DANI Blood Alcohol Content (BAC) System : HSS 86.50 + Master GC 0305.100 012 DANI Master GC - Base Unit 240 V 0305.102 240 OPT 024M - LARGE Split Splitless Injector 0305.102 070 OPT 100M FID Flame Ionization Detector 0310.100 008 DANI HSS 86.50 Plus - Static Headpsace sampler 0310.160 003 Start-up kit for HSS 86.50 Plus 0320.000 012 CLARITY - Chromatography Software 0305.000 001 GC control module for CLARITY 0305.046 003 LAN Connection Kit 3950.000 005 HSS 86.50 Plus Manager, Stand-alone Control SW 9012.001 003 Retention Gap - fused silica - deactivated with HMDS 1m 0.53mm 9012.200 016 Press Fit Y 3-ways 9414.118 006 GC Capillary Column DN-ALC1 30m, 0.32mm, 1.8um 9414.118 007 GC Capillary Column DN-ALC2 30m, 0.32mm, 1.2 um 1154.500 056 Standard Mixture 9291.100 004 Glass Liner for SL/IN Injector Large [set of 5 pcs] 2306.095 020 Ferrule 4M VGR [set of 10 pcs] 2300.095 012 Nut F 4 M [set of 50 pcs] 2308.506 953 Septa SIL 16x3 [set of 50 pcs] 1340.406 000 Wrench 6-7 mm 1250.401 002 Syringe 10 uL 6310.090 061 Support for Columns BAC System Configuration : HSS 86.50 + Master GC Special Price HS Analysis of Ethanol in Blood The determination of ethanol content in blood is one of the most important analysis in forensic toxicology, either in samples from corpses, or in drivers suspected of driving under the influence; in any case, precise and reliable ethanol determination is necessary. Most of the forensic laboratories performing BAC analysis use different technolo- gies among which gas chromatography may not be the main applied technology. For this reason instruments need to require minimum maintenance, easy serviceabi- lity, and safety performance. The headspace extraction technique is preferred due to the minimal contamination produced to the injector and column of the gas chromatograph; this technique for the determination of ethanol has been refined over time, to the extent that is now possible to perform these tests quickly and accurately. High precision with exceptional simplicity and robustness ; Well-established “Valve&Loop“ technique ; Easy method set-up and optimization ; 44-seat sample tray ; Constant incubation time and sample overlapping capabilities ; High system popularity supported by a very large installed base; » » » » » » Valid Until September 30, 2017 Contacts

Transcript of DANI Blood Alcohol Content (BAC) System : HSS 86.50 ... · DANI Blood Alcohol Content (BAC) System...

Page 1: DANI Blood Alcohol Content (BAC) System : HSS 86.50 ... · DANI Blood Alcohol Content (BAC) System : HSS 86.50 + Master GC 0305.100 012 DANI Master GC - Base Unit 240 V 0305.102 240

DANI Blood Alcohol Content (BAC) System :HSS 86.50 + Master GC

0305.100 012 DANI Master GC - Base Unit 240 V0305.102 240 OPT 024M - LARGE Split Splitless Injector0305.102 070 OPT 100M FID Flame Ionization Detector0310.100 008 DANI HSS 86.50 Plus - Static Headpsace sampler0310.160 003 Start-up kit for HSS 86.50 Plus0320.000 012 CLARITY - Chromatography Software0305.000 001 GC control module for CLARITY0305.046 003 LAN Connection Kit 3950.000 005 HSS 86.50 Plus Manager, Stand-alone Control SW9012.001 003 Retention Gap - fused silica - deactivated with HMDS 1m 0.53mm9012.200 016 Press Fit Y 3-ways9414.118 006 GC Capillary Column DN-ALC1 30m, 0.32mm, 1.8um9414.118 007 GC Capillary Column DN-ALC2 30m, 0.32mm, 1.2 um1154.500 056 Standard Mixture9291.100 004 Glass Liner for SL/IN Injector Large [set of 5 pcs]2306.095 020 Ferrule 4M VGR [set of 10 pcs]2300.095 012 Nut F 4 M [set of 50 pcs]2308.506 953 Septa SIL 16x3 [set of 50 pcs]1340.406 000 Wrench 6-7 mm1250.401 002 Syringe 10 uL6310.090 061 Support for Columns

BAC System Configuration : HSS 86.50 + Master GC

Special Price

HS Analysis of Ethanol in BloodThe determination of ethanol content in blood is one of the most important analysis in forensic toxicology, either in samples from corpses, or in drivers suspected of driving under the influence; in any case, precise and reliable ethanol determination is necessary. Most of the forensic laboratories performing BAC analysis use different technolo-gies among which gas chromatography may not be the main applied technology. For this reason instruments need to require minimum maintenance, easy serviceabi-lity, and safety performance.The headspace extraction technique is preferred due to the minimal contamination produced to the injector and column of the gas chromatograph; this technique for the determination of ethanol has been refined over time, to the extent that is now possible to perform these tests quickly and accurately.

High precision with exceptional simplicity and robustness ;

Well-established “Valve&Loop“ technique ;

Easy method set-up and optimization ;

44-seat sample tray ;

Constant incubation time and sample overlapping capabilities ;

High system popularity supported by a very large installed base;

»

»

»

»

»

»