DAO Observations and Instrumentation

20
DAO Observations DAO Observations and and Instrumentation Instrumentation Jason Grunhut Jason Grunhut

description

DAO Observations and Instrumentation. Jason Grunhut. Introduction to the Dominion astrophysical Observatory. Situated on the peak of Observatory Hill in Victoria on Vancouver Island, British Columbia. 19 th mag dark skies Two telescopes available 1.85 m Plaskett f/18 Cassegrain focus - PowerPoint PPT Presentation

Transcript of DAO Observations and Instrumentation

Page 1: DAO Observations  and  Instrumentation

DAO Observations DAO Observations and and

InstrumentationInstrumentation

Jason GrunhutJason Grunhut

Page 2: DAO Observations  and  Instrumentation

Introduction to theIntroduction to theDominion astrophysical Dominion astrophysical

ObservatoryObservatory Situated on the peak of Observatory Hill in Victoria on Situated on the peak of Observatory Hill in Victoria on

Vancouver Island, British Columbia.Vancouver Island, British Columbia. 1919thth mag dark skies mag dark skies Two telescopes availableTwo telescopes available

1.85 m Plaskett 1.85 m Plaskett f/18 Cassegrain focusf/18 Cassegrain focus f/5 modified Newtonian focusf/5 modified Newtonian focus Primarily used for spectroscopyPrimarily used for spectroscopy fully automatic pointing and guidingfully automatic pointing and guiding

1.22 m McKeller telescope1.22 m McKeller telescope Primarily used with CoudPrimarily used with Coudé focus.é focus. Used for both spectroscopy and photometryUsed for both spectroscopy and photometry

Page 3: DAO Observations  and  Instrumentation

The 72’’ Dome and The 72’’ Dome and TelescopeTelescope

Page 4: DAO Observations  and  Instrumentation

Available ResidencesAvailable Residences

Page 5: DAO Observations  and  Instrumentation

The PolarimeterThe Polarimeter• designed and built by Dmitry Monin

• made from commercially available products

• cheap

• installed immediately after spectrograph slit.

• achromatic quarter-wave plate converts light into two orthogonal linear polarizations (vertical/horizontal).

• Ferroelectric Liquid Crystal (FLC) acts as half-wave plate

• voltage controlled

• near instantaneous change (few ns).

• Calcite beam-displacer use to form image on CCD.

Page 6: DAO Observations  and  Instrumentation

The Polarimeter - ContinuedThe Polarimeter - Continued

Take many spectra Take many spectra in two orthogonal in two orthogonal states to remove states to remove instrumental effects.instrumental effects. Best at several Hz Best at several Hz

levellevel Usually use about Usually use about

50-60 shifts.50-60 shifts. Record both Record both

orthogonal states orthogonal states simultaneously.simultaneously.

Page 7: DAO Observations  and  Instrumentation

CCD ImageCCD Image

• Cover 4750-5000 Å

• 0.15 Å/pixel dispersion

• Resolving power of ~10 000

• ~70 G accuracy for 6th magnitude star in about 20 minutes (emission line star) using Fourier cross-correlation

Page 8: DAO Observations  and  Instrumentation

Problem of Charge TrapsProblem of Charge Traps

Page 9: DAO Observations  and  Instrumentation

ReductionsReductions

Reduced and extracted using IRAFReduced and extracted using IRAF Correct for bias and bad pixelsCorrect for bias and bad pixels Each beam is extracted separately Each beam is extracted separately

Matching beams are then combinedMatching beams are then combined Single wavelength calibration is then appliedSingle wavelength calibration is then applied Stokes V is simply calculated from the difference Stokes V is simply calculated from the difference

of the two spectra (no prior normalization)of the two spectra (no prior normalization) Resulting Stokes V and I spectra are normalized.Resulting Stokes V and I spectra are normalized.

Page 10: DAO Observations  and  Instrumentation

Results: 53 CamResults: 53 Cam

Page 11: DAO Observations  and  Instrumentation

Normalized Spectra:Normalized Spectra:53 Cam53 Cam

Page 12: DAO Observations  and  Instrumentation

Normalized Spectra:Normalized Spectra:HD215441HD215441

Page 13: DAO Observations  and  Instrumentation

Field Measurement Field Measurement Comparisons: 53 CamComparisons: 53 Cam

Page 14: DAO Observations  and  Instrumentation

Field MeasurementField MeasurementComparison: HD71866Comparison: HD71866

Page 15: DAO Observations  and  Instrumentation

Field Measurement Field Measurement Comparison: Theta Aur Comparison: Theta Aur

Page 16: DAO Observations  and  Instrumentation

Field Measurement Field Measurement Comparison: HD32633Comparison: HD32633

Page 17: DAO Observations  and  Instrumentation

Field Measurement Field Measurement Comparison: HD10221Comparison: HD10221

Page 18: DAO Observations  and  Instrumentation

Issues and FutureIssues and Future Spurious detections in null-field Spurious detections in null-field

standard stars.standard stars. Procyon, Theta Cep, Sigma AndProcyon, Theta Cep, Sigma And Likely due to poor guiding in Declination.Likely due to poor guiding in Declination. Possibly due to poor alignment of crystal.Possibly due to poor alignment of crystal.

Improved since first tests.Improved since first tests. Regression routine not entirely Regression routine not entirely

suitable as lines are well resolved.suitable as lines are well resolved. Use Fourier Cross-CorrelationUse Fourier Cross-Correlation Use LSD method Use LSD method

Page 19: DAO Observations  and  Instrumentation

THE END

Page 20: DAO Observations  and  Instrumentation

Beautiful VictoriaBeautiful Victoria