Data Center Replication Across the WAN with...
-
Upload
truongnhan -
Category
Documents
-
view
220 -
download
0
Transcript of Data Center Replication Across the WAN with...
1
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Data Center Replication Across the WAN with
EMC
2
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Who is Riverbed?
The IT infrastructure performance company A profitable public company (RVBD)
• $394 million in revenue (Fiscal 2009) • Global sales and support operations
A trusted IT supplier to over 8,700 customers • Tens of thousands of appliances installed and operating around the world
The vendor with the best products in the market • Steelhead appliances offer best performance across key applications. • They are the most scalable solutions on the market • And the easiest to deploy and manage
3
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Riverbed: Continued Fast Revenue Growth ($M)
~$86M
$23M
$90.2
$236.4
$22.9
$333.3
$394.1
4
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Riverbed Q2 2010: Market Share Leader
Source: Gartner 2006 - 2010
WOC Advanced Platform Market Share
Note: Included within “other” for the given quarter.
0.0%
5.0%
10.0%
15.0%
20.0%
25.0%
30.0%
35.0%
40.0%
45.0%
3Q06 4Q06 1Q07 2Q07 3Q07 4Q07 1Q08 2Q08 3Q08 4Q08 Q109 Q209 Q309 Q409 Q110 Q210
Packeteer
Expand
Juniper
Riverbed
Cisco
Blue Coat Others
Silver Peak Citrix
5
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
5
Productivity
Application Acceleration
Consolidation & Virtualization
Bandwidth Optimization
Speed up delivery of:
File Sharing Email Web SSL ERP & CRM Databases CAD & BIM Custom apps
Increase efficiency of: Servers Storage arrays Backup hardware VM replication Thin clients Server-less
branches
Maximize results around:
WAN bandwidth WAN latency WAN upgrades Satellite
communications Quality of service
Disaster Recovery
Improve capabilities: Recovery time (RTO) Recovery point (RPO) Replication WAN backup
Cost Savings Data Protection
WAN Optimization – Critical to Enterprise Success
6
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Riverbed’s Complete Family of Performance Products
WAN
Steelhead Appliances
Cascade
Virtual Steelhead for the Cloud
7
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
VIRTUALLY ELIMINATE APPLICATION LATENCY
Riverbed’s patented technology advantage
DE-DUPLICATE DATA
OPTIMIZE TCP
USERS DATA CENTER NETWORK
Data
VISIBILITY & PERFORMANCE MANAGEMENT
8
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
8
• Windows File Sharing & Windows-based applications
• Microsoft Exchange (including encrypted email and Exchange Online)
• Web applications & secure web applications
• Database driven applications
• Optimization of storage protocols
Application Optimization modules
CIFS
MAPI
HTTP / HTTPS
MS-SQL
BACKUP & REPLICATION
SRDF/A , FC/IP
• Simplified replication of remote servers
• Unix File Sharing & Unix-based applications NFS
ORACLE • Oracle forms traffic
LOTUS NOTES • Lotus Notes email & collaboration
• Citrix ICA traffic XenApp
9
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Riverbed Multiplies the Effectiveness of IT Key Initiatives
Source: Wedbush : Wave Q4 2009—Dec 21 2009
BC/DR
Collaboration
Performance Management
Virtualization
Cloud Computing
Application Performance
Consolidation
Cost Cutting
Relative Importance of IT initiatives to Organization’s Business Initiatives for 2010
% of time mentioned as critical or high priority to the organization
10
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
What’s the big picture goal of DR? Take all the data you have (right now) Frequently copy the data (far enough away to be safe) Be able to restore quickly (when needed) And do all of the above reliably, inexpensively, and simply
Laptops
Desktops
Servers
Storage
Branch Offices
Headquarters
Home Offices
11
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
11
WAN DATA CENTER
Local backup in branch offices
Unprotected desktops & laptops
Limited replication to recovery datacenter sites
Network diagram (without WAN optimization)
Expensive Unreliable Limited coverage Heavy administration
12
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
12
WAN DATA CENTER
Protect branch offices across the WAN
(or consolidate IT to the datacenter)
Backup desktops & laptops across the WAN
Steelhead Appliance
Replicate all data to recovery datacenter sites
Steelhead Mobile
Steelhead Appliance
Steelhead Appliance All powered by the Riverbed Optimization System (RiOS)
Network diagram (with WAN optimization)
ROI in hardware & bandwidth savings Reliable & Resilient Comprehensive Automated
13
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
WAN
RiOS enhancements for DR use cases
DATA CENTER DR SITE
Traffic Recognition Adaptive Data Optimization Algorithms
Riverbed toolkit approach: choose the best technology for the job Flexible yet simple Per-TCP connection approach Analyze for memory or disk & memory data reduction Choose between data reduction or compression
14
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
EMC Partnership E-Lab qualified Steelhead solutions:
• SRDF, Recover Point, Celerra Replicator, Mirrorview, SAN Copy Unique SRDF and FCIP protocol optimizations Auto-configure for SRDF EMC specific Steelhead 501, 601, 701 models A few of our joint customers:
15
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
SRDF/A Performance @ GTE Federal Credit Union
Background: • Credit Union with OC-3 with 50 ms RTT • SRDF/A replication for payment
processing Problem:
• Unable to handle peak data transfers during end-of-week and end-of-month
• Needed to handle 800 Mbps during peak activity
Solution: • Deployed pair of Steeelheads 6050 • Maintained SRDF integrity during peak
transfers • Delivered over 945 Mbps LAN over an
OC-3 WAN 5.9X Throughput
“We haven’t had an SRDF/A group fail since we put Riverbeds in.” Anthony Bender, Director of Technical Support, IS Officer
945 Mbps
155 Mbps
16
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
SRDF/A Performance @ Cal ISO
Environment: • Redundant OC-3 with 12 msec RTT • SRDF/A with other apps • Oracle database replication
Problem: • Backup link was also being used to meet existing data transfer needs. • Needed to reduce the impact of replication traffic on WAN and other critical applications
Solution: • Reduced WAN bandwidth by 6.5x • Enable true network redundancy enabling moving all traffic on the primary link
17
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
SRDF/A Performance @ Chase Paymentech A leading credit card processor for merchants Environment:
• Redundant OC3 with 45 msec RTT • Oracle database replication
Problem: • Needed to reduce the impact of replication traffic
on WAN and other critical applications Solution:
• Reduced WAN bandwidth by 6x • Avoided bandwidth upgrade
18
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Steelhead 7050
ALL SSD-based storage Extreme processing power: 2X6 cores Fault Tolerant Segstore (FTS) 10GigE Ethernet support
Model 701 Series Configurations L M WAN Capacity 1Gbps 1Gbps Raw Capacity 2.8TB 5.0TB Data Store Capacity 2.2TB 4.4TB Storage Fault Tolerence FTS FTS Front Swappable Disks 16 30 RAM 32 GB 48 GB Expansion Slots (PCI-e) 4 Onboard Bypass Ports (Copper) 4 Max. # of Bypass Ports 20
19
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Product Enhancements for DR
“This newest appliance goes far beyond the capabilities of any other vendor offerings for high-end datacenter deployments.”
- Arun Taneja CEO of the Taneja group
20
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Large Health Care Provider Problem:
• OC-48 WAN Pipe • SRDF required 6x OC-12s
worth of capacity Solution:
• Steelhead 7050s • Multiple LAN Gbps per box • 4-6x data reduction
2.2 Gbps
528 Mbps
21
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Data
Application Intelligence – SRDF and FCIP
Data Data …
Data Data Data …
WAN
Use protocol knowledge to improve network deduplication Apply deduplication to the data, not random headers:
• FCIP – 68 bytes of FCIP/FC header for every ~2100 bytes of data • V-MAX SRDF/A – 8 bytes of DIF for every 512 bytes of data
22
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
EMC E-Labs: Before FCIP/SRDF-fluent optimizations
364 Mbps
90 Mbps
23
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
EMC E-Labs: Before FCIP/SRDF-fluent optimizations
548 Mbps
18 Mbps
Real-World Results
30-60% improvement in data reduction and
performance
24
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
25
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
RecoverPoint Performance @ G&T Conveyor
Background • National air industry manufacturer • Poor application and email performance • Enhance DR strategy
Results • 20x acceleration in application performance • Easily move 500 GB of data for DR purposes
Key benefits from deploying Riverbed • Bandwidth savings • Faster file sharing and project delivery • Robust disaster recovery plan
“Our massive half-terabyte DR jobs that basically didn’t work, even over four days, can now be done successfully in a day.” “Now, we have centralized file shares that are accessible at essentially LAN speed anytime, and to top if off our version control problems have disappeared.”
George Tilmon, IT Group
26
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Steelheads with MirrorView/A over ISCSI Results
• 5x throughput improvement with Steelheads • 10x data reduction • Meet RPO with multiple volumes without adding additional bandwidth for DR • Allows replication to occur during business hoursWithout Steelhead single volume
Mirrorview with CLARiiON CX4 Model 120 • Locations: San Diego and Dallas • Latency: 35 – 40ms • WAN bandwidth: 20Mbps • Steelhead Model: 2050M • Performance Tuning: SDR-Adaptive, default CPU settings • SAN Processors: 2 Storage Processors on each CLARiiON array • Connectivity: iSCSI • Data Size: 20TB
27
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Steelhead with EMC Celerra Replicator
A testimony from an architecture and engineering firm at Kansas City, Missouri, USA
Accelerating EMC Celerra V2 Replication and EMC Centera replication 6 Mbps link between Kansas City and Dallas. 6x transfer rate improvement 6 Mbps link feels like a 35 Mbps pipe replicating 200 GB of data a day
Benefits Using Steelhead:
85%-98% data reduction – Reduce bandwidth
6x Transfer Rate improvement – Improve RTO and RPO
28
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
EMC Celerra Replicator
Average of 95% data reduction (including full & incremental backups) over a week
Instead of sending 352GB over the WAN, only 14GB (5% of total data) was sent over the WAN.
29
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Riverbed and the Private Cloud
30
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
The WAN is the backbone of the global enterprise
BRANCH OFFICES
DESIGN TEAMS
MOBILE WORKERS
BACKUP SITE
DATA TRAFFIC
DATA CENTERS
CHINA FACTORY
EMEA HQ
CALL CENTERS
31
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Optimizing VMware with Riverbed
Complete site and server consolidation Riverbed enables consolidation to DC VMware consolidates servers at DC
Consolidation
DR / ROBO
Desktop Virtualization
Riverbed accelerates initial transfer Lessens impact to WAN and applications Avoid additional bandwidth costs
Optimize View Client/RDP access Optimize offline VDI Optimize ThinApp
32
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
• 5 year savings of over $ 60 million • ~20 minute recover time for user
applications after any outage • World’s largest private cloud deployment
• Deployed seamlessly across 20 countries, 5000 apps/applets & 300 remote branches
• Consolidate branch office HW via RSP
• Migrate IT infrastructure to highly virtualized and consolidated private cloud
• Consolidate at both the data center and at remote office locations
Riverbed and the Private Cloud
Challenge:
Solution Benefits:
Bottom Line:
Solution Cisco WAAS
Riverbed Steelhead
Lantmannen findings: • Reduced branch footprint to 1 Steelhead • Enhanced app performance and management • ROI in under a year
33
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
IT Consolidation INSIDE the Branch
Further Consolidation at Branch Office
Branch Office Today
Server Consolidation to Data Center
AD DNS/ DHCP
PRINT SERVER FIREWALL
FILE SERVERS MAIL SERVER
FILERS STORAGE
AD, DNS/DHCP FIREWALL
PRINT SERVER WAN OPTIMIZATION
AD DNS/ DHCP
PRINT SERVER FIREWALL
FILE SERVERS MAIL SERVER
FILERS STORAGE
AD, DNS/DHCP
FIREWALL
ANY VIRTUALIZED SERVICE
34
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
What does it mean to you?
=
Riverbed Packages Run best-of-breed vendors
35
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Does it Scale? 35
1050-L • 8 Mbps throughput • 800 connections
1050-M 10 Mbps throughput 1,300 connections
1050-H 20 Mbps throughput 2,300 connections
2050-L • 45 Mbps throughput • 2,500 connections
2050-M • 45 Mbps throughput • 4,000 connections
2050-H • 45 Mbps throughput • 6,000 connections
Smaller Larger
250-L • 1 Mbps throughput • 30 connections
250-M • 1 Mbps throughput • 125 connections
250-H • 2 Mbps throughput • 200 connections
550-M • 2 Mbps throughput • 300 connections
550-H 4 Mbps throughput 600 connections
5050-L • 90 Mbps throughput • 7,500 connections
5050-M • 90 Mbps throughput • 10,000 connections
5050-H • 155 Mbps throughput • 18,000 connections
6050 • 310 Mbps throughput • 50,000 connections
7050-L • 1 Gbps throughput • 75,000 connections
7050-M • 1 Gbps throughput • 100,000 connections
• 7050’s support up to 4 Gbps LAN-side throughput for DR
Cluster for scale & HA
Interceptor 9350 • 12 Gbps optimized throughput • 1,000,000 optimized TCP
connections
Mobile Worker Steelhead Mobile Software • Installed on end-user machine
Central Management Console 8150
appliance or CMC-VE • Manages and monitors tens
to hundreds of appliances at once
Steelhead Mobile Controller
• Required for Steelhead Mobile
• Manage up to 2,000 concurrent users.
Management & Reporting
36
© 2009 Riverbed Technology. Confidential. IMPORTANT NOTE: The roadmap is for information purposes only and is not a commitment, promise or legal obligation to deliver any new products, features or functionality. The development, release, and timing of any features or functionality described remains at Riverbed's sole discretion.
Thank you