Data gain table (and with / without DAC table)

9
Data gain table (and with/without DAC table) H. Miyamoto for PDM & DP team LAL/IN2P3/Univ. Paris-Sud XI

description

Data gain table (and with / without DAC table). H. Miyamoto for PDM & DP team LAL/IN2P3/ Univ . Paris-Sud XI. 3 kinds of Data taken during the flight. DAC 250 (no gain table, no DAC table) No threshold adjustment , nor gain equalization - PowerPoint PPT Presentation

Transcript of Data gain table (and with / without DAC table)

Page 1: Data gain table  (and  with / without  DAC table)

Data gain table (and with/without DAC table)

H. Miyamoto for PDM & DP teamLAL/IN2P3/Univ. Paris-Sud XI

Page 2: Data gain table  (and  with / without  DAC table)

3 kinds of Data taken during the flight• DAC 250 (no gain table, no DAC table)

– No threshold adjustment, nor gain equalization– 13 NIST pixels obtained in pre-flight calibration– C. Moretto’s presentation

• Data with DAC table– PDM calibration was done in this condition– 20 NIST pixels obtained in pre-flight calibration

• Data with gain table (with DAC250)– Gain table based on the calibration with test_ec_board is used.– HV majority for each EC_unit are 1000~1100V instead of 950V (operation

voltage)– Not optimized with PDM condition, but still better equalization in pulse

heights– Taken mainly to demonstrate the function– 13 NIST piexels obtained in pre-flight calibration

Page 3: Data gain table  (and  with / without  DAC table)

DAC (threshold) and pulse height (gain)EC2 s-curves, DAC250, DACtable (260,230,250,220)

Page 4: Data gain table  (and  with / without  DAC table)

DAC table

• Based on PDM measurement -- high statistic s-curve (25 packet, step 1, DAC 0-600) in LISA vacuum vessel at APC

• Many EC-unit have too low gain with HV950V• Remain DAC250 for such EC-units

220 250 260 230 230 240

250 220 260 240

240 240 240

240 230 230

270 260 270 250

270 270 270 240

dactable.txt used for the flight

Page 5: Data gain table  (and  with / without  DAC table)

Gain Table

36 x 64 ascii input file:(ASIC0,Ch0) (ASIC0,ch8) (ASIC0,ch16) … (ASIC0,ch63) (ASIC0,ch1) (ASIC0,ch9)….(ASIC1,Ch0) (ASIC1,ch8) (ASIC1,ch16) …….…

(ASIC0,Ch0) (ASIC7,ch0) (ASIC0,ch16) ….(ASIC0,Ch8) …….…

Ok, too complicated for now, we will make summary/techinical document near future….

After long fight since April, we made it work on July 1st 2014

Page 6: Data gain table  (and  with / without  DAC table)

Gain equalization with test_ec_board

Light source(LED in optical integration sphere)

EC-unitEC-ASICboard

EC-ASICtest board

S-curves before eq.(gain 64 for all pixs)

S-curves after eq.(With gain table)

EC_unit109 PMT_A

50 100 150 200 250 300 350 400 450 50050 100 150 200 250 300 350 400 450 500

Page 7: Data gain table  (and  with / without  DAC table)

Gain equalization with test_ec_board

Light source(LED in optical integration sphere)PDM

S-curves before eq. S-curves after eq.

EC_unit109 PMT_A

Page 8: Data gain table  (and  with / without  DAC table)

Before/after equalization (PDM)EC7 EC7

EC9 EC9

Page 9: Data gain table  (and  with / without  DAC table)

Summary

• Analysis of absolute efficiency with gain table configuration is ongoing in the same method as other two conditions (no gain table, with/without DAC table)

• Further calibration will be done after PDM returning to Paris (in November?)

• When it’s ready, would be implemented in the table for the analysis with other parameters