DAS 9200.00 DOC MPCF NORTH PENTHOUSE, VR ENTRY AND …

3
MARK DATE DESCRIPTION PROJECT NO: DRAWN BY: COPYRIGHT DATE: SHEET TITLE C-1 COVER SHEET #Pln MSN 5/24/2021 1200 East Washington Street Mt Pleasant, IA 52641 C:\Users\miken\OneDrive - Horizon Architecture\My Drive\Horizon\DAS Mt Pleasant\DAS Mt Pleasant.pln DAS 9200.00 DOC MPCF NORTH PENTHOUSE, VR ENTRY AND SHIFT CAPTAIN ROOF ISSUED FOR BIDDING AND CONSTRUCTION COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC. [email protected] PH | (563) 506-4965 WWW.HORIZON-ARCHITECTURE.COM COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture. 6" TYPICAL, UNLESSOTHERWISE NOTED OFFICE 003 1/A-201 D01.1 B2 C3 D4 A1 1.01.01 1.01.01 D01.1 S01 W01 GRAPHIC SYMBOLS INDICATES SECTION LOCATION ON SHEET INDICATES SHEET ON WHICH DRAWING IS SHOWN SECTION / DETAIL MARKER DETAIL / ENLARGED PLAN MARKER INTERIOR ELEVATION MARKER INDICATES ELEVATION LOCATION ON SHEET INDICATES SHEET ON WHICH DRAWING IS SHOWN ELEVATION / SECTION MARKER INDICATES ELEVATION LOCATION ON SHEET INDICATES SHEET ON WHICH ELEVATION IS SHOWN XX YY XX XX YY DETAIL / ENLARGED PLAN MARKER INDICATES DETAIL LOCATION ON SHEET INDICATES SHEET ON WHICH DETAIL IS SHOWN SPACE DESIGNATION WINDOW MARKER DOOR IDENTIFIERS SPACE NAME SPACE NUMBER WALL TYPE MARKER 4C SKYLIGHT MARKER DOOR IDENTIFIER (ELEVATIONS/SECTIONS) ENLARGED PLAN REFERENCE KEYNOTE IDENTIFIER XX YY DOOR IDENTIFIER (PLANS) KEYNOTE; SEE KEYNOTE LEGEND ON DRAWING'S LAYOUT ALTERNATE KEYNOTE; SEE KEYNOTE LEGEND ON DRAWING'S LAYOUT (SEE PARTITION LEGEND) 4 A-1 5 A-1 6 A-1 BELOW SHEET INDEX ID C-1 A-1 A-2 Name COVER SHEET ROOF PLANS ROOF DETAILS SCALE: 1" = 20' 2 SITE KEY 0 10' 20' 40' VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 1 0 ABBREVIATIONS A.D. AREA DRAIN ABV. ABOVE ADA ACCESSIBLE / AMERICANS WITH DISABILITIES ACT ADJ. ADJUSTABLE A.o.R. AREA OF REFUGE ALUM. ALUMINUM ALT. ALTERNATE A.F.F. ABOVE FINISHED FLOOR AC. ACOUSTIC / ACOUSTICAL A.F. ALUMINUM FACE APPX. APPROXIMATE / APPROXIMATELY BD. BOARD BLK. BLOCK / BLOCKING BLDG. BUILDING B.O. BOTTOM OF B.O.S. BOTTOM OF STEEL CAB. CABINET C.C. CENTER-TO-CENTER CLG. CEILING CLOS. CLOSET C.M. CONSTRUCTION MANAGER CMU CONCRETE MASONRY UNIT C.J. CONTROL JOINT CONC. CONCRETE CORR. CORRIDOR COL. COLUMN CONT. CONTINUE / CONTINUOUS CONTR. CONTRACTOR DIA. DIAMETER DTL. DETAIL DN DOWN DWG. DRAWING DEPT. DEPARTMENT DBL. DOUBLE DIM. DIMENSION DR. DOOR EXIST. EXISTING EQ. EQUAL E.C. ELECTRICAL CONTRACTOR EL. ELEVATION ELEV. ELEVATOR ELEC. ELECTRIC / ELECTRICAL EXP. EXPANSION EXT. EXTERIOR EA. EACH F.D. FLOOR DRAIN F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET FIN. FINISH / FINISHED FLR. FLOOR F.O. FACE OF FT. FEET / FOOT FLUOR. FLUORESCENT GYP. GYPSUM GALV. GALVANIZED GA. GAUGE G.C. GENERAL CONTRACTOR HR. HOUR H.P. HIGH POINT HVAC HEAT, VENTILATION, AIR- CONDITIONING HORIZ. HORIZONTAL HT. HEIGHT INSUL. INSULATION / INSULATING I.D. INSIDE DIAMETER INCAND. INCANDESCENT JAN. JANITOR JT. JOINT LBS. POUNDS LAV. LAVATORY LAM. LAMINATE L.P. LOW POINT MAX. MAXIMUM MFR. MANUFACTURER / MANUFACTURED MTL. METAL MIN. MINIMUM MIRR. MIRRORED MTD. MOUNTED M.O. MASONRY OPENING MISC. MISCELLANEOUS MECH. MECHANICAL N.I.C. NOT IN CONTRACT NO. NUMBER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPP. OPPOSITE OPG. OPENING P.C. PLUMBING CONTRACTOR P.F. PANEL FACE PR. PAIR P.T. PRESSURE TREATED PL. LAM PLASTIC LAMINATE QTY. QUANTITY R RISER R.W.C. RAIN WATER CONDUCTOR REINF. REINFORCING / REINFORCED REQ. REQUIRED R.O. ROUGH OPENING REV. REVISED / REVISION REFL. REFLECTED REC. RECESSED RAD. RADIUS S.S. STAINLESS STEEL ST. STREET SIM. SIMILAR STL. STEEL SQ. SQUARE SAN. SANITARY SUSP. SUSPENDED STD. STANDARD SPEC. SPECIFICATION TEL. TELEPHONE T.O. TOP OF T.O.S. TOP OF STEEL T.O.W. TOP OF WALL TOIL. TOILET TYP. TYPICAL THK. THICK TMP. TEMPERED T.S.G. TEMPERED SAFETY GLASS U.O.N. UNLESS OTHERWISE NOTED U.L. UNDERWRITERS LABORATORIES VEST. VESTIBULE V.C.T. VINYL COMPOSITION TILE W/ WITH W.C. WATER CLOSET WD WOOD & AND @ AT ± PLUS OR MINUS ° DEGREE ANGLE [ CHANNEL # NUMBER SQUARE Ø ROUND / DIAMETER / C.L. CENTER LINE / PL. PLATE U-BAR LEG-BAR BUILDING INFORMATION APPLICABLE BUILDING CODE - 2015 IEBC AND IPC CLASSIFICATION OF WORK - REPAIR REPLACEMENT OF DAMAGED MATERIALS (ROOF) FOR THE PURPOSE OF MAINTINING COMPONENTS IN SOUND CONDITION WITH RESPECT TO EXISTING LOADS OR PERFORMANCE REQUIREMENTS. CONFORMANCE REQUIREMENT (601.2) - THE WORK SHALL NOT MAKE THE BUILDING LESS CONFORMING THAT IT WAS BEFORE THE REPAIR WAS UNDERTAKEN. EXISTING GUTTER AND DOWNSPOUT SIZE VALIDATED PER IPC 1106 DESIGN CRITERIA ULTIMATE WIND SPEED (Vult) 115 MPH EXPOSURE B UPLIFT RATINGS ZONE 1 75 PSF ZONE 2 105 PSF ZONE 3 135 PSF BASIS OF DESIGN FM 1-90 PROJECT DIRECTORY OWNER IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES (DAS) 109 EAST 13TH STREET DES MOINES, IA 50319 OWNER'S REPRESENTATIVE: JOSH HERMAN PHONE: 515.725.1293 EMAIL: JOSH . HERMAN @ IOWA . GOV CONSTRUCTION MANAGER THE SAMUELS GROUP 2929 WESTON PARKWAY SUITE 200 WEST DES MOINES, IA 50266 PROJECT MANAGER: JERRY DEHNKE PHONE: 515.518.6576 EMAIL : JDEHNKE @ SAMUELSGROUP . NET ARCHITECT HORIZON ARCHITECTURE 3116 ALPINE COURT IOWA CITY IA 52245 PHONE: (563) 506-4965 CONTACT: MICHAEL NOLAN, AIA EMAIL: [email protected] DAS 9200.00 DOC MPCF NORTH PENTHOUSE, VR ENTRY AND SHIFT CAPTAIN ROOF MOUNT PLEASANT CORRECTIONAL FACILITY MOUNT PLEASANT, IA

Transcript of DAS 9200.00 DOC MPCF NORTH PENTHOUSE, VR ENTRY AND …

Page 1: DAS 9200.00 DOC MPCF NORTH PENTHOUSE, VR ENTRY AND …

MAR

KD

ATE

DES

CR

IPTI

ON

PROJECT NO:

DRAWN BY:COPYRIGHT

DATE:

SHEET TITLE

C-1

COVER SHEET

#Pln

MSN5/24/2021

1200

Eas

t W

ashi

ngto

n Str

eet

Mt

Plea

sant

, IA

526

41

C:\

Use

rs\m

iken

\One

Drive

- H

oriz

on A

rchi

tect

ure\

My

Drive

\Hor

izon

\DAS M

t Pl

easa

nt\D

AS M

t Pl

easa

nt.p

ln

DA

S 9

20

0.0

0 D

OC

MP

CF

NO

RTH

PEN

THO

US

E, V

R E

NTR

Y A

ND

SH

IFT

CA

PTA

IN R

OO

F

ISSU

ED F

OR

BID

DIN

G A

ND

CO

NST

RU

CTI

ON

COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC.

MIC

HAEL

@H

ORIZ

ON

-ARCH

ITEC

TURE.

CO

MPH

| (

563)

506

-496

5W

WW

.HO

RIZ

ON

-ARCH

ITEC

TURE.

CO

M

COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture.

6" TYPICAL, UNLESSOTHERWISE NOTED

OFFICE003

1/A-201

D01.1

B2

C3

D4

A1

1.01.01

1.01.01

D01.1

S01

W01

GRAPHICSYMBOLS INDICATES SECTION

LOCATION ON SHEET

INDICATES SHEETON WHICH DRAWINGIS SHOWN

SECTION / DETAIL MARKER DETAIL / ENLARGED PLAN MARKER

INTERIOR ELEVATION MARKER

INDICATES ELEVATIONLOCATION ON SHEET

INDICATES SHEETON WHICH DRAWINGIS SHOWN

ELEVATION / SECTION MARKER

INDICATES ELEVATIONLOCATION ON SHEET

INDICATES SHEETON WHICH ELEVATIONIS SHOWN

XXYY

XX

XXYY

DETAIL / ENLARGED PLAN MARKER

INDICATES DETAILLOCATION ON SHEET

INDICATES SHEETON WHICH DETAILIS SHOWN

SPACE DESIGNATION

WINDOW MARKER

DOOR IDENTIFIERSSPACE NAME

SPACE NUMBER

WALL TYPE MARKER 4C

SKYLIGHT MARKER

DOOR IDENTIFIER(ELEVATIONS/SECTIONS)

ENLARGED PLAN REFERENCE

KEYNOTE IDENTIFIER

XXYY

DOORIDENTIFIER(PLANS)

KEYNOTE; SEE KEYNOTE LEGENDON DRAWING'S LAYOUT

ALTERNATE KEYNOTE;SEE KEYNOTE LEGENDON DRAWING'S LAYOUT

(SEE PARTITION LEGEND)

4A-1

5A-1

6A-1

BELOW

SHEET INDEXID

C-1

A-1

A-2

NameCOVER SHEET

ROOF PLANS

ROOF DETAILS

SCALE: 1" = 20'2 SITE KEY0 10' 20' 40'

VERIFY SCALEBAR IS ONE (1) INCH LONG ON

ORIGINAL DRAWING

IF BAR IS NOT ONE (1) INCH LONG,ADJUST SCALE ACCORDINGLY

10

ABBREVIATIONSA.D. AREA DRAINABV. ABOVEADA ACCESSIBLE / AMERICANSWITH DISABILITIES ACTADJ. ADJUSTABLEA.o.R. AREA OF REFUGEALUM. ALUMINUMALT. ALTERNATEA.F.F. ABOVE FINISHED FLOORAC. ACOUSTIC / ACOUSTICALA.F. ALUMINUM FACEAPPX. APPROXIMATE /APPROXIMATELYBD. BOARDBLK. BLOCK / BLOCKINGBLDG. BUILDINGB.O. BOTTOM OFB.O.S. BOTTOM OF STEELCAB. CABINETC.C. CENTER-TO-CENTERCLG. CEILINGCLOS. CLOSETC.M. CONSTRUCTION MANAGERCMU CONCRETE MASONRY UNITC.J. CONTROL JOINTCONC. CONCRETECORR. CORRIDORCOL. COLUMNCONT. CONTINUE / CONTINUOUSCONTR. CONTRACTORDIA. DIAMETERDTL. DETAIL

DN DOWNDWG. DRAWINGDEPT. DEPARTMENTDBL. DOUBLEDIM. DIMENSIONDR. DOOREXIST. EXISTINGEQ. EQUALE.C. ELECTRICAL CONTRACTOREL. ELEVATIONELEV. ELEVATORELEC. ELECTRIC / ELECTRICALEXP. EXPANSIONEXT. EXTERIOREA. EACHF.D. FLOOR DRAINF.E. FIRE EXTINGUISHERF.E.C. FIRE EXTINGUISHERCABINETFIN. FINISH / FINISHEDFLR. FLOORF.O. FACE OFFT. FEET / FOOTFLUOR. FLUORESCENTGYP. GYPSUMGALV. GALVANIZEDGA. GAUGEG.C. GENERAL CONTRACTORHR. HOURH.P. HIGH POINTHVAC HEAT, VENTILATION, AIR-CONDITIONING

HORIZ. HORIZONTALHT. HEIGHTINSUL. INSULATION / INSULATINGI.D. INSIDE DIAMETERINCAND. INCANDESCENTJAN. JANITORJT. JOINTLBS. POUNDSLAV. LAVATORYLAM. LAMINATEL.P. LOW POINTMAX. MAXIMUMMFR. MANUFACTURER /MANUFACTUREDMTL. METALMIN. MINIMUMMIRR. MIRROREDMTD. MOUNTEDM.O. MASONRY OPENINGMISC. MISCELLANEOUSMECH. MECHANICALN.I.C. NOT IN CONTRACTNO. NUMBERN.T.S. NOT TO SCALEO.C. ON CENTERO.D. OUTSIDE DIAMETEROPP. OPPOSITEOPG. OPENINGP.C. PLUMBING CONTRACTORP.F. PANEL FACEPR. PAIRP.T. PRESSURE TREATED

PL. LAM PLASTIC LAMINATEQTY. QUANTITYR RISERR.W.C. RAIN WATER CONDUCTORREINF. REINFORCING / REINFORCEDREQ. REQUIREDR.O. ROUGH OPENINGREV. REVISED / REVISIONREFL. REFLECTEDREC. RECESSEDRAD. RADIUSS.S. STAINLESS STEELST. STREETSIM. SIMILARSTL. STEELSQ. SQUARESAN. SANITARYSUSP. SUSPENDEDSTD. STANDARDSPEC. SPECIFICATIONTEL. TELEPHONET.O. TOP OFT.O.S. TOP OF STEELT.O.W. TOP OF WALLTOIL. TOILETTYP. TYPICALTHK. THICKTMP. TEMPEREDT.S.G. TEMPERED SAFETYGLASSU.O.N. UNLESS OTHERWISENOTED

U.L. UNDERWRITERSLABORATORIESVEST. VESTIBULEV.C.T. VINYL COMPOSITIONTILEW/ WITHW.C. WATER CLOSETWD WOOD

& AND@ AT± PLUS OR MINUS° DEGREE� ANGLE[ CHANNEL# NUMBER□ SQUAREØ ROUND / DIAMETER� / C.L. CENTER LINE� / PL. PLATE∏ U-BAR ∟ LEG-BAR

BUILDING INFORMATIONAPPLICABLE BUILDING CODE - 2015 IEBC AND IPCCLASSIFICATION OF WORK - REPAIR

REPLACEMENT OF DAMAGED MATERIALS (ROOF) FOR THEPURPOSE OF MAINTINING COMPONENTS IN SOUND CONDITIONWITH RESPECT TO EXISTING LOADS OR PERFORMANCEREQUIREMENTS.CONFORMANCE REQUIREMENT (601.2) - THE WORK SHALL NOTMAKE THE BUILDING LESS CONFORMING THAT IT WAS BEFORETHE REPAIR WAS UNDERTAKEN.

EXISTING GUTTER AND DOWNSPOUT SIZE VALIDATED PER IPC1106

DESIGN CRITERIA

ULTIMATE WIND SPEED (Vult) 115 MPHEXPOSURE BUPLIFT RATINGS ZONE 1 75 PSF ZONE 2 105 PSF ZONE 3 135 PSFBASIS OF DESIGN FM 1-90

PROJECT DIRECTORYOWNERIOWA DEPARTMENT OF ADMINISTRATIVE SERVICES (DAS)109 EAST 13TH STREETDES MOINES, IA 50319OWNER'S REPRESENTATIVE: JOSH HERMANPHONE: 515.725.1293EMAIL: [email protected]

CONSTRUCTION MANAGERTHE SAMUELS GROUP2929 WESTON PARKWAY SUITE 200WEST DES MOINES, IA 50266PROJECT MANAGER: JERRY DEHNKEPHONE: 515.518.6576EMAIL: [email protected]

ARCHITECTHORIZON ARCHITECTURE3116 ALPINE COURT IOWA CITY IA 52245PHONE: (563) 506-4965CONTACT: MICHAEL NOLAN, AIAEMAIL: [email protected]

DAS 9200.00 DOC MPCF NORTHPENTHOUSE, VR ENTRY AND SHIFT

CAPTAIN ROOFMOUNT PLEASANT CORRECTIONAL FACILITY

MOUNT PLEASANT, IA

Page 2: DAS 9200.00 DOC MPCF NORTH PENTHOUSE, VR ENTRY AND …

MAR

KD

ATE

DES

CR

IPTI

ON

PROJECT NO:

DRAWN BY:COPYRIGHT

DATE:

SHEET TITLE

A-1

ROOF PLANS

#Pln

MSN5/24/2021

1200

Eas

t W

ashi

ngto

n Str

eet

Mt

Plea

sant

, IA

526

41

C:\

Use

rs\m

iken

\One

Drive

- H

oriz

on A

rchi

tect

ure\

My

Drive

\Hor

izon

\DAS M

t Pl

easa

nt\D

AS M

t Pl

easa

nt.p

ln

DA

S 9

20

0.0

0 D

OC

MP

CF

NO

RTH

PEN

THO

US

E, V

R E

NTR

Y A

ND

SH

IFT

CA

PTA

IN R

OO

F

ISSU

ED F

OR

BID

DIN

G A

ND

CO

NST

RU

CTI

ON

COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC.

MIC

HAEL

@H

ORIZ

ON

-ARCH

ITEC

TURE.

CO

MPH

| (

563)

506

-496

5W

WW

.HO

RIZ

ON

-ARCH

ITEC

TURE.

CO

M

COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture.

8 7/8" 24'-7 1/8" 8 1/2"

8 1/

2"17

'-9"

8 1/

2"

REMOVE AND RETAINGUTTER FOR

REINSTALLATION

REMOVE AND DISPOSE OFROOF MEMBRANE,

TERMINATIONS, BLOCKING ANDEPS INSULATION. PREPARE

DECK TO RECEIVE NEW ROOF.

TYP

INSPECT GUTTER. REMOVEAND RETAIN GUTTER FORREINSTALLATION IFSERVICEABLE.

INSTALL NEW GUTTERAND DOWNSPOUT.

INSTALL WALKWAYMAT OUTSIDEWINDOW (2' DEEP)

REMOVE AND DISPOSE OFROOF MEMBRANE,

TERMINATIONS, BLOCKING ANDEPS INSULATION. PREPARE

DECK TO RECEIVE NEW ROOF.VERIFY DECK STRUCTURE.

INSPECT ROOF DRAIN -REPLACE WITH RETROFITDRAIN IF REQUIRED (OMGHERCULES RETRODRAIN ORSIMILAR)

REMOVE AND DISPOSE OF ROOF MEMBRANE,TERMINATIONS, GRAVEL STOP, BLOCKING AND

INSULATION. REMOVAL AND RESETTING OFRAZOR WIRE BY OWNER. PREPARE DECK TO

RECEIVE NEW ROOF. VERIFY DECKSTRUCTURE.

Slop

e .2

5"/1

2" (m

in)

7A-2

8 7/8" 24'-7 1/8" 8 1/2"

1'-4

"

6 17

/64"

3'-6

"6

17/6

4"3'

-6"

6 23

/64"

3'-6

"

6 17

/64"

3'-6

"

6 23

/64" 1'-2

1/2

"

8 1/

2"17

'-9"

8 1/

2"

22'-2 1/2"

1A-2

4A-2INSTALL NEW GUTTER WITH

DOWNSPOUT ANDSPLASHBLOCK TO LOWER

ROOF

REMOVE OR TEMPORARILYRESUPPORT TOWER ANDASSOCIATED FRAMING. REINSTALLFOLLOWING COPING INSTALLATION.

REMOVE EYE BOLT GUY WIREANCHORAGE. REINSTALL THROUGHNEW COPING AND SEALPENETRATION.

REMOVE CABLE ANDREINSTALL FOLLOWINGCOPING INSTALLATION

STEP COPING

CONTINUOUS COPING -INFILL NOTCHES WITH

POLYISOCYANURATEINSULATION

TYP

Slop

e .2

5"/1

2" (m

in)

1'-1"

1'

1'-1

"12

'-10"

1'-1

"15

'

27'-8 1/2" 1'-1"

26'-8 1/2"

3A-2

1A-2

4A-2

INSTALL NEW GUTTERAND DOWNSPOUT.

INSTALL WALKWAYMAT OUTSIDEWINDOW (2' DEEP)

SUSPECT SEALANTFOR ASBESTOSINVESTIGATION

Slope .25"/12" (min)Sl

ope

.25"

/12"

(min

)

6A-2

13'

27'-8 1/32"

2A-2

5A-2

INSPECT ROOF DRAIN -REPLACE WITH RETROFITDRAIN IF REQUIRED (OMGHERCULES RETRODRAIN ORSIMILAR)

TYP

12 FASTENERS/BOARD(OR AS REQUIRED TO MEET FM 1-90

REQUIREMENTS)

6"2'

-8 1

/4"

1'-7

1/2

"2'

-8 1

/4"

6"

8'

6" 1'-6" 1'-6" 6"

4'

11"

1'-1

0"2'

-6"

1'-1

0"11

"

N

SCALE: 1/4" = 1'-0"1 PENTHOUSE DEMOLITION PLAN0 2' 4' 8'

SCALE: 1/4" = 1'-0"2 SHIFT CAPTAIN DEMOLITION PLAN0 2' 4' 8'

SCALE: 1/4" = 1'-0"3 VR ROOF DEMOLITION PLAN0 2' 4' 8'

SCALE: 1/4" = 1'-0"4 PENTHOUSE ROOF0 2' 4' 8'

SCALE: 1/4" = 1'-0"5 SHIFT CAPTAIN ROOF0 2' 4' 8'

SCALE: 1/4" = 1'-0"6 VR ROOF0 2' 4' 8'

SCALE: 1/2" = 1'-0"7 COVERBOARD FASTENING PATTERN0 1' 2' 4'

GENERAL NOTES

DEMOLITION

1. REMOVE AND DISPOSE OF ALL ROOF MEMBRANE, COVERBOARD, DRIP EDGE, FLASHING, AND DAMAGED ROOF EDGEBLOCKING.

2. PREPARE ROOF SURFACE TO REMAIN TO RECIEVE NEWINSULATION, COVERBOARD AND MEMBRANE.VERIFY DECKSTRUCTURE (ASSUMED TO BE 3" GYPSUM TILE) AND INFORMARCHITECT IF DIFFERENT.

3. ROOF DEMOLITION TO BE COMPLETED IN PHASES IFREQUIRED. ONLY REMOVE ROOF AREA THAT CAN BE EITHERREPLACED OR TEMPORARILY COVERED. TEMPORARYCOVERING TO ENSURE BUILDING IS WATERTIGHTTHROUGHOUT CONSTRUCTION. ANY INTERIOR DAMAGE DUETO LEAKS IN TEMPORARY COVERING WILL BE THERESPONSIBILITY OF THE CONTRACTOR.

4. ALL EDGE COPING TO BE REMOVED.

5. ROOF PENETRATION AND FIXTURE LOCATIONS SHOWNARE APPROXIMATE ONLY. TO BE FIELD LOCATED ANDIDENTIFIED BY CONTRACTOR.

6. DIMENSIONS SHOWN ARE APPROXIMATE AND ARE FORESTIMATING PURPOSES ONLY. VERIFY DIMENSIONS IN FIELD.

7. UNLESS OTHERWISE NOTED, ALL PENETRATIONS,EQUIPMENT AND APPLIANCES TO REMAIN OR BEREINSTALLED.

NEW INSTALLATION

1. ROOF TO BE FULLY ADHERED .060 EPDM MEMBRANE OVERMECHANICALLY FASTENED FIBERGLASS-REINFORCEDPOLYISOCYANURATE COVERBOARD (1/2" ISOGARD HD ORSIMILAR) FASTENED WITH 3" PLATES AND SCREWS ASREQUIRED TO ENSURE FM 1-90 ADHERENCE. BASIS OFDESIGN IS POLYMER SCREWS AND PLATES WITH MIN 2"EMBEDMENT FOR GYPSUM TILE DECK. ALTERNATE ATTACHMENT (ROOFNAV ASSEMBLY262899-0-0 FULLY ADHERED) - INSULATION ANDCOVERBOARD FULLY ADHERED WITH FIRESTONE TWINPACK, ISO STICK OR TWIN JET ADHESIVE (OR OTHERAPPROVED SYSTEMS).

2. INSTALL NEW 5" POLYISOCYANURATE INSULATION OVERENTIRE ROOF SURFACE. NEW INSULATION WILL MEETCURRENT IECC R-30 REQUIREMENT.

3. 12 FASTENERS PER COVERBOARD OR AS REQUIRED TOMEET MANUFACTURER'S REQUIREMENT FOR FM 1-90 UPLIFTCOMPLIANCE.

4. CONTRACTOR RESPONSIBLE FOR WORK REQUIRED TOREMOVE AND REPLACE ANY EXISTING ROOFTOPEQUIPMENT. COORDINATE ANY SERVICE INTERRUPTIONWITH CLIENT AT LEAST 72 HOURS IN ADVANCE.

5. VERIFY POSITIVE SLOPE TO ALL ROOF DRAINS ANDGUTTERS - PROVIDE TAPERED INSULATION AS REQUIRED TOMEET 1/4":1'-0" SLOPE. PROVIDE CRICKETS AS REQUIRED TOENSURE POSITIVE SLOPE AT PARAPET WALL RETURNS.

6. ALL NEW EXPOSED METAL AND ACCESSORIES TO MATCHEXISTING (DARK BRONZE) WHERE APPLICABLE.

INITIALS _______

Page 3: DAS 9200.00 DOC MPCF NORTH PENTHOUSE, VR ENTRY AND …

MAR

KD

ATE

DES

CR

IPTI

ON

PROJECT NO:

DRAWN BY:COPYRIGHT

DATE:

SHEET TITLE

A-2

ROOF DETAILS

#Pln

MSN5/24/2021

1200

Eas

t W

ashi

ngto

n Str

eet

Mt

Plea

sant

, IA

526

41

C:\

Use

rs\m

iken

\One

Drive

- H

oriz

on A

rchi

tect

ure\

My

Drive

\Hor

izon

\DAS M

t Pl

easa

nt\D

AS M

t Pl

easa

nt.p

ln

DA

S 9

20

0.0

0 D

OC

MP

CF

NO

RTH

PEN

THO

US

E, V

R E

NTR

Y A

ND

SH

IFT

CA

PTA

IN R

OO

F

ISSU

ED F

OR

BID

DIN

G A

ND

CO

NST

RU

CTI

ON

COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC.

MIC

HAEL

@H

ORIZ

ON

-ARCH

ITEC

TURE.

CO

MPH

| (

563)

506

-496

5W

WW

.HO

RIZ

ON

-ARCH

ITEC

TURE.

CO

M

COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture.

24 GA STEEL COPING WITH 16GA ANCHOR CLIP, 48" O.C. MAXWRAP MEMBRANE ANDSECURE TO BLOCKINGNEW BLOCKING - ATTACHWITH TAPCON OR SIMILAR

VARIES - SEE PLAN

2" M

IN

EXISTING STRUCTURE -ASSUME 3" GYPSUM TILEROOF DECK

NEW INSULATION - (2) LAYERS 2.5"POLYISOCYANURATE (R-30 MIN)

NEW COVERBOARD - ISOGARD HD (OR SIMILAR)

FULLY ADHERED .060 EPDM MEMBRANE

POLYMER FASTENER AND PLATE - MIN2" EMBEDMENT IN GYPSUM DECK

EXISTING WALL/PARAPETCONSTRUCTION

NEW 1/2" PLYWOOD - TAPCON TO PARAPET WALL

INFILL GAPS AT PENTHOUSEPARAPET WITH INSULATION ANDINSTALL CONTINUOS COPING

TERMINATION BAR ANDCOUNTERFLASHING - STRIKE

MORTAR JOINT, INSTALLCOUNTERFLASHING AND

SEALANT

EXISTING STRUCTURE -ASSUME 3" GYPSUM TILE

ROOF DECK

NEW INSULATION - (2) LAYERS 2.5"POLYISOCYANURATE (R-30 MIN)

NEW COVERBOARD - ISOGARD HD (OR SIMILAR)

FULLY ADHERED .060 EPDM MEMBRANE

POLYMER FASTENER AND PLATE - MIN2" EMBEDMENT IN GYPSUM DECK

EXISTING WINDOW

EXISTING ROOF CONSTRUCTION

EXISTING STRUCTURE -ASSUME 3" GYPSUM TILE

ROOF DECK

NEW INSULATION - (2) LAYERS 2.5"POLYISOCYANURATE (R-30 MIN)

NEW COVERBOARD - ISOGARD HD (OR SIMILAR)

FULLY ADHERED .060 EPDM MEMBRANE

POLYMER FASTENER AND PLATE - MIN2" EMBEDMENT IN GYPSUM DECK

NEW TERMINATION BAR AND DRIPEDGE FLASHING - SEAL AT BASE OF

WINDOW

EXISTING STRUCTURE - ASSUME 3"GYPSUM TILE ROOF DECK

NEW INSULATION - (2) LAYERS 2.5"POLYISOCYANURATE (R-30 MIN)

NEW COVERBOARD - ISOGARD HD (OR SIMILAR)

FULLY ADHERED .060 EPDM MEMBRANE

POLYMER FASTENER AND PLATE - MIN2" EMBEDMENT IN GYPSUM DECK

REINSTALL EXISTING GUTTER

NEW BLOCKING - FASTEN TODECK WITH 1/4" TAPCON @ 12"

O.C., MIN 2" EMBEDMENT

ALUMINUM WRAPPEDFASCIA BOARD (EXISTING

AT PENTHOUSE)

EXISTING STRUCTURE - ASSUME 3"GYPSUM TILE ROOF DECK

NEW INSULATION - (2) LAYERS 2.5"POLYISOCYANURATE (R-30 MIN)

NEW COVERBOARD - ISOGARD HD (OR SIMILAR)

FULLY ADHERED .060 EPDM MEMBRANE

POLYMER FASTENER AND PLATE - MIN2" EMBEDMENT IN GYPSUM DECK

NEW BLOCKING - FASTEN TODECK WITH 1/4" TAPCON @ 12"

O.C., MIN 2" EMBEDMENT

NEW GRAVEL STOP EDGEWITH CONTINOUS CLEAT

DOME STRAINER

ROOF MEMBRANE

COVER BOARD

RIGID INSULATION WITH TAPERED(1/8":1' MIN) (see roof plan)

EVALUATE CONDITION OF EXISTING ROOFDRAIN. IF REPLACEMENT REQUIRED,PROVIDE NEW RETROFIT DRAIN (OMGHERCULES RETRODRAIN OR SIMILAR)

EXPANDABLE COLLAR SEAL

INSULATION

PRIMER

MEMBRANE FLASHING

ROOF MEMBRANEBONDING ADHESIVE OVERCOVER BOARD

CONTINUOUS BEAD OFLAPSEALANT

PIPE

CONTINUOUSBEAD

OF SEALANT

5" FLASHING2"

2"

NOTES:PENETRATION MUST BEANCHORED TO ENSURESTABILITY.

APPLY LAP SEALANT AROUNDENTIRE PERIMETER OFFLASHING.

SEALANT

WATER CUT-OFFMASTIC

LIGHTNING ROD AND BASESUPPORT (OR LADDER, ETC.)

DRILLED MASONRY ANCHOR(TAPCON OR SIMILAR)

SCALE: 1 1/2"= 1'-0"1 PARAPET COPING DETAIL0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0"2 TERMINATION AND COUNTERFLASHING DETAIL

0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0"3 ROOF TERMINATION AT WINDOW SILL0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"4 GUTTER EDGE DETAIL0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0"5 GRAVEL STOP EDGE DETAIL

0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"6 ROOF DRAIN DETAIL0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0"7 PIPE PENETRATION DETAIL

0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"8 VERTICAL ATTACHMENT DETAIL0 6'' 12'' 18''

ALTERNATE ATTACHMENT (ROOFNAV ASSEMBLY262899-0-0 FULLY ADHERED) - INSULATION AND

COVERBOARD FULLY ADHERED WITH FIRESTONETWIN PACK, ISO STICK OR TWIN JET ADHESIVE (OROTHER APPROVED SYSTEMS) IN LIEU OF POLYMER