2
M4122 Mobile Solution/Mobile Front-Haul Overview DASAN Network Solution M4122 & M4108 is the cutting egde solution for mobile fronthaul solution and high capacity transmission system on access network. All modules are flexible, if operator want to change for signal, configuration and extended shelf, supplies as easy maintenance. M4122 is located on the central office, the 5U height(included filter shelf). On front side is located as 22 slots SIUs and FAN located and back does power, main control unit, common units. On top located shelf is the passive CWDM/DWDM filter. M4108 is located on remote side or curved area, total 3U height(included filter shelf) except AC/DC convertor. On front is located 8 Slots SIU and common units slot. But PtoP condition, M4122 to be COT-RT both, and so on M4108 possible DASAN Network Solution M4122 & M4108 supports as interface on client as CPRI(3,4,5,6) and OBSAI(3,4). And the M4122 & M4108 provides 2 PSU (Power Supply Unit) slots. And hot-Swapping on the transponder module. This ensures equipment-level reliability with resilient network architecture. Features • CPRI and OBSAI signal delivery as sensitive clock sync. • Hight Capacity on COT side, Multi-Ring support(Max. 4) • Switch-Over within 50msec • Total 22 Slots for Service Interface Unit • Max. CWDM wavelength 18, the total 76 with DWDM • 20nm(CWDM), 100GHz(DWDM C-band) Specification • OSC(Optical Supervisory Channel) as 100Mbps • With EMS, end to end configuration • Network topology is PtoP and Multi-Ring(O-UPSR and 1+1) • Maximum throughput is 76 signal x 3.072Gbps • NBI suport with TL1 and CORBA(Possible) • Power, Main Control Unit Redundancy 20150527 DASAN Networks, Inc. | www.dasannetworks.com

Transcript of DASAN::::::::::::::::::exceptAC/DCconvertor.Onfrontislocated8SlotsSIU...

Page 1: DASAN::::::::::::::::::exceptAC/DCconvertor.Onfrontislocated8SlotsSIU andcommonunitsslot.ButPtoPcondition,M4122tobeCOT-RT both,andsoonM4108possible DASANNetworkSolutionM4122&M4108supportsasinterface

M4122 Mobile Solution/Mobile Front-Haul

Overview

DASAN Network Solution M4122 & M4108 is the cutting egde

solution for mobile fronthaul solution and high capacity

transmission system on access network. All modules are flexible, if

operator want to change for signal, configuration and extended

shelf, supplies as easy maintenance.

M4122 is located on the central office, the 5U height(included

filter shelf). On front side is located as 22 slots SIUs and FAN

located and back does power, main control unit, common units.

On top located shelf is the passive CWDM/DWDM filter. M4108 is

located on remote side or curved area, total 3U height(included

filter shelf) except AC/DC convertor. On front is located 8 Slots SIU

and common units slot. But PtoP condition, M4122 to be COT-RT

both, and so on M4108 possible

DASAN Network Solution M4122 & M4108 supports as interface

on client as CPRI(3,4,5,6) and OBSAI(3,4).

And the M4122 & M4108 provides 2 PSU (Power Supply Unit)

slots. And hot-Swapping on the transponder module. This ensures

equipment-level reliability with resilient network architecture.

Features

• CPRI and OBSAI signal delivery as sensitive clock sync.

• Hight Capacity on COT side, Multi-Ring support(Max. 4)

• Switch-Over within 50msec

• Total 22 Slots for Service Interface Unit

• Max. CWDM wavelength 18, the total 76 with DWDM

• 20nm(CWDM), 100GHz(DWDM C-band) Specification

• OSC(Optical Supervisory Channel) as 100Mbps

• With EMS, end to end configuration

• Network topology is PtoP and Multi-Ring(O-UPSR and

1+1)

• Maximum throughput is 76 signal x 3.072Gbps

• NBI suport with TL1 and CORBA(Possible)

• Power, Main Control Unit Redundancy

20150527 DASAN Networks, Inc. | www.dasannetworks.com

Page 2: DASAN::::::::::::::::::exceptAC/DCconvertor.Onfrontislocated8SlotsSIU andcommonunitsslot.ButPtoPcondition,M4122tobeCOT-RT both,andsoonM4108possible DASANNetworkSolutionM4122&M4108supportsasinterface

M4122 Mobile Solution/Mobile Front-Haul

Specification

Total Service Slots 22 Slots

Common Board

Rear Side 4 Slots

- MCU : Main Control Unit(Redundacy)

- CIU : Communication Interface Unit

- SIU : System Interface Unit Unit

- MDCM : Line Interface & Filter

- MDCS : Line Interface connection

Filter for extension

- FAN-U : Front Panel and FAN Unit

- FAN-R : Rear FAN Unit

- PSU : power Supply Unit

Service Board

Total 22 Slots

- OT3 : 3 CPRI/OBSAI Interface

- OT10 : 4 CPRI/OBSAI Sub Rate

Multiplexer

- MD2-C1/2 : RT1/2 extended Filter

Operating Temp. 0~50°C

Operating Humidity 5~90% (non-condensing)

Power VoltageAC(Covertor) : 100-240VAC, 50/60Hz

DC : -48VDC

Dimensions (W x H x

D)19inch, 5U

Capabilities

Wavelength CWDM or DWDM

Ch Spacing ITU-T Spec. G.694.2 & G.694.1

CWDM/DWDM Grid

• RT1 CWDM : 1270~1410nm 6 Ch

• RT2 CWDM : 1450~1610nm 6 Ch

• RT1 DWDM : 1524.89~1546.61nm

16 Ch

• RT2 DWDM : 1543.73~1555.75nm

16 Ch

• RT1 OSC : 1370 1 Ch

• RT2 OSC : 1390 1 Ch

Resilience Network/System

• MCU(Main Control Unit)

Redundancy

• PSU(Power Supply Unit)

Redundancy

• Within 50msec Switch-over

(O-UPSR, 1+1)

• FAN(How Swapping)

Performance Monitoring

• Board based Temperature

• East/West line Input Power

• CPRI/OBSAI Input Bit Error

• Real Time update

• 15M, 24H Database(Max. 60D)

• Threshold Control by User

Managements

• Concurrent 16 users

• Maximum 1024 Sites Control

• Internal DCC Networks

• 1024 Line Event on Server Real time

• TL1 Interface

• SNMP Trap* Interface

• 10/100Base-T RJ45

Sample Configuration