DATA SHEET BROCADE FCOE10-24 BLADE · Utilized in a Brocade DCX or Brocade DCX-4S chassis, the...
Transcript of DATA SHEET BROCADE FCOE10-24 BLADE · Utilized in a Brocade DCX or Brocade DCX-4S chassis, the...
HIGHLIGHTS•ProvidesFibreChanneloverEthernet(FCoE)andDataCenterBridging(DCB)end-of-rowserverconnectivityusinghigh-densityBrocadeDCXBackbones
•Deliversline-rate10Gbpsperformanceacross24DCBportsusingacut-through,non-blockingarchitecture
•ProcessesFCoEtrafficatwirespeedfortransporttoFibreChannelandFCoEstoragesystems
•Supportsend-to-endFCoEusingFibreChannelISLs
•UtilizesLinkAggregationControlProtocol(LACP)andBrocadeframe-basedtrunkingtomaximizeDCBbandwidth
•CombineswithBrocadeConvergedNetworkAdapters(CNAs)andBrocadeNetworkAdvisortoprovideaunifiedDCB/FCoEsolutionthatreducesCapExandOpEx
High-Density, End-of-Row Connectivity for Server I/O Consolidation
Designedformidsizeandlargeenterpriseenvironments,theBrocade®FCOE10-24BladeforBrocadeDCX®BackbonesenablesaccesstoLANsandSANsoveracommonserverconnectionbyutilizingtheemergingDataCenterBridging(DCB)andFibreChanneloverEthernet(FCoE)protocols.ThebladeforwardsLANtraffictoaggregationlayerEthernetswitchesusingconventional10GigabitEthernet(GbE)connections,anditforwardsstoragetraffictoBrocadeFibreChannelSANsandFCoEstoragesystems.
Fullsupportforend-to-endFCoEisachievedviaFibreChannelISLs,allowingFCoEtraffictobecarriedfromFCoEinitiatorsacrossmultipleFibreChannelISLhops,eventuallyterminatinginFibreChannelorFCoEstorage.Bysimplifyingsystemconfiguration,theBrocadeFCOE10-24enablesBrocadeDCXBackbonestoprovidehigh-density,end-of-rowserverconnectivitythathelpsreducebothcapitalandoperatingexpensesinenterprisedatacenters.
A UNIFIED DCB/FCOE SOLUTION TO REDUCE COSTS TheBrocadeFCOE10-24connectstoserversutilizingBrocade1010/1020ConvergedNetworkAdapters(CNAs)orthird-partyCNAs.ConsolidatingserverI/Oreducesthenumberofserveradapters,whichinturnreducescablingandswitchports,andultimatelyresultsinlowerinfrastructurecosts,includingreduced
BROCADEFCOE10-24BLADE
STORAGE AREA NETWORK
DATASHEET www.brocade.com
powerandcoolingcosts.Tofurtherreducecomplexityandadministrativeoverhead,organizationscanmanageBrocadeCNAsandBrocadeDCXBackbonesacrosstheirBrocadeFibreChannelSANinfrastructureswithBrocadeNetworkAdvisor—providingaunifiedDCB/FCoEsolutionthatisuniqueintheindustry.
INDUSTRY-LEADING PERFORMANCE AND SCALABILITYUtilizedinaBrocadeDCXorBrocadeDCX-4Schassis,theBrocadeFCOE10-24Bladesupportsdata-intensiveapplicationsbydeliveringbest-in-classperformance.
TheBrocadeOne™strategyhelpsorganizationstransitionsmoothlytoaworldwhereinformationandapplicationsresideanywhere.TheBrocadeFCOE10-24BladesupportsthisstrategybyenablingLANandSANaccessoverasingleserverconnectiontosimplifynetworkdesign.
Itsnon-blockingarchitecturefeatures2410GbEDCBports.EachBrocadeDCXandBrocadeDCX-4SchassissupportsamaximumoffourBrocadeFCOE10-24Blades,providingupto9610GbEFCoE/DCB-capableportsperchassis.
Inaddition,uniqueBrocadeframe-basedtrunkingprovidesunmatchedserverconnectionthroughput(upto40Gbps).ThebladealsoutilizesadvancedASICtechnologytoprovidestandards-basedLinkAggregationControlProtocol(LACP)forLANconnections.
COMPREHENSIVE LAYER 2 LAN CAPABILITIES LeveragingdeepBrocadeexpertiseinEthernettechnologies,theBrocadeFCOE10-24providesbroad,standards-basedDataLinkLayer(Layer2)capabilities.DCBportsprovideuplinkconnectionstoaggregationlayerEthernetswitches(Brocadeorthird-partydevices)usingconventional10GbEports.Layer2functionsareconfiguredandadministeredaccordinglyattheaccesslayer.
FABRIC OS-POWERED, NON-DISRUPTIVE SAN CONNECTIVITY TheBrocadeFCOE10-24utilizesthesameBrocadeFabricOS®thatsupportstheentireBrocadeSANproductfamily—fromfixedportswitchestotheBrocadeDCXBackbone.Thishelpsensurebackwardandforwardcompatibility,andenablesseamless,high-speedconnectivitytoBrocadeFibreChannelSANsandFCoEstoragesystems(seeFigure1).TheBrocadeDCXcontrolprocessorfailoverandfirmwareupgradeprocessesarecompletelynon-disruptivetoFCoEandFibreChanneltrafficflowingthroughtheBrocadeDCXBackbone.
HIGHER FABRIC SECURITY Tohelporganizationssafeguardtheircriticalinformation,theBrocadeFCOE10-24isdesignedforthehighestleveloffabricsecurity.ItutilizesadvancedportandswitchAccessControlLists(ACLs)tosimplifyadministrationandsignificantlyincreasecontroloverdataaccess.Toenhanceaccesssecurity,theBrocadeFCOE10-24supportsActiveDirectorywithLDAPand802.1xsecurityandauthentication.
SEAMLESS, UNIFIED MANAGEMENTBrocadeNetworkAdvisorprovidescomprehensivemanagementofunifieddatacenterfabrics,includingconfiguration,monitoring,andmanagementoftheBrocadeDCXBackboneandBrocadedirectors,routers,switches,HostBusAdapters(HBAs),andCNAs.Italsohelpsorganizationsdiscover,monitor,andmanageconvergedFCoEnetworkenvironmentsaswellasIPswitchingandroutingnetworks.
BrocadeNetworkAdvisorprovidescomprehensiveLayer2configuration,witheasy-to-useDCBinterfaceadministration,FCoEportandtrunkconfigurations,andQualityofService(QoS).
MAXIMIZING INVESTMENTS Tohelpoptimizetechnologyinvestments,Brocadeanditspartnersoffercompletesolutionsthatincludeeducation,support,andservices.Formoreinformation,contactaBrocadesalespartnerorvisitwww.brocade.com.
Figure 1. TheBrocadeFCOE10-24supportsend-to-endFCoE,allowingtraffictobecarriedfromFCoEinitiatorsacrossmultipleFibreChannelISLhopstoFibreChannelorFCoEstorage.
Brocade1010/1020
CNAs
DCB/FCoE
Brocade DCX FCOE10-24 Blade
Brocade DCXFibre ChannelBlade
Brocade DCXFCoE10-24 Blade
Brocade DCXor DCX-4S
IP Traffic
Fibre Channel SAN
FCoE Storage
FCoE Storage
LAN
Access LayerServers
Brocade Network Advisor
System ArchitectureDCBports 24portswith10GigabitEthernet(GbE)FCoE TheBrocadeFCOE10-24de-encapsulatesFCoE
trafficandforwardsittochassis-basedBrocadeDCXFibreChannelportblades
Performance 10GbpslinespeedMaximumframesize 9048-byteEthernetframeforDCBportsDatatraffictypes Fabricswitchessupportingunicast,
multicast(255groups),andbroadcastMACaddresstableentries
32,000MACaddresses
DCBfeatures Priority-basedFlowControl(PFC):IEEE802.1Qbb
EnhancedTransmissionSelection(ETS):IEEE802.1Qaz
DataCenterBridgingeXchange(DCBX)DCBmediatypes Hot-pluggable,Brocade10GbESFP+supports
anycombinationofShort-Reach(SR)andLong-Reach(LR)opticaltransceivers
Data Link Layer (Layer 2) FeaturesLayer2features Layer2VirtualLocalAreaNetworks(VLANs):4096
VLANEncapsulation802.1Q
RapidSpanningTreeProtocol(RSTP)
MultipleSpanningTreeMSTP(802.1s):16instances
STPPortFastandPortFastGuard
STPRootGuard
LinkAggregationControlProtocol(LACP)IEEE-802.3ad
Brocadeenhancedframe-basedtrunking
AdvancedPortChannelhashingbasedonLayer2,3,and4information
PauseFrames(802.3x)
StormControl(unicast,multicast,andbroadcast)
AddressResolutionProtocol(ARP)RFC826
InternetGroupManagementProtocol(IGMP)snoopingversions1,2,and3
Layer2security IngressAccessControlLists(ACLs)
StandardandextendedLayer2ACLs
VLAN-basedACLs(VACLs)
Port-basedACLs(PACLs)
NamedACLs
ACLstatistics
OptimizedACLdistribution
Port-basednetworkAccessControl,IEEE802.1X
Layer2QualityofService(QoS)
EightprioritylevelsforQoS
IEEE802.1pClassofService(CoS)
Eighthardwarequeuesperport
Per-portQoSconfiguration
CoStrust:IEEE802.1p
ModularQoSCLI(MQC)compliance
Per-portVirtualOutputQueuing
CoS-basedegressqueuing
EgressStrictPriorityQueuing
Egressport-basedscheduling:WeightedRound-Robin(WRR)
FCoEfeatures CompleteT11FCoEentityandFCoEbridging.TheFCoEhardwareengineprovides:
• DetectionofFibreChannelencapsulationandredirectionofFCoEfabricloginframes
• EncapsulationofFibreChannelframesinFCoEEthernetpackets(FC>FCoE)
• ExtractionofFibreChannelframesfromFCoEEthernetpackets(FCoE>FC)
• MappingofFibreChanneldestinationVirtualFabricsanddestinationFC_IDtoEthernetVirtualLANanddestinationMACaddresses
Fabric-ProvidedMACAddresses(FPMAs)enablenewEthernetMACaddressestobecreatedusingtheFC_IDassignedbythefabric.
Licensingoptions FCoEsupportisenabledontheBrocadeFCOE10-24blade
ManagementManagementsoftware BrocadeNetworkAdvisor:
• BrocadeNetworkAdvisorusesHTTP/HTTPSandSNMPprotocolstocommunicatewiththeBrocadeDCX/DCX-4StomanageandmonitorDCBfeatures
• BrocadeNetworkAdvisorsupportsthefollowingFCoE/DCBfunctionality:
- Discovery,connectivitymap,andproductlist
- Configurationmanagement
- Performancemanagement
- Faultmanagement
- Securitymanagement
• WebTools
BROCADE FCOE10-24 SPECIFICATIONSThefollowingfeatureinformationisbasedonaBrocadeDCXBackbonerunningFabricOS6.4.1_fcoeorhigher.
DATASHEET
©2010BrocadeCommunicationsSystems,Inc.AllRightsReserved.12/10GA-DS-1459-02
Brocade,theB-wingsymbol,BigIron,DCFM,DCX,FabricOS,FastIron,IronView,NetIron,SANHealth,ServerIron,TurboIron,andWingspanareregisteredtrademarks,andBrocadeAssurance,BrocadeNETHealth,BrocadeOne,ExtraordinaryNetworks,MyBrocade,VCS,andVDXaretrademarksofBrocadeCommunicationsSystems,Inc.,intheUnitedStatesand/orinothercountries.Otherbrands,products,orservicenamesmentionedareormaybetrademarksorservicemarksoftheirrespectiveowners.
Notice:Thisdocumentisforinformationalpurposesonlyanddoesnotsetforthanywarranty,expressedorimplied,concerninganyequipment,equipmentfeature,orserviceofferedortobeofferedbyBrocade.Brocadereservestherighttomakechangestothisdocumentatanytime,withoutnotice,andassumesnoresponsibilityforitsuse.Thisinformationaldocumentdescribesfeaturesthatmaynotbecurrentlyavailable.ContactaBrocadesalesofficeforinformationonfeatureandproductavailability.ExportoftechnicaldatacontainedinthisdocumentmayrequireanexportlicensefromtheUnitedStatesgovernment.
Corporate Headquarters SanJose,CAUSAT:[email protected]
European Headquarters Geneva,SwitzerlandT:[email protected]
Asia Pacific Headquarters SingaporeT:[email protected]
www.brocade.com
BROCADE FCOE10-24 SPECIFICATIONS (CONTINUED)
Managementprotocols Industry-commonCommandLineInterface(CLI)
SecurityShell(SSH)v2
Authentication,Authorization,andAccounting(AAA)
SimpleNetworkManagementProtocol(SNMP)v1,v2,andv3
UnifiedusernameandpasswordsacrossCLIandSNMP
Syslog
MicrosoftChallengeHandshakeAuthenticationProtocol(CHAP)
RemoteMonitoring(RMON)
Per-portingressandegresscounters
Role-BasedAccessControl(RBAC)
Power-OnSelf-Test(POST)
ComprehensivebootupdiagnosticsDiagnostics Power-OnSelf-Test(POST):Thesetestsareport
blade-orientedtoensurethattheswitchisreadyforuse.Testingisperformedonphysicalports.
Switch-leveltestingisexecutedattheuserportlevel.ThetestsrelyonthestandardFabricOSsupporttoprovideroutingandportsetup.
Manufacturingsupportincludeslong-durationtesting.
ForinformationaboutsupportedSANstandards,visitwww.brocade.com/sanstandards.
Forinformationaboutswitchanddeviceinteroperability,visitwww.brocade.com/interoperability.
Forinformationabouthardwareregulatorycompliance,visitwww.brocade.com/regulatorycompliance.
MechanicalSize Width:27.9cm(11.0in)
Height:41.2cm(16.2in)Thickness:3.6cm(1.4in)
EnvironmentalTemperature Operating:0°Cto40°C(32°Fto104°F)
Non-operating:–25°Cto70°C(–13°Fto158°F)Humidity Operating:10%to85%non-condensing
at40°C(104°F)Non-operating:10%to93%at70°C(158°F)
Altitude Operating:Upto3000m(9842ft)Storage:Upto12km(39,370ft)
Shock Operating:20g,6mshalf-sineNon-operating:33g,11ms,half-sine
Vibration Operating:0.5gp-p,5to500to5HzNon-operating:2.0gp-p,5to500to5Hz
PowerPower Nominal:250wattsInputvoltage 40to50VACnominalInputlinefrequency 47to63HzInrushcurrent 60ampsmaximumMaximumcurrent 29ampsat12VDC