DASAN::::::::::::::::::exceptAC/DCconvertor.Onfrontislocated8SlotsSIU...
Transcript of DASAN::::::::::::::::::exceptAC/DCconvertor.Onfrontislocated8SlotsSIU...
M4122 Mobile Solution/Mobile Front-Haul
Overview
DASAN Network Solution M4122 & M4108 is the cutting egde
solution for mobile fronthaul solution and high capacity
transmission system on access network. All modules are flexible, if
operator want to change for signal, configuration and extended
shelf, supplies as easy maintenance.
M4122 is located on the central office, the 5U height(included
filter shelf). On front side is located as 22 slots SIUs and FAN
located and back does power, main control unit, common units.
On top located shelf is the passive CWDM/DWDM filter. M4108 is
located on remote side or curved area, total 3U height(included
filter shelf) except AC/DC convertor. On front is located 8 Slots SIU
and common units slot. But PtoP condition, M4122 to be COT-RT
both, and so on M4108 possible
DASAN Network Solution M4122 & M4108 supports as interface
on client as CPRI(3,4,5,6) and OBSAI(3,4).
And the M4122 & M4108 provides 2 PSU (Power Supply Unit)
slots. And hot-Swapping on the transponder module. This ensures
equipment-level reliability with resilient network architecture.
Features
• CPRI and OBSAI signal delivery as sensitive clock sync.
• Hight Capacity on COT side, Multi-Ring support(Max. 4)
• Switch-Over within 50msec
• Total 22 Slots for Service Interface Unit
• Max. CWDM wavelength 18, the total 76 with DWDM
• 20nm(CWDM), 100GHz(DWDM C-band) Specification
• OSC(Optical Supervisory Channel) as 100Mbps
• With EMS, end to end configuration
• Network topology is PtoP and Multi-Ring(O-UPSR and
1+1)
• Maximum throughput is 76 signal x 3.072Gbps
• NBI suport with TL1 and CORBA(Possible)
• Power, Main Control Unit Redundancy
20150527 DASAN Networks, Inc. | www.dasannetworks.com
M4122 Mobile Solution/Mobile Front-Haul
Specification
Total Service Slots 22 Slots
Common Board
Rear Side 4 Slots
- MCU : Main Control Unit(Redundacy)
- CIU : Communication Interface Unit
- SIU : System Interface Unit Unit
- MDCM : Line Interface & Filter
- MDCS : Line Interface connection
Filter for extension
- FAN-U : Front Panel and FAN Unit
- FAN-R : Rear FAN Unit
- PSU : power Supply Unit
Service Board
Total 22 Slots
- OT3 : 3 CPRI/OBSAI Interface
- OT10 : 4 CPRI/OBSAI Sub Rate
Multiplexer
- MD2-C1/2 : RT1/2 extended Filter
Operating Temp. 0~50°C
Operating Humidity 5~90% (non-condensing)
Power VoltageAC(Covertor) : 100-240VAC, 50/60Hz
DC : -48VDC
Dimensions (W x H x
D)19inch, 5U
Capabilities
Wavelength CWDM or DWDM
Ch Spacing ITU-T Spec. G.694.2 & G.694.1
CWDM/DWDM Grid
• RT1 CWDM : 1270~1410nm 6 Ch
• RT2 CWDM : 1450~1610nm 6 Ch
• RT1 DWDM : 1524.89~1546.61nm
16 Ch
• RT2 DWDM : 1543.73~1555.75nm
16 Ch
• RT1 OSC : 1370 1 Ch
• RT2 OSC : 1390 1 Ch
Resilience Network/System
• MCU(Main Control Unit)
Redundancy
• PSU(Power Supply Unit)
Redundancy
• Within 50msec Switch-over
(O-UPSR, 1+1)
• FAN(How Swapping)
Performance Monitoring
• Board based Temperature
• East/West line Input Power
• CPRI/OBSAI Input Bit Error
• Real Time update
• 15M, 24H Database(Max. 60D)
• Threshold Control by User
Managements
• Concurrent 16 users
• Maximum 1024 Sites Control
• Internal DCC Networks
• 1024 Line Event on Server Real time
• TL1 Interface
• SNMP Trap* Interface
• 10/100Base-T RJ45
Sample Configuration
20150527 DASAN Networks, Inc. | www.dasannetworks.com