Danfoss Distribution Systemheating.danfoss.com/PCMPDF/VLKSQ102_Danfoss... · Distribution Systems...
Transcript of Danfoss Distribution Systemheating.danfoss.com/PCMPDF/VLKSQ102_Danfoss... · Distribution Systems...
G GT GTC GTW
Distribution SystemsDistributions Systems for Floor Heating.
Prefabricated solutions for floor heating.
ApplicationThe Danfoss distribution systems are prefabricated solutions for floor heat-ing, which can be installed separately or be implemented with the Danfoss flat station range, in connection with a boiler or as an extension of an existing heating system. These solutions make it easier for the installer to order a ready-made plug & play construction for mounting of distribution pipes for the building sec-tion.
The systems are available as standard solutions with 3, 5 or 7 connections, however, more connections are possi-ble, up to 14, on request.
In addition the solutions GTC, GTW and GT include a shunt with a circulation pump as well as a Danfoss FTC self-act-ing thermostat for control of the supply temperature.An electronic weather compensator for control of the supply temperature is available as an option.
An electric safety thermostat ensures maximum temperature limitation in the floor heating circuit, and protects
the floor heating circuit from overheat-ing.
The distribution systems are available as built-in variants with a recess box as an option, or as wall-mounted variants with a white cover as an option.
Recess boxes for built-in variants are available in two variants, - in width 600 mm for built-in variants with up to 7 connections and in width 1000 mm for built-in variants with up to 14 connec-tions.
DescriptionType G: Distribution system for floor heating without shunt. The built-in variant is available with 3, 5, or 7 connections, if air valve and drain valve are mounted.
Type GT: Distribution system for floor heating with integrated shunt with circulation pump and FTC thermostat for control of supply temperature. The built-in variant is available with 3, 5, or 7 connections, if air valve and drain valve are mounted.
Type GTC: Distribution system for floor heating with integrated shunt with
circulation pump and FTC thermostat for control of supply temperature. With hard-wired master controller FH-WC as standard. The built-in variant is available with 3, 5, or 7 connections, if air valve and drain valve are mounted. Type GTW: Like GTC, however, with wireless master controller CF-MC as standard. The built-in variant is available with 3, 5, or 7 connections, if air valve and drain valve are mounted.
OptionsFor solutions with flat station please refer to product sheets for the TDP-F range for further technical informa-tion.
VL.KS.Q1.02 © Danfoss 08/2007
FEATURES AND BENEFITS• Minimum space required for installa-
tion
• Minimum time required for installation
• Plug & Play construction
1342
(w. b
ase)
1342
(w/o
bas
e)
Distribution SystemsCircuit diagram
Danfoss Redan A/S · District Heating · Sindalsvej 33-35 ·DK-8240 RisskovTel.: +45 87 43 89 43 · Fax: +45 87 43 89 44 · [email protected] · www.redan.danfoss.dk
VL.KS.Q1.02 © Danfoss 08/2007 DKDHR
HESupply
HESupply
Technical parameters:Nominal pressure: PN 10DH supply temperature: T
max= 90°C
Weight: 26,0 kg(incl. packing)
Electrical supply: 230 V AC
Dimensions (mm):H 653 x W 600 x D 150W 600 = Max. 7 connectionsW 1000 = Max. 14 connections
Pipes dimensions:HE: 18 mm
Connections sizes:HE: G ¾” (IG)
Options:• Recess box, for built-in variant• White cover, for wall-mounted variant• Free combination of floor heating, radiator heating cold water and hot water circuit connections
HEReturn
6 Non-return valve 7 Ball valve10 Circulation pump19 Air / drain valve25 El. box33 Thermostat Danfoss RA-C/FTC 15-
50°C43 Connection for radiator57 Safety thermostat 58 Manifold w. 7 connecting pieces
HE Supply
HE Return
7 Ball valve19 Air / drain valve43 Connection for radiator58 Manifold w. 7 connecting pieces
HESupply
HEReturn
6 Non-return valve 7 Ball valve10 Circulation pump19 Air / drain valve25 El. box33 Thermostat Danfoss RA-C/FTC
15-50°C43 Connection for radiator57 Safety thermostat 58 Manifold w. 7 connecting pieces90 Master controller Danfoss CF-MC 90A Thermo-actuator Danfoss TWA-A
HEReturn
6 Non-return valve 7 Ball valve10 Circulation pump19 Air / drain valve25 El. box33 Thermostat Danfoss RA-C/FTC
15-50°C43 Connection for radiator57 Safety thermostat 58 Manifold w. 7 connecting pieces90 Master controller Danfoss FH-WC 90A Thermo-actuator Danfoss TWA-A
• 2-12 floor heating circuit connections• 2-12 hot water connections• 2-12 radiator connections• Danfoss floor heating controls fully connected• Master controller FH-WC with timer• Ball valve 60 mm• Ball valve 120 mm• Room thermostat FH-WT 6-30 °C
Flat station with distribution system- wall-mounted variant
Flat station with distribution system- built-in variant Recess box for built-in variant
DH
W
HE
supp
ly
HE
retu
rn
Cir
c.
DH
sup
ply
DH
retu
rn
DC
W in
let
DC
W o
utle
t
DH
WH
E su
pply
HE
retu
rn
Cir
c.
DH
sup
ply
DH
retu
rn
DC
W in
let
DC
W o
utle
t
DHW
HE supply
HE return
Circ.DH supply
DH returnDCW inlet
DCW outlet
GTW
GTC
GT
G