Danalock v2 euro-white-box-quickmount

2
EURO version quickmount page 1 In the danalock box there’s 4 different metal back plates. A, B and C is for US deadbolt doors. U is for EURO and SCANDI doors. This is the one you normally have to use on European doors. You can mount the plate in two ways: A: Place the back plate on your door so the tailpiece sticks out from the center hole. Break or cut the cylinder-screws from the danalock package so they fit the distance, and fasten the back plate to the cylinder. Use the two holes beneath the center hole.(c) First you have to remove your current door lock. Start on the outside of the door by removing the rosette and the screw. (a) Remember to unscrew the lock-screw in the mortisse-plate at the side of the door. (b) In the danalock box you’ll find 4 extra lock cylinders. Measure the back part of the cylinder (green on illustration) with your old cylinder from the middle of the screwhole and away from the tailpiece. Use the one that matches the cylinder you removed from your door. The new cylinder should be the same length or a little shorter than the old one. 1. Remove the current door lock Remove the rosette and unscrew the remaining screw on the inside of the door. Save the screw for later use. Insert your key and turn it so the cam lines up with the body of the cylinder. Now you can pull out the cylinder. Insert the cylinder you chose, and re-insert the lock-screw in the mortisse-plate to fix the cylinder. (b) 5. Insert the new cylinder 6. Choose the right back plate B: Insert one of the screws that originally held the lock, and insert the threaded tube from the danalock package to extend the second screw. Now you can finally fasten the second screw on the outside of the door. 9. Mounting the back plate on the door version B - fasten the last screw a b b cam c 4. Cylinder lenght Control that the new cylinder doesn’t stick out from the door plate. 8. Mounting the back plate on the door version B 7. Mounting the back plate on the door version A 2. Take out the cylinder 3. Choose your new cylinder

Transcript of Danalock v2 euro-white-box-quickmount

Page 1: Danalock v2 euro-white-box-quickmount

EURO version quickmount page 1

In the danalock box there’s 4 different metal back plates.

A, B and C is for US deadbolt doors.

U is for EURO and SCANDI doors. This is the one you normally have to use on European doors.

You can mount the plate in two ways:

A: Place the back plate on your door so the tailpiece sticks out from the center hole.

Break or cut the cylinder-screws from the danalock package so they fit the distance, and fasten the back plate to the cylinder.

Use the two holes beneath the center hole.(c)

First you have to remove your current door lock. Start on the outside of the door by removing the rosette and the screw. (a)

Remember to unscrew the lock-screw in the mortisse-plate at the side of the door. (b)

In the danalock box you’ll find 4 extra lock cylinders.

Measure the back part of the cylinder (green on illustration) with your old cylinder from the middle of the screwhole and away from the tailpiece.

Use the one that matches the cylinder you removed from your door.

The new cylinder should be the same length or a little shorter than the old one.

1. Remove the current door lock

Remove the rosette and unscrew the remaining screw on the inside of the door. Save the screw for later use.

Insert your key and turn it so the cam lines up with the body of the cylinder.

Now you can pull out the cylinder.

Insert the cylinder you chose, and re-insert the lock-screw in the mortisse-plate to fix the cylinder. (b)

5. Insert the new cylinder

6. Choose the right back plate

B: Insert one of the screws that originally held the lock, and insert the threaded tube from the danalock package to extend the second screw.

Now you can finally fasten the second screw on the outside of the door.

9. Mounting the back plate on the door version B - fasten the last screw

ab

b

cam

c

4. Cylinder lenght

Control that the new cylinder doesn’t stick out from the door plate.

8. Mounting the back plate on the door version B

7. Mounting the back plate on the door version A

2. Take out the cylinder

3. Choose your new cylinder

Page 2: Danalock v2 euro-white-box-quickmount

EURO version quickmount page 2

To power up yourdanalock circle youfirst have to removethe top lid from the housing base.

Use a small flat- head screwdriver to separate the lid from the housing base.

Be gentle whenremoving the lid.

12. Remove the lid

The danalock comes with batteries inserted, but a thin plastic folio guarantees that your new danalock is fully charged.

Remove the folio and the danalock lights up with a green light for 5-10 seconds.

NOTE: This LED is the ONLY light that lights up, after the folio has been removed.

13. Power up the lock

Click the lid gently back on.

16. Click the lid on

You need to calibrate the danalock before you can use it.

After mounting turn the danalock until the the lock is unlocked. Leave the door open, so the lock isn’t influenced while calibrating.

Go to Google Play or App Store and download the danalock App. When you have installed the App and logged in a wizard will guide you through the calibration and adjustments of the danalock.

Note: If the batteries are disconnected, you will have to calibrate the danalock again.

17. Lock/unlock door with User button

Fit the danalock over the back plate.

Make sure that thetailpiece hits the slidein the middle of theadaptor.

14. Fit the tailpiece to the middle of the housing base

1,5 mm

Fasten the danalock to the back plate by tightening the two umbraco screws on each side of the base with an 1,5 mm Allen key.

15. Fasten the danalock

Insert the tailpiece adaptor, that suits the tailpiece on your door in the center tube on the backside of your danalock.

11. Attach the tailpiece adaptor

To avoid damaging the danalock you will have to shorten the new cylinder tailpiece.

It should only extend max. 24 mm from the door surface.

Use two pliers or a wire cutter to shorten the tailpiece.

10. The tailpiece the right size

max 24 mm