11
Daikin Air Conditioning Daikin air conditioners for shops, restaurants and offices. CONCEALED CEILING UNIT UK Price List Attached Correct as of 15/04/08 Please check http://global-cooling.co.uk For the latest information For more information about this range of air conditioning systems http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/concealed-ceiling-airconditioning/ If you need any help please call us on 01200 428888 Or use Live Chat UK Price List Attached Please check the here for latest specifications and prices. Global Cooling Air Conditioning UK www.global-cooling.co.uk Upbrooks Industrial Estate Clitheroe, Lancashire BB7 1PL, UK UK Air Conditioning Online Shop - http://global-cooling.com/ Air Conditioning Forum - http://air-conditioning-forum.global-cooling.co.uk/

description

Concealed ceiling units are built into the false ceiling, leaving only the suction and discharge grilles visible. Because of this the grilles can be placed wherever you want and blend with any interior decor. The grilles allow uniform temperature distribution in large or heavily partitioned areas.Not only are concealed ceiling units visually unobtrusive, they are also among the quietest types of air conditioning.Brochure & UK Prices

Transcript of Daikin Concealed Air Conditioning Ceiling Unit

Page 1: Daikin Concealed Air Conditioning Ceiling Unit

Daikin Air Conditioning Daikin air conditioners for shops, restaurants and offices. CONCEALED CEILING UNIT UK Price List Attached Correct as of 15/04/08 Please check http://global-cooling.co.uk For the latest information

For more information about this range of air conditioning systems http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/concealed-ceiling-airconditioning/ If you need any help please call us on 01200 428888 Or use Live Chat UK Price List Attached Please check the here for latest specifications and prices. Global Cooling Air Conditioning UK www.global-cooling.co.uk Upbrooks Industrial Estate Clitheroe, Lancashire BB7 1PL, UK UK Air Conditioning Online Shop - http://global-cooling.com/ Air Conditioning Forum - http://air-conditioning-forum.global-cooling.co.uk/

Page 2: Daikin Concealed Air Conditioning Ceiling Unit

Daik in a i r condi t ioners

for shops , res taurants and off i ces

CONCEALED CE I L ING UN IT

FBQ-B

ww

w.d

aik

ine

uro

pe

.co

m

hayez_EPLE05-21B 14/03/06 10:02 Page 1

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 3: Daikin Concealed Air Conditioning Ceiling Unit

Wired remotecontrol (Optional)

• You have the choice of 2 fan speeds to select: high or low. A high fan speed providesmaximum reach while a low fan speed minimizes draughts.

• The indoor unit is very quiet in operation. The sound levels are as low as 29dB (A),comparable to rustling leaves.

• Daikin’s special dry programme reduces humidity in the room without variations inroom temperature.

• The indoor unit contains an air filter which removes microscopic particles and dust.

COMFORT

Concealed ceiling units are built into the false ceiling, leaving only thesuction and discharge grilles visible. Because of this the grilles can be placedwherever you want and blend with any interior décor. The grilles allow uniformtemperature distribution in large or heavily partitioned areas.Not only are concealed ceiling units visually unobtrusive, they are also among thequietest types of air conditioning.

hayez_EPLE05-21B 14/03/06 10:02 Page 2

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 4: Daikin Concealed Air Conditioning Ceiling Unit

Wired remotecontrol (Optional)

• The air discharge unit can be separated from the actual air conditioner for use in long,L-shaped or U-shaped rooms by means of flexible duct systems (ESP up to 88Pa).In this way even irregularly shaped rooms can be kept comfortable.

L-shaped room U-shaped room Long room

111

2

2

suction grille

discharge grille (field supply) of the flexible ducts2

1

• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.

• Special anti-corrosion treatment of the outdoor unit’s heat exchanger fin, givesgreater resistance against acid rain and salt corrosion. Additional resistance is providedby a rust proof steel sheet on the underside of the unit.

• Daikin remote controls give you easy control at your fingertips.

• The wired remote control provides you with a schedule timer, enabling to program theair conditioning daily or weekly.

• The optional remote ON/OFF enables you to start/stop the air conditioning from amobile phone via a telephone remote control (field supply). The optional forced OFF enables you to switch off the unit automatically. E.g. when awindow is opened, the unit switches off.

Heat exchanger

An anti-corrosion heatexchanger cutaway view

Aluminium

Hydrophilic film

Corrosion-resistantAcrylic resin

• Since the indoor unit has a low height it fits flush into narrow ceiling voids.The installation of the unit requires a false ceiling of only 350mm (when suction panelis used).

FLEXIBLE INSTALLATION AND EASY TO USE

2

hayez_EPLE05-21B 14/03/06 10:02 Page 3

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 5: Daikin Concealed Air Conditioning Ceiling Unit

ENERGY EFFICIENT

• This model can be used both in cooling only or heating.

• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin,triple, double twin (connecting up to 4 indoors in the same room to a single outdoor)and multi applications (connecting up to 9 units in several rooms to 1 outdoor unit).

APPLICATION OPTIONS

Inverter air conditioning

Non inverterair conditioning

Set point

Large temperaturedifference

Repeats hot and cold cycles

Keeps temperature stable

Startup time reducedby about 1/3

Slow start-up

Improved comfort:The rapid start up time provided by the inverter increases comfort by reducing the leadtime in obtaining the required indoor temperature. As soon as the required temperatureis reached, the inverter unit continuously scans the room for small changes and adjuststhe room temperature in seconds, thereby increasing comfort once again.

• The ‘home leave’ operation button prevents large temperature differences by continuouslyoperating at a minimum (heating mode) or maximum (cooling mode) preset level whileyou’re out or sleeping. It also allows the indoor temperature to return quickly to yourfavourite comfort level.

Smallertemperaturedifference

• Energy label: up to class A

• Inverter technologyImproved energy efficiency:The use of integrated inverter control ensures maximum energy efficiency by supplyingonly the required heating or cooling load where a standard non inverter unit would supplymaximum load in an on/off regime.

When you go out pushthe “Home leave operation”button, and the airconditioner will adjustcapacity to reach the presettemperature for “Homeleave operation”.

When you return, you will bewelcomed by a comfortableair-conditioned room.

Push the “Home leaveoperation” button again,and the air conditioner willadjust capacity to the settemperature for normaloperation.

ONE PUSH PUSH AGAINWhile out of the home

hayez_EPLE05-21B 14/03/06 10:02 Page 4

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 6: Daikin Concealed Air Conditioning Ceiling Unit

Notes:1) Energy label : scale from A (most efficient) to G (less efficient).2) Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)

Capacity and power inputCOOLING ONLY - INVERTER CONTROLLED (air cooled)

Cooling capacity min~nom~max kWNominal input nominal kWEEREnergy labelAnnual energy consumption cooling kWhCOOLING ONLY - NON INVERTER (air cooled)

Cooling capacity nominal kWNominal input nominal kWEEREnergy labelAnnual energy consumption cooling kWhHEAT PUMP - INVERTER CONTROLLED (air cooled)

Cooling capacity min~nom~max kWHeating capacity min~nom~max kWNominal input cooling nominal kW

heating nominal kWEERCOPEnergy label cooling

heatingAnnual energy consumption cooling kWhHEAT PUMP - NON INVERTER (air cooled)

Cooling capacity nominal kWHeating capacity nominal kWNominal input cooling nominal kW

heating nominal kWEERCOPEnergy label cooling

heatingAnnual energy consumption cooling kWh

FBQ35B FBQ50B FBQ60BRKS35D RKS50E RKS60E

3.4 (nom) 0.9~5~5.6 0.9~5.7~61.21 1.92 2.192.81 2.60 2.60

C E E605 960 1,095

FBQ50B FBQ60B FBQ71B FBQ100B FBQ125BRN50E RN60E RR71BV3/W1 RR100BV3/W1 RR125BW1

5 5.7 7.1 10 12.21.92 2.19 2.79/2.68 3.79/3.6 4.672.60 2.60 2.54/2.65 2.64/2.78 2.61

E E D/E D/E D960 1,095 1,395/1,340 1,895/1,800 2,335

FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125BRXS35D RXS50E RXS60E RZQ71B8V3 RZQ100B8V3/BW1 RZQ125B8V3/BW1

3.4 0.9~5~5.6 0.9~5.7~6 7.1 (nom) 10 (nom) 12.5 (nom)4.1 (nom) 0.9~6~7 0.9~7~8 8 (nom) 11.2 (nom) 14 (nom)

1.21 1.92 2.19 2.21 2.86 3.981.28 1.87 2.50 2.09 3 3.992.81 2.60 2.60 3.32 3.50 3.143.20 3.21 2.80 3.21 3.73 3.51

C E E A A BD C E A A B

605 960 1,095 1,105 1,430 1,990FBQ71B FBQ100B FBQ125B

RQ71BV3/W1 RQ100BV3/W1 RQ125BW1

7.1 10 12.28 11.2 14.5

2.79/2.68 3.79/3.6 4.672.49 3.91/3.87 4.52

2.54/2.65 2.64/2.78 2.613.21 2.86/2.89 3.21E/D D/C DC D/D C

1,395/1,340 1,885/1,780 2,335

Notes: (1) The indicated cooling, heating capacities and power input are indicative and are those connected to wall mounted D (25,35 class) /E (50, 60 class) series.(2) For more detailed information, please consult our multi model/combination tables catalogue or your local dealer.*At least two indoor units should be connected to these multi outdoor units.

POSSIBLECOMBINATIONSMULTI - COOLING ONLY

Max. n° of indoor unitsFBQ35BFBQ50BFBQ60B

Max. cooling capacity kWMax. PI cooling kW

Cooling only

4MK

S58E

(1)

4MK

S75E

(1)

5MK

S90E

(1)

• • •• • •• •

4 4 5

7.30 9.28 10.502.24 3.54 3.98

POSSIBLECOMBINATIONSMULTI - HEAT PUMP

Max. n° of indoor unitsFBQ35BFBQ50BFBQ60B

Max. cooling capacity kWMax. heating capacity kWMax. PI cooling kWMax PI heating kW

Heat pump

2MX

S52E

* (1

)

3MX

S52E

* (1

)

4MX

S68E

* (1

)

4MX

S80E

* (1

)

5MX

S90E

* (1

)

RM

XS1

12E*

RM

XS1

40E*

RM

XS1

60E*

• • • • • • • •• • • • • • • •• • • • • •• •

2 3 4 4 5 7 8 9

6.92 7.30 8.68 9.60 10.50 11.2 14.0 15.57.98 8.30 10.64 11.00 11.50 12.5 16.0 17.52.25 2.25 3.69 3.56 4.01 3.50 5.09 5.402.51 2.51 3.41 3.11 3.46 3.93 5.21 5.43

hayez_EPLE05-21B 14/03/06 10:02 Page 5

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 7: Daikin Concealed Air Conditioning Ceiling Unit

FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125B

30 31 41 51 523.5 4.5 6.5

White White White11.5/9 14/10 19/14 19/14 27/20 35/2411.5/9 14/10 19/14 19/14 27/20 35/24

2 steps (direct drive) 3 steps (direct drive)33/29 33/29 34/30 34/30 36/31 38/3233/29 33/29 34/30 34/30 36/31 38/32

52 53 60 60 62 6352 53 60 - - -

ø6.35 ø9.52ø9.52 ø12.70 ø15.9

ø25ø32

Both liquid and gas pipes

COOLING ONLY/HEAT PUMP

Dimensions HxWxD unit mmdecoration panel mm

Weight unit kgdecoration panel kg

Colour decoration panelAir flow rate cooling H/L m3/min

heating H/L m3/minFan speedSound pressure level cooling H/L dB(A)

heating H/L dB(A)Sound power level cooling H dB(A)

heating H dB(A)Piping connections liquid mm

gas mmdrain (VP20) ID mm

OD mmHeat insulation

- information is not available

Specifications indoor units

TWIN/TRIPLE/DOUBLE TWIN APPLICATION

RR/RQ71RR/RQ100RR/RQ125RZQ71RZQ100RZQ125RZQ140RZQ200RZQ250

FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125B

23 2

3 223 24 3 24 3 2

4 3 3 24 2

FBQ35,50,60B, FBQ71B

Indoor units : FBQ-B

FBQ100,125B

hayez_EPLE05-21B 14/03/06 10:02 Page 6

300x700x80055x800x500

300x1,000x80055x1,100x500

300x1,400x80055x1,500x500

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 8: Daikin Concealed Air Conditioning Ceiling Unit

Specifications outdoor units

* Possibility to extend the operation range down to -15°C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20°C or lower and will recover when temperature rises again.- Information is not available.

COOLING ONLY - INVERTER CONTROLLED

Dimensions HxWxD mmWeight kgCasing colourSound pressure level H/L dB(A)Sound power level H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range from ~ to °CDBCOOLING ONLY - NON INVERTER

Dimensions HxWxD mmWeight kgCasing colourSound pressure level H dB(A)Sound power level H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range from ~ to °CDBHEAT PUMP - INVERTER CONTROLLED

Dimensions HxWxD mmWeight kgCasing colourSound pressure level cooling H/L dB(A)(night quiet mode) heating H/L dB(A)Sound power level cooling H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range cooling from ~ to °CDB

heating from ~ to °CWBHEAT PUMP - NON INVERTER

Dimensions HxWxD mmWeight kgCasing colourSound pressure level cooling H dB(A)Sound power level cooling H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range cooling from ~ to °CDB

heating from ~ to °CWB

RKS35D RKS50E RKS60E

550x765x285 735x825x30032 47 47

Ivory white47/44 47/44 49/46

62 61 63hermetically sealed swing type

R-410A0.02 (for piping length > 10m)

20 3015 20

-10~46 -10(-15*)~46RN50E RN60E RR71BV3/W1 RR100BV3/W1 RR125BW1

735x825x300 770x900x320 1,170x900x32047 47 83/81 102/99 106

Ivory white Ivory white47 49 50 53 5361 63 63 66 67

Swing compressorR-410A R-410A

0.02 (piping length > 10m) 2.70 3.70 3.7030 70 (equivalent length 90)20 30

-10~46 -15~46RXS35D RXS50E RXS60E RZQ71B8V3 RZQ100B8V3/BW1 RZQ125B8V3/BW1

550x765x285 735x825x300 770x900x320 1,345x900x32032 48 48 68 106

Ivory white Ivory white47/44 47/44 49/46 47(43) 49(45) 50(45)48/45 48/45 49/46 49/- 51/- 52/-

62 61 63 63 65 66hermetically sealed swing Herm. sealed swing

R-410A R-410A0.02 (for piping length > 10m) 2.8 (for 30m) 4.3 (for 30m)

20 30 50 (equivalent length 70) 75 (equivalent length 95)15 20 30

-10~46 -15~50-15~20 -15~18 -20~15.5

RQ71BV3/W1 RQ100BV3/W1 RQ125BW1

770x900x320 1,170x900x32084/83 103/101 108

Ivory white50 53 5363 66 67

R-410A2.70 3.70 3.70

70 (equivalent length 90)30

-5~46-10~15

hayez_EPLE05-21B 14/03/06 10:02 Page 7

Hermetically sealed scroll compessor

Hermetically sealed scroll compessor

Hermetically sealed scroll compessor

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 9: Daikin Concealed Air Conditioning Ceiling Unit

INDOOR UNITS FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125B

Wired remote control BRC1D52Centralised remote control DCS302C51Unified ON/OFF control DCS301B51Schedule timer DST301B51Adapter for wiring KRP1B54Adapter for external ON/OFF and monitoring KRP4A51Interface adapter for Sky Air DTA112B51Remote ON/OFF, forced OFF EKROROOption PCB for external electrical heater, humidifier EKRP1B2and/or hour meter*

*Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment.

Accessories: control systems

INDOOR UNITS FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125B

Decoration panel BYBS45D BYBS71D BYBS125DService access panel KTBJ25K56W KTBJ25K80W KTBJ25K160WHigh-efficiency filter 65% (colorimetric method)*1 KAFJ252L56 KAFJ252L80 KAFJ252L160High-efficiency filter 90% (colorimetric method)*1 KAFJ253L56 KAFJ253L80 KAFJ253L160Filter chamber for bottom suction KAJ25L56D KAJ25L80D KAJ25L160DFilter chamber for rear suction KAJ25L56B KAJ25L80B KAJ25L160BAir suction canvas KSA-25K56 KSA-25KA80 KSA-25K160Blind board/screening door KBBJ25K56 KBBJ25K80 KBBJ25K160Air discharge adapter for round duct KDAJ25K56 KDAJ25K71 KDAJ25K140

*1 If installing a high-efficiency filter on the unit, an assembly chamber for either bottom or rear suction is required.

Accessories

RKS/RXS35D RN/RKS/RXS50E RN/RKS/RXS60E

KRP937A4 KPW945A4KKP937A4 - -RR/RQ71B RR/RQ100B RR/RQ125B RZQ71B RZQ100B RZQ125B

KKPJ5F180 KKPJ5F180KHRQ22M20TA KHRQ22M20TA

- KHRQ127H - KHRQ127H- - - - - KHRQ22M20TA (x3)- - - KRP58M51

Accessories

Notes: 1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz; V3 = 1~, 230V, 50Hz2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. 7) The sound power level is an absolute value indicating the "power" which a sound source generates.

OUTDOOR UNITS

Air direction adjustment grilleCentral drain plugOUTDOOR UNITS

Central drain plugRefrigerant for twinbranch piping for triple

for double twinDemand adapter kit remote control of sound reduction and power input

EPLE

05-2

1B /

2,175

/ 03

/06

/ La

Mov

ida

Prin

ted

on

no

n-c

hlo

rin

ated

pap

er /

Pri

nte

d i

n B

elg

ium

Daikin products are distributed by:

Zandvoordestraat 300

B-8400 Oostende, Belgium

www.daikineurope.com

Daikin’s unique position as a manufacturerof air conditioning equipment, compressorsand refrigerants has led to its closeinvolvement in environmental issues. Forseveral years Daikin has had the intention tobecome a leader in the provision ofenvironmental friendly products. Thischallenge demands the eco design anddevelopment of a wide range of productsand an energy management system; whichinvolves energy conservation and reductionof waste.

“The present leaflet is drawn up by way of information only anddoes not constitute an offer binding upon Daikin Europe N.V..Daikin Europe N.V. has compiled the content of this leaflet tothe best of its knowledge. No express or implied warranty isgiven for the completeness, accuracy, reliability or fitness forparticular purpose of its content and the products and servicespresented therein. Specifications are subject to change withoutprior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arisingfrom or related to the use and/or interpretation of this leaflet.All content is copyrighted by Daikin Europe N.V.”

Daikin Europe N.V. is approved by LRQA for itsQuality Management System in accordance withthe ISO9001 standard.ISO9001 pertains to quality assurance regardingdesign, development, manufacturing as well as toservices related to the product.

ISO14001 assures an effective environmentalmanagement system in order to help protect humanhealth and the environment from the potentialimpact of our activities, products and services andto assist in maintaining and improving the qualityof the environment.

Daikin units comply with the European regulationsthat guarantee the safety of the product.

Daikin Europe N.V. participates in the EuroventCertification Programme for Air Conditioners (AC),Liquid Chilling Packages (LCP) and Fan Coil Units(FC); the certified data of certified models are listedin the Eurovent Directory. Multi units are Euroventcertified for combinations up to 2 indoor units.

hayez_EPLE05-21B 14/03/06 10:02 Page 8

mov93585_EPLe05-21b

Cyan Magenta Yellow Black

Page 10: Daikin Concealed Air Conditioning Ceiling Unit

Global Cooling Air Conditioning UK Prices*

Daikin Concealed Ceiling Unit – COOLING ONLY TYPES

Features Nom cooling Nom heating Uk cool

UK Cool

Uk heat - - Inter wires - - Max pipe - - - - Price

Daikin Inverter Models Cooling Only types below Min~norm~max Min~norm~max T/C

kw S/C kw kw Run

amps Fuse connecting Liquid Suction separation Max level

min amb

kg in

kg out Exc Vat

FBQ35B+RKS35F Buy it 1.4~3.4~3.8 n/a 3.4 2.6 n/a 5.5 15 3+e 1/4" 3/8" 25 15 -10 18 37 £995.90

FBQ50B+RKS50G Buy it 1.7~5.0~5.6 n/a 5.0 3.5 n/a 7.3 20 3+e 1/4" 1/2" 30 20 -10 18 49 £1133.49

FBQ60B+RKS60F Buy it 1.7~5.7~7.0 n/a 5.7 4.2 n/a 9.3 20 3+e 1/4" 1/2" 30 20 -10 20 53 £1247.06

                                           

*Please check the following page for latest specifications. http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/concealed-ceiling-airconditioning/

Please see the next page for heat pump type prices.

Page 11: Daikin Concealed Air Conditioning Ceiling Unit

Global Cooling Air Conditioning UK Prices*

Daikin Concealed Ceiling Unit – HEAT PUMP TYPES

Features Nom cooling Nom heating Uk cool

UK Cool

Uk heat - - Inter wires - - Max pipe - - - - Price

Daikin Inverter Models Heat Pump types below Min~norm~max Min~norm~max T/C

kw S/C kw kw Run

amps Fuse connecting Liquid Suction separation Max level

min amb

kg in

kg out Exc Vat

FBQ35B+RXS35F Buy it 1.4~3.4~3.7 1.4~4.0~5.0 3.4 2.6 3.0 5.5 15 3+e 1/4" 3/8" 25 15 -10 18 37 £1061.42

FBQ50B+RXS50G Buy it 1.7~5.0~5.6 1.7~6.0~7.0 5.0 3.5 4.4 7.3 20 3+e 1/4" 1/2" 30 20 -10 18 49 £1228.50

FBQ60B+RXS60F Buy it 1.7~5.7~6.0 1.7~7.0~8.0 5.7 4.5 5.1 9.3 20 3+e 1/4" 1/2" 30 20 -10 20 53 £1342.06

                                           