1650 min-1

1550 min-1

1450 min-1

1350 min-1

1250 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 1,650 min-1

Operating range:

Air volume: 25,000 – 80,000 m³/h

Pressure: 150 – 560 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø1127 mm

Height: 417 mm

Weight kW hp amp. of motor kg 45,0 62,0 80,0 330 55,0 75,0 97,0 435 75,5 103,0 133,0 610

90,0 123,0 159,0 660 110,0 151,0 195,0 830

x1000

Page 39: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

39

0 0 10 20 30 40 50 60 70

102030405060708090

8090

100110

130140150160170

110120130140150160170180190200210220230

100

120

104

85 82 100 dB(A)

F a n t y p e M C K 1 0 0 Te c h n i c a l d a t a

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

400440480

400044004800

0

0

10 20

25

30

50 75 100 125 150 175 200

40 50 60 70 80 90 100 110 120 130 140 x 100

225 x 10

50 5964

7173

74

75

74

65

50 %

520560600

520056006000

640

0 40 80120160200240280320

0 400 80012001600200024002800

36032003600

400440480

400044004800

0

0

10 20

25

30

50 75 100 125 150 175 200

40 50 60 70 80 90 100 110 120 130 140 x 100

225 x 10

50 5964

7173

74

75

74

65

50 %

520560600

520056006000

640

m³/h

m³/min.

N/m² mm WG

Air volume

Noise level and power input

Useful effect and pressure

hp kW

1550 min-1

1450 min-1

1350 min-1

1250 min-1

1150 min-1

Total pressure pt

useful effect

Dynamic pressure pd1550 min-1

1450 min-1

1350 min-1

1250 min-1

1150 min-1

Motor: IP 55

Supplied with the following motors:

Max. min-1:

Standard impeller: 1,550 min-1

Operating range:

Air volume: 25,000 – 115,000 m³/h

Pressure: 140 – 600 mm WG

Power supply:

400 V - 50 Hz.

Construction:

B3 - motor mounted on foot.

Impeller:

No. of blades, standard: 8 pcs.

Diameter: ø1257 mm

Height: 484 mm

Weight kW hp amp. of motor kg 55,0 75,0 97,0 435 75,5 103,0 133,0 610 90,0 123,0 159,0 660

110,0 151,0 195,0 830 132,0 180,0 232,0 910

x1000

Page 40: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

40

The type AB acoustic booths are used for noise reduction. The

acoustic booths are supplied with fitted fan or in kit form.

The acoustic booth is as standard supplied with rotatable flange fitted

on in- and outlet. This provides easy connection to the remaining

ducting. Acoustic booths are supplied with same dimension of inlet

and outlet flange as the fan.

Acoustic booths are assembled by means of clamps that hold the big

panels to the steel frame.

At service/inspection you can then quickly remove the sides and

have easy access to the fan. The panels are provided with handle for

easy handling. The panels tighten with rubber strip against the frame.

Noise and vibrations are in this way reduced. Acoustic booths are

made from galvanized sheet (Z275).

The damping material is an environment friendly material, made from

recycling material from polyethylene production, covered with foil

and fire resistant material.

The acoustic booth is as standard supplied with cooling fan fitted in

bottom, for optimum cooling.

Extras

The acoustic booths are supplied with light fixture to the ceiling

lights, thermostat control for cooling fan and connection box for

assembly of cables as extras.

A c o u s t i c b o o t h s t y p e A B

For dimensional specifications, see below.

Dimensions

TypeL

mmW

mmH(H1)mm

Weightkg

AB-20 990 1133 1265 (1305) 139

AB-30 1410 1315 1460 (1499) 198

AB-40 1549 1453 1595 (1633) 252

AB-50 2140 1823 2247 501

AB-60 2500 2071 2477 644

AB-70 2871 2262 2549 871

AB-80 3075 2615 2884 970

AB-85 3075 2615 3135 1013

L W

H H1

L W

H H1

Page 41: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

41

63 125 250 500 1000 2000 4000 8000

0

10

20

A c o u s t i c b o o t h s t y p e A BTe c h n i c a l d a t a

Black diagram shows general damping values for fans in acoustic booth. Blue diagram shows equivalent damping values, when structure borne noise from fan and acoustic booth is not transmitted.

Cooling fan is fitted in a sound absorbent box with washable intake

filter.

Cooling fan type 4656 Z:

Power supply 230 V, 50/60 Hz

at 230 V, 18 W, 0,1 A

For use with max. 5,5 kW electric motor

For use with type AB-20 and AB-30 acoustic booth

Cooling fan type W 2 E 200 HH 38-05:

Power supply 230 V, 50/60 Hz or 230/400 V, 50/60 Hz

at 230 V, 80 W, 0,35 A

For use with 7,5 – 22 kW electric motor

For use with type AB-30 – AB-50 acoustic booth

Cooling fan type W 2 E 250 HL 06-01:

Power supply 230 V, 50/60 Hz or 230/400 V, 50/60 Hz

at 230 V, 127 W, 0,83 A

For use with 30 – 90 kW electric motor

For use with type AB-50 – AB-85 acoustic booth

Noise reduction

The diagram shows the noise-suppression values for fans in acoustic

booth.

Individual reports for each combination of fan and acoustic booth can be

provided.

Noise measurement made by DELTA.

Choice of acoustic booth:L after fan description indicates long version with guide vane.* The fan can with alternative position, be installed in a smaller acoustic booth.

dB

Frequency [Hz]

Position

Fan RV, LO RN, LN RO, LV

MTD 20 AB-20 AB-20 AB-20

MTD 22 AB-20 AB-20 AB-20

MTD 25 AB-20 AB-20 AB-20

MTD 30 AB-20 AB-20 AB-20

MTD 35 AB-30 AB-30 AB-30

MTD 40 AB-30 AB-30 AB-30

MTK 40 AB-40 AB-40 AB-40

MTK 45 AB-40 AB-40 AB-50*

MTK 55 AB-50 AB-50 AB-50

MTK 75 AB-60 AB-60 AB-60

BTD/BTK/BPD/BPK 200 AB-40 AB-40 AB-40

BTD/BTK/BPD/BPK 300 AB-50 AB-50 AB-50

BTD/BTK/BPD/BPK 400 AB-50 AB-50 AB-50

BTD/BTK/BPD/BPK 500 AB-60 AB-60 AB-60

MCD 30 AB-30 AB-30 AB-30

MCD 40 AB-30 AB-30 AB-40*

MCD 50 AB-50 AB-50 AB-50

MCK 40 AB-40 AB-40 AB-40

MCK 50 AB-50 AB-50 AB-50

MCK 60 AB-50 AB-50 AB-50

MCK 70 AB-60 AB-60 AB-60

Page 42: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

42

Page 43: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

43

Page 44: Data sheet Fan Systems - Interempresas · 2019. 8. 1. · Page 39 Section 05. ... n 2 L 1 = Noise level at min-1 n 1 n 2 ... kW hp amp. of motor kg 1,1 1,5 4,3 10 N/m² mmWG hp kW

Kongskilde industries A/STel. +45 33 68 37 00 [email protected]

1230

019

09

EX

P/G

B/F

an S

yste

ms/

DA

TA/0

416