Cytomics FC 500 - Rutgers...

166
Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004) Beckman Coulter, Inc. Fullerton, CA 92835

Transcript of Cytomics FC 500 - Rutgers...

Page 1: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

Cytomics FC 500With CXP Software

Instructions For Use

PN 624923B (June 2004)

Beckman Coulter, Inc.Fullerton, CA 92835

Page 2: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

WARNINGS AND PRECAUTIONS

R E AD AL L PR O D U CT M ANU AL S AND CO NS U L T W IT H BE CK M AN CO U L T E R -T R AINE D PE R S O NNE L BE FO R E AT T E M PT ING T O O PE R AT E INS T R U M E NT . D O NO T AT T E M PT T O PE R FO R M ANY PR O CE D U R E BE FO R E CAR E FU L L Y R E AD ING AL L INS T R U CT IO NS . AL W AY S FO L L O W PR O D U CT L ABE L ING AND M ANU FACT U R E R ’S R E CO M M E ND AT IO NS . IF IN D O U BT AS T O H O W T O PR O CE E D IN ANY S IT U AT IO N, CO NT ACT Y O U R BE CK M AN CO U L T E R R E PR E S E NT AT IV E .

BE CK M AN CO U L T E R , INC. U R G E S IT S CU S T O M E R S T O CO M PL Y W IT H AL L NAT IO NAL H E AL T H AND S AFE T Y S T AND AR D S S U CH AS T H E U S E O F BAR R IE R PR O T E CT IO N. T H IS M AY INCL U D E , BU T IT IS NO T L IM IT E D T O , PR O T E CT IV E E Y E W E AR , G L O V E S , AND S U IT ABL E L ABO R AT O R Y AT T IR E W H E N O PE R AT ING O R M AINT AINING T H IS O R ANY O T H E R AU T O M AT E D L ABO R AT O R Y ANAL Y Z E R .

HAZ ARDS AND OPERATIONAL PRECAUTIONS AND LIMITATIONS

W AR NING S , CAU T IO NS , and IM PO R T ANT S alert y ou as follow s :

WARNING - Can caus e injury .

CAUTION - Can caus e d amag e to th e ins trument.

IMPORTANT - Can caus e mis lead ing res ults .

WARNING R is k of op erator injury if:

r All d oors , covers and p anels are not clos ed and s ecured in p lace p rior to and d uring ins trument op eration.

r T h e integ rity of s afety interlocks and s ens ors is comp romis ed .

r Ins trument alarms and error mes s ag es are not acknow led g ed and acted up on.

r Y ou contact moving p arts .

r Y ou mis h and le b roken p arts .

r D oors , covers and p anels are not op ened , clos ed , removed and /or rep laced w ith care.

r Imp rop er tools are us ed for troub les h ooting .

T o avoid injury :

r K eep d oors , covers and p anels clos ed and s ecured in p lace w h ile th e ins trument is in us e.

r T ake full ad vantag e of th e s afety features of th e ins trument. D o not d efeat s afety interlocks and s ens ors .

r Acknow led g e and act up on ins trument alarms and error mes s ag es .

r K eep aw ay from moving p arts .

r R ep ort any b roken p arts to y our Beckman Coulter R ep res entative.

r O p en/remove and clos e/rep lace d oors , covers and p anels w ith care.

r U s e th e p rop er tools w h en troub les h ooting .

CAUTION S y s tem integ rity mig h t b e comp romis ed and op erational failures mig h t occur if:

r T h is eq uip ment is us ed in a manner oth er th an s p ecified . O p erate th e ins trument as ins tructed in th e Prod uct M anuals .

r Y ou introd uce s oftw are th at is not auth oriz ed b y Beckman Coulter into y our comp uter. O nly op erate y our s y s tem’s comp uter w ith s oftw are auth oriz ed b y Beckman Coulter.

r Y ou ins tall s oftw are th at is not an orig inal cop y rig h ted vers ion. O nly us e s oftw are th at is an orig inal cop y rig h ted vers ion to p revent virus contamination.

IMPORTANT If y ou p urch as ed th is p rod uct from any one oth er th an Beckman Coulter or an auth oriz ed Beckman Coulter d is trib utor, and , if it is not p res ently und er a Beckman Coulter s ervice maintenance ag reement, Beckman Coulter cannot g uarantee th at th e p rod uct is fitted w ith th e mos t current mand atory eng ineering revis ions or th at y ou w ill receive th e mos t current information b ulletins concerning th e p rod uct. If y ou p urch as ed th is p rod uct from a th ird p arty and w ould like furth er information concerning th is top ic, call y our Beckman Coulter R ep res entative.

Page 3: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

iiiPN 624923B

REVISION STATUS

Issu e A, I n itial Issu e, 8 /03CX P S o ftw a r e V e r s io n 1.0 . Initia l is s u e fo r c u s to m e r dis tr ib u tio n.

Issu e B, 6/04CX P S o ftw a r e V e r s io n 2.0 .

A dditio ns , c h a ng e s o r de le tio ns w e r e m a de a t th e s e lo c a tio ns :1-3, 1-5, 1-31, 1-32, 2-1, 2-8 , 2-9, 2-11, 3-1, 3-6, 3-11, 3-13, 4-4, 4-5, 4-7 , 4-9, 4-10 , 4-12, 5-7 , 5-11, 5-15 & 6-10 .

This document applies to the latest software listed and higher versions. When a subsequent software version changes the information in this document, a new issue will be released.

Page 4: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923Biv

REVISION STATUS

Page 5: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B v

CONTENTS

WAR N I N G S AN D PR E CAU TIO N S

R E V ISIO N STATU S, iii

I N TR O D U CTIO N , x iii

U S IN G Y O U R Cy to m ic s F C 50 0 MA N U A LS , x iii

A B O U T T HIS MA N U A L, x iii

CO N V E N T IO N S , x ivT o Ch o o s e A Co m m a nd W ith T h e K e y b o a rd, x vD ia lo g B o x , x vD e s c r ip tio n o f R e p o r ting U nits , x v

G R A P HICS , x v

1 SY STE M O V E R V I E W, 1-1

1.1 IN T E N D E D U S E , 1-1A p p lic a tio ns fo r th e Ins tr u m e nt, 1-2

1.2 CY T O ME T E R CO N T R O LS A N D IN D ICA T O R S , 1-3F C 50 0 F lo w Cy to m e tr y S y s te m , 1-3Cy to m e te r Indic a to r P a ne l, 1-4Cy to m e te r R e a dy a nd La s e r O n Indic a to r s , 1-4S a m p le F lo w R a te Indic a to r s , 1-5S ig na l A m p litu de Indic a to r s , 1-5Le v e l S e ns e a nd F lo w Indic a to r s , 1-6MCL ( Mu lti-tu b e Ca r o u s e l Lo a de r ) , 1-6W o r k s ta tio n, 1-7P o w e r S u p p ly , 1-7P r inte r ( O p tio na l) , 1-7

1.3 MICR O S O F T ® W IN D O W S ® D E S K T O P , 1-8W indo w s 20 0 0 A dm inis tr a to r P a s s w o rd, 1-8T a s k b a r, 1-8S ta r t B u tto n, 1-8R e c y c le B in, 1-9My Co m p u te r, 1-10Co ntr o l P a ne l, 1-10U s ing a Mo u s e , 1-10Co lo r R e s o lu tio n, 1-11

1.4 LE A R N I N G T HE B A S IC O P E R A T IN G T E CHN IQ U E S , 1-13MCL Ca r o u s e ls , 1-13B a r-Co de La b e ls , 1-13P u tting a B a r-Co de La b e l o n a S a m p le T u b e , 1-13P u tting S a m p le T u b e s in a Ca r o u s e l, 1-14P u tting a Ca r o u s e l in th e MCL, 1-14R e m o v ing a Ca r o u s e l fr o m th e MCL, 1-16

Page 6: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923Bvi

CONTENTS

1.5 CX P S O F T W A R E S HO R T CU T S , 1-17K e y b o a rd S h o r tc u ts , 1-17D r a g A nd D r o p , 1-18T o o lb a r B u tto ns , 1-19

1.6 CR E A T IN G P R O T O CO LS , 1-20

1.7 CR E A T IN G R E G I O N S , 1-22Cre a te P o ly g o na l R e g io ns , 1-22Cre a te R e c ta ng u la r R e g io ns , 1-23Cre a te Q u a dr a nt R e g io ns , 1-24

R e p o s itio ning a Q u a dr a nt R e g io n, 1-25Cre a te Line a r R e g io ns , 1-26Cre a te Mu ltip le Line a r R e g io ns , 1-27

1.8 CR E A T IN G G A T E S , 1-28Cre a te A u to G a te , 1-28

Co nv e r t a P o ly g o na l R e g io n to a n A u to G a te R e g io n, 1-30A u to m a tic G a te Cre a tio n, 1-30

1.9 CR E A T IN G F LO W P A G E S , 1-31F lo w P A G E E x a m p le , 1-31D e le te F lo w P A G E S , 1-32

1.10 CR E A T IN G P A N E LS , 1-32U s e P lo ts a nd G a te s fr o m P r e v io u s T e s t, 1-34U s e P lo ts a nd G a te s fr o m P r o to c o l, 1-34U s e Ins tr u m e nt S e tting s , 1-34U s e R e g io ns fr o m P r o to c o l, 1-34Ca r r y R e g io ns fr o m P r e v io u s P r o to c o l, 1-34U s e R e g io ns fr o m T h is P r o to c o l:, 1-34U s e Ins tr u m e nt S e tting s fr o m P r e v io u s T e s t, 1-34U s e Ins tr u m e nt S e tting s fr o m E x te rna l F ile , 1-34P a r a m e te r N a m e s , 1-34

1.11 CR E A T IN G W O R K LIS T S , 1-35W o r k lis t P a ne l, 1-35W o r k lis t T e s t, 1-36

1.12 U S IN G T HE O N LIN E HE LP S Y S T E M, 1-37A c c e s s O nline He lp , 1-37Ho w to U s e He lp , 1-37He lp Me nu , 1-38

CX P He lp , 1-38A b o u t... , 1-38O nline S u p p o r t, 1-38

1.13 P E R F O R MA N CE CHA R A CT E R I S T ICS , 1-38

2 D AIL Y R O U TIN E , 2-1

2.1 B E F O R E Y O U B E G IN , 2-1

Page 7: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B vii

CONTENTS

2.2 D A ILY S T A R T U P , 2-1Ch e c k W a s te a nd R e a g e nt Le v e ls , 2-2P o w e r th e Co m p u te r a nd Cy to m e te r O N , 2-3

T u rning O n P o w e r, 2-3Lo g g ing O nto W indo w s S o ftw a r e , 2-4Lo g g ing O nto CX P S o ftw a r e , 2-4

Ch e c k th e P o w e r S u p p ly , 2-6A dditio na l S ta r t U p Ch e c k s , 2-8

2.3 D A ILY S HU T D O W N , 2-9W h e n to S h u t D o w n th e Cy to m e te r, 2-9B e fo r e P e r fo r m ing S h u t D o w n, 2-9P o w e r th e Co m p u te r a nd Cy to m e te r O F F , 2-9A fte r Ins tr u m e nt S h u t D o w n, 2-11

2.4 E X T E N D E D S HU T D O W N , 2-12

2.5 CY T O ME T E R A U T O S T A R T U P , 2-14

3 Q U AL ITY CO N TR O L , 3-1

3.1 IN T R O D U CT IO N , 3-1

3.2 Q C P R O CE S S E S , 3-1

3.3 D A ILY Q C, 3-2P r e p a r ing A u to S e tu p S a m p le s , 3-2

3.4 A U T O S E T U P S CHE D U LE R , 3-4

3.5 A U T O S E T U P I I W I Z A R D , 3-5B e fo r e R u nning th e A u to S e tu p I I W iz a rd, 3-5

3.6 A P P LICA T IO N D E F I N IT I O N W I Z A R D , 3-10B e fo r e R u nning th e A p p lic a tio n D e finitio n W iz a rd, 3-10S e tting U p Q C P r o du c ts , 3-14E x p o r ting R e g io n R e s u lts T o Q C D a ta b a s e a nd A s s ig ning Q C P r o du c ts , 3-14R e v ie w Q C R e s u lts , 3-15

4 R U N N I N G SAM PL E S, 4-1

4.1 S A MP LE R E Q U IR E ME N T S , 4-1

4.2 B E F O R E R U N N IN G S A MP LE S , 4-1

4.3 R U N N IN G S A MP LE S - MCL A U T O MA T IC MO D E , 4-2

4.4 R U N N IN G S A MP LE S - MCL MA N U A L MO D E , 4-5

4.5 R U N N IN G S A MP LE S - S IN G LE T U B E MO D E , 4-9

5 O PE R ATIO N PR IN CIPL E S , 5-1

5.1 W HA T T HIS CHA P T E R E X P LA IN S , 5-1

Page 8: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923Bviii

CONTENTS

5.2 S A MP LE F LO W , 5-1S a m p le Lo a ding , 5-1Hy dro dy na m ic F o c u s ing , 5-1

5.3 LA S E R B E A M S HA P IN G , 5-3

5.4 CE LL ILLU MIN A T IO N , 5-4F o r w a rd S c a tte r, 5-4S ide S c a tte r a nd F lu o r e s c e nt Lig h t, 5-4

5.5 LIG HT CO LLE CT IO N , S E P A R A T I O N A N D ME A S U R E ME N T , 5-4F o r w a rd S c a tte r Co lle c tio n, 5-4S ide S c a tte r a nd F lu o r e s c e nt Lig h t Co lle c tio n, 5-6

S ide S c a tte r, 5-6F lu o r e s c e nt Lig h t, 5-7

5.6 S IG N A L P R O CE S S IN G , 5-8V o lta g e P u ls e S ig na ls , 5-8

P e a k S ig na l, 5-8Inte g r a l S ig na l, 5-10

A m p lific a tio n, 5-10S ig na ls G e ne r a te d, 5-10

5.7 P R O T O CO LS , 5-11 S p e c ia l P r o to c o ls a nd P a ne ls , 5-11

S p e c ia l P a ne ls , 5-11

5.8 A U T O MA T E D S O F T W A R E F E A T U R E S , 5-12

5.9 P A R A ME T E R S , 5-12A U X ilia r y P a r a m e te r, 5-12

W h e n to U s e th e A U X P a r a m e te r, 5-12T IME P a r a m e te r, 5-12R A T IO P a r a m e te r, 5-13

5.10 P LO T D IS P LA Y , 5-13P R IS M, 5-13R e g io ns , 5-15G a ting , 5-15D a ta S to r a g e , 5-15His to g r a m S ta tis tic s , 5-16

Line a r R e g io n S ta tis tic s , 5-16Lo g R e g io n S ta tis tic s , 5-17Lo g -Lo g Me a n Me th o d, 5-17Lin-Lo g Me a n Me th o d, 5-18

6 TR O U BL E SH O O TIN G , 6-1

6.1 P R E CA U T I O N S /HA Z A R D S , 6-1La s e r /R a dia tio n P r e c a u tio ns , 6-1La s e r W a rning La b e ls , 6-1W a rning La b e ls o n U P S , 6-10

Page 9: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B ix

CONTENTS

D is p o s a l P r e c a u tio n, 6-11

6.2 MA IN T E N A N CE S CHE D U LE S , 6-11Cle a ning S c h e du le , 6-11R e p la c e m e nt S c h e du le , 6-11

6.3 E R R O R ME S S A G E S , 6-11D is p la y Lo c a tio ns , 6-11

CX P S o ftw a r e S c r e e n, 6-11Cy to m e te r S ta tu s Me s s a g e s S c r e e n, 6-12Cy to m e te r.lo g F ile , 6-12

6.4 E R R O R ME S S A G E CY T O ME T E R .LO G F ILE , 6-13Ho w to A c c e s s th e Cy to m e te r.lo g F ile , 6-13

F r o m CX P S o ftw a r e , 6-13F r o m W indo w s D e s k to p , 6-13

Cy to m e te r.Lo g E ntr y D e s c r ip tio n, 6-14Ho w to S e a r c h th e Cy to m e te r.lo g F ile , 6-14O th e r F u nc tio ns A v a ila b le , 6-14

P r int, 6-14Ch a ng e F o nt, 6-14F ind He lp T o p ic s , 6-14

Cy to m e te r a rc h iv e .lo g F ile , 6-14

6.5 E R R O R ME S S A G E S T A B LE , 6-15

6.6 LE V E L S E N S E IN D ICA T O R S , 6-20S h e a th Lo w , 6-20W a s te F u ll, 6-20

6.7 CY T O ME T E R CO N T R O L W IN D O W CA N N O T B E V I E W E D , 6-20

A H O W TO ..., A-1

A .1 S O F T W A R E P R O CE D U R E S , A -1T h e s e p r o c e du r e s a r e in th e S y s te m O v e r v ie w c h a p te r in th e Ins tr u c tio ns F o r U s e Ma nu a l., A -1T h e s e p r o c e du r e s a r e in th e Q u a lity Co ntr o l c h a p te r in th e Ins tr u c tio ns F o r U s e Ma nu a l., A -1T h e s e p r o c e du r e s a r e in th e U s ing CX P S o ftw a r e c h a p te r in th e R e fe r e nc e Ma nu a l., A -1

A .2 HA R D W A R E P R O CE D U R E S , A -1T h e s e p r o c e du r e s a r e in th e S p e c ia l P r o c e du r e s Ma nu a l., A -1

B BAR -CO D E SPE CIFICATIO N S, B-1

B .1 B A R -CO D E S A MP LE ID E N T IF ICA T IO N , B -1

B .2 CO R R E CT P LA CE ME N T O F T HE B A R -CO D E LA B E L, B -1

B .3 B A R -CO D E LA B E L S P E CIF ICA T IO N S , B -2La b e l S iz e a nd T h ic k ne s s , B -2S y m b o l D im e ns io ns , B -3La b e l a nd P r int Q u a lity , B -3

Page 10: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923Bx

CONTENTS

B .4 B A R -CO D E E R R O R R A T E , B -4

B .5 B A R -CO D E S Y MB O LO G IE S , B -5

B .6 B A R -CO D E LA B LE S , B -6B a r-Co de La b e l O p tic a l Ch a r a c te r is tic s a t 67 0 nm ± 10 % , B -6

B .7 MCL B A R -CO D E R E A D E R , B -6

B .8 B A R -CO D E D E CO D E R , B -7

B .9 CHE CK S U M A LG O R IT HM, B -7

R E FE R E N CE S, R E FE R E N CE S-1

IN D E X, IN D E X-1

TR AD E M AR K S

Page 11: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B xi

ILLUSTRATIONS5.1 F lo w Ce ll ( Hy dr o dy na m ic F o c u s ing ) , 5-25.2 La s e r B e a m S h a p ing , 5-35.3 O p tic a l S y s te m w ith O p tio na l R e d S o lid-s ta te La s e r, 5-55.4 O p tic a l S y s te m w ith O p tio na l He N e La s e r , 5-55.5 S ing le La s e r F ilte r B lo c k Co nfig u r a tio n, 5-65.6 D u a l La s e r F ilte r B lo c k Co nfig u r a tio n, 5-75.7 V o lta g e P u ls e F o r m a tio n, P e a k S ig na l, 5-95.8 Inte g r a l a nd P e a k P u ls e s , 5-105.9 P r is m P lo t, 5-146.1 La s e r La b e ls o n th e S e ns ing Co m p a r tm e nt Co v e r, 6-26.2 La s e r La b e ls in th e O p tic a l A r e a , F r o nt V ie w , 6-36.3 La s e r La b e ls in th e O p tic a l A r e a , Inte r io r V ie w , 6-46.4 La s e r La b e ls o n th e A r g o n La s e r He a d, 6-56.5 La s e r La b e ls fo r O p tio na l R e d S o lid-s ta te La s e r, 6-56.6 Lo c a tio n o f th e O p tio na l R e d S o lid-s ta te La s e r in th e Ins tr u m e nt, R e a r V ie w , 6-66.7 La s e r La b e ls fo r O p tio na l R e d He liu m - N e o n La s e r, 6-66.8 Lo c a tio n o f th e O p tio na l R e d He liu m -N e o n La s e r in th e Ins tr u m e nt, R e a r V ie w , 6-76.9 La s e r La b e ls o n th e Cy to m e te r B a c k P a ne l, 6-76.10 La s e r La b e ls o n th e MCL P r o b e Ho u s ing Co v e r, 6-86.11 La s e r La b e ls o n th e MCL B a r-Co de R e a de r, 6-96.12 Inte rna tio na l W a rning S y m b o l Lo c a tio ns , 6-106.13 E r r o r Me s s a g e o n CX P S o ftw a r e S c r e e n, E x a m p le , 6-126.14 Cy to m e te r S ta tu s Me s s a g e s W indo w , E x a m p le , 6-126.15 E x a m p le o f E r r o r Me s s a g e s in Cy to m e te r.lo g F ile , 6-136.16 S h e a th Lo w Indic a to r s , 6-206.17 W a s te F u ll Indic a to r s , 6-20B .1 B a r-Co de La b e l, B -1B .2 B a r-Co de La b e l P la c e m e nt, B -2B .3 B a r-Co de La b e l S p e c ific a tio ns , B -3

Page 12: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B xii

TABLES1.1 A p p lic a tio ns fo r th e Ins tr u m e nt, 1-26.1 Cle a ning S c h e du le , 6-116.2 E r r o r Me s s a g e s , 6-15B .1 B a r-Co de S y m b o lo g ie s , B -5B .2 Co de -R e la te d S p e c ific a tio ns , B -6

Page 13: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B xiii

INTRODUCTION

T h is intr o du c to r y s e c tio n c o nta ins th e fo llo w ing to p ic s :

r U S I N G Y O U R Cy to m ic s F C 50 0 MA N U A LS

r A B O U T T HIS MA N U A L

r CO N V E N T IO N S , a nd

r G R A P HICS .

USING Y OUR Cy tom ics FC 50 0 MANUALST h e m a nu a ls lis te d b e lo w a r e a v a ila b le a s P D F file s in th e F C 50 0 CX P s o ftw a r e a nd th e O p e r a to r ’s Ma nu a ls CD -R O M. P r inte d v e r s io ns o f th e s e m a nu a ls a r e a ls o a v a ila b le b y o rde r.

U s e th e R eferen ce m a nu a l fo r ins tr u m e nt s p e c ific a tio ns a nd info r m a tio n o n ins ta lla tio n a nd s y s te m o p tio ns .

U s e th e I n stru ction s For U se m a nu a l fo r th e da y -to -da y r u nning o f y o u r ins tr u m e nt. G o th r o u g h th e de ta ile d s te p -b y -s te p p r o c e du r e s o f s ta r tu p , q u a lity c o ntr o l ( Q C) , r u nning s a m p le s , a na ly z ing da ta , p r inting r e p o r ts , r e v ie w ing Q C da ta , s h u tdo w n. It c o nta ins s a fe ty a nd tr o u b le s h o o ting info r m a tio n, e r r o r m e s s a g e s , a s w e ll a s in-de p th info r m a tio n o n th e p r inc ip le s o f flo w c y to m e tr y , info r m a tio n a b o u t w h a t y o u r ins tr u m e nt do e s , a nd th e m e th o ds it u s e s .

U s e th e Sp ecial Proced u res m a nu a l to c le a n, r e p la c e , o r a dju s t a c o m p o ne nt o f th e ins tr u m e nt.

U s e th e G ettin g Started m a nu a l a s a b r ie f intr o du c tio n to th e s y s te m .

U s e th e M aster I n d ex to e a s ily lo c a te a to p ic in a ny o f y o u r m a nu a ls .

ABOUT THIS MANUALT h e info r m a tio n in y o u r F C 50 0 Ins tr u c tio ns F o r U s e m a nu a l is o r g a niz e d a s fo llo w s :

r Ch a p te r 1 S Y S T E M O V E R V IE WP r o v ide s th e inte nde d u s e o f th e ins tr u m e nt, th e c o ntr o ls a nd indic a to r s , a nd info r m a tio n o n u s ing th e s y s te m ’s s o ftw a r e a nd W o r k s ta tio n.

r Ch a p te r 2 D A ILY R O U T IN EP r o v ide s info r m a tio n o n do ing da ily p r o c e du r e s , s u c h a s S ta r tu p a nd S h u tdo w n.

r Ch a p te r 3 Q U A LIT Y CO N T R O L P r o v ide s info r m a tio n o n h o w to r u n q u a lity c o ntr o l m a te r ia l to v e r ify ins tr u m e nt s e tu p .

r Ch a p te r 4 R U N N IN G S A MP LE SP r o v ide s info r m a tio n o n h o w to r u n p a tie nt b lo o d s a m p le s .

s Ch a p te r 5, O P E R A T I O N P R I N CIP LE SCo nta ins a de s c r ip tio n o f flo w c y to m e tr y , th e no r m a l s a m p le flo w th r o u g h th e ins tr u m e nt, h o w lig h t c o lle c tio n a nd s ig na l p r o c e s s ing a r e a c c o m p lis h e d a nd h o w th e p a r a m e te r s a r e de r iv e d.

r Ch a p te r 6, T R O U B LE S HO O T IN G

D e s c r ib e s la s e r s a fe ty p r e c a u tio ns a nd th e lo c a tio n o f th e la s e r- r e la te d la b e ls a nd h o w to tr o u b le s h o o t th e s y s te m w ith th e e r r o r m e s s a g e s th a t a p p e a r o n th e s c r e e n.

Page 14: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923Bxiv

INTRODUCTIONCONVENTIONS

s A p p e ndic e sT h e a p p e ndic e s p r o v ide r e fe r e nc e m a te r ia l o n th e fo llo w ing to p ic s :

r HO W T O ...

r B A R -CO D E S P E CIF ICA T IO N S

r IN D E XP r o v ide s p a g e nu m b e r s fo r inde x e d info r m a tio n.

CONVENTIONST h is m a nu a l u s e s th e fo llo w ing c o nv e ntio ns :

r T h r o u g h o u t th is m a nu a l y o u r F C 50 0 is a ls o r e fe r r e d to a s th e s y s te m o r ins tr u m e nt.

r Bold font indic a te s a s o ftw a r e o p tio n, s u c h a s Cy tom eter.

r Italics font indic a te s s c r e e n te x t dis p la y e d o n th e ins tr u m e nt, s u c h a s P reparing S amples.

r Courier font indic a te s te x t y o u h a v e to ty p e u s ing th e k e y b o a rd.

r ë indic a te s a k e y ( s u c h a s Û) .

r ë+ë indic a te s th a t th e tw o k e y s lis te d ( s u c h a s Þ+Ê) a r e link e d fo r a s p e c ific fu nc tio n a nd m u s t b e p r e s s e d in th is s e q u e nc e :

a . P r e s s do w n o n th e fir s t k e y lis te d a nd w h ile c o ntinu ing to p r e s s it, p r e s s do w n o n th e s e c o nd k e y lis te d.

b . R e le a s e b o th k e y s a t th e s a m e tim e .

r ë ë indic a te s to p r e s s a nd r e le a s e th e fir s t k e y lis te d th e n p r e s s a nd r e le a s e th e ne x t k e y lis te d. F o r e x a m p le : Y Û.

r Ic o ns /b u tto ns to s e le c t fu nc tio ns o n th e s o ftw a r e s c r e e n a r e s h o w n w ith in te x t.

E x a m p le : .

r indic a te s to u s e th e m o u s e to s e le c t th e s c r e e n b u tto n la b e le d

. S e e U s ing a Mo u s e .

r File tt Sa v e indic a te s to u s e th e m o u s e to s e le c t th e Sa v e ite m o n th e File m e nu .

r É th r o u g h Ô a r e s p e c ia l fu nc tio n k e y s .

r A N ote c o nta ins info r m a tio n th a t is im p o r ta nt to r e m e m b e r o r h e lp fu l in p e r fo r m ing a p r o c e du r e .

r T h e te r m s “ s c r e e n” a nd “ w indo w ” a r e u s e d inte rc h a ng e a b ly .

r SHOW ME m e a ns th e r e is a v ide o a v a ila b le fo r th e p r o c e du r e in th e o nline h e lp .

Page 15: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B xv

INTRODUCTIONG R A P H ICS

To Ch oose A Com m a nd With Th e Key b oa rd

A fte r y o u p r e s s Þ, e a c h m e nu na m e h a s o ne le tte r u nde r line d to indic a te w h ic h le tte r to u s e to p u ll do w n th e m e nu . F o r e x a m p le , th e le tte r F in th e F ile m e nu is u nde r line d, p r e s s F to p u ll do w n th e F ile m e nu ; th e le tte r E in th e E dit m e nu is u nde r line d, p r e s s E to p u ll do w n th e E dit m e nu .

Dia log Box

D ia lo g b o x e s r e c e iv e c o m m a nds o r info r m a tio n; fo r e x a m p le , a file na m e dia lo g b o x r e c e iv e s info r m a tio n a b o u t a file na m e .

Descrip tion of Rep orting Units

U nle s s o th e r w is e s ta te d, a ll p a r a m e te r u nits a r e s h o w n in th e U S u nit fo r m a t ( c e lls /µ L) th r o u g h o u t th e m a nu a ls .

GRAPHICSA ll g r a p h ic s , inc lu ding s c r e e ns a nd p r into u ts , a r e fo r illu s tr a tio n p u r p o s e s o nly a nd m u s t no t b e u s e d fo r a ny o th e r p u r p o s e .

Comman d Fu n ction

Û A c c e p ts y o u r s e le c tio n.

È S to p s th e o p e r a tio n, dis c a rding y o u r c h o ic e s .

Ù Mo v e s c u r s o r o v e r diffe r e nt c h o ic e s if th e r e a r e m u ltip le o p tio ns - s e e

W indo w s ® m a nu a ls fo r W indo w s o p e r a tio n v ia k e y b o a rd.

Þ+Ù W h e n y o u h a v e m o r e th a n o ne a p p lic a tio n W indo w o p e n, u s e Þ+Ù to s w itc h b e tw e e n ta s k s .

A c c e p ts th e info r m a tio n y o u h a v e s e le c te d o r ty p e d.

S to p s th e o p e r a tio n, ig no r ing y o u r c h o ic e s .

Page 16: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923Bxvi

INTRODUCTIONG R A P H ICS

Page 17: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -1

11SY STEM OVERVIEW

T h e info r m a tio n in th is s e c tio n inc lu de s :

r IN T E N D E D U S E

r CY T O ME T E R CO N T R O LS A N D IN D ICA T O R S

r MICR O S O F T ® W IN D O W S ® D E S K T O P

r LE A R N I N G T HE B A S IC O P E R A T IN G T E CHN IQ U E S

r CX P S O F T W A R E S HO R T CU T S

r CR E A T IN G P R O T O CO LS

r CR E A T IN G R E G I O N S

r CR E A T IN G G A T E S

r CR E A T IN G F LO W P A G E S

r CR E A T IN G P A N E LS

r CR E A T IN G W O R K LIS T S

r U S I N G T HE O N LIN E HE LP S Y S T E M

r P E R F O R MA N CE CHA R A CT E R I S T ICS

1.1 INTENDED USET h e Cy to m ic s F C 50 0 is a s y s te m fo r th e q u a lita tiv e a nd q u a ntita tiv e m e a s u r e m e nt o f b io lo g ic a l a nd p h y s ic a l p r o p e r tie s o f c e lls a nd o th e r p a r tic le s . T h e s e p r o p e r tie s a r e m e a s u r e d w h e n th e c e lls p a s s th r o u g h o ne o r tw o la s e r b e a m s in s ing le - file .

T h e ins tr u m e nt c a n s im u lta ne o u s ly m e a s u r e fo r w a rd s c a tte r, s ide s c a tte r, a nd fiv e flu o r e s c e nt dy e s u s ing o ne o r tw o la s e r s a t 48 8 nm a nd e ith e r 635 nm ( S o lid-s ta te la s e r ) o r 633 nm (He N e la s e r ) . T h e r e fo r e , th e ins tr u m e nt c a n p e r fo r m c o r r e la te d m u ltip a r a m e te r a na ly s e s o f indiv idu a l c e lls .

IMPORTANT T h e us e of th e d ata g enerated b y th is ins trument d ep end s up on th e reg ulatory s tatus of th e reag ents y ou us e. If th e reag ent is lab eled b y th e manufacturer “ For R es earch U s e O nly . Not for us e in d iag nos tic p roced ures ,” U S fed eral law p roh ib its th e us e of th e d ata for d iag nos is .

If, h ow ever, th e reag ent s ub s y s tem is lab eled “ For in vitro d iag nos tic us e,” th e entire s y s tem can b e cons id ered a med ical d evice for g enerating d ata to b e us ed for d iag nos is .

Page 18: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -2

SY STEM OVERVIEWINTEND ED U SE

Ap p lica tions for th e Instrum ent

T h e F C 50 0 is c o ns ide r e d a n e q u iv a le nt s y s te m to th e CO U LT E R ® E P ICS ® X L™ a nd th e CO U LT E R E P ICS X L-MCL™ flo w c y to m e te r s w h e n u s e d w ith th e fo r w a rd s c a tte r F ie ld S to p in th e fa c to r y s e t p o s itio n ( 1-19° ) .

T a b le 1.1 lis ts th e m a ny a p p lic a tio ns fo r th e ins tr u m e nt. In a dditio n to h u m a n c e lls , o th e r c e ll ty p e s c a n b e a na ly z e d, s u c h a s :

r P la nt c e lls

r Ma r ine p la nk to n

r A nim a l c e lls

r B a c te r ia

Ta b le 1.1 Ap p lica tions for th e Instrum ent

Ap p lica tions Cell Ty p es

Sa m p le Prep a ra tion (refer to th e rea g ent's

p a ck a g e insert) Mea surem ents Pa ra m eters

Cell s urface antig ens

W h ole b lood

Buffy coats

M ononuclear cells

D is s ociated tis s ue

Platelets

Bone M arrow

ImmunoPrep ™ reag ents w ith

th e Q -PR E P™ W orks tation,

th e M ulti-Q -Prep ™

W orks tation or th e T Q -Prep ™ W orks tation

W h ole b lood ly s ing reag ent kit

Cell g rad ient s ep aration

Fluores cent-lab eled antib od ies

T h romb o Fix™ p latelet s tab iliz er

Cell s iz e and g ranularity

FIT C, R D 1 , E CD , PC5, PC7 , APC and APC-CY 7 , PC7

Forw ard and s id e s catter (L og /L inear)

Fluores cence one, tw o, th ree, four and five (L og /L inear)

Pris m

R atio

T ime

AU X /Peak

Nucleic acid s W h ole b lood

D is s ociated tis s ue

Froz en s ections

Paraffin s ections

Bod y fluid s

V arious s taining meth od s , includ ing :

E th id ium b romid e

Prop id ium iod id e

D NA Prep reag ents

L eukaS ure™

Cell s iz e and g ranularity

G reen, red , and orang e fluores cence

Forw ard and s id e s catter

Fluores cence one, tw o, th ree, four and five (L og /L inear)

R atio, AU X Peak

K inetics W h ole b lood

Buffy coats

M ononuclear cells

T is s ue culture cells

V arious meth od s , includ ing :

Fluo 3 fluores cence

Cell s iz e and g ranularity

G reen fluores cence

T ime

Forw ard and s id e s catter

Fluores cence one

R atio

T ime

Page 19: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -3

SY STEM OVERVIEWCY TOM ETER CONTR OL S A ND IND ICA TOR S 1

1.2 CY TOMETER CONTROLS AND INDICATORS

FC 50 0 Flow Cy tom etry Sy stem

CH

Cell function W h ole b lood

Buffy coats

M ononuclear cells

T is s ue culture cells

V arious meth od s and d y es , includ ing :

D CFH -D A

D iO C5(3)

FD A

Cell s iz e and g ranularity

G reen fluores cence

Forw ard and s id e s catter

Fluores cence one

R eticulocy tes W h ole b lood T h iaz ole orang e corip h os p h ine O (CPO ) Acrid ine O rang e

Cell s iz e and g ranularity

G reen fluores cence

R ed fluores cence

L og /L inear Forw ard and S id e S catter

L og Fluores cence one

L og Fluores cence four

Ta b le 1.1 Ap p lica tions for th e Instrum ent (Continued)

b

c

d

e

f

g

h

ij 557 1 026B

Page 20: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -4

SY STEM OVERVIEWCY TOM ETER CONTR OL S A ND IND ICA TOR S

Cy tom eter Ind ica tor Pa nel

Cy tom eter Rea d y a nd La ser On Ind ica tors

b MCL g Mo u s e

c Cy to m e te r h U S B b o x

d He N e la s e r o p tio n i Co m p u te r

e K e y b o a rd j P o w e r S u p p ly

f Mo nito r

b B lu e m e a ns th e A r g o n la s e r is o n.

c R e d m e a ns th e r e d la s e r s h u tte r is o p e n.

d G r e e n m e a ns Cy to m e te r is o n a nd in th e R e a dy s ta te .

d c b

Page 21: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -5

SY STEM OVERVIEWCY TOM ETER CONTR OL S A ND IND ICA TOR S 1

Sa m p le Flow Ra te Ind ica tors

Sig na l Am p litud e Ind ica tors

N ote: W h e n b o th lo g a nd line a r p a r a m e te r s a r e s e le c te d fo r th e s a m e s e ns o r, th e a m p litu de dis p la y de fa u lts to th e lo g s ig na l.

b Lo w S a m p le F lo w

c Me diu m S a m p le F lo w

d Hig h S a m p le F lo w

b c d

b F L1 e F L4 h R e d m e a ns o v e r r a ng e

c F L2 f F L5 o r A u x i S S

d F L3 g F S j W h ite indic a te s A u x s o u rc e a nd A u x c h a nne l ( F L5)

b c d e f g

hij

Page 22: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -6

SY STEM OVERVIEWCY TOM ETER CONTR OL S A ND IND ICA TOR S

Lev el Sense a nd Flow Ind ica tors

MCL (Multi-tub e Ca rousel Loa d er)

b S h e a th F lo w

c W a s te F u ll

d S h e a th Lo w

b c d

Page 23: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -7

SY STEM OVERVIEWCY TOM ETER CONTR OL S A ND IND ICA TOR S 1

Work sta tion

Pow er Sup p ly

Y o u r ins tr u m e nt h a s o ne o f th e s e c o nfig u r a tio ns . F o llo w th e p r o c e du r e s in th e do c u m e nta tio n th a t a p p lie s to y o u r P o w e r S u p p ly c o nfig u r a tio n.

Printer (Op tiona l)

T h is m a nu a l do e s no t e x p la in h o w to u s e th e o p tio na l P r inte r. O p e r a ting ins tr u c tio ns fr o m th e P r inte r m a nu fa c tu r e r a r e inc lu de d w ith th e P r inte r.

NEC MultiSync LCD 1700M+

U n iv ersal Power Su p p ly V oltag e-sp ecific Power Su p p ly

SYSTEM POPWER

MCL POPWER

SYSTEM POPWER

MCL POPWER

WATER TRAP

VAC TRAP

AIR FILTER

VAC

FILTER

SY S VAC

SY S PRESS

30 PSI

PRESSADJ

Page 24: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -8

SY STEM OVERVIEWM ICR OSOFT® W IND OW S® D ESK TOP

1.3 MICROSOFT® WINDOWS® DESKTOP

Wind ow s 20 0 0 Ad m inistra tor Pa ssw ord

B e s u r e to m a inta in y o u r W indo w s 20 0 0 A dm inis tr a to r p a s s w o rd in a s e c u r e lo c a tio n. If y o u lo s e o r fo r g e t th e W indo w s 20 0 0 A dm inis tr a to r p a s s w o rd, y o u m u s t r e im a g e y o u r h a rd dr iv e , c a u s ing th e lo s s o f a ll da ta .

Ta sk b a r

A t th e b o tto m o f th e s c r e e n is th e T a s k b a r. It c o nta ins th e S ta r t b u tto n o n th e le ft-h a nd s ide a nd a c lo c k o n th e r ig h t. O th e r ic o ns a r e dis p la y e d o n th e T a s k b a r de p e nding o n th e c o nfig u r a tio n o f th e h a rdw a r e a nd s o ftw a r e o f y o u r p a r tic u la r c o m p u te r.

W h e n a p r o g r a m is o p e ne d, a b u tto n fo r th a t p a r tic u la r p r o g r a m a p p e a r s w ith in th e T a s k b a r.

Y o u c a n s w itc h b e tw e e n p r o g r a m s b y c lic k ing w ith th e m o u s e o n th e s e b u tto ns .

Sta rt Button

T h e S ta r t b u tto n a llo w s y o u to g a in a c c e s s to th e c o m p u te r p r o g r a m s a nd s e tting s . W h e n y o u

c lic k th e m o u s e o n o n th e T a s k b a r, a m e nu a p p e a r s s h o w ing th e c o m p u te r s y s te m ’s m a in p r o g r a m s a nd p r o g r a m g r o u p ic o ns . T h e fo llo w ing CX P s o ftw a r e “ s h o r tc u t” o p tio ns a r e a v a ila b le o n th is D e s k to p Me nu B a r o nly if th e y h a v e b e e n ins ta lle d.

O th e r s ta nda rd W indo w s fu nc tio ns a r e a ls o dis p la y e d a nd th e s e a r e b r ie fly de s c r ib e d b e lo w :

Page 25: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -9

SY STEM OVERVIEWM ICR OSOFT® W IND OW S® D ESK TOP 1

Recy cle Bin

Y o u c a n de le te file s fr o m y o u r c o m p u te r a nd p la c e th e m in th e R e c y c le B in w h e r e y o u c a n, if ne c e s s a r y , r e tr ie v e th e m la te r. Ho w e v e r, if y o u w is h to p e r m a ne ntly r e m o v e file s , th is is a c h ie v e d b y e m p ty ing th e R e c y c le B in.

Prog ra m s: d is p lay s a lis t of p rog rams th at are ins talled on th e comp uter th at y ou can s tart.

Docum ents: lis ts th e mos t recently op ened d ocuments .

Setting s: d is p lay s th e us er-config urab le s y s tem comp onents , includ ing th e Control Panel.

Sea rch : d is p lay s a menu, w h ich allow s y ou to find Files , Fold ers or Comp uters to w h ich y ou are connected if Netw orking .

Help : op ens th e W ind ow s H elp , w h ich p rovid es g uid ance in op erating th e W ind ow s S y s tem.

Run: d is p lay s a s creen d ialog b ox for s tarting or load ing a p rog ram or op ening a file w ith an M S -D O S command .

Sh ut Dow n: d is p lay s a w ind ow d ialog b ox w ith th e op tions for S h utting D ow n th e Comp uter S y s tem, res tarting or oth er s p ecific op tions as d is p lay ed .

Page 26: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -1 0

SY STEM OVERVIEWM ICR OSOFT® W IND OW S® D ESK TOP

My Com p uter

T h e My Co m p u te r ic o n o n th e W indo w s D e s k to p a llo w s a c c e s s to th e c o nte nts o f y o u r c o m p u te r ( ins ta lle d dr iv e s , th e Co ntr o l P a ne l, P r inte r s a nd o th e r ic o ns a s a p p r o p r ia te to th e w a y th e p a r tic u la r c o m p u te r s y s te m w a s c o nfig u r e d) .

Control Pa nel

T h e Control Pa nel h o lds th e to o ls th a t y o u c a n u s e to a lte r th e w a y W indo w s lo o k s a nd w o r k s .

Using a Mouse

T h e Mo u s e , a h a ndh e ld inp u t de v ic e , c o ntr o ls th e m o v e m e nt o f a p o inte r o n th e c o m p u te r s c r e e n. A s th e m o u s e is m o v e d, th e p o inte r m o v e s o n th e s c r e e n. W h e n y o u p o s itio n th e p o inte r o v e r a n o b je c t o n th e s c r e e n, y o u c a n c lic k th e m o u s e b u tto n to do diffe r e nt ta s k s .

If y ou w is h to s ee th e contents of any d rive or fold er, d oub le click th e mous e on its icon. For M icros oft W ind ow s 2000, th e comp uter h ard d is k is know n as C d rive.

T h e Flop p y D rive is D rive A, and any CD -R O M d rive is know n as D D rive unles s W ind ow s as s ig ns anoth er s uitab le letter.

T o view th e Control Pa nel:

Click on Sta rt and p oint th e mous e to S etting s .

Click on th e Control Panel icon.

Note: T h e icons in th e Control Panel vary accord ing to th e p articular h ard w are and s oftw are s etting s for y our comp uter. W h en y ou click on an icon, a s h ort d es crip tion of th e s etting is s h ow n.

D oub le click on an icon to s ee th e s etting th at y ou can ch ang e for th at item.

For a full d es crip tion of th e p os s ib le s etting s , refer to th e M icros oft W ind ow s H elp text and any b ooks or manuals s up p lied w ith y our comp uter s y s tem.

Page 27: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -1 1

SY STEM OVERVIEWM ICR OSOFT® W IND OW S® D ESK TOP 1

Y o u c a n c lic k th e m o u s e b u tto n to s e le c t file s , do u b le c lic k to o p e n a nd w o r k in file s , o r c lic k a nd dr a g to m o v e file s .

A s m o s t fu nc tio ns inv o lv e p o inting a t a n o b je c t o n th e s c r e e n a nd th e n c lic k ing th e m o u s e b u tto n, th e fo llo w ing s h o w s o m e o f th e c o m m o n a c tio ns :

Y o u c a n s w itc h le ft c a nd r ig h t b m o u s e b u tto ns . F o r m o r e info r m a tio n a b o u t u s ing a m o u s e , s e e W indo w s He lp .

T h e CX P s o ftw a r e is u s e d w ith a m o u s e a nd e x c lu s iv e ly u s e s th e le ft m o u s e b u tto n e x c e p t w h e r e s p e c ific a lly indic a te d w ith in th e He lp T e x t.

Color Resolution

F o r th e b e s t r e s u lts , y o u ne e d to r e s e t y o u r c o m p u te r to a c o lo r r e s o lu tio n o f a t le a s t 10 24 x

7 68 p ix e ls a nd Hig h Co lo r ( 16 b it) .

Click : Pres s and releas e th e left mous e b utton c once.

Select: Point at a p articular ob ject and click once.

Doub le-click : Q uickly p res s and releas e th e left mous e b utton c tw ice.

Rig h t-click : Pres s and releas e th e rig h t mous e b utton b once.

Point: M ove th e mous e until th e curs or is over th e d es ired icon or ob ject.

Press: H old d ow n a mous e b utton.

Dra g : H old d ow n th e left mous e b utton c w h ile moving th e mous e.

b

c

1 Clo s e do w n a ny a p p lic a tio ns th a t y o u m a y h a v e r u nning , inc lu ding a ny th a t h a v e b e e n

m inim iz e d o n th e T o o l B a r.

2 S e le c t My Com p uter a nd th e n c h o o s e th e Co ntr o l P a ne l ic o n.

3 F r o m th e Control Pa nel, c h o o s e th e Disp la y o p tio n.

Page 28: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -1 2

SY STEM OVERVIEWM ICR OSOFT® W IND OW S® D ESK TOP

N ote: 3dfx v o o do o b a s e d v ide o c a rds m u s t b e s e t to Hig h Co lo r ( 16 b it) fo r 3D a c c e le r a tio n to fu nc tio n c o r r e c tly .

4 S e le c t th e Setting s ta b .

5 Mo v e th e Screen Area s lide r to s e t 10 24

x 7 68 c o lo r r e s o lu tio n.

6 S e t th e Colors dia lo g b o x u s ing th e dr o p

do w n m e nu to s e t Hig h Co lo r ( 16 b it) .

7 to c o m p le te th e

o p e r a tio n. Y o u m a y ne e d to r e s ta r t th e c o m p u te r ( a dia lo g b o x is dis p la y e d if th is is r e q u ir e d) .

Page 29: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -1 3

SY STEM OVERVIEWL EA R NING TH E B A SIC OP ER A TING TECH NIQ U ES 1

1.4 LEARNING THE BASIC OPERATING TECHNIQUESB e fo r e r e a ding th e o th e r c h a p te r s in th is m a nu a l:

r R e a d a b o u t th e Cy to m e te r Co ntr o l s c r e e ns in th e R e fe r e nc e m a nu a l.

r R e a d th is c h a p te r to b e c o m e e x p e r ie nc e d w ith u s ing th e MCL.

P r a c tic e th e b a s ic te c h niq u e s u ntil y o u fe e l c o m fo r ta b le u s ing th e m . If, la te r o n, y o u ne e d to u s e a b a s ic te c h niq u e b u t c a nno t r e m e m b e r h o w , u s e th e O nline He lp Inde x o r S e a rc h ta b to lo o k it u p a nd g e t th e s te p - b y - s te p ins tr u c tio ns .

MCL Ca rousels

T h e F C 50 0 flo w Cy to m e te r s ta r te r k it h a s :

r T w o c a r o u s e ls , e a c h w ith 32 tu b e p o s itio ns .

r A s h e e t o f b a r- c o de la b e ls , nu m b e r e d 0 1 to 99, fo r y o u to u s e to ide ntify th e c a r o u s e ls .

Ba r-Cod e La b els

Y o u c a n p u t a b a r-c o de la b e l o n e a c h s a m p le tu b e . S e e th e B A R -CO D E S P E CIF ICA T IO N S a p p e ndix .

Putting a Ba r-Cod e La b el on a Sa m p le Tub e

IMPORTANT S amp le mis id entification can occur from th e us e of incorrect, p oor q uality , d amag ed , d irty or imp rop erly p laced b ar-cod e lab els . Follow th e BAR -CO D E S PE CIFICAT IO NS to create y our b ar-cod e lab els to p revent incorrect s amp le id entification. R is k of erroneous res ults if th e b ar-cod e lab el is p laced incorrectly on s amp le tub es . T o p revent mis id entified s amp les , affix th e b ar-cod e lab el as s h ow n b elow s o th e M CL can read th e lab el.

1 Ca re fu lly a lig n th e la b e l w ith th e tu b e .

2 P r e s s th e la b e l do w n s e c u r e ly , inc lu ding

e dg e s a nd c o rne r s , w ith o u t w r ink le s o r fo lds .

b 25.4 m m ( 1.0 in.) m inim u m

c 7 .5 de g r e e s .

b

c

c

Page 30: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -1 4

SY STEM OVERVIEWL EA R NING TH E B A SIC OP ER A TING TECH NIQ U ES

Putting Sa m p le Tub es in a Ca rousel

Putting a Ca rousel in th e MCL

r T h e orientation of a tub e w ith a b ar-cod e lab el b d oes not matter. T h e M CL rotates th e tub e to find th e b ar-cod e lab el.

r D o not s kip tub e p os itions w ith in a p anel. T h e FC 500 flow cy tometer d oes not s kip a p rotocol in a p anel w h en a carous el tub e p os ition is emp ty . If y ou los e a s amp le, d elete th at p rotocol from th e p anel us ing th e Acq uis ition M anag er.

r Y ou can s kip a s ing le-tub e p os ition to s ep arate tw o p anels b as ed on y our tub e location s etup in Acq uis ition M anag er.

b

1 O p e n th e MCL c o v e r.

Page 31: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -1 5

SY STEM OVERVIEWL EA R NING TH E B A SIC OP ER A TING TECH NIQ U ES 1

2 P ic k u p th e c a r o u s e l. Line u p th e

c a r o u s e l w ith its tu rnta b le , a nd th e n p u s h do w n. T h e c a r o u s e l is in h o m e p o s itio n w h e n th e h a ndle p o ints to w a rd th e b a c k .

3 Clo s e th e MCL c o v e r.

Page 32: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -1 6

SY STEM OVERVIEWL EA R NING TH E B A SIC OP ER A TING TECH NIQ U ES

Rem ov ing a Ca rousel from th e MCL

1 O p e n th e MCL c o v e r.

2 R e m o v e th e c a r o u s e l.

Page 33: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -1 7

SY STEM OVERVIEWCX P SOFTW A R E SH OR TCU TS 1

1.5 CX P SOFTWARE SHORTCUTSCX P s o ftw a r e u s e s s e v e r a l s ta nda rd W indo w s te c h niq u e s fo r p r o v iding s h o r tc u ts to fu nc tio ns .

K e y b o a rd S h o r tc u tsD r a g A nd D r o pT o o lb a r B u tto ns

Key b oa rd Sh ortcuts

W h e r e Ý+X m e a ns h o ld Ý do w n a nd p r e s s X.

3 Clo s e th e MCL c o v e r.

Ý+C Co p y

Ý+V P a s te

Ý+X Cu t

Ý+Z U ndo

Ý+Y R e do

Ý+W W o r k s p a c e P r e fe r e nc e s

Ý+T T ile S p e c ia l

Ý+P P r int

Ý+N N e w P r o to c o l

Ý+S S a v e P r o to c o l

Ý+O O p e n Lis tm o de F ile

Ý+F F o r m a t P lo t

Page 34: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -1 8

SY STEM OVERVIEWCX P SOFTW A R E SH OR TCU TS

Dra g And Drop

D r a g g ing a nd dr o p p ing is a s h o r tc u t m e th o d o f o p e ning , m o v ing a nd de le ting file s o r o th e r o b je c ts .

W ith in CX P s o ftw a r e th e D r a g a nd D r o p te c h niq u e c a n b e u s e d fo r s e v e r a l fu nc tio ns , w ith

s o m e o p e r a tio ns Ý c a n b e h e ld do w n to m o dify th e de fa u lt b e h a v io r.

Ý+D D u p lic a te P lo t

Ý+Q Lis tm o de Q u ic k CO MP

Ý+L V ie w Cy to m e te r Lo g

Ý+1 Cre a te ne w D o t P lo t

Ý+2 Cre a te ne w His to g r a m P lo t

Ý+3 Cre a te ne w Co nto u r P lo t

Ý+4 Cre a te ne w D e ns ity P lo t

Ý+5 Cre a te ne w O v e r la y P lo t ( CX P A na ly s is S o ftw a r e o nly )

Ý+6 Cre a te ne w T o m o g r a m P lo t ( CX P A na ly s is S o ftw a r e o nly )

Ý+7 Cre a te ne w S u r fa c e P lo t ( CX P A na ly s is S o ftw a r e o nly )

Ý+8 Cre a te ne w P r is m P lo t

Ý+9 Cre a te ne w Le g e nd P lo t

Ý+0 Cre a te ne w Info P lo t

Þ+Ì E x it CX P s o ftw a r e

É Co nte x t S e ns itiv e He lp

Í R e fr e s h S c r e e n

Ï P u b lis h to E x c e l ( o r te x t file )

Ñ S ta r t A c q u is itio n

Ò S to p A c q u is itio n

Ó P a u s e A c q u is itio n

Ô A b o r t A c q u is itio n

Dra g From … Action

Resource Ex p lorer

W orklis t D rag a s tored W orklis t to Acq uis ition M anag er.

Panels Ad d a p anel to th e current W orklis t b y d rag g ing a p anel to th e current W orklis t.

Protocols D rag a p rotocol to th e W orks p ace or Acq uis ition M anag er.

L is tmod e files D rag a file to a s eries of p lots , or w ith Ý p res s ed O NL Y th e current p lot.

H is tog ram files D rag h is tog rams to an overlay p lot.

Protocol Ex p lorer

Page 35: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -1 9

SY STEM OVERVIEWCX P SOFTW A R E SH OR TCU TS 1

Toolb a r Buttons

T o o lb a r s fo r m a n e s s e ntia l p a r t o f th e CX P s o ftw a r e . T h e a p p lic a tio n e nte r e d a nd th e m o de y o u a r e o p e r a ting a t th e tim e de te r m ine s w h e th e r a p a r tic u la r T o o lb a r dis p la y is a v a ila b le .

T o o lb a r s c a n b e m o v e d u s ing th e D r a g a nd D r o p m e th o d w ith th e m o u s e a r o u nd th e CX P s o ftw a r e de s k to p o r c u s to m iz e d to s u it th e p r e fe r e nc e s o f e a c h u s e r. S e e , T o o lb a r s - Cu s to m iz e T o o lb a r s in th e R e fe r e nc e m a nu a l.

T h e T o o lb a r e le m e nts a r e :

F ILE O P T IO N S T O O LB A R

P LO T O P T I O N S T O O LB A R

R E G I O N S O P T IO N S T O O LB A R

G A T E , CO LO R , S T A T S A N D HE LP T O O LB A R

F LO W P A G E T O O LB A R

A CQ U IS I T IO N MA N A G E R T O O LB A R

A U T O MA T O R T O O LB A R

O V E R LA Y T O O LB A R ( A na ly s is o nly )

CY T O ME T E R T O O LB A R .

G ates D rag a g ate to g ate AL L p lots on a reg ion, or w ith Ý p res s ed O NL Y th e current p lot.

AutoMATOR Setup

R earrang e files R eord er files for p lay b ack us ing th e AutoM AT O R ap p lication.

Mod ify Color Preced ence

R eord er G ates D rag g ates into th e req uired p reced ence ord er.

Plots

R eg ions D rag cop ies of reg ions from one p lot to anoth er, w ith Ý p res s ed g ate log ic is als o cop ied .

Plot Imag es D rag th e current p lot imag e to a th ird p arty ap p lication (s uch as , M S Paint, Pow er

Point®).

O verlay Plot R eord er h is tog rams in th e overlay .

S tatis tics R eord er th e s tatis tics und er th e p lots .

Tile Sp ecia l

Plots R eord er p lots on th e d es ktop .

Cy tom eter Control (Cy tom eter Only )

Parameters R eord er p arameters in th e “ s elected Parameter” lis t.

Acq uisition Ma na g er

W orklis t Columns R eord er W orklis t columns to any d es ired ord er.

Dra g From … Action

Page 36: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -20

SY STEM OVERVIEWCR EA TING P R OTOCOL S

1.6 CREATING PROTOCOLS

1 File tt New tt New Protocol.

2 a nd Pa ra m eters b u tto n o n th e Cy to m e te r Co ntr o l A c q u is itio n S e tu p T a b .

3 Ch o o s e th e P a r a m e te r s to b e a c q u ir e d a nd .

4 If th e p a r a m e te r s h a v e c h a ng e d,

a . .

b . E nte r th e p a r a m e te r na m e a nd .

c . o n th e Cy to m e te r Co ntr o l s c r e e n.

5 Cre a te th e P lo ts r e q u ir e d fo r a c q u is itio n.

6 If a na ly s is is to b e p e r fo r m e d du r ing a c q u is itio n, c r e a te th e r e q u ir e d R e g io ns a nd G a te s ,

a nd a ls o s e le c t th e r e q u ir e d s ta tis tic s fr o m th e Ana ly sis tt Select Results o p tio n.

Page 37: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -21

SY STEM OVERVIEWCR EA TING P R OTOCOL S 1

7 File tt Sa v e Protocol As to s a v e th e p r o to c o l.

8 E nte r th e s a m p le info r m a tio n into th e c o r r e c t p o s itio n in th e A c q u is itio n Ma na g e r

W o r k lis t. S e e A c q u is itio n Ma na g e r in th e R e fe r e nc e m a nu a l to m o dify th e A c q u is is tio n Ma na g e r dis p la y .

9 S e t th e lis tm o de file na m e o p tio ns fr o m th e W o r k s p a c e P r e fe r e nc e s - LMD F ile N a m e ta b .

10 S e t th e a c q u is itio n o p tio ns fr o m th e W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns ta b .

11 S e t u p th e W o r k lis t a nd r u n s a m p le s .

12 S e tu p Mo de o n th e Cy to m e te r Co ntr o l A c q u is itio n S e tu p T a b a nd a dju s t th e

ins tr u m e nt s e tting s o n th e Cy to m e te r Co ntr o l D e te c to r T a b .

13 W h e n s a tis fie d w ith th e da ta , , de s e le c t S e tu p Mo de a nd c o ntinu e a c q u is itio n.

14 O nc e s u ffic ie nt da ta is c o lle c te d, File tt Sa v e Protocol to u p da te th e p r o to c o l w ith th e

ne w ins tr u m e nt s e tting s .

Page 38: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -22

SY STEM OVERVIEWCR EA TING R EG IONS

1.7 CREATING REGIONSCre a te P o ly g o na l R e g io nsCre a te R e c ta ng u la r R e g io nsCre a te Q u a dr a nt R e g io nsCre a te Line a r R e g io ns

Crea te Poly g ona l Reg ions

S e e a ls o : Inte r a c tiv e P o ly g o na l R e g io n E diting in th e R e fe r e nc e m a nu a l.

1 Hig h lig h t a du a l p a r a m e te r p lo t ( c lic k o n th e title b a r ) .

2 .

3 A P o ly g o na l R e g io n c u r s o r is dis p la y e d o n s c r e e n.

4 P la c e th e c u r s o r a t th e p o int w h e r e y o u w a nt th e R e g io n to b e g in.

5 Clic k a nd r e le a s e th e m o u s e b u tto n, to fix th e p o int ( a s ta r t b o x is dis p la y e d o n s c r e e n) .

6 Co ntinu e in th is m a nne r u ntil th e de s ir e d nu m b e r o f p o ints h a s b e e n c h o s e n.

W h e n dr a w ing a R e g io n, if y o u de c ide th a t it is no t th e o ne y o u w a nt, p r e s s È b e fo r e th e r e g io n is c o m p le te d. T h e R e g io n is de le te d.

T o c h a ng e th e R e g io n ty p e , a nd s ta y in th e c u r r e nt w indo w , c h o o s e fr o m th e R e g io n m e nu o r c lic k a R e g io n s h o r tc u t b u tto n fo r w h a te v e r D u a l P a r a m e te r R e g io n ty p e y o u w is h .

Page 39: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -23

SY STEM OVERVIEWCR EA TING R EG IONS 1

Crea te Recta ng ula r Reg ions

S e e a ls o : Inte r a c tiv e R e c ta ng u la r R e g io n E diting in th e R e fe r e nc e m a nu a l.

7 Clo s e th e R e g io n b y r e tu rning th e

c u r s o r to th e s ta r ting b o x a nd c lic k ing to c o nc lu de R e g io n c r e a tio n.

8 T h e R e g io n N a m e a p p e a r s o n th e p lo t.

9 S e e D o t P lo t D a ta S o u rc e to dis p la y p e r c e nta g e s w ith th e R e g io n na m e .

1 Hig h lig h t a du a l p a r a m e te r p lo t.

2 .

3 A R e c ta ng u la r R e g io n c u r s o r a p p e a r s in th e h ig h lig h te d p lo t.

4 P o s itio n th e c u r s o r to th e p o int w h e r e y o u w a nt th e R e g io n to b e g in.

Page 40: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -24

SY STEM OVERVIEWCR EA TING R EG IONS

Crea te Qua d ra nt Reg ions

5 Clic k a nd r e le a s e th e m o u s e b u tto n. A R e c ta ng u la r R e g io n s ta r t b o x is dis p la y e d o n

s c r e e n. B y m o v ing th e m o u s e y o u c a n inc r e a s e a nd de c r e a s e th e s iz e o f th e R e c ta ng u la r R e g io n. W h e n th e de s ir e d R e c ta ng u la r R e g io n a p p e a r s , c lic k th e m o u s e b u tto n to c o m p le te th e R e g io n.

6 T h e R e g io n N a m e a p p e a r s o n th e p lo t.

1 Hig h lig h t a du a l p a r a m e te r p lo t.

2 .

3 A c r o s s h a ir c u r s o r is dis p la y e d in th e c u r r e nt w indo w .

4 P o s itio n th e c u r s o r o n th e p lo t w h e r e y o u w a nt th e inte r s e c tio n p o int o f th e r e g io n a nd

to s h o w th e q u a dr a nt line s ( c r o s s h a ir ) .

5 Mo v e th e r e g io ns to th e r e q u ir e d p o s itio n, if ne e de d, th e n to s e t th is p o s itio n.

Page 41: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -25

SY STEM OVERVIEWCR EA TING R EG IONS 1

W h e n dr a w ing a R e g io n, if y o u de c ide th a t it is no t th e o ne y o u w a nt, p r e s s È b e fo r e th e R e g io n is c o m p le te d. T h e R e g io n is de le te d.

N ote: Q u a dr a nt R e g io n is a s p e c ia l c a s e o f r e c ta ng u la r R e g io ns - fo u r R e c ta ng u la r R e g io ns a r e s im u lta ne o u s ly c r e a te d w ith o ne m o u s e c lic k a nd e x is t th e r e a fte r a s fo u r inde p e nde nt R e c ta ng u la r R e g io ns ( w ith th e e x c e p tio n th a t th e y do no t s a tis fy A u to m a tic G a te Cre a tio n) . D e le ting o ne o r m o r e s till le a v e s r e m a ining R e g io ns inta c t if u s ing R e g io n/V ie w /Mo dify D e le te . I f y o u u s e th e g r a p h ic a l q u a dr a nt de le te , th e n a ll fo u r Q u a dr a nt R e g io ns a r e de le te d a s a g r o u p .

Rep ositioning a Qua d ra nt Reg ion

S e e a ls o : Inte r a c tiv e Q u a dr a nt R e g io n E diting in th e R e fe r e nc e m a nu a l.

6 CX P s o ftw a r e s h o w s th e Q u a dr a nt's na m e in e a c h o f its fo u r R e g io ns .

1 Mo u s e o v e r th e Q u a dr a nt r e g io n line s to g e t th e , o r c u r s o r.

2 R e p o s itio n th e r e g io n.

a . + h o ld a nd dr a g to m o v e th e v e r tic a l div ide r.

b . + h o ld a nd dr a g to m o v e th e h o r iz o nta l div ide r.

c . + h o ld a nd dr a g to m o v e th e Q u a dr a nt r e g io n.

3 R e le a s e th e m o u s e b u tto n.

Page 42: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -26

SY STEM OVERVIEWCR EA TING R EG IONS

Crea te Linea r Reg ions

T h is o p tio n r e q u ir e s tw o p o ints to b e s e t g iv ing a n u p p e r a nd lo w e r c h a nne l b o u nda r y fo r e v e r y R e g io n.

S e e a ls o ( in th e R e fe r e nc e m a nu a l) :Inte r a c tiv e Line a r R e g io n E ditingS ta tu s B a r ( Line a r )X Co o rdina teInte g r a l

1 Hig h lig h t a s ing le p a r a m e te r h is to g r a m .

2 .

A Line a r R e g io n c u r s o r a p p e a r s in th e c u r r e nt w indo w .

3 P o s itio n th e c u r s o r o n th e c h o s e n p lo t to th e p o int w h e r e y o u w a nt th e R e g io n to b e g in.

Clic k , tw o v e r tic a l line s w ith a h o r iz o nta l b a r a p p e a r s .

4 Mo v e th e c u r s o r le ft o r r ig h t, u p o r do w n u ntil th e de s ir e d e nd p o int o f th e R e g io n is

r e a c h e d. to a c c e p t th e s e tting s a nd a nc h o r th e r e g io n.

W h e n dr a w ing a R e g io n, if y o u de c ide th a t it is no t th e o ne y o u w a nt, p r e s s È b e fo r e th e R e g io n is c o m p le te d. T h e R e g io n is de le te d.

A fte r s e tting th e R e g io n p o s itio n, th e lo ng v e r tic a l line s a r e r e p la c e d b y s h o r t c h a nne l m a r k e r s to p r e v e nt c lu tte r ing o f th e p lo t dis p la y .

T h e h o r iz o nta l b a r is p o s itio ne d a p p r o x im a te ly a t th e h o r iz o nta l c u r s o r p o s itio n w h e n th e r e g io n is s e t.

Page 43: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -27

SY STEM OVERVIEWCR EA TING R EG IONS 1

Crea te Multip le Linea r Reg ions

S e e a ls o : Inte r a c tiv e Mu lti-Line a r R e g io n E diting in th e R e fe r e nc e m a nu a l.

1 Hig h lig h t a s ing le p a r a m e te r h is to g r a m a nd .

2 A P a r a lle l c u r s o r a p p e a r s in th e c u r r e nt w indo w .

3 P o s itio n th e c u r s o r o n th e c h o s e n p lo t to th e p o int w h e r e y o u w a nt th e R e g io n to b e g in.

Clic k , tw o v e r tic a l line s w ith a h o r iz o nta l b a r is dis p la y e d. A s to p b o x a p p e a r s in th e r ig h t h a nd to p c o rne r o r th e w indo w .

4 Mo v e th e c u r s o r le ft o r r ig h t, u p o r do w n u ntil th e de s ir e d e nd p o int o f th e R e g io n is

r e a c h e d. to a c c e p t th e s e tting s a nd a nc h o r th e r e g io n.

5 R e p e a t th is p r o c e du r e u ntil a ll R e g io ns a r e s e t.

6 W h e n y o u h a v e dr a w n a ll o f y o u r Mu lti-Line a r R e g io ns , p r e s s È o r m o v e th e c u r s o r

o nto th e s to p b o x in th e r ig h t h a nd to p c o rne r, c lic k . T h is e nds th e Mu lti-Line a r s e q u e nc e .

Page 44: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -28

SY STEM OVERVIEWCR EA TING G A TES

1.8 CREATING GATES

Crea te AutoGa te

N ote: If a s to p c o u nt is u s e d o n a p lo t th a t c o nta ins a n A u to G a te r e g io n, th e s to p c o u nt is no t e x a c t.

1 in th e p lo t y o u w a nt to c r e a te a n

A u to G a te o n.

2 o r .

3 o n th e p o p u la tio n to A u to G a te .

Page 45: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -29

SY STEM OVERVIEWCR EA TING G A TES 1

4 T o s p e c ify th e A u to G a te S e ns itiv ity a nd

T r a v e l,

a . th e r e g io n.

b . Clic k th e r ig h t m o u s e b u tto n o n

th e r e g io n a nd Reg ion

Prop erties.

c . S p e c ify th e A u to G a ting S e ns itiv ity a nd Co nto u r T r a v e l, if ne c e s s a r y ,

a nd .

5 R ig h t m o u s e c lic k o n th e p lo t y o u w a nt

to a s s ig n th e A u to G a te to a nd s e le c t F o r m a t to dis p la y th e P lo t P r o p e r tie s dia lo g .

6 th e g a ting dr o p do w n lis t a nd

s e le c t th e A u to G a te to g a te th e p lo t o n th e A u to G a te .

7 R e p e a t s te p s 5 a nd 6 to a s s ig n th e A u to G a te to o th e r p lo ts o r Ap p ly g a te to a ll p lots.

N ote: I f y o u s e le c t Ap p ly g a te to a ll p lots y o u m u s t g o b a c k to th e p lo t th a t c o nta ins th e A u to G a te a nd u na s s ig n th e A u to G a te fr o m th e p lo t.

Page 46: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -30

SY STEM OVERVIEWCR EA TING G A TES

Conv ert a Poly g ona l Reg ion to a n AutoGa te Reg ion

Autom a tic Ga te Crea tion

1 r e g io n to m a k e it a c tiv e .

2 Clic k th e r ig h t m o u s e b u tto n o n th e r e g io n a nd Reg ion Prop erties.

3 e ith e r Ellip tica l o r Contour in th e P o ly g o na l R e g io n P r o p e r tie s s c r e e n.

T h is o p tio n a llo w s y o u to c r e a te a ne w g a te a u to m a tic a lly w h e n a ne w R e g io n is dr a w n. If th is o p tio n is no t s e le c te d y o u m u s t u s e Ana ly sis tt Crea te Mod ify Ga tes to c r e a te g a ting lo g ic .

R e g io ns c o p ie d u s ing Ý+D r a g

a nd D r o p into a p lo t a s s ig n th e r e g io n a s a g a te .

Page 47: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -31

SY STEM OVERVIEWCR EA TING F L OW P A G ES 1

1.9 CREATING FLOWPAGES

Flow PAGE Ex a m p le

B e lo w is a ty p ic a l e x a m p le o f a F lo w P A G E . T h is is a s c r e e n v ie w o nly . A fu ll p r inte d p a g e o u tp u ts a t a m u c h h ig h e r r e s o lu tio n. S e e a ls o : F lo w P A G E Me nu in th e U s ing CX P S o ftw a r e c h a p te r in th e R e fe r e nc e m a nu a l.

1 to c r e a te a b la nk F lo w P A G E .

2 to ins e r t a p ic tu r e .

3 Ins e r t F lo w p a g e P lo ts .

4 Ins e r t a F lo w P A G E S ta tis tic s T a b le .

5 Ins e r t a F lo w P A G E T e x tb o x .

6 Clic k th e r ig h t m o u s e b u tto n o n a ny

o b je c t o n th e F lo w P A G E to s e le c t a dditio na l fo r m a tting o p tio ns .

Page 48: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -32

SY STEM OVERVIEWCR EA TING P A NEL S

Delete Flow PAGES

1.10 CREATING PANELST h e P a ne l W iz a rd a llo w s y o u to c r e a te a P a ne l fo r u s e in th e A c q u is itio n Ma na g e r.

1 in th e u p p e r le ft c o rne r o f th e

F lo w P A G E w indo w to b e de le te d a nd

Close.

N ote: F lo w P A G E S in a lo c k e d p r o to c o l c a n no t b e ins e r te d, de le te d o r e dite d.

1 File tt New Pa nel to s ta r t th e P a ne l

W iz a rd.

2 E nte r th e N e w P a ne l na m e .

3 S e le c t th e N u m b e r o f T e s ts r e q u ir e d.

T h e de fa u lt v a lu e is 1 a nd th e m a x im u m is 32.

4 Ex p ort th e results of th is p a nel to th e Rep ort Genera tor if y o u w a nt a P a tie nt P a ne l

R e p o r t g e ne r a te d w h e n y o u r u n th is p a ne l. S e e P a ne l R e p o r t in th e R e fe r e nc e m a nu a l.

Page 49: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -33

SY STEM OVERVIEWCR EA TING P A NEL S 1

5 .

6 Ch o o s e y o u r P r o to c o l S e tting s .

U s e P lo ts a nd G a te s fr o m P r e v io u s T e s tU s e P lo ts a nd G a te s fr o m P r o to c o lU s e Ins tr u m e nt S e tting s

7 Ch o o s e y o u r R e g io n S e tting s .

U s e R e g io ns fr o m P r o to c o lCa r r y R e g io ns fr o m P r e v io u s P r o to c o lU s e R e g io ns fr o m T h is P r o to c o l:

.

8 Ch o o s e y o u r Ins tr u m e nt S e tting s .

U s e Ins tr u m e nt S e tting s fr o m P r e v io u s T e s tU s e Ins tr u m e nt S e tting s fr o m E x te rna l F ile

9 D o u b le o n p a r a m e te r na m e s u nde r Prob e/Sta in na m e to a s s ig n th e P a r a m e te r N a m e s .

10 R e p e a t s te p s 6 th r o u g h 9 fo r e a c h te s t.

Page 50: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -34

SY STEM OVERVIEWCR EA TING P A NEL S

Use Plots a nd Ga tes from Prev ious Test

A llo w s y o u to u s e G a te s a nd P lo ts fr o m a p r e v io u s T e s t b u t is no t a c tiv e fo r th e fir s t T e s t w ith in a P a ne l.

T h is o p tio n is no t a v a ila b le if Use p lots a nd g a tes from p rotocol is c h o s e n.

Use Plots a nd Ga tes from Protocol

A llo w s y o u to s e le c t P lo ts a nd G a te s fr o m a s p e c ific P r o to c o l, c h o s e n fr o m th e dr o p do w n lis t b o x .

T h is o p tio n is no t a v a ila b le if Use p lots a nd g a tes from p rev ious test is c h o s e n.

Use Instrum ent Setting s

U s e s th e ins tr u m e nt s e tting s fr o m th e s e le c te d P r o to c o l. I f th e c h e c k b o x is dis a b le d, th is a llo w s th e Instrum ent Setting s b e lo w to b e a c tiv e .

Use Reg ions from Protocol

T h is o p tio n lo a ds a ll r e g io ns s to r e d w ith in th e c u r r e nt p r o to c o l.

Ca rry Reg ions from Prev ious Protocol

S e le c ting th is o p tio n a llo w s r e g io n p o s itio ns to b e c a r r ie d fr o m th e p r e v io u s te s t in a p a ne l. A ny r e g io ns o f th e s a m e ty p e a nd dr a w n o n th e s a m e p a r a m e te r s a r e c a r r ie d.

Use Reg ions from Th is Protocol:

T h is o p tio n lo a ds th e r e g io ns a nd r e g io n p o s itio ns fr o m th e s e le c te d p r o to c o l.

Use Instrum ent Setting s from Prev ious Test

U s e s th e Ins tr u m e nt s e tting s fr o m th e p r e v io u s T e s t b u t is no t a c tiv e fo r th e fir s t T e s t w ith in a P a ne l.

T h is o p tio n is no t a v a ila b le if Use instrum ent setting s from ex terna l file is s e le c te d.

Use Instrum ent Setting s from Ex terna l File

U s e Ins tr u m e nt S e tting s fr o m a n E x te rna l F ile s u c h a s Lis tm o de o r P r o to c o l [ S e tting s ] file s th a t y o u c h o o s e fr o m th e dr o p do w n lis t b o x .

T h is o p tio n is no t a v a ila b le if Use instrum ent setting s from p rev ious test is s e le c te d.

Pa ra m eter Na m es

A llo w s y o u to c h o o s e th e P a r a m e te r N a m e s fo r e a c h tu b e w ith in a P a ne l.

11 .

Page 51: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -35

SY STEM OVERVIEWCR EA TING W OR K L ISTS 1

1.11 CREATING WORKLISTS

N ote: I f no W o r k lis t is v is ib le , View tt Acq uisition Ma na g er to dis p la y th e W o r k lis t p a ne .

N ote: U nle s s th e c u r r e nt W o r k lis t h a s b e e n s a v e d u s ing th e Sa v e Work list b u tto n w ith in th e A CQ U IS I T IO N MA N A G E R T O O LB A R , c u r r e nt w o r k lis t s e tting s a r e no t a v a ila b le .

Work list Pa nel

1 to c r e a te a ne w W o r k lis t o r to c le a r c u r r e nt W o r k lis t fr o m th e A c q u is itio n

Ma na g e r s c r e e n.

2 D r a g A nd D r o p p a ne ls a nd p r o to c o ls fr o m th e R e s o u rc e E x p lo r e r to th e A c q u is itio n

Ma na g e r . Info r m a tio n a dde d in th is w a y a lw a y s a p p e a r s a t th e e nd o f th e W o r k lis t.

3 A fte r a ll th e info r m a tio n h a s b e e n a dde d, y o u c a n u s e D r a g A nd D r o p to c h a ng e th e

o rde r.

1 .

2 S e le c t w h ic h p a ne l y o u w is h to o p e n

a nd .

Page 52: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -36

SY STEM OVERVIEWCR EA TING W OR K L ISTS

Work list Test

to ins e r t a s ing le R o w a t th e e nd o f th e c u r r e nt P a ne l.

3 A fte r a ll th e info r m a tio n h a s b e e n a dde d, y o u c a n u s e D r a g A nd D r o p to c h a ng e th e

o rde r.

Y o u c a n u s e th is o p tio n to a dd a no th e r P a ne l to a n e x is ting W o r k lis t.

Page 53: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 1 -37

SY STEM OVERVIEWU SING TH E ONL INE H EL P SY STEM 1

1.12 USING THE ONLINE HELP SY STEMY o u r Cy to m ic s F C 50 0 s y s te m p r o v ide s a n o nline He lp s y s te m th a t a llo w s y o u to s e a rc h fo r info r m a tio n o n s p e c ific s y s te m - r e la te d to p ic s th r o u g h th e Contents, Ind ex , and Sea rch o p tio ns .

T h e He lp s y s te m is a n e le c tr o nic v e r s io n o f th e Ins tr u c tio ns F o r U s e Ma nu a l, R e fe r e nc e Ma nu a l, a nd S p e c ia l P r o c e du r e s Ma nu a l. It inc lu de s a ta b le o f c o nte nts , a n inde x fo r finding info r m a tio n q u ic k ly , a nd a g lo s s a r y o f de finitio ns .

W h e n y o u a c c e s s th e He lp m e nu , th e r e a r e th r e e o p tio ns a v a ila b le : CX P Help , Ab out..., a nd

Online Sup p ort.

Access Online Help

How to Use Help

U s e o ne o f th e s e o p tio ns to a c c e s s th e o nline He lp s y s te m .

.

Help tt CX P Help .

É.

N ote: I f y o u c a nno t a c c e s s th e o nline He lp s y s te m , c o nta c t y o u r B e c k m a n Co u lte r R e p r e s e nta tiv e .

o n th e He lp N a v ig a tio n B a r.

Info r m a tio n a b o u t th e He lp w indo w a nd ins tr u c tio ns fo r u s ing h e lp a r e dis p la y e d in th e na v ig a tio n p a ne .

b T o o lb a rc N a v ig a tio n B a rd T o p ic P a nee N a v ig a tio n P a ne

Page 54: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B1 -38

SY STEM OVERVIEWP ER F OR M A NCE CH A R A CTER ISTICS

Help Menu

CX P Help

O p e ns th e F C 50 0 CX P o nline h e lp .

Ab out...

D is p la y s :

r CX P s o ftw a r e c o p y r ig h t

r CX P s o ftw a r e v e r s io n info r m a tio n

r R u ntim e P r o to c o l o r N e w P r o to c o l ( w h e n lis tm o de file is r e p la y e d) o r Lo c k e d P r o to c o ls .

r th a t ta k e s y o u to a lis t o f c u r r e nt a na ly s is a lg o r ith m s a nd th e ir de s c r ip tio ns .

If y o u a r e a s k ing fo r te c h nic a l s u p p o r t b y te le p h o ne , fa x , o r e m a il, p le a s e q u o te th e CX P s o ftw a r e b u ild nu m b e r, w h ic h is a c c e s s ib le fr o m m e nu Help tt Ab out..., a nd e ns u r e y o u k no w th e R o m lo c k nu m b e r w h ic h is w r itte n o n th e b o dy o f th e R o m lo c k .

Online Sup p ort

r Beck man Cou lter Web Site

If y o u h a v e a n Inte rne t c o nne c tio n a nd y o u c lic k th e m o u s e o n h ttp ://w w w .b e c k m a nc o u lte r.c o m y o u c a n a c c e s s th e B e c k m a n Co u lte r W e b S ite th r o u g h y o u r W e b B r o w s e r p r o g r a m .

r ACS Web Site

If y o u h a v e a n Inte rne t c o nne c tio n a nd y o u c lic k th e m o u s e o n h ttp ://w w w .a p p lie dc y to m e tr y .c o m y o u c a n a c c e s s th e A p p lie d Cy to m e tr y S y s te m s W e b S ite th r o u g h y o u r W e b B r o w s e r p r o g r a m .

Y o u c a n th e n a c c e s s th e la te s t info r m a tio n c o nc e rning th e u p -to -da te s o ftw a r e r e le a s e s a nd o th e r ite m s o f inte r e s t.

1.13 PERFORMANCE CHARACTERISTICSR e fe r to th e p a c k a g e ins e r t o f th e Q u a lity Co ntr o l Ma te r ia ls lis te d in th e R e fe r e nc e m a nu a l fo r th e p e r fo r m a nc e c h a r a c te r is tic s fo r th e p r e p a r a tio n m e th o d y o u a r e u s ing .

Page 55: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-1

22DAILY ROUTINE

2.1 BEFORE Y OU BEGINT h is c h a p te r e x p la ins th e da ily s ta r tu p p r o c e du r e s . B e fo r e do ing th e s e p r o c e du r e s :

2.2 DAILY STARTUPP e r fo r m th e fo llo w ing s te p s to s ta r t u p th e s y s te m . I f y o u h a v e s e t u p CY T O ME T E R A U T O S T A R T U P a nd th e Cy to m e te r is r u nning , s k ip a h e a d to Ch e c k th e P o w e r S u p p ly .

1 R e a d th e O P E R A T I O N P R IN CIP LE S c h a p te r. U s ing y o u r s y s te m is e a s ie r if y o u h a v e a

g e ne r a l u nde r s ta nding o f h o w it w o r k s .

2 R e a d th e S Y S T E M O V E R V I E W c h a p te r. It c o nta ins ins tr u c tio ns fo r

r CY T O ME T E R CO N T R O LS A N D IN D ICA T O R S

r LE A R N I N G T HE B A S IC O P E R A T IN G T E CHN IQ U E S .

3 R e a d e a c h p r o c e du r e e ntir e ly .

4 If c o nditio ns c a u s e s ta tic c h a r g e to e x is t in y o u r la b , b e s u r e to p r o p e r ly g r o u nd y o u r s e lf

b e fo r e to u c h ing th e ins tr u m e nt.

5 S h u tdo w n a nd r e s ta r t th e s y s te m c o m p u te r o nc e p e r da y to a llo w th e v ir u s p r o te c tio n

p r o g r a m to r u n. S e e P o w e r th e Co m p u te r a nd Cy to m e te r O F F a nd P o w e r th e Co m p u te r a nd Cy to m e te r O N . D o no t s ta r t a fu ll dis k v ir u s s c a n w h ile r u nning CX P s o ftw a r e .

Page 56: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-2

DAILY ROUTINED A IL Y STA R TU P

Ch eck Wa ste a nd Rea g ent Lev els

1 E m p ty th e w a s te c o nta ine r a nd v e r ify

tu b ing is c o nne c te d to th e c a p .

2 Ch e c k th e s h e a th flu id le v e l a nd fill th e

s h e a th c o nta ine r if ne c e s s a r y .

Page 57: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-3

DAILY ROUTINED A IL Y STA R TU P 2

Pow er th e Com p uter a nd Cy tom eter ON

Turning On Pow er

3 Ch e c k th e c le a ning a g e nt fill le v e l b

a nd fill th e c le a ning a g e nt c o nta ine r if ne c e s s a r y .

b

T u rn o n th e s y s te m a t th e c o m p u te r.

Page 58: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-4

DAILY ROUTINED A IL Y STA R TU P

Log g ing Onto Wind ow s Softw a re

Log g ing Onto CX P Softw a re

W h e n th e Log on to Wind ow s s c r e e n a p p e a r s ,

a . Ch e c k th a t th e User na m e fie ld dis p la y s Administrator o r y o u r W indo w s lo g - in u s e r na m e . If no t, ty p e in y o u r u s e r na m e .

N ote: W h e n fir s t ins ta lling th e s o ftw a r e , th e User na m e fie ld m u s t dis p la y Administrator.

b . E ns u r e th e c h e c k b o x is u nc h e c k e d.

c . E nte r y o u r P a s s w o rd a nd

.

N ote: I f y o u r c o m p u te r is p a r t o f a ne tw o r k , y o u m a y ne e d to e nte r th e U s e r na m e a nd P a s s w o rd a s s ig ne d b y y o u r ne tw o r k m a na g e r.

1 to s ta r t th e

s o ftw a r e a nd p o w e r u p th e Cy to m e te r.

A llo w a b o u t 40 m inu te s to w a r m u p th e s y s te m b e fo r e p e r fo r m ing Q C o r r u nning s a m p le s .

Page 59: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-5

DAILY ROUTINED A IL Y STA R TU P 2

2 A t th e CX P Cy tom eter Sta rtup Wiz a rd [Pa g e

1 of 2] s c r e e n:

a . Hig h lig h t y o u r U s e r I D .

b . E nte r y o u r P a s s w o rd.

c . .

N ote: F o r a dditio na l info r m a tio n a b o u t th is s c r e e n, s e e MU LT I-U S E R S IG N O N . I f y o u ne e d to s e t u p U s e r I D s , s e e U s e r A dm inis tr a tio n.

3 S e le c t a p r o to c o l, if ne e de d.

4 .

5 D u r ing s y s te m s ta r tu p , th e fo llo w ing s e r ie s o f Cy to m e te r s ta tu s m e s s a g e s a r e dis p la y e d.

T h e s ta r tu p c y c le inc lu de s a p r im e c y c le .

S tartup in P rocessV erificationInitializ ationA waiting S ample

Page 60: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-6

DAILY ROUTINED A IL Y STA R TU P

Ch eck th e Pow er Sup p ly

1 O p e n th e P o w e r S u p p ly do o r a nd c h e c k

th e W A T E R T R A P , A IR F ILT E R , a nd V A Cu u m F ILT E R .

Ca ll y o u r B e c k m a n Co u lte r R e p r e s e nta tiv e if:

r T h e T R A P is > 1/3 fu ll.

r T h e F ILT E R S h a v e a ny flu id.

2 Ch e c k th e S Y S te m V A Cu u m g a u g e . I f it

r e a ds ≥−17 in. Hg , c a ll y o u r B e c k m a n Co u lte r R e p r e s e nta tiv e .

3 Ch e c k th e S Y S te m P R E S S u r e g a u g e . I f

it do e s no t r e a d b e tw e e n 28 a nd 32 p s i, do th e fo llo w ing :

WATER TRAP

VAC TRAP

AIR FILTER

VAC

FILTER

SY S VAC

SY S PRESS

30 PSI

PRESSADJ

-1 0

-5

0

-1 5

-2 0

-2 5

-3 0

> -1 7 " H g

30 ± 2 PS I

5 0

0

2 0

1 0

4 0

6 0

3 0

Page 61: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-7

DAILY ROUTINED A IL Y STA R TU P 2

a . P u ll th e P R E S S u r e A D J u s te r k no b o u t to w a rd y o u .

b . A dju s t th e p r e s s u r e to 30 ± 2 p s i.

b T o de c r e a s e , tu rn to th e le ft.

c T o inc r e a s e , tu rn to th e r ig h t.

c . P u s h in o n th e k no b to lo c k it into p la c e .

PU

LL TO ADJU

ST

PU

LL TO ADJU

ST

b

c

PU

LL TO ADJU

ST

Page 62: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-8

DAILY ROUTINED A IL Y STA R TU P

Ad d itiona l Sta rt Up Ch eck s

4 Ch e c k th e V A Cu u m T R A P .

If it is > 1/4 fu ll o f flu id CLE A N T HE V A CU U M T R A P .

5 Clo s e th e P o w e r S u p p ly do o r.

6 R e c o rd th e s ta r tu p c h e c k s o n th e Ma inte na nc e Lo g o r o n th e A c tio n Lo g S h e e t.

1 Ch e c k th a t th e MCL v o r te x fu nc tio n m ix e s s a m p le s b y r u nning a b la nk s a m p le .

2 R e fe r to th e m a nu a ls th a t c a m e w ith y o u r P r inte r to :

r P e r fo r m P r inte r dia g no s tic s .

r Ch e c k th a t th e r e is a n a de q u a te p a p e r s u p p ly in th e P r inte r.

r Ch e c k ink c a r tr idg e s if y o u h a v e a c o lo r P r inte r a nd r e p la c e if ne c e s s a r y .

WATER TRAP

VAC TRAP

AIR FILTER

VAC

FILTER

SY S VAC

SY S PRESS

30 PSI

PRESSADJ

Page 63: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-9

DAILY ROUTINED A IL Y SH U TD OW N 2

2.3 DAILY SHUTDOWN

Wh en to Sh ut Dow n th e Cy tom eter

r S h u t do w n th e ins tr u m e nt a t le a s t o nc e a da y, e v e n if it is inte nde d fo r u s e 24 h o u r s p e r da y.

r Le a v e th e ins tr u m e nt s h u t do w n fo r a t le a s t 30 m inu te s b e fo r e r e s ta r ting .

r S h u tdo w n a nd r e s ta r t th e s y s te m c o m p u te r o nc e p e r da y to a llo w th e v ir u s p r o te c tio n p r o g r a m to r u n. S e e P o w e r th e Co m p u te r a nd Cy to m e te r O F F a nd P o w e r th e Co m p u te r a nd Cy to m e te r O N . D o no t s ta r t a fu ll dis k v ir u s s c a n w h ile r u nning CX P s o ftw a r e .

Before Perform ing Sh ut Dow n

Pow er th e Com p uter a nd Cy tom eter OFF

1 P e r fo r m th e R o u tine Cle a ning P r o c e du re in th e S p e c ia l P r o c e du re s Ma nu a l.

2 P e r fo r m th e V a c u u m Line Cle a ning P r o c e du re in th e S p e c ia l P r o c e du r e s Ma nu a l.

1 to p u t th e Cy to m e te r in th e Idle m o de .

2 in a ll o p e n w indo w s .

3 o r .

Page 64: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-1 0

DAILY ROUTINED A IL Y SH U TD OW N

4 tt to tu rn o ff th e Cy to m e te r.

5 tt to

s h u tdo w n th e W o r k s ta tio n.

6 W h e n th e Sh ut Dow n Wind ow s s c r e e n

a p p e a r s :

E ns u r e Sh ut d ow n or Sta nd b y a p p e a r s b e lo w Wh a t d o y ou w a nt th e com p uter to

d o?

7 .

T h e Cy to m e te r a u to m a tic a lly tu rns o ff.

8 T u rn o ff th e m o nito r a nd P r inte r s e p a r a te ly .

Page 65: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-1 1

DAILY ROUTINED A IL Y SH U TD OW N 2

After Instrum ent Sh ut Dow n

1 W ip e do w n a ll e x p o s e d s u r fa c e s w ith 10 % b le a c h s o lu tio n a nd th e n 7 0 % e th a no l. P a y

s p e c ia l a tte ntio n to th e S a m p ling a r e a .

2 K e e p th e s y s te m s h u t do w n fo r 30 m inu te s . B e fo r e r u nning s a m p le s , do th e da ily s ta r tu p

a nd q u a lity c o ntr o l p r o c e du r e s .

R e m inde r :

Cle a n th e a ir filte r s o nc e a w e e k .

Cle a n th e s a m p le p r o b e a nd s a m p le h e a d o nc e a w e e k .

Cle a n th e s h e a th flu id c o nta ine r o nc e a m o nth .

Cle a n th e c le a ning a g e nt c o nta ine r e v e r y 60 da y s .

3 R e c o rd da ily s h u tdo w n a nd c le a ning o n th e Ma inte na nc e Lo g o r o n th e A c tio n Lo g

S h e e t.

Page 66: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-1 2

DAILY ROUTINEEX TEND ED SH U TD OW N

2.4 EX TENDED SHUTDOWNIf y o u inte nd to le a v e th e ins tr u m e nt in th e s h u tdo w n s ta te fo r a n e x te nde d a m o u nt o f tim e :

1 R e m o v e th e c le a ning a g e nt a nd s h e a th

flu id c o nta ine r s .

2 R ins e th e ins ide o f b o th c o nta ine r s w ith

w a te r.

Page 67: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-1 3

DAILY ROUTINEEX TEND ED SH U TD OW N 2

3 R e p la c e th e c le a ning a g e nt a nd inte rna l

s h e a th flu id c o nta ine r s . F ill b o th c o nta ine r s w ith w a te r ins te a d o f r e a g e nt.

4 P e r fo r m th e R o u tine Cle a ning

P r o c e du r e . U s e ta p w a te r in tu b e s 1-4 ins te a d o f b le a c h in tu b e 1 a nd Is o F lo w s h e a th flu id in tu b e s 2-4.

5 W h e n y o u s ta r t u p th e ins tr u m e nt fo r

th e fir s t tim e a fte r th e e x te nde d s h u tdo w n,

r Cle a n th e s h e a th flu id c o nta ine r

r Cle a n th e c le a ning a g e nt c o nta ine r

r F ill th e s h e a th flu id c o nta ine r

r F ill th e c le a ning a g e nt c o nta ine r

r P e r fo r m th e R o u tine Cle a ning P r o c e du r e

r P e r fo r m D A ILY Q C b e fo r e r u nning s a m p le s .

Page 68: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-1 4

DAILY ROUTINECY TOM ETER A U TO STA R TU P

2.5 CY TOMETER AUTO STARTUPY o u c a n s e t u p th e s y s te m to a u to m a tic a lly S ta r tu p o r S h u tdo w n th e Cy to m e te r. T h e c o m p u te r m u s t b e o n w ith W indo w s r u nning to a llo w A u to S ta r tu p to r u n.

1 U s ing W indo w s E x p lo r e r, do u b le c lic k

o n C:\CX P \T a s k s .e x e .

2 .

3 O n th e T a s k s c r e e n, e nte r C:\CX P in th e

Sta rt in: fie ld.

Y o u c a n a ls o e nte r c o m m e nts a nd s e t a p a s s w o rd, a lth o u g h th e y a r e no t r e q u ir e d.

Page 69: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 2-1 5

DAILY ROUTINECY TOM ETER A U TO STA R TU P 2

4 to s c h e du le w h e n y o u

w a nt th e S ta r tu p o r S h u tdo w n ta s k to o c c u r.

a nd e nte r y o u r s e tting s .

5 to s p e c ify a dditio na l

s e tting s .

6 If y o u w a nt to s e t u p a u to m a tic Cy to m e te r s h u tdo w n, a nd p e r fo r m

s te p s 3 th r o u g h 5.

Page 70: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B2-1 6

DAILY ROUTINECY TOM ETER A U TO STA R TU P

Page 71: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-1

33QUALITY CONTROL

3.1 INTRODUCTIONP e r fo r m th e fo llo w ing q u a lity c o ntr o l c h e c k s to e ns u r e th a t y o u r s y s te m is w o r k ing a c c u r a te ly a nd p r e c is e ly . T h e p r o to c o ls ne e de d fo r th e s e q u a lity c o ntr o l ( Q C) p r o c e du r e s a r e inc lu de d w ith y o u r s y s te m S o ftw a r e . T h e p a c k a g e ins e r ts fo r y o u r Q u a lity Co ntr o l Ma te r ia ls h a v e ins tr u c tio ns fo r e s ta b lis h ing y o u r la b o r a to r y 's no r m a l r a ng e s fo r da ily u s e .

Y o u m u s t r e -e s ta b lis h y o u r la b o r a to r y 's r a ng e s :

r W h e n y o u u s e a ne w lo t o f flu o r o s p h e r e s .

r W h e ne v e r a m a jo r p a r t o f th e s y s te m h a s b e e n s e r v ic e d o r r e p la c e d ( fo r e x a m p le , la s e r a lig nm e nt o r r e p la c e m e nt, P MT r e p la c e m e nt) .

In a dditio n to do ing th e da ily q u a lity c o ntr o l p r o c e du r e in th is c h a p te r, y o u s h o u ld m a k e a q u a lity c o ntr o l c h e c k fo r th e s p e c ific a p p lic a tio ns y o u a r e r u nning .

3.2 QC PROCESSEST h e c h a r t b e lo w s h o w s w h ic h Q C m a te r ia ls a r e ne e de d fo r e a c h Q C p r o c e s s .

QC Process QC Ma teria l Used

V erify fluid ics and las er alig nment

Flow -Ch eck™ Fluoros p h eres (Flow -Ch eck 67 5 Fluoros p h eres , Flow -Ch eck 7 7 0 Fluoros p h eres ). V erify H PCV vers us exp ected value. E xp ort res ults to th e Q C D atab as e and review th e Q C d ata.

Ad jus t h ig h voltag e and g ain for a g iven ap p lication

Flow -S et™ Fluoros p h eres (Flow -S et 67 5 Fluoros p h eres , Flow -S et 7 7 0 Fluoros p h eres ). As certain targ et mean p os ition b as ed up on ap p lication and ad jus t h ig h voltag e and g ain d aily to th at targ et. E xp ort res ults to th e Q C D atab as e and review th e Q C d ata.

M onitor ins trument linearity

Immuno-Brite™ Fluoros p h eres .

Perform ab s olute counts Flow -Count™ Fluoros p h eres .

Ad jus t color comp ens ation for a g iven ap p lication

For AutoS etup ap p lications , Cy to-Comp ™ Cells or w h ole b lood s tained w ith Q uickCO M P™ 2 or Q uickCO M P 4 kit. U s e s ing le color s tained s amp les w ith each fluoroch rome us ed in y our ap p lication. For examp le: CD 45-FIT C, CD 45-PE , CD 45-E CD , CD 45-PC5 or CD 45-PC7 .

V erify correct s etting s w ith an ap p lication Control

U p d ate th e control p rotocol w ith th e s etting s d erived from ab ove. R un a b iolog ical control eq uivalent to th e ap p lication, s uch as Immuno-T rol™ Cells , Immuno-T rol L ow Cells , Cy to-trol™ Control Cells , S tem-T rol™ Control Cells , or a normal w h ole b lood . E xp ort res ults to th e Q C D atab as e and review th e Q C d ata.

Page 72: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-2

QUALITY CONTROLD A IL Y Q C

3.3 DAILY QCD a ily Q C c o ns is ts o f:

r P r e p a r ing A u to S e tu p S a m p le s

r R u nning th e A u to S e tu p S c h e du le r

r R u nning th e A u to S e tu p I I W iz a rd

Prep a ring AutoSetup Sa m p les

IMPORTANT R is k of erroneous res ults if th e Cy tometer h as b een id le for an extend ed p eriod of time or y ou h ave jus t p erformed D aily S tartup . T o ens ure correct res ults , p erform a p rime after:

r D aily S tartup .

r T h e Cy tometer h as b een id le for an extend ed p eriod of time.

r Y ou p lace a new carous el on th e M CL and lig h t s catter s ig nals ap p ear ab normal.

1 P r e p a r e th e a p p r o p r ia te F lo w -Ch e c k flu o r o s p h e r e s fo r th e a p p lic a tio ns y o u ne e d to r u n.

T h e flu o r o s p h e r e s y o u u s e to p e r fo r m a lig nm e nt v e r ific a tio n de p e nd u p o n w h ic h a p p lic a tio n y o u a r e u s ing , a s s h o w n in th e c h a r t b e lo w . F o llo w th e p a c k a g e ins e r t ins tr u c tio ns fo r m ix ing a nd h a ndling flu o r o s p h e r e s .

Ap p lica tion Flow -Ch eck Flow -Ch eck 770 Flow -Ch eck 675

FS -S S -FIT C-PE -E CD -PC5 c

FS -S S -FIT C-PE -E CD -PC5-PC7 c c

FS -S S -FIT C-PE -E CD -APC c c

FS -S S -FIT C-PE -E CD -APC-PC7 c c c

Page 73: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-3

QUALITY CONTROLD A IL Y Q C 3

2 P r e p a r e th e a p p r o p r ia te F lo w -S e t flu o r o s p h e r e s fo r th e a p p lic a tio ns y o u ne e d to r u n. T h e

F lo w - S e t flu o r o s p h e r e s tu b e is u s e d to s e t th e de te c to r g a ins a nd v o lta g e s to th e r e q u ir e d le v e l. T h e flu o r o s p h e r e s y o u u s e to p e r fo r m s ta nda rdiz a tio n de p e nd u p o n w h ic h a p p lic a tio n y o u a r e u s ing , a s s h o w n in th e c h a r t b e lo w . F o llo w th e p a c k a g e ins e r t ins tr u c tio ns fo r m ix ing a nd h a ndling th e s e flu o r o s p h e r e s .

3 P r e p a r e A u to S e tu p c o m p e ns a tio n tu b e s

fo r e a c h flu o r o c h r o m e in th e a p p lic a tio n y o u ne e d to r u n.

S ta in w ith a p p r o p r ia te s ing le c o lo r r e a g e nts , s u c h a s CD 45, in e a c h flu o r o c h r o m e .

4 P r e p a r e a n A u to S e tu p v e r ific a tio n tu b e .

a . U s e th e a p p r o p r ia te a m o u nt o f Im m u no -T r o l Ce lls o r I m m u no -T r o l Lo w Ce lls a c c o rding to th e ins tr u c tio ns o n th e p a c k a g e ins e r t o r r e c o ns titu te th e Cy to -tr o l Co ntr o l Ce lls a c c o rding to th e ins tr u c tio ns o n th e p a c k a g e ins e r t.

b . S ta in th e c e lls w ith th e m o no c lo na l a ntib o die s y o u u s e fo r th e p r o to c o l o r p a ne l.

5 R u n th e A u to S e tu p S c h e du le r.

Ap p lica tion Flow -Set Flow -Set 770 Flow -Set 675

FS -S S -FIT C-PE -E CD -PC5 c

FS -S S -FIT C-PE -E CD -PC5-PC7 c c

FS -S S -FIT C-PE -E CD -APC c c

FS -S S -FIT C-PE -E CD -APC-PC7 c c c

Page 74: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-4

QUALITY CONTROLA U TOSETU P SCH ED U L ER

3.4 AUTOSETUP SCHEDULERU s e th e A u to S e tu p S c h e du le r to s e le c t th e a p p lic a tio ns th a t y o u ne e d to r u n o n th e ins tr u m e nt in a g iv e n da y o r " s h ift" . A u to S e tu p S c h e du le r g r o u p s th e s e le c te d a p p lic a tio ns a nd p r o v ide s th e c a r o u s e l lo a d r e p o r t to fa c ilita te s e tting u p a nd lo a ding s a m p le s fo r da ily Q C.

1 Tools tt AutoSetup Sch ed uler.

2 th e a p p lic a tio ns y o u w a nt to

s c h e du le fo r a g iv e n da y o r s h ift.

If y o u w a nt to s c h e du le a n a p p lic a tio n th a t do e s no t a p p e a r in th e lis t, u s e th e A p p lic a tio n D e finitio n W iz a rd to de fine th e a p p lic a tio n.

N ote: U s ing th e de s c r ip to r Q C in fr o nt o f a ny p r o to c o l na m e a p p e nds th e r e s u lts o f m u ltip le F lo w -Ch e c k r u ns to a s ing le s p r e a ds h e e t. S e e W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns to a u to m a tic a lly e x p o r t da ta to MS E x c e l fo r Q u a lity Co ntr o l m o nito r ing o r b a s ic s p r e a ds h e e t da ta e ntr y .

3 E nte r th e Ca r o u s e l nu m b e r a nd .

Page 75: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-5

QUALITY CONTROLA U TOSETU P II W IZ A R D 3

3.5 AUTOSETUP II WIZ ARDA u to S e tu p I I s im p lifie s a nd a u to m a te s a p p lic a tio n s e tu p a nd Q C m o nito r ing fo r m u ltip le a p p lic a tio ns s im u lta ne o u s ly . Y o u c a n p e r fo r m a Q C s e tu p fo r a ll o f y o u r m u ltic o lo r a p p lic a tio ns th a t y o u r u n du r ing a s ing le da y o r s h ift a t th e s a m e tim e fo r c o m m o n ins tr u m e nt o p tic a l c o nfig u r a tio ns u s ing th e A p p lic a tio n D e finitio n W iz a rd a nd th e A u to S e tu p S c h e du le r.

Before Running th e AutoSetup II Wiz a rd

r Ch e c k th a t th e D A ILY S T A R T U P p r o c e du r e w a s p e r fo r m e d.

r A llo w a b o u t 40 m inu te s to w a r m u p th e s y s te m .

r Ch e c k th e Cy to m e te r s ta tu s m e s s a g e . S ta r t th is p r o c e du r e w h e n th e Cy to m e te r s ta tu s m e s s a g e A waiting S ample a p p e a r s . R e c o rd a ny e r r o r m e s s a g e s in y o u r ins tr u m e nt’s lo g b o o k .

r S e t u p W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns to p r int r e s u lts .

r S e t u p W o r k s p a c e P r e fe r e nc e s - LMD F ile N a m e to s p e c ify lis tm o de file na m e s .

4 to p r int th e Ca r o u s e l

Lo a d R e p o r t.

N ote: I f a b s o lu te c o u nts a r e r e q u ir e d,

a nd u s e th e A c q u is itio n Ma na g e r to e nte r th e CA L F a c to r.

5 P la c e tu b e s in th e c a r o u s e l in th e o rde r

s h o w n o n th e Ca r o u s e l Lo a d R e p o r t.

o n th e Ca r o u s e l Lo a d R e p o r t s c r e e n to r u n A u to S e tu p II .

IMPORTANT R is k of erroneous res ults if th e Cy tometer h as b een id le for an extend ed p eriod of time or y ou h ave jus t p erformed D aily S tartup . T o ens ure correct res ults , p erform a p rime after:

r D aily S tartup .

r T h e Cy tometer h as b een id le for an extend ed p eriod of time.

r Y ou p lace a new carous el on th e M CL and lig h t s catter s ig nals ap p ear ab normal.

Page 76: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-6

QUALITY CONTROLA U TOSETU P II W IZ A R D

r F o llo w th e dir e c tio ns in th e F lo w -Ch e c k flu o r o s p h e r e s p a c k a g e ins e r t to e s ta b lis h e x p e c te d r a ng e v a lu e s fo r y o u r la b o r a to r y .

r E s ta b lis h F lo w - S e t flu o r o s p h e r e s ta r g e t c h a nne ls fo r y o u r la b o r a to r y a nd m o dify th e de fa u lt a p p lic a tio n de finitio ns if ne c e s s a r y . F o llo w th e dir e c tio ns in th e F lo w - S e t flu o r o s p h e r e s p a c k a g e ins e r t.

r S e t u p th e Q C P r o du c ts th a t y o u ne e d to u s e w ith A u to S e tu p a p p lic a tio ns .

r S e t u p r e g io n s ta tis tic s e x p o r ting a nd a s s ig n Q C p r o du c ts to r e g io ns .

r If a c q u is itio n e nds a s a r e s u lt o f du r a tio n (no t s to p c o u nt) w h ile r u nning A u to S e tu p II ,

s e le c t o n th e Cy to m e te r Co ntr o l to o lb a r to c o ntinu e .

r B e fo r e u s ing a ne g a tiv e c o ntr o l s a m p le w ith A u to S e tu p , y o u m u s t Mo dify A S ta nda rdiz a tio n P r o to c o l fo r u s e in th e A u to S e tu p p a ne l. S e e U s ing N e g a tiv e Co ntr o ls w ith A u to S e tu p in th e R e fe r e nc e Ma nu a l.

1 o n th e Ca r o u s e l Lo a d

R e p o r t s c r e e n in th e A u to S e tu p S c h e du le r.

2 A fte r da ta a c q u is itio n s ta r ts v ie w a ll

h is to g r a m s to e ns u r e p e a k s fa ll w ith in r e g io ns .

a . S e tu p Mo de o n th e Cy to m e te r Co ntr o l A c q u is itio n S e tu p T a b .

b . A dju s t v o lta g e s to p la c e p e a k s w ith in r e g io ns

c . U nc h e c k S e tu p Mo de .

Page 77: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-7

QUALITY CONTROLA U TOSETU P II W IZ A R D 3

N ote: W h e n r u nning a ne g a tiv e c o ntr o l v e r ify th a t th e A u to G a te is a r o u nd th e p o p u la tio n o f inte r e s t in th e F S v s S S do tp lo t. If y o u ne e d to , a dju s t p o p u la tio ns .

a . Auto Ad just Disa b led a s s o o n a s th e A u to S e tu p w iz a rd dis p la y s .

b . a dju s t v o lta g e s to p la c e th e ly m p h o c y te s in a s u ita b le p o s itio n.

c . a dju s t v o lta g e s to p la c e th e flu o r e s c e nc e p o p u la tio ns w ith in th e fir s t lo g de c a de .

d. .

T h e W iz a rd a dju s ts V o lts a nd G a ins to p la c e th e F lo w -S e t flu o r o s p h e r e s w ith in th e r e g io ns . T h e W iz a rd dia lo g b o x dis p la y s a lis t o f th e p a r a m e te r s r e m a ining to b e a dju s te d. If th e W iz a rd c a nno t a dju s t p e a k s to th e r e g io ns w ith in 60 s e c o nds , A u to S e tu p a b o r ts a nd th e p a r a m e te r s th a t fa ile d a r e lis te d.

T h e c o m p e ns a tio n tu b e s a r e u s e d to c a lc u la te th e c o m p e ns a tio n c o e ffic ie nts r e q u ir e d, a ll th e s e tu b e s a r e r u n in th e s a m e w a y .

Page 78: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-8

QUALITY CONTROLA U TOSETU P II W IZ A R D

T h is p r o c e s s is r e p e a te d fo r e a c h o f th e c o m p e ns a tio n tu b e s ( fo r e x a m p le : F L2, F L3, F L4, a nd F L5) .

V e r ific a tio n s a m p le s a r e r u n to e ns u r e th e c a lc u la te d c o e ffic ie nts a r e s a tis fa c to r y fo r th e s a m p le s a nd a ntib o die s y o u a r e u s ing in y o u r te s ts .

N ote: I f m u ltip le a p p lic a tio ns a r e s c h e du le d to g e th e r, s a m p le s c o m m o n to th e a p p lic a tio ns a r e p r o c e s s e d in ta nde m w ith o u t dr o p p ing th e tu b e . T h e p r o to c o l is dis p la y e d du r ing p r o c e s s ing .

3 to p r int v e r ific a tio n

tu b e r e s u lts a nd a dv a nc e to th e a p p r o v e s c r e e n.

Page 79: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-9

QUALITY CONTROLA U TOSETU P II W IZ A R D 3

4 Ch e c k th e p r inte d v e r ific a tio n tu b e

r e s u lts to e ns u r e ins tr u m e nt s e tting s

a r e c o r r e c t a nd .

N ote: D u e to diffe r e nc e s b e tw e e n indiv idu a l ins tr u m e nts , s e tting s file s s h o u ld no t b e tr a ns fe r r e d fr o m o ne ins tr u m e nt to a no th e r. I f y o u a tte m p t to u s e s e tting s file s fr o m a no th e r ins tr u m e nt, th e s o ftw a r e dis p la y s Incorrect C y tometer S erial N umber.

5 R e v ie w Q C R e s u lts in th e Q C D a ta b a s e .

Page 80: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-1 0

QUALITY CONTROLA P P L ICA TION D EF INITION W IZ A R D

3.6 APPLICATION DEFINITION WIZ ARDU s e th e A p p lic a tio n D e finitio n W iz a rd to de fine y o u r a p p lic a tio ns a nd s a v e th e de finitio ns fo r u s e b y th e A u to S e tu p S c h e du le r. T h e a p p lic a tio n de finitio n c a p tu r e s th e ins tr u m e nt s e tu p , la s e r s , p a r a m e te r s , flu o r o c h r o m e s , ta r g e t c h a nne ls , v e r ific a tio n a nd a lig nm e nt r e q u ir e m e nts o f a p a r tic u la r a p p lic a tio n.

Before Running th e Ap p lica tion Definition Wiz a rd

r E s ta b lis h F lo w - S e t flu o r o s p h e r e s ta r g e t c h a nne ls fo r y o u r la b o r a to r y . F o llo w th e dir e c tio ns in th e F lo w -S e t flu o r o s p h e r e s p a c k a g e ins e r t.

r E ns u r e th a t th e b a s e p r o to c o l y o u u s e to de fine a n a p p lic a tio n c o nta ins o nly th e p a r a m e te r s th a t y o u u s e in th e a p p lic a tio n. If it c o nta ins e x tr a u nu s e d p a r a m e te r s , th e c o m p e ns a tio n m a tr ix w ill b e inc o r r e c t.

1 Tools tt AutoSetup Ap p lica tion

Definition.

2 o ne o f th e fo llo w ing o p tio ns :

Ap p lica tion a v a ila b le only to current userAp p lica tion a v a ila b le to a ll users (com m on).

3 o ne o f th e fo llo w ing o p tio ns :

Crea te a new a p p lica tion d efinitionMod ify a n a p p lica tion d efinition

a nd th e n .

Page 81: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-1 1

QUALITY CONTROLA P P L ICA TION D EF INITION W IZ A R D 3

4 a nd s e le c t th e p r o to c o l

to u s e a s th e b a s e p r o to c o l fo r th e a p p lic a tio n.

T h e P r o to c o l S u m m a r y dis p la y s a de s c r ip tio n o f th e p a r a m e te r s a nd la s e r s e tu p fo r th e s e le c te d p r o to c o l.

.

5 th e filte r b lo c k to u s e fo r th e

a p p lic a tio n a nd .

N ote: A n a lig nm e nt a p p lic a tio n m a y no t h a v e a U s e r de fine d F ilte r B lo c k s e le c te d. A lig nm e nt a p p lic a tio ns m u s t h a v e e ith e r a 1-La s e r F ilte r B lo c k o r 2-La s e r F ilte r B lo c k s e le c te d.

6 th e fo r w a rd s c a tte r c o lle c tio n

a ng le to u s e fo r th e a p p lic a tio n a nd

.

Page 82: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-1 2

QUALITY CONTROLA P P L ICA TION D EF INITION W IZ A R D

7 th e dy e s y o u u s e fo r e a c h

flu o r e s c e nc e de te c to r a nd

.

8 S e le c t a Q C p r o du c t a nd e nte r a ta r g e t

c h a nne l fo r F o r w a rd S c a tte r, S ide S c a tte r a nd e a c h flu o r e s c e nc e de te c to r.

N ote: I f y o u a r e r u nning a 5 c o lo r 2 la s e r a p p lic a tio n, e nte r F lu o r e s c e nc e a nd F o r w a rd S c a tte r ta r g e t c h a nne ls fo r th e F lo w -S e t 67 5 a nd F lo w - S e t 7 7 0 F lu o r o s p h e r e s .

Page 83: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-1 3

QUALITY CONTROLA P P L ICA TION D EF INITION W IZ A R D 3

9 E nte r na m e s fo r th e a p p lic a tio n a nd th e

ins tr u m e nt s e tting s file a nd

.

10 Ch o o s e to h a v e th e w iz a rd c r e a te a

v e r ific a tio n p r o to c o l o r a dd a s a v e d v e r ific a tio n p r o to c o l o r p a ne l. U s e th e b u tto ns to a dd, r e m o v e a nd r e o rde r m u ltip le v e r ific a tio n p r o to c o ls .

.

N ote: A ny p a ne ls u s e d fo r Q u a lity

Co ntr o l m u s t b e c o ns tr u c te d w ith u niq u e indiv idu a l p r o to c o ls .

11 A s u m m a r y r e p o r t is dis p la y e d fo r th e

a p p lic a tio n y o u ju s t de fine d. T h e a p p lic a tio n de finitio n is a v a ila b le fo r u s e w ith th e A u to S e tu p S c h e du le r.

to p r int th e s u m m a r y

r e p o r t a nd to e x it th e w iz a rd.

Page 84: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-1 4

QUALITY CONTROLA P P L ICA TION D EF INITION W IZ A R D

Setting Up QC Prod ucts

Ex p orting Reg ion Results To QC Da ta b a se a nd Assig ning QC Prod ucts

1 to dis p la y

th e R e p o r t G e ne r a to r to o lb a r.

2 o n th e R e p o r t G e ne r a to r

to o lb a r to dis p la y th e E dit P r o du c ts s c r e e n.

3 R e fe r to th e p a c k a g e ins e r t a nd e nte r

info r m a tio n a b o u t th e Q C P r o du c t in th e a p p r o p r ia te fie lds .

4 .

1 o n a r e g io n to m a k e it a c tiv e .

2 R ig h t m o u s e c lic k o n th e r e g io n a nd

Reg ion Prop erties.

Page 85: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 3-1 5

QUALITY CONTROLA P P L ICA TION D EF INITION W IZ A R D 3

Rev iew QC Results

3 E ns u r e th a t Reg ion Sta tistics ex p orted

for Qua lity Control.

4 ne x t to QC Prod uct a nd s e le c t

th e Q C P r o du c t to a s s ig n to th e r e g io n.

5 a nd s a v e th e p r o to c o l.

1 to dis p la y

th e R e p o r t G e ne r a to r to o lb a r.

2 o n th e R e p o r t G e ne r a to r

to o lb a r to dis p la y th e Q C Le v e y Je nning s s c r e e n.

Page 86: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B3-1 6

QUALITY CONTROLA P P L ICA TION D EF INITION W IZ A R D

3 ne x t to Ap p lica tion

a nd to s e le c t a n a p p lic a tio n.

4 Tem p la te tt Op en Tem p la te.

5 th e de s ir e d te m p la te a nd

.

6 R e p e a t s te p s 3 - 5 to v ie w o th e r Q C da ta p lo ts .

S e e Q C Le v e y Je nning s S c r e e n in th e R e fe r e nc e m a nu a l fo r info r m a tio n a b o u t c r e a ting a nd e diting Q C p lo ts .

Page 87: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 4-1

44RUNNING SAMPLES

4.1 SAMPLE REQUIREMENTSA t le a s t 0 .5 m L o f p r e p a r e d s a m p le is ne e de d. I t m u s t b e in a 12- x 7 5-m m te s t tu b e . S a m p le s a na ly z e d o n th e ins tr u m e nt m u s t b e in a s ing le -c e ll s u s p e ns io n. T y p ic a lly , c e lls a r e p r e p a r e d b e fo r e th e y a r e a na ly z e d. T h e m e th o d u s e d to p r e p a r e a s p e c im e n de p e nds o n th e s a m p le ty p e a nd th e a s s a y de s ir e d. F o r e x a m p le , a T Q -P r e p w o r k s ta tio n c o m b ine d w ith a P r e p P lu s o r P r e p P lu s 2 le ts y o u p r e p a r e a ntib o dy -la b e le d c e lls fr o m a n a ntic o a g u la te d w h o le - b lo o d s p e c im e n fo r s u r fa c e m a r k e r a na ly s is .

In g e ne r a l, th e o p tim u m c o nc e ntr a tio n fo r a na ly s is is 5 x 10 6 c e lls /m L. W h e n th is c o nc e ntr a tio n is no t p o s s ib le , r e fe r to th e p a c k a g e ins e r t fo r th e p r e p a r a tio n m e th o d y o u a r e u s ing .

T h e ins tr u m e nt c a n m e a s u r e c e lls th a t a r e b e tw e e n 0 .5 µ m a nd 40 µ m in dia m e te r.

4.2 BEFORE RUNNING SAMPLES

1 Ch e c k th a t th e D A ILY S T A R T U P p r o c e du r e s w e r e do ne .

2 Ch e c k th a t th e D A ILY Q C p r o c e du r e s w e r e do ne .

3 E ns u r e A c q u is itio n O p tio ns a nd LMD file na m e a r e s e t u p in W o r k s p a c e P r e fe r e nc e s .

4 E ns u r e th e r e is s u ffic ie nt s p a c e o n y o u r h a rd dr iv e fo r s a m p le p r o c e s s ing a nd da ta

a c q u is itio n.

5 R e a d th e I m p o r ta nt Info r m a tio n o n th e S u p p o r t ta b in th e R e s o u rc e E x p lo r e r .

IMPORTANT R is k of erroneous res ults if th e Cy tometer h as b een id le for an extend ed p eriod of time or y ou h ave jus t p erformed D aily S tartup . T o ens ure correct res ults , p erform a p rime after:

r D aily S tartup .

r T h e Cy tometer h as b een id le for an extend ed p eriod of time.

r Y ou p lace a new carous el on th e M CL and lig h t s catter s ig nals ap p ear ab normal.

Page 88: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B4-2

RUNNING SAMPLESR U NNING SA M P L ES - M CL A U TOM A TIC M OD E

4.3 RUNNING SAMPLES - MCL AUTOMATIC MODESHOW ME a n e x a m p le o f MCL A u to m a tic Mo de s a m p le p r o c e s s ing .

IMPORTANT R is k of s amp le mis id entification if a p ow er failure occurs d uring s amp le p roces s ing . In th e event of a p ow er failure, d is card any in-p roces s s amp les .

1 P r e p a r e s a m p le s a c c o rding to th e

r e a g e nt p a c k a g e ins e r t.

2 P la c e th e s a m p le tu b e s in a c a r o u s e l.

CAUTION Pos s ib le flow cell d amag e. T o avoid clog g ing th e s amp le p rob e, s amp le tub ing or flow cell, ens ure th at 1 2 mm x 7 5 mm tes t tub es are free of d eb ris b efore y ou us e th em.

Page 89: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 4-3

RUNNING SAMPLESR U NNING SA M P L ES - M CL A U TOM A TIC M OD E 4

3 O p e n th e MCL c o v e r a nd p la c e th e

c a r o u s e l o n th e MCL.

4 Clo s e th e MCL c o v e r.

WARNING R is k of injury . D o not op en th e M CL cover w h ile th e M CL is moving . T o avoid injury , w ait until th e M CL s top s moving b efore op ening th e M CL cover.

Page 90: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B4-4

RUNNING SAMPLESR U NNING SA M P L ES - M CL A U TOM A TIC M OD E

5 U s e th e A c q u is itio n Ma na g e r T o o lb a r

o r D r a g A nd D r o p to s e le c t th e W o r k lis t, P a ne l o r P r o to c o l y o u w a nt to u s e .

N ote: I f y o u lo a d a P a ne l th a t c o nta ins a de le te d P r o to c o l, th e s o ftw a r e p r o m p ts y o u to u s e th e N e w P a ne l W iz a rd to c o r r e c t th e p r o b le m .

6 E nte r th e c a r o u s e l ID nu m b e r in th e

A c q u is itio n Ma na g e r.

7 to b e g in p r o c e s s ing s a m p le s .

D u r ing th e s a m p le c y c le th e fo llo w ing s e r ie s o f Cy to m e te r s ta tu s m e s s a g e s a p p e a r s :

A waiting S ample

P reparing S ample

A cquiring

S topping.

8 O b s e r v e th e E v e nts /S e c c o u nte r o n th e S ta tu s B a r to m o nito r da ta a c q u is itio n.

N ote: W h ile r u nning a W o r k lis t a nd u s ing b a r c o de s o n y o u r s a m p le tu b e s , if th e T u b e ID in th e W o r k lis t do e s no t m a tc h th e b a r c o de o n th e tu b e , a s y s te m m e s s a g e a p p e a r s . A fte r y o u a c k no w le dg e th e m e s s a g e , th e m is m a tc h e d tu b e is a b o r te d a nd th e p r o c e s s ing s to p s fo r th e r e s t o f th e c a r o u s e l.

IMPORTANT R is k of erroneous res ults if th e s amp le b ecomes d iluted . W h en op erating th e Cy tometer, if th e M CL cover is op ened , an aud ib le alarm s ound s and a w arning mes s ag e is d is p lay ed . If acq uis ition comp letes w h ile th e M CL cover is op ened , d o not us e th e s amp le for s ub s eq uent p roces s ing . U nd er th is cond ition, th e current s amp le may b e d iluted at th e end of acq uis ition.

Page 91: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 4-5

RUNNING SAMPLESR U NNING SA M P L ES - M CL M A NU A L M OD E 4

4.4 RUNNING SAMPLES - MCL MANUAL MODEMCL Ma nu a l Mo de o p e r a te s th e s a m e a s MCL A u to m a tic Mo de e x c e p t th e MCL s to p s a fte r p r o c e s s ing e a c h tu b e to a llo w y o u to e dit th e S a m p le ID .

.

9 V e r ify a ll s a m p le ID s b e fo r e r e p o r ting r e s u lts .

10 P r int P a tie nt P a ne l R e p o r t, if ne e de d. S e e P a ne l R e p o r t in th e R e fe r e nc e m a nu a l.

IMPORTANT R is k of rep orting incorrect res ults . D ata d is p lay s for lig h t s catter p atterns , antib od y s taining p rofiles , and all g ates and b ound aries us ed to arrive at th e tes t res ult s h ould b e review ed b y a lab oratory p rofes s ional w h en interp reting th e d ata.

1 P r e p a r e s a m p le s a c c o rding to th e

r e a g e nt p a c k a g e ins e r t.

2 P la c e th e s a m p le tu b e s in a c a r o u s e l.

CAUTION Pos s ib le flow cell d amag e. T o avoid clog g ing th e s amp le p rob e, s amp le tub ing or flow cell, ens ure th at 1 2 mm x 7 5 mm tes t tub es are free of d eb ris b efore y ou us e th em.

Page 92: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B4-6

RUNNING SAMPLESR U NNING SA M P L ES - M CL M A NU A L M OD E

3 O p e n th e MCL c o v e r a nd p la c e th e

c a r o u s e l o n th e MCL.

4 Clo s e th e MCL c o v e r.

5 T o s to p a fte r p r o c e s s ing e a c h tu b e a nd

e dit th e S a m p le ID ,

Ed it Sa m p le IDs o n W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns .

WARNING R is k of injury . D o not op en th e M CL cover w h ile th e M CL is moving . T o avoid injury , w ait until th e M CL s top s moving b efore op ening th e M CL cover.

Page 93: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 4-7

RUNNING SAMPLESR U NNING SA M P L ES - M CL M A NU A L M OD E 4

6 U s e th e A c q u is itio n Ma na g e r T o o lb a r

o r D r a g A nd D r o p to s e le c t th e W o r k lis t, P a ne l o r P r o to c o l y o u w a nt to u s e .

N ote: I f y o u lo a d a P a ne l th a t c o nta ins a de le te d P r o to c o l, th e s o ftw a r e p r o m p ts y o u to u s e th e N e w P a ne l W iz a rd to c o r r e c t th e p r o b le m .

7 E nte r th e c a r o u s e l ID nu m b e r in th e

A c q u is itio n Ma na g e r.

8 to p la c e th e Cy to m e te r in MCL Ma nu a l Mo de .

9 to b e g in p r o c e s s ing s a m p le s .

IMPORTANT R is k of erroneous res ults if th e s amp le b ecomes d iluted . W h en op erating th e Cy tometer, if th e M CL cover is op ened , an aud ib le alarm s ound s and a w arning mes s ag e is d is p lay ed . If acq uis ition comp letes w h ile th e M CL cover is op ened , d o not us e th e s amp le for s ub s eq uent p roces s ing . U nd er th is cond ition, th e current s amp le may b e d iluted at th e end of acq uis ition.

Page 94: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B4-8

RUNNING SAMPLESR U NNING SA M P L ES - M CL M A NU A L M OD E

10 E nte r th e tu b e lo c a tio n to p r o c e s s a nd

.

D u r ing th e s a m p le c y c le th e fo llo w ing s e r ie s o f Cy to m e te r s ta tu s m e s s a g e s a p p e a r s :

A waiting S ample

P reparing S ample

A cquiring

S topping.

11 O b s e r v e th e E v e nts /S e c c o u nte r o n th e S ta tu s B a r to m o nito r da ta a c q u is itio n.

N ote: W h ile r u nning a W o r k lis t, if th e T u b e I D in th e W o r k lis t do e s no t m a tc h th e b a r c o de o n th e tu b e , a s y s te m m e s s a g e a p p e a r s . A fte r y o u a c k no w le dg e th e m e s s a g e , th e m is m a tc h e d tu b e is a b o r te d a nd th e p r o c e s s ing s to p s fo r th e r e s t o f th e c a r o u s e l.

12 If y o u e na b le d Ed it Sa m p le IDs o n

W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns , e dit th e s a m p le I D a fte r th e tu b e finis h e s p r o c e s s ing a nd

.

N ote: A fte r th e fir s t tu b e in a p a ne l, S a m p le ID 1 c a nno t b e c h a ng e d.

13 E nte r th e lo c a tio n o f th e ne x t tu b e to

p r o c e s s a nd .

14 R e p e a t s te p s 12 a nd 13 to p r o c e s s a dditio na l tu b e s .

Page 95: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 4-9

RUNNING SAMPLESR U NNING SA M P L ES - SING L E TU B E M OD E 4

4.5 RUNNING SAMPLES - SINGLE TUBE MODET h e S ing le T u b e Mo de o p e r a te s b y intr o du c ing tu b e s indiv idu a lly into th e MCL th r o u g h th e MCL T u b e A c c e s s do o r. SHOW ME a n e x a m p le o f S ing le T u b e Mo de s a m p le p r o c e s s ing .

N ote: W h e n o p e r a ting in th e S ing le T u b e Mo de , th e P r im e fu nc tio n is no t a v a ila b le w h e n th e s y s te m is b e tw e e n s a m p le s , e v e n th o u g h th e to o lb a r is a c tiv e .

.

15 V e r ify a ll s a m p le ID s b e fo r e r e p o r ting r e s u lts .

16 P r int P a tie nt P a ne l R e p o r t, if ne e de d. S e e P a ne l R e p o r t in th e R e fe r e nc e m a nu a l.

IMPORTANT R is k of rep orting incorrect res ults . D ata d is p lay s for lig h t s catter p atterns , antib od y s taining p rofiles , and all g ates and b ound aries us ed to arrive at th e tes t res ult s h ould b e review ed b y a lab oratory p rofes s ional w h en interp reting th e d ata.

1 P r e p a r e s a m p le s a c c o rding to th e

r e a g e nt p a c k a g e ins e r t.

2 If y o u w a nt th e MCL to s to p a fte r

p r o c e s s ing e a c h tu b e to a llo w y o u to

e dit th e S a m p le ID , Ed it

Sa m p le IDs o n W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns .

CAUTION Pos s ib le flow cell d amag e. T o avoid clog g ing th e s amp le p rob e, s amp le tub ing or flow cell, ens ure th at 1 2 mm x 7 5 mm tes t tub es are free of d eb ris b efore y ou us e th em.

Page 96: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B4-1 0

RUNNING SAMPLESR U NNING SA M P L ES - SING L E TU B E M OD E

3 U s e th e A c q u is itio n Ma na g e r T o o lb a r

o r D r a g A nd D r o p to s e le c t th e W o r k lis t, P a ne l o r P r o to c o l y o u w a nt to u s e .

N ote: I f y o u lo a d a P a ne l th a t c o nta ins a de le te d P r o to c o l, th e s o ftw a r e p r o m p ts y o u to u s e th e N e w P a ne l W iz a rd to c o r r e c t th e p r o b le m .

4 to p la c e th e Cy to m e te r in S ing le T u b e Mo de . T h e MCL m o v e s to p u t c a r o u s e l

p o s itio n 10 u nde r th e T u b e A c c e s s do o r.

5 O p e n th e MCL T u b e A c c e s s do o r a nd

p la c e th e s a m p le tu b e in c a r o u s e l p o s itio n 10 .

WARNING R is k of injury . D o not op en th e M CL cover w h ile th e M CL is moving . T o avoid injury , w ait until th e M CL s top s moving b efore op ening th e M CL cover.

IMPORTANT R is k of erroneous res ults if th e s amp le b ecomes d iluted . W h en op erating th e Cy tometer, if th e M CL cover is op ened , an aud ib le alarm s ound s and a w arning mes s ag e is d is p lay ed . If acq uis ition comp letes w h ile th e M CL cover is op ened , d o not us e th e s amp le for s ub s eq uent p roces s ing . U nd er th is cond ition, th e current s amp le may b e d iluted at th e end of acq uis ition.

Page 97: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 4-1 1

RUNNING SAMPLESR U NNING SA M P L ES - SING L E TU B E M OD E 4

6 Clo s e th e MCL T u b e A c c e s s do o r a nd

to b e g in p r o c e s s ing s a m p le s .

D u r ing th e s a m p le c y c le th e fo llo w ing s e r ie s o f Cy to m e te r s ta tu s m e s s a g e s a p p e a r s :

A waiting S ample

P reparing S ample

A cquiring

S topping.

7 O b s e r v e th e E v e nts /S e c c o u nte r o n th e S ta tu s B a r to m o nito r da ta a c q u is itio n.

N ote: W h ile r u nning a W o r k lis t, if th e T u b e I D in th e W o r k lis t do e s no t m a tc h th e b a r c o de o n th e tu b e , a s y s te m m e s s a g e a p p e a r s . A fte r y o u a c k no w le dg e th e m e s s a g e , th e m is m a tc h e d tu b e is a b o r te d a nd th e p r o c e s s ing s to p s fo r th e r e s t o f th e c a r o u s e l.

8 V e r ify a ll s a m p le ID s b e fo r e r e p o r ting r e s u lts .

9 If y o u e na b le d Ed it Sa m p le IDs o n

W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns , e dit th e s a m p le ID a nd

.

N ote: A fte r th e fir s t tu b e in a p a ne l, S a m p le ID 1 c a nno t b e c h a ng e d.

IMPORTANT R is k of rep orting incorrect res ults . D ata d is p lay s for lig h t s catter p atterns , antib od y s taining p rofiles , and all g ates and b ound aries us ed to arrive at th e tes t res ult s h ould b e review ed b y a lab oratory p rofes s ional w h en interp reting th e d ata.

Page 98: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B4-1 2

RUNNING SAMPLESR U NNING SA M P L ES - SING L E TU B E M OD E

10 R e p e a t s te p s 5 th r o u g h 9 to p r o c e s s a dditio na l tu b e s .

to e x it S ing le T u b e Mo de a nd r e tu rn to A u to m a tic Mo de .

11 P r int P a tie nt P a ne l R e p o r t, if ne e de d. S e e P a ne l R e p o r t in th e R e fe r e nc e m a nu a l.

Page 99: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-1

55OPERATION PRINCIPLES

5.1 WHAT THIS CHAPTER EX PLAINST h is c h a p te r e x p la ins h o w th e Cy to m e te r m e a s u r e s s c a tte r e d lig h t a nd flu o r e s c e nc e a s c e lls p a s s th r o u g h th e la s e r b e a m .

T h e illu s tr a tio ns in th is c h a p te r a r e no t e x a c t r e p r e s e nta tio ns o f th e ins ide o f th e Cy to m e te r. T h e y a r e fo r e x p la na to r y p u r p o s e s o nly .

5.2 SAMPLE FLOW

Sa m p le Loa d ing

T h e s a m p le c a r o u s e l h a s b a r- c o de la b e ls th a t ide ntify th e c a r o u s e l a nd th e tu b e p o s itio n nu m b e r. A ls o , y o u c a n p u t b a r-c o de la b e ls o n th e s a m p le tu b e s . S e e A p p e ndix B , B A R -CO D E S P E CIF ICA T IO N S .

T h e MCL h a s a b a r- c o de r e a de r th a t r e a ds th e c a r o u s e l nu m b e r, th e s a m p le tu b e p o s itio n, a nd th e s a m p le tu b e b a r-c o de la b e ls a s th e c a r o u s e l r o ta te s . T h e MCL h a ndle s a s a m p le tu b e a s fo llo w s :

r It lifts th e tu b e o u t o f th e c a r o u s e l into a c e nte r ing c u p .

r It m o v e s th e b o tto m o f th e tu b e in a c irc u la r o r b it fo r 3 s e c o nds to m ix th e s a m p le .

r It lo w e r s its s a m p le p r o b e into th e tu b e a nd th e tu b e is p r e s s u r iz e d. S a m p le flo w b e g ins .

T h e s a m p le p r o b e is c le a ne d a u to m a tic a lly w h e n s a m p le flo w e nds .

Hy d rod y na m ic Focusing

If th e c e lls w e r e to m o v e th r o u g h th e la s e r b e a m in diffe r e nt w a y s du r ing s a m p le flo w , s a m p le a na ly s is c o u ld b e dis to r te d. T h e ins tr u m e nt u s e s a p r o c e s s c a lle d h y dr o dy na m ic fo c u s ing to e ns u r e th a t th e c e lls m o v e th r o u g h th e la s e r b e a m o ne a t a tim e , a lo ng th e s a m e p a th . Hy dr o dy na m ic fo c u s ing o c c u r s in th e flo w c e ll.

T h e flo w c e ll ( F ig u r e 5.1) c o nta ins a r e c ta ng u la r c h a nne l. A p r e s s u r iz e d s tr e a m o f s h e a th flu id e nte r s th e c h a nne l a t th e lo w e r e nd a nd flo w s u p w a rd. T h e s e ns ing a r e a o f th e flo w c e ll is a t th e c e nte r o f th e c h a nne l.

W h ile th e s h e a th s tr e a m is flo w ing th r o u g h th e c h a nne l, a s tr e a m o f s a m p le is inje c te d into th e m iddle o f th e s h e a th s tr e a m . A s s h o w n in F ig u r e 5.1, th e s h e a th s tr e a m s u r r o u nds , b u t do e s no t m ix w ith , th e s a m p le s tr e a m . T h e p r e s s u r e o f th e s h e a th s tr e a m fo c u s e s th e s a m p le s tr e a m s o th a t th e c e lls flo w th r o u g h th e la s e r b e a m s ing le file .

CAUTION Pos s ib le flow cell d amag e. T o avoid clog g ing th e s amp le p rob e, s amp le tub ing or flow cell, ens ure th at 1 2 mm x 7 5 mm tes t tub es are free of d eb ris b efore y ou us e th em.

Page 100: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-2

OPERATION PRINCIPLESSA M P L E F L OW

Fig ure 5.1 Flow Cell (Hy d rod y na m ic Focusing )

b T o w a s te g T o w a s te

c S e ns ing a r e a h a s r e c ta ng u la r c h a nne l h S a m p le s tr e a m e nte r s h e r e

d S a m p le s tr e a m i S h e a th s tr e a m e nte r s h e r e

e S h e a th s tr e a m j D ir e c tio n o f la s e r b e a m

f Ce lls

b

c

de

f

gi

h

j

Page 101: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-3

OPERATION PRINCIPLESL A SER B EA M SH A P ING 5

5.3 LASER BEAM SHAPINGB e fo r e th e la s e r b e a m r e a c h e s th e s a m p le s tr e a m , c r o s s - c y lindr ic a l le ns e s fo c u s th e b e a m ( s e e F ig u r e 5.2) . F o c u s ing k e e p s th e b e a m p e r p e ndic u la r to th e s a m p le s tr e a m flo w w h ile m a k ing th e b e a m s m a ll e no u g h to illu m ina te o nly o ne c e ll a t a tim e .

T h e fir s t le ns c o ntr o ls th e w idth o f th e b e a m ; th e s e c o nd, th e h e ig h t. T h e r e s u lting e llip tic a l b e a m is fo c u s e d o n th e s e ns ing a r e a o f th e flo w c e ll.

Fig ure 5.2 La ser Bea m Sh a p ing

b Cro s s s e c tio n b e fo r e le ns e s g V e r tic a l b e a m s h a p ing le ns

c Cro s s s e c tio n b e fo r e v e r tic a l le ns h La s e r b e a m dir e c tio n

d Cro s s s e c tio n b e fo r e h o r iz o nta l le ns i Ho r iz o nta l b e a m s h a p ing le ns

e T o w a s te j La s e r b e a m

f F lo w c e ll

g

i

j

b

c

d

e

f

h

Page 102: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-4

OPERATION PRINCIPLESCEL L IL L U M INA TION

5.4 CELL ILLUMINATIONA s c e lls in th e s a m p le s tr e a m g o th r o u g h th e s e ns ing a r e a o f th e flo w c e ll, th e e llip tic a l la s e r b e a m illu m ina te s th e m . T h e c e lls s c a tte r th e la s e r lig h t a nd e m it flu o r e s c e nt lig h t fr o m flu o r e s c e nt dy e s a tta c h e d to th e m .

Forw a rd Sca tter

T h e a m o u nt o f la s e r lig h t s c a tte r e d a t na r r o w a ng le s to th e a x is o f th e la s e r b e a m is c a lle d fo r w a rd s c a tte r ( F S ) . T h e a m o u nt o f F S is p r o p o r tio na l to th e s iz e o f th e c e ll th a t s c a tte r e d th e la s e r lig h t.

Sid e Sca tter a nd Fluorescent Lig h t

T h e a m o u nt o f la s e r lig h t s c a tte r e d a t a b o u t a 90 ° a ng le to th e a x is o f th e la s e r b e a m is c a lle d s ide s c a tte r ( S S ) . T h e a m o u nt o f S S is p r o p o r tio na l to th e g r a nu la r ity o f th e c e ll th a t s c a tte r e d th e la s e r lig h t. F o r e x a m p le , S S is u s e d to diffe r e ntia te b e tw e e n ly m p h o c y te s , m o no c y te s , a nd g r a nu lo c y te s .

In a dditio n to th e S S , th e c e lls e m it flu o r e s c e nt lig h t ( F L) a t a ll a ng le s to th e a x is o f th e la s e r b e a m . T h e a m o u nt o f F L e na b le s th e ins tr u m e nt to m e a s u r e c h a r a c te r is tic s o f th e c e lls e m itting th a t lig h t, de p e nding o n th e r e a g e nts u s e d. F o r e x a m p le , F L is u s e d to ide ntify m o le c u le s , s u c h a s c e ll s u r fa c e a ntig e ns .

5.5 LIGHT COLLECTION, SEPARATION AND MEASUREMENT

Forw a rd Sca tter Collection

T h e F S s e ns o r ( s e e F ig u r e 5.3 a nd F ig u r e 5.4) c o lle c ts th e fo r w a rd s c a tte r — th e la s e r lig h t th a t is s c a tte r e d a t na r r o w a ng le s to th e a x is o f th e la s e r b e a m . W h e n lig h t r e a c h e s th e F S s e ns o r, th e s e ns o r g e ne r a te s v o lta g e p u ls e s ig na ls . T h e s e s ig na ls a r e p r o p o r tio na l to th e a m o u nt o f lig h t th e s e ns o r r e c e iv e s . A s e x p la ine d in He a ding 5.6, S IG N A L P R O CE S S IN G , th e s ig na ls a r e p r o c e s s e d to m e a s u r e th e c h a r a c te r is tic s o f th e c e lls th a t s c a tte r e d th e lig h t.

T h e F S s e ns o r c o nta ins a F ie ld S to p th a t a llo w s y o u to c o lle c t diffe r e nt a ng le s o f F o r w a rd S c a tte r. T h e s ta nda rd ( fa c to r y s e t) p o s itio n c o lle c ts F S a ng le s o f 1 to 19° . T h e s e c o nd p o s itio n a llo w s y o u to c o lle c t a lo w e r a ng le o f F S , 1 to 8 ° . S e e P O S I T IO N T HE F I E LD S T O P .

Page 103: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-5

OPERATION PRINCIPLESL IG H T COL L ECTION, SEP A R A TION A ND M EA SU R EM ENT 5

Fig ure 5.3 Op tica l Sy stem w ith Op tiona l Red Solid -sta te La ser

Fig ure 5.4 Op tica l Sy stem w ith Op tiona l HeNe La ser

b Arg on (488) las er f FL 4 j Field s top

c S S s ens or g FL 5 1) FS s ens or

d S olid -s tate (635) las er (op tional) h FL 2 1! Flow cell

e FL 3 i FL 1

b Arg on (488) las er f FL 4 j Field s top

c S S s ens or g FL 5 1) FS s ens or

d H eNe (633) las er (op tional) h FL 2 1! Flow cell

e FL 3 i FL 1

b c d

e

f

g

hij

1)1!

b c

d

e

f

g

hij

1)1!

Page 104: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-6

OPERATION PRINCIPLESL IG H T COL L ECTION, SEP A R A TION A ND M EA SU R EM ENT

Sid e Sca tter a nd Fluorescent Lig h t Collection

In o rde r fo r th e s e ns o r s to m e a s u r e S S a nd F L, th e lig h t m u s t b e c o lle c te d a nd th e S S a nd flu o r e s c e nt lig h t m u s t b e s e p a r a te d.

T h e p ic k u p le ns /s p a tia l filte r a s s e m b ly c o lle c ts S S a nd F L fr o m o nly th e s e ns ing a r e a o f th e flo w c e ll, a nd c o llim a te s it. T h is lig h t th e n g o e s to w a rd th e S S s e ns o r.

Sid e Sca tter

T h e w a v e le ng th o f S S is 48 8 nm . It is m u c h m o r e inte ns e th a n F L. S S is th e fir s t lig h t s e p a r a te d fr o m th e o u tp u t o f th e p ic k u p le ns /s p a tia l filte r a s s e m b ly .

S S is s e p a r a te d u s ing a 48 8 nm dic h r o ic lo ng -p a s s ( 48 8 D L) filte r a t a 45-de g r e e a ng le to th e lig h t p a th ( s e e F ig u r e 5.3, F ig u r e 5.4, F ig u r e 5.6, a nd F ig u r e 5.5) . T h e 48 8 D L filte r r e fle c ts th e S S to th e S S s e ns o r b u t tr a ns m its flu o r e s c e nt lig h t o f lo ng e r w a v e le ng th s .

Fig ure 5.5 Sing le La ser Filter Block Config ura tion

b 48 8 D LP g 67 5 B P 1! 525 B P

c 50 0 LP h 7 10 D LP 1@ 530 S P

d 60 0 D LP i 7 55 LP 1# F lo w c e ll

e 645 D S P j 57 5 B P

f 620 B P 1) 550 D LP

b

cd

e f

g

h

i

j1)1!

1@1#

Page 105: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-7

OPERATION PRINCIPLESL IG H T COL L ECTION, SEP A R A TION A ND M EA SU R EM ENT 5

Fig ure 5.6 Dua l La ser Filter Block Config ura tion

Fluorescent Lig h t

T h e lig h t th e 48 8 D LP filte r tr a ns m its g o e s to a 50 0 nm lo ng p a s s filte r. T h is filte r b lo c k s a ny r e m a ining la s e r lig h t, tr a ns m itting o nly flu o r e s c e nt lig h t. T h e r e m a ining o p tic a l filte r s s e p a r a te th e lig h t fo r th e fiv e F L s e ns o r s . N ote: T h is flu o r e s c e nt lig h t c o lle c tio n de s c r ip tio n a p p lie s to th e D u a l La s e r F ilte r B lo c k Co nfig u r a tio n o nly .

T h e fir s t filte r in th e lig h t p a th ( 50 0 LP ) b lo c k s th e s ide s c a tte r lig h t fr o m th e A r g o n la s e r a nd tr a ns m its a ll th e flu o r e s c e nc e c o lo r s a nd th e s ide s c a tte r lig h t fr o m th e r e d la s e r. T h is a s s e m b ly s e p a r a te s th e c o lle c te d flu o r e s c e nc e s ig na l into fiv e c o lo r b a nds . P MT s 1 to 4 c o lle c t s ig na ls c e nte r e d a p p r o x im a te ly a t 525, 57 5, 610 a nd 67 5 nm . P MT 5 c o lle c ts a s ig na l c e nte r e d a p p r o x im a te ly a t 7 55 nm . Lo ng p a s s filte r s a r e u s e d to tr a ns m it th e s e c o lo r b a nds , b lo c k th e s ide s c a tte r lig h t fr o m th e o p tio na l r e d la s e r a nd p r o v ide a dditio na l b lo c k ing o f th e s ide s c a tte r lig h t fr o m th e A r g o n la s e r. T h e c o lo r b a nds a r e de s ig ne d to m e a s u r e flu o r e s c e nc e lig h t fr o m th e flu o r o c h r o m e s s u c h a s F I T C, P E , E CD , P C5 o r A P C, P C7 e x c ite d b y illu m ina tio n fr o m th e A r g o n a nd th e o p tio na l r e d la s e r s . D ic h r o ic filte r s a r e u s e d to s p lit c o lo r s a t 550 , 60 0 , 645 a nd 7 10 nm . P o s itio ns o f th e dic h r o ic filte r s h a v e b e e n e ffic ie ntly de s ig ne d to r e du c e th e nu m b e r o f o p tic a l s u r fa c e s flu o r e s c e nc e lig h t m u s t p a s s to r e a c h th e p h o to s e ns o r s . T h e ir lo c a tio ns r e la tiv e to th e o p tic a l a x is h a v e a ls o b e e n o p tim iz e d fo r lig h t to p a s s s y m m e tr ic a lly th r o u g h e a c h filte r. Y o u c a n indiv idu a lly inte rc h a ng e th e o p tic a l filte r s . A s m a ll p la te h o lds a ll th e o p tic a l filte r s u s e d to s e p a r a te flu o r e s c e nc e s ig na ls a llo w ing fo r e a s y inte rc h a ng e o f g r o u p s o f filte r s . T h e filte r s a r e p r e c is e ly m o u nte d in th e ir h o u s ing a nd th e filte r p la te is p r e c is e ly m o u nte d o n th e o p tic a l p la te . T h e r e is no ne e d to r e a lig n th e o p tic a l s y s te m w h e n th e filte r s o r th e filte r p la te a r e c h a ng e d.

b 48 8 D LP g 67 5 B P 1! 525 B P

c 50 0 LP h 7 10 D LP 1@ 530 S P

d 60 0 D LP i 7 55 LP 1# F lo w c e ll

e 615 D S P j 57 5 B P

f 620 S P 1) 550 D LP

b

cd

e f

g

h

i

j1)1!

1@1#

Page 106: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-8

OPERATION PRINCIPLESSIG NA L P R OCESSING

5.6 SIGNAL PROCESSING

Volta g e Pulse Sig na ls

T h e Cy to m e te r h a s s e v e n s e ns o r s , e a c h g e ne r a ting a v o lta g e p u ls e s ig na l a s e a c h c e ll p a s s e s th r o u g h th e la s e r b e a m . A v o lta g e p u ls e s ig na l is p r o p o r tio na l to th e inte ns ity o f lig h t th e s e ns o r r e c e iv e d. T h e Cy to m e te r e le c tr o nic s a m p lifie s , c o nditio ns , inte g r a te s , a nd a na ly z e s th e s e p u ls e s .

Pea k Sig na l

F ig u r e 5.7 s h o w s h o w a p e a k v o lta g e p u ls e s ig na l fo r m s a s a c e ll c r o s s e s th e la s e r b e a m .

r P a r t I o f F ig u r e 5.7 s h o w s w h e n th e c e ll e nte r s th e la s e r b e a m a nd s o m e lig h t is s c a tte r e d.

r P a r t II o f F ig u r e 5.7 s h o w s w h e n th e c e ll is in th e c e nte r o f th e la s e r b e a m a nd th e s c a tte r e d lig h t, a nd th e r e fo r e , th e p u ls e h e ig h t, r e a c h e s a m a x im u m .

r P a r t II I o f F ig u r e 5.7 s h o w s w h e n th e c e ll le a v e s th e la s e r b e a m a nd th e s c a tte r e d lig h t de c r e a s e s .

T h e inte ns ity o f lig h t s c a tte r o r flu o r e s c e nc e de te r m ine s th e h e ig h t o f th e p e a k p u ls e ( s e e F ig u r e 5.7 ) . T h e tim e th e p a r tic le is in th e la s e r b e a m de te r m ine s th e w idth o f th e p u ls e . T h e r e fo r e , th e to ta l flu o r e s c e nc e ( inte ns ity a nd tim e ) de te r m ine s th e a r e a u nde r th e p u ls e . F ig u r e 5.8 s h o w s h o w th r e e c e lls w ith th e s a m e a m o u nt o f to ta l flu o r e s c e nc e b u t w ith diffe r e nt flu o r e s c e nc e inte ns itie s , p r o du c e diffe r e nt p e a k p u ls e s .

Page 107: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-9

OPERATION PRINCIPLESSIG NA L P R OCESSING 5

Fig ure 5.7 Volta g e Pulse Form a tion, Pea k Sig na l

b La s e r b e a m e T im e

c Ce ll f P u ls e h e ig h t

d V o lts

b c

d

e

b

d

e

c

b

c

d

e

f

I

II

III

Page 108: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-1 0

OPERATION PRINCIPLESSIG NA L P R OCESSING

Integ ra l Sig na l

B e c a u s e th e to ta l flu o r e s c e nc e in a ll th r e e c e lls is th e s a m e , b u t th e dis tr ib u tio n is diffe r e nt, th e p u ls e c a n b e inte g r a te d to p r o du c e a n inte g r a l s ig na l ( s e e F ig u r e 5.8 ) .

T h e h e ig h t o f th e inte g r a l p u ls e is p r o p o r tio na l to th e to ta l flu o r e s c e nc e a nd is o b ta ine d w h e n th e c e ll e x its th e la s e r b e a m . T h e p u ls e h e ig h t, h o w e v e r, r e p r e s e nts th e m o s t inte ns e a m o u nt o f flu o r e s c e nc e p r o du c e d. T h e a r e a u nde r th e p u ls e is p r o p o r tio na l to th e to ta l flu o r e s c e nc e .

Fig ure 5.8 Integ ra l a nd Pea k Pulses

Am p lifica tion

S o m e v o lta g e p u ls e s m u s t b e a m p lifie d s o th a t th e c h a r a c te r is tic s o f th e c e lls c a n b e m e a s u r e d.

T h e s y s te m le ts y o u :

r Inc r e a s e th e g a in to line a r ly a m p lify th e inte g r a l a nd p e a k s ig na ls .

r Lo g a r ith m ic a lly tr a ns fo r m th e line a r da ta .

A lo g a r ith m ic tr a ns fo r m a tio n a c c e ntu a te s th e diffe r e nc e s b e tw e e n th e s m a lle r p u ls e s a nd r e du c e s th e diffe r e nc e s b e tw e e n th e la r g e r p u ls e s .

Sig na ls Genera ted

T h e ins tr u m e nt s e ns o r s c a n g e ne r a te th e s e s ig na ls ( inte g r a l u nle s s s ta te d o th e r w is e ; LO G s ta nds fo r lo g a r ith m ic ) :

b D ir e c tio n o f s a m p le flo w e V o lts h V o lts

c Ce ll in la s e r b e a m f T im e i T im e

d P e a k p u ls e s g Inte g r a l p u ls e s

b

c

d e

f

i

g h

Page 109: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-1 1

OPERATION PRINCIPLESP R OTOCOL S 5

r F S , F S LO G , F S P E A K

r S S , S S LO G , S S P E A K

r F L1, F L1 LO G , F L1 P E A K

r F L2, F L2 LO G , F L2 P E A K

r F L3, F L3 LO G , F L3 P E A K

r F L4, F L4 LO G , F L4 P E A K

r F L5, F L5 LO G , ( F L5 u s e s th e A U X s ig na l p a th w a y ) .

F o r a ny g iv e n s a m p le , th e ins tr u m e nt c a n c r e a te u p to e ig h t o f th e s e s ig na ls , p lu s th e P r is m , T IME , a nd R A T I O p a r a m e te r s .

5.7 PROTOCOLSA P r o to c o l is a c o lle c tio n o f info r m a tio n a b o u t h o w th e Cy to m e te r a nd CX P s o ftw a r e is s e t u p . P r o to c o ls c a n b e c r e a te d fo r a c q u ir ing s a m p le s o r a na ly z ing s to r e d da ta .

It c o nta ins th e fo llo w ing info r m a tio n:

r D is p la y c o nfig u r a tio n

r P a r a m e te r na m e s a nd c o nfig u r a tio n

r R e g io ns

r G a te s

r Co lo r de finitio ns

r S ta tis tic s

r Ins tr u m e nt s e tting s

r R e p o r ting T e m p la te s

Sp ecia l Protocols a nd Pa nels

T h e r e a r e th r e e c a te g o r ie s o f s p e c ia l P r o to c o ls : Q C, Cle a ns e a nd A S .

Q C P r o to c o ls ( E x p o r t) : A ny P r o to c o l na m e b e g inning w ith th e c h a r a c te r s “ Q C” ( u p p e r- c a s e o nly ) o v e r-r ide s th e c u r r e nt E x p o r t D a ta F o r m a t s e tting o n th e W o r k s p a c e P r e fe r e nc e s / P u b lis h ta b c a u s ing P u b lis h e d da ta to b e fo r m a tte d a s a s ing le r o w o f v a lu e s . In th e c a s e th a t th e P u b lis h D a ta to MS E x c e l o p tio n is s e le c te d, th is p r o g r e s s iv e ly b u ilds a ta b le o n a s ing le s p r e a ds h e e t.

Cle a ns e P r o to c o ls : A ny P r o to c o l na m e b e g inning w ith th e w o rd “ Cle a ns e ” o v e r r ide s th e O u tp u t O p tio ns s e tting fo r S a v e LMD o n th e W o r k s p a c e P r e fe r e nc e s - A c q u is itio n O p tio ns ta b . T h is a llo w s y o u to c r e a te p r o to c o ls th a t do no t w r ite a lis tm o de file to dis k o n c o m p le tio n.

A S P r o to c o ls : T h e r e is a s e r ie s o f s p e c ia l p r o to c o ls w h ic h inc lu de “ A S ” in th e ir na m e s . T h e s e a r e c o m p o ne nts o f th e A u to S e tu p a p p lic a tio ns w h ic h o p e r a te w ith th e A u to S e tu p W iz a rd to s e t u p V o lts , G a ins a nd Co m p e ns a tio n.

Sp ecia l Pa nels

T h e c le a ns e p a ne l u tiliz e s tw o c le a ns e p r o to c o ls ( ‘c le a ns e b le a c h .P R O ’ a nd ‘c le a ns e di w a te r.P R O ) th a t y o u s h o u ld u s e a t th e e nd o f th e w o r k ing da y o r s h ift o n y o u r F C 50 0 .

Page 110: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-1 2

OPERATION PRINCIPLESA U TOM A TED SOFTW A R E F EA TU R ES

5.8 AUTOMATED SOFTWARE FEATURESCX P s o ftw a r e c o nta ins th e fo llo w ing a u to m a te d s o ftw a r e fe a tu r e s .

r A u to S e tu p W iz a rd

r Q u ic k CO MP

r Q u ic k S E T

r A u to m a tic G a te Cre a tio n

r A u to m a tic G a te Ma inte na nc e

r E llip tic a l a nd Co nto u r A u to G a ting

r A u to MA T O R A na ly s is

5.9 PARAMETERS

AUX ilia ry Pa ra m eter

T h e A U X s ig na l is a v a ila b le to c o lle c t a P e a k s ig na l fr o m a ny o f th e de te c te d p a r a m e te r s w h e n a na ly z ing u p to fo u r c o lo r s . W h e n u s ing F L5 o r a na ly z ing fiv e c o lo r s th e A U X s ig na l is no t a v a ila b le . F o r a ny g iv e n s a m p le , o nly o ne o f th e fo llo w ing s ig na ls c a n b e a s s ig ne d to A U X :

r F S , F S P E A K

r S S , S S P E A K

r F L1, F L1 P E A K

r F L2, F L2 P E A K

r F L3, F L3 P E A K

r F L4, F L4 P E A K

Wh en to Use th e AUX Pa ra m eter

W h e n y o u s p e c ify b o th line a r a nd lo g a r ith m ic a m p lific a tio n o f th e s a m e s ig na l, th e g a in fo r th e line a r a m p lific a tio n is a ls o a p p lie d to th e lo g a r ith m ic a m p lific a tio n. Ho w e v e r, w h e n y o u s p e c ify o nly lo g a r ith m ic a m p lific a tio n o f a s ig na l, th e ins tr u m e nt a u to m a tic a lly s e ts th e g a in fo r th a t s ig na l to 1.0 , a nd y o u c a nno t c h a ng e it.

U s e th e A U X p a r a m e te r w h e n y o u w a nt to :

r A m p lify a s ig na l a t tw o diffe r e nt g a ins .

r O b s e r v e a p e a k s ig na l o r inte g r a l s ig na l a t th e s a m e tim e a s th e lo g s ig na l.

r O b s e r v e a p e a k s ig na l a t th e s a m e tim e a s th e inte g r a l s ig na l.

A ls o , th e A U X p a r a m e te r m a y b e u s e d fo r do u b le t dis c r im ina tio n. A s s ig n a p e a k flu o r e s c e nc e s ig na l to A U X s o y o u c a n m e a s u r e p e a k v s . inte g r a l flu o r e s c e nc e .

TIME Pa ra m eter

T h e T IME p a r a m e te r is th e a m o u nt o f tim e , in s e c o nds , th e ins tr u m e nt a c q u ir e s da ta . I t is dis p la y e d o n th e p lo t a x is in 1-s e c o nd r e s o lu tio n. T h e a x is la b e ls v a r y, de p e nding o n p lo t r e s o lu tio n a nd s to p tim e ( du r a tio n) .

Page 111: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-1 3

OPERATION PRINCIPLESP L OT D ISP L A Y 5

T h e m inim u m s to p tim e is 10 s e c o nds , th e m a x im u m s to p tim e ( m a x im u m du r a tio n) is 99,999 s e c o nds a nd th e de fa u lt s to p tim e is 30 0 s e c o nds ( 5 m inu te s ) .

W h e n y o u a s s ig n th e T IME p a r a m e te r to a p lo t a x is , th e div is io ns o n th e a x is c h a ng e a c c o rding ly .

T o find th e tim e ( in s e c o nds ) p e r c h a nne l in a o ne -p a r a m e te r h is to g r a m , div ide th e s to p tim e ( in s e c o nds ) b y 1,0 24 ( 0 .0 0 1 s e c o nd = 1.0 m s ) .

F o r a tw o - p a r a m e te r p lo t, div ide b y 64, 128 , 256 o r 512 de p e nding u p o n th e p lo t r e s o lu tio n y o u a r e u s ing .

RATIO Pa ra m eter

T h e R A T I O p a r a m e te r is c a lc u la te d, no t a c q u ir e d dir e c tly . W h e n y o u s e le c t a p a r a m e te r, y o u s p e c ify w h ic h s ig na l is th e nu m e r a to r a nd w h ic h is th e de no m ina to r .

A r a tio o f 1 is a t c h a nne l 1,0 23. If y o u a s s ig n R A T IO to a p lo t a x is , R A T IO e v e nts a p p e a r a t a lo w e r c h a nne l if th e inte ns ity o f th e nu m e r a to r s ig na l is le s s th a n th e de no m ina to r s ig na l.

T o c a lc u la te th e a c tu a l r a tio a t a p a r tic u la r inte ns ity fo r a o ne -p a r a m e te r h is to g r a m , div ide th e inte ns ity b y 1,0 24. F o r a tw o - p a r a m e te r p lo t, div ide b y 64, 128 , 256 o r 512 de p e nding u p o n th e p lo t r e s o lu tio n y o u a r e u s ing .

5.10 PLOT DISPLAYT h e r e s u lts o f s a m p le a na ly s is a p p e a r o n th e W o r k s ta tio n s c r e e n a s g r a p h s c a lle d p lo ts . Y o u a s s ig n th e p a r a m e te r s to th e p lo t a x e s . P lo ts c a n b e dis p la y e d in b la c k a nd w h ite o r c o lo r a s :

r S ing le - p a r a m e te r h is to g r a m p lo t

r D u a l- p a r a m e te r do t p lo t

r D u a l- p a r a m e te r c o nto u r p lo t ( CX P A na ly s is S o ftw a r e o nly )

r D u a l- p a r a m e te r de ns ity p lo t

r D u a l- p a r a m e te r s u r fa c e p lo t

r S ing le - p a r a m e te r P r is m p lo t

r O v e r la y e d h is to g r a m p lo ts ( CX P A na ly s is S o ftw a r e o nly )

r 3-D to m o g r a m p lo t ( CX P A na ly s is S o ftw a r e o nly ) .

D u a l- p a r a m e te r p lo ts c a n b e dis p la y e d in 64 x 64, 128 x 128 , 256 x 256, o r 512 x 512 r e s o lu tio n. P lo ts c a n b e dis p la y e d o n a b la c k o r w h ite b a c k g r o u nd.

PRISM

P r is m is u s e d to a na ly z e m u ltic o lo r im m u no flu o r e s c e nc e s a m p le s . W ith m u ltic o lo r im m u no flu o r e s c e nc e a c e ll is e ith e r p o s itiv e o r ne g a tiv e fo r e a c h o f tw o , th r e e , fo u r o r fiv e c e ll s u r fa c e m a r k e r s . A p a r tic u la r c o m b ina tio n is c a lle d a p h e no ty p e . P r is m a llo w s y o u to dis p la y p e rc e nta g e s o n a ll p h e no ty p ic p o p u la tio ns in a s ing le p lo t. It is s o ftw a r e de r iv e d a nd c a n b e a c q u ir e d in e ith e r r u n tim e o r lis tm o de .

RATIONumerator

Denominator----------------------------------- 1024×=

Page 112: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-1 4

OPERATION PRINCIPLESP L OT D ISP L A Y

P r is m is a v a ila b le o n u p to fiv e p a r a m e te r s . T IME , R A T IO , a nd P r is m its e lf c a nno t b e u s e d fo r P r is m . A ll o th e r s ig na ls c a n b e u s e d fo r P r is m . G e ne r a lly , F L1, F L2, F L3, F L4, a nd F L5 a r e u s e d.

A P r is m p lo t s h o w s a s p ik e o r p o p u la tio n fo r e a c h a ntib o dy c o m b ina tio n w ith a p e r c e nt o f th e to ta l th a t r e p r e s e nts th e p e rc e nt o f th e to ta l e v e nts in th e P r is m p lo t. S e e F ig u r e 5.9.

Fig ure 5.9 Prism Plot

S e e P r is m P lo t fo r ins tr u c tio ns o n u s ing P r is m .

Page 113: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-1 5

OPERATION PRINCIPLESP L OT D ISP L A Y 5

Reg ions

T o a na ly z e da ta o r g a te p lo ts , y o u m u s t fir s t c r e a te a nd a s s ig n r e g io ns to th e s e ta s k s . Y o u c a n c r e a te fiv e diffe r e nt ty p e s o f r e g io ns ( s e e R e g io ns Intr o du c tio n) . T h e r e g io n ty p e s a r e :

r Line a r

r R e c ta ng u la r

r Q u a dr a nt

r P o ly g o na l

r E llip tic a l

r Co nto u r

r O n O v e r la y e d h is to g r a m s o nly

r Link e d m a r k e r

r N o n-link e d m a r k e r

O nc e a r e g io n is c r e a te d it c a n b e a s s ig ne d to fu nc tio n in a s p e c ific w a y . T h e fu nc tio ns th a t a r e a v a ila b le inc lu de :

r A na ly s is

r P r im e

r CA L ( c a lib r a tio n)

r G a ting

r Lis tm o de g a ting ( LIV E G A T E )

r Co nto u r A u to G a te

r E llip tic a l A u to G a te

r P o s itiv e s a na ly s is

r Minim u m Co u nt.

T h e s e fu nc tio ns a r e no t a v a ila b le fo r a ll r e g io n ty p e s .

Ga ting

T h e s o ftw a r e le ts y o u u s e g a ting to s p e c ify th a t o nly c e r ta in c e lls a r e to b e a na ly z e d. A g a te c a n b e de fine d a s th e c e lls th a t a r e ins ide o r o u t o f o ne o r m o r e r e g io ns .

Da ta Stora g e

S a m p le r e s u lts c a n b e p r inte d o u t, s a v e d to a dis k e tte o r o th e r r e m o v a b le m e dia , s a v e d to a lo c a l h a rd dr iv e o r s a v e d to a ne tw o r k dr iv e . Y o u c a n s to r e s a m p le r e s u lts in th e fo r m o f a lis t o f th e m e a s u r e m e nts fr o m e a c h c e ll, c a lle d lis tm o de da ta . Lis tm o de da ta c a n b e r e p la y e d into p lo ts o r a rc h iv e d fo r a na ly s is la te r. P lo ts c a n a ls o b e s a v e d to a file .

Page 114: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-1 6

OPERATION PRINCIPLESP L OT D ISP L A Y

Histog ra m Sta tistics

Linea r Reg ion Sta tistics

F o r line a r s ig na ls , s ta tis tic s fo r h is to g r a m r e g io ns a r e c a lc u la te d a s fo llo w s :

N u m b e r = N u m b e r o f c e lls in th e r e g io n

Mo de = Inte ns ity c o nta ining th e la r g e s t nu m b e r o f c e lls w ith in th e r e g io n.

W h e r e δ = S ta nda rd de v ia tio nCV = Co e ffic ie nt o f V a r ia tio nMH = Hig h r e g io n m a r k e r c h a nne l

ML = Lo w r e g io n m a r k e r c h a nne l

Cn = R a w dig ita l c h a nne l nu m b e r

Cc h = Ch a nne l c o u nt

N = Inte g r a l o f a ll c o u nts b e tw e e n & inc lu ding m a r k e r c h a nne ls

= Me a n c h a nne l nu m b e r ( r o u nde d to ne a r e s t w h o le c h a nne l)

F o r Me a n a nd S D , th e s u m m a tio ns a r e p e r fo r m e d o v e r a ll th e c h a nne ls th a t lie w ith in th e r e g io n.

Me dia n inte ns ity = th e s m a lle s t inte ns ity s u c h th a t s u m ( inte ns ity ) ≥

S u m ( inte ns ity ) = s u m o f e v e nts fr o m th e lo w e r e dg e o f th e r e g io n to th e inte ns ity

totalNumb er of ev ents in reg ion

Total numb er of ev ents in th e g ated d is p lay-------------------------------------------------------------------------------------------------------- 100×=

totalNumb er of c ells in reg ion

Total numb er of c ells in th e file---------------------------------------------------------------------------- 100×=

! "#

$%&

'=

H

L

M

M

chn

N

CC *Mean

( )! −=

H

L

M

M

n

N

XC2

SD

100CV ×=X

δ

X

M ean med ian intens ity 0.5

s um med ian intens ity( )area

2-----------–

c ount in med ian intens ity------------------------------------------------------------------------------–+=

area

2-----------

Page 115: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 5-1 7

OPERATION PRINCIPLESP L OT D ISP L A Y 5

W h e r e F W HM= th e F u ll W idth Ha lf Ma x v a lu e o f a N o r m a l o r G a u s s ia n p e a k .

Log Reg ion Sta tistics

T h e m e th o d o f g e o m e tr ic c a lc u la tio ns o f Me a ns de p e nds o n y o u r A dv a nc e d S ta tis tic s Co nfig u r a tio n.

Log -Log Mea n Meth od

W e ig h ting e a c h c h a nne l a c c o rding to its fa c e v a lu e a s g iv e n b y th e lo g s c a le p e r fo r m s th is c a lc u la tio n o f Me a n.

E x a m p le

W h e n u s ing a fo u r-de c a de u nc a lib r a te d lo g a r ith m ic dis p la y r e p o r ting o u tp u t a s Ch a nne ls ,

y o u m ig h t g iv e c h a nne l z e r o ( th e lo w e s t c h a nne l) a v a lu e 10 -1 = 0 .1 a nd o n a 10 24 c h a nne l

dis p la y , c h a nne l 10 23 is g iv e n th e v a lu e 10 -3 = 10 0 0 . A ll r a w dig ita l c h a nne l v a lu e s a r e c o nv e r te d to a n a b s o lu te v a lu e ( R e la tiv e Ch a nne l N u m b e r ) in th e r a ng e 0 .1 to 10 0 0 b e fo r e c a lc u la tio ns a r e p e r fo r m e d fo r th e m e a n.

T h e m e a n c a n th e n b e r e p o r te d in Ch a nne l nu m b e r s in th e r a ng e 0 to 10 23 th u s :

W h e r e :Cn = R a w dig ita l c h a nne l nu m b e r

Cc h = Ch a nne l c o u nt

Cd = Ch a nne ls p e r de c a de

N = Inte g r a l o f a ll c o u nts b e tw e e n & inc lu ding m a r k e r c h a nne ls

= Me a n c h a nne l nu m b e r ( r o u nde d to ne a r e s t w h o le c h a nne l)

F o r Ca lib r a te d v a lu e s , th e c a lc u la tio n is r e p o r te d a s th e c a lib r a te d v a lu e in th e r a ng e Lo g O ffs e t to

T h e lo g o ffs e t c a nno t b e z e r o s inc e a lo g o ffs e t o f z e r o is 10 ( m inu s infinity ) , w h ic h is no t p o s s ib le to r e p r e s e nt o n p a p e r o r o n s c r e e n. CX P s o ftw a r e do e s no t a llo w lo g o ffs e t v a lu e s o f le s s th a n 0 .1. N u m b e r s e nte r e d in th e lo g a r ith m ic o ffs e t a r e c la m p e d a t 0 .1 if a nu m b e r le s s th a n th is is e nte r e d.

H alf P eak C VF W H M

2.3 5 4-------------------=

"""""

#

$

%%%%%

&

'"#

$%&

'

!=Mh

M

ch

dchannels

L

d

n

N

CC

C

LOGCX

*

10

10

*

X

""

#

$

%%

&

'=

d

Channels

C

XOffsetLogX 10*_

Page 116: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B5-1 8

OPERATION PRINCIPLESP L OT D ISP L A Y

Lin-Log Mea n Meth od

T h is m e th o d o f Me a n c a lc u la tio n is w o r k e d o u t b y p e r fo r m ing a s im p le a r ith m e tic m e a n c h a nne l c a lc u la tio n o n r a w da ta a c c o rding to its c h a nne l v a lu e in th e r a ng e 0 to 10 23 ( fo r 10 24 c h a nne l da ta ) . T h e Me a n v a lu e c a n th e n b e r e p o r te d a s c h a nne ls ( in th e r a ng e 0 to 10 23) o r c o nv e r te d to th e R e la tiv e Ch a nne l v a lu e .

U s ing th e s a m e da ta a s in th e p r e v io u s e x a m p le …

Lin-Lo g Me a n m e th o d r e p o r te d in Ch a nne l nu m b e r s in th e r a ng e 0 -10 23 th u s :

W h e r e :Cn = R a w dig ita l c h a nne l nu m b e r

Cc h = Ch a nne l c o u nt

Cd = Ch a nne ls p e r de c a de

N = Inte g r a l o f a ll c o u nts b e tw e e n & inc lu ding m a r k e r c h a nne ls

= Me a n c h a nne l nu m b e r ( r o u nde d to ne a r e s t w h o le c h a nne l)

F o r c a lib r a te d v a lu e s , th e Me a n c a lc u la tio n is r e p o r te d a s a v a lu e in th e r a ng e Lo g O ffs e t to

( Lo g o ffs e t* 10 D e c a de s F u ll S c a le ) th u s :

T h e lo g o ffs e t c a nno t b e z e r o s inc e a lo g o ffs e t o f z e r o is 10 ( m inu s infinity ) . S inc e th e g r a p h ic a l s c a le is a c tu a lly p r o p o r tio na l to th e e x p o ne nt, it is no t p o s s ib le to r e p r e s e nt th is o n p a p e r o r o n s c r e e n. B e c a u s e o f th is p r o b le m , CX P s o ftw a r e do e s no t a llo w lo g o ffs e t v a lu e s o f le s s th a n 0 .1. N u m b e r s e nte r e d in th e Lo g a r ith m ic O ffs e t e dit w indo w a r e c la m p e d a t 0 .1 if a nu m b e r le s s th a n 0 .1 is e nte r e d.

! "#

$%&

'=Χ

H

L

M

M

chnchannels

N

CC *

X

""

#

$

%%

&

'=

d

Channels

C

XOffsetLogX 10*_

Page 117: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-1

66TROUBLESHOOTING

6.1 PRECAUTIONS/HAZ ARDS

La ser/Ra d ia tion Preca utions

T h e Cy to m e te r a nd th e MCL b a r-c o de r e a de r e a c h c o nta in a la s e r. T h e Cy to m e te r c a n a ls o inc lu de a n o p tio na l s e c o nd la s e r. B e c k m a n Co u lte r 's de s ig n a nd m a nu fa c tu r e o f th e ins tr u m e nt c o m p lie s w ith th e r e q u ir e m e nts g o v e rning th e u s e a nd a p p lic a tio n o f a la s e r a s s p e c ifie d in r e g u la to r y do c u m e nts is s u e d b y th e :

r U .S . D e p a r tm e nt o f He a lth a nd Hu m a n S e r v ic e s a nd

r Ce nte r fo r D e v ic e s a nd R a dio lo g ic a l He a lth ( CD R H) .

In c o m p lia nc e w ith th e s e r e g u la to r y do c u m e nts , e v e r y m e a s u r e h a s b e e n ta k e n to e ns u r e th e h e a lth a nd s a fe ty o f u s e r s a nd la b o r a to r y p e r s o nne l fr o m th e p o s s ib le da ng e r s o f la s e r u s e .

U s e th e ins tr u m e nt a c c o rding to th e info r m a tio n in th e m a nu a ls .

U s e o f c o ntr o ls o r a dju s tm e nts o r p e r fo r m a nc e o f p r o c e du r e s o th e r th a n th o s e s p e c ifie d h e r e in m ig h t r e s u lt in h a z a rdo u s r a dia tio n e x p o s u r e .

T o e ns u r e y o u r s a fe ty , th e Cy to m e te r la s e r s a r e c o v e r e d w ith p r o te c tiv e s h ie lds . D o no t r e m o v e th e s e s h ie lds .

N o u s e r- s e r v ic e a b le a s s e m b lie s a r e a c c e s s ib le . D o no t a tte m p t to r e m o v e th e la s e r o r o p e n it.

T h e ins tr u m e nt h a s c o m p o ne nts th a t a r e da ng e r o u s to th e o p e r a to r. If a ny a tte m p t h a s b e e n m a de to de fe a t a s a fe ty fe a tu r e , o r if th e ins tr u m e nt fa ils to p e r fo r m a s de s c r ib e d in its m a nu a ls , dis c o nne c t th e p o w e r a nd c a ll y o u r B e c k m a n Co u lte r R e p r e s e nta tiv e .

La ser Wa rning La b els

CD R H-r e q u ir e d w a rning la b e ls a r e p la c e d ne a r o r o n c o v e r s th a t, if r e m o v e d, m ig h t e x p o s e la s e r r a dia tio n. T h e y a r e a ls o p la c e d ne a r o p e ning s th a t, if lo o k e d into , m ig h t e x p o s e y o u to la s e r r a dia tio n.

CD R H-r e q u ir e d w a rning la b e ls a r e lo c a te d:

S e e F ig u r e 6.1 fo r th e S e ns ing Co m p a r tm e nt c o v e r w a rning la b e l.

S e e F ig u r e 6.2 fo r th e O p tic a l A r e a ( fr o nt v ie w ) w a rning la b e ls .

S e e F ig u r e 6.3 fo r th e O p tic a l A r e a ( inte r io r v ie w ) w a rning la b e ls .

S e e F ig u r e 6.4 fo r th e A r g o n La s e r He a d w a rning la b e ls .

S e e F ig u r e 6.5 fo r th e o p tio na l r e d S o lid-s ta te La s e r w a rning la b e ls .

S e e F ig u r e 6.6 fo r th e lo c a tio n o f th e o p tio na l r e d S o lid-s ta te La s e r in th e ins tr u m e nt.

S e e F ig u r e 6.7 fo r th e o p tio na l r e d He liu m -N e o n La s e r w a rning la b e ls .

S e e F ig u r e 6.8 fo r th e lo c a tio n o f th e o p tio na l r e d He liu m -N e o n La s e r in th e ins tr u m e nt.

S e e F ig u r e 6.9 fo r th e Cy to m e te r b a c k p a ne l la s e r la b e ls .

S e e F ig u r e 6.10 fo r th e MCL p r o b e h o u s ing w a rning la b e ls .

S e e F ig u r e 6.11 fo r th e MCL b a r- c o de r e a de r w a rning la b e ls .

Page 118: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-2

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S

Fig ure 6.1 La ser La b els on th e Sensing Com p a rtm ent Cov er

7 27 2009A

AVOID EYE OR SKINEXPOSURE TO DIRECT ORSCATTERED RADIATION

VISIB L E AND/OR INVISIB L EL ASER RADIATION W H EN OPENL ASER RADIATION

AVOID EXPOSURE TO B EAMCL ASS 3 B L ASER PRODUCT

Page 119: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-3

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S 6

Fig ure 6.2 La ser La b els in th e Op tica l Area , Front View

A V OID EX POSU RE

A V OID EX POSU REVISIB L E AND/ORINVISIB L E L ASER

RADIATION ISEM ITTED F ROM

TH IS APERTURE.

VISIB L E AND/OR INVISIB L EL ASER RADIATION W H EN OPEN

AVOID EYE OR SKINEXPOSURE TO DIRECT ORSCATTERED RADIATION

7 2 7 2 0 0 6 A

Page 120: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-4

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S

Fig ure 6.3 La ser La b els in th e Op tica l Area , Interior View

7 27 407 8A

AVOID EYE OR SKINEXPOSURE TO DIRECT ORSCATTERED RADIATION

VISIB L E AND/OR INVISIB L EL ASER RADIATION W H EN OPEN

CA U TIONLa s e r r a d ia tio n w h e n o p e n

a n d in te r lo c k d e fe a te d .

D O N OT STA RE IN TO B EA M.

A V OID EX POSU RE

VISIB L E AND/OR INVISIB L EL ASER RADIATION IS EM ITTED

F ROM TH IS APERTURE.

Page 121: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-5

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S 6

Fig ure 6.4 La ser La b els on th e Arg on La ser Hea d

Fig ure 6.5 La ser La b els for Op tiona l Red Solid -sta te La ser

7 27 2007 A

L ASER RADIATION-AVOIDDIRECT EXPOSURE TO B EAM

ARG ON/.5 0 W ATT C.W .

CL ASS IIIb L ASER PRODUCTA V OID EX POSU RE

L ASER RADIATIONIS EM ITTED F ROMTH IS APERTURE

L ASER RADIATION W H EN OPEN

AVOID DIRECT EXPOSURE TO B EAM

Redflame

CLO

SE

A V OID EX P OSU R E

LA SER R A D IA T ION EM IT T ED

F R OM T H IS A P ER T U R E

LASER RADIATION

W A V ELEN G T H /P OW ER

P A R T N U M B ER /R EV ISION

SER IA L N U M B ER

B EA M

OP T ION S

A V OID EX P OSU R E T O B EA M CLA SS lllB

CD R H LA SER P R OD U CT CLA SS 3 b

LA SER P ER EN 6 0 8 2 5 -1

P EA K P OW ER 3 0 m W

2 3 0 3 LIN D B ER G H ST .

A U B U R N , CA 9 5 6 0 2 -9 5 9 5

T H IS P R OD U CT D OES N OT COM F OR M T O

T H E A P P LICA B LE ST A N D A R D S OF 2 1 CF R 1 0 4 0 .

COH ER EN T

1 0 0 8 0 5 5 3 /A B

6 3 8 n m /2 2 m W

X X X X X

1 m m CIR CU LA R

N /A

7 3 1 8 2 1 0 B

Page 122: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-6

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S

Fig ure 6.6 Loca tion of th e Op tiona l Red Solid -sta te La ser in th e Instrum ent, Rea r View

Fig ure 6.7 La ser La b els for Op tiona l Red Helium -Neon La ser

b S olid -s tate las er h ead c M ounting p late d Protective h ous ing

FI BE

RAN

RE

SC OP E

SCOPE

FLOWCEL WAST

WAST PRESSURE VAC UUM

LOGIC ANALOG OPTI

M anu fa ct ur ed

D A T E b y CO U L T E R CO R P O R AT IO

1 1 800 S . W . 1 4 7 AV E

M I AM I, FL 33 1 96- 250

T H IS L AS E R PR O D U C T CO NF O R M S T O T H E PR O V IS IO NS O F 21 CF R .

S U BC H A PT E R J, S E CT IO NS 1 0 40 .1 AN D 040. 1 1 .

POWER MO DUL CONTRO

VI SI B L E AN D/ OR IN VI SI B L

L A SER RA DI AT IO N W H EN OP EN

MCL PO WE

5 5 7 1 0 1 9 A

COHERENT

cb d

JDS Uniphase1 096 M ellon AvenueM anteca, CA 95337

M O D E L M ANU FACT U R E D S E R IAL NO .

T H IS L AS E R PR O D U CT CO M PL IE SW IT H 21 CFR 1 040 AND

IE C 825-1 : 1 993.

S E E INS T AL L AT IO N INS T R U CT IO NS .

PAT E NT NO SM AD E

INU S A

L AS E R R AD IT IO NAV O ID E X PO S U R E T O BE AM

CL AS S 3B L AS E R PR O D U CT (IE C)CL AS S IIIb L AS E R PR O D U CT (CD R H )

633 nm / 35 mW

LAS

ER R

AD

ATIO

NIS

EM

ITTE

D F

RO

MTH

IS A

PER

TUR

E

AV

OID

EX

PO

SU

RE

CLOSED OPENBEAM SHUTTER

PL ANE O F PO L AR IZ AT IO N

JDS Unip

hase

7 27 2002A

Page 123: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-7

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S 6

Fig ure 6.8 Loca tion of th e Op tiona l Red Helium -Neon La ser in th e Instrum ent, Rea r View

Fig ure 6.9 La ser La b els on th e Cy tom eter Ba ck Pa nel

b H eNe las er h ead c M ounting p late d Protective h ous ing

FI BE

RAN

RE

SC OP E

SCOPE

FLOWCEL WAST

WAST PRESSURE VAC UUM

LOGIC ANALOG OPTI

M anu fa ct ur ed

D A T E b y

CO U L T E R CO R P O R AT IO

1 1 800 S . W . 1 4 7 AV E

M I AM I, FL 33 1 96- 250

T H IS L AS E R PR O D U C T CO NF O R M S T O T H E PR O V IS IO NS O F 21 CF R .

S U BC H A PT E R J, S E CT IO NS 1 0 40 .1

AN D 040. 1 1 .

POWER MO DUL CONTRO

VI SI B L E AN D/ OR IN VI SI B L

L A SER RA DI AT IO N W H EN OP EN

MCL PO WE

7 2 7 2 0 0 8 Acb d

M a n u fa c tu re d :DATE b y :COUL TER CORPORATION1 1 8 0 0 S.W . 1 4 7 AVEM IAM I, F L 3 3 1 9 6 -2 5 0 0

TH IS L ASER PRODUCT CONF ORM STO TH E PROVISIONS OF 2 1 CF R.SUB CH APTER J , SECTIONS 1 0 4 0 .1 0AND 1 0 4 0 .1 1 .

VISIB L E AND/OR INVISIB L E

L ASER RADIATION W H EN OPEN

AVOID EYE OR SKIN

EXPOSURE TO DIRECT OR

SCATTERED RADIATION

FI BE

RAN

RE

SC OP E

SCOPE

FLOWCEL

WAST

WAST PRESSURE VAC UUM

LOGIC ANALOG OPTI

M anu fa ct ur ed

D A T E b y CO U L T E R CO R P O R AT IO

1 1 800 S . W . 1 4 7 AV E

M I AM I, FL 33 1 96- 250

T H IS L AS E R PR O D U C T CO NF O R M S T O T H E PR O V IS IO NS O F 21 CF R .

S U BC H A PT E R J, S E CT IO NS 1 0 40 .1 AN D 040. 1 1 .

POWER MO DUL

CONTRO

VI SI B L E AN D/ OR IN VI SI B L

L A SER RA DI AT IO N W H EN OP EN

AV OI D EY E OR SK IN

EX POS URE TO DI RE CT OR

SC AT TE RE D RA DI AT IO

MCL PO WE

b

c

b L ab el is ap p lied only w h en an op tional s econd las er is ins talled .

c T h is cover is only p res ent w h en ins trument contains an op tional H eNe las er.

Page 124: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-8

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S

Fig ure 6.10 La ser La b els on th e MCL Prob e Housing Cov er

CA U TIONL ASER L IG H T DO NOT STARE INTO B EAM

6 7 0 n m DIODE L ASER1 .0 M IL L IW ATT M AXIM UM CL ASS II L ASER PRODUCT

CA U TIONLa s e r r a d ia tio n w h e n o p e n

a n d in te r lo c k d e fe a te d .

D O N OT STA RE IN TO B EA M.

CLA SS 1 LA SER PROD U CT

A V OID EX POSU RE

VISIB L E AND/OR INVISIB L EL ASER RADIATION IS EM ITTED

F ROM TH IS APERTURE.

5 5 7 0 0 0 2 B

Page 125: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-9

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S 6

Fig ure 6.11 La ser La b els on th e MCL Ba r-Cod e Rea d er

7 27 2001 A

AVOID EX POSURE LASER LIGHT IS EMITTEDFROM THIS APERTURE

CAUTION LASER LIGHT WHEN OPEN-DO NOT STARE INTO BEAM.PRODUCT CONFORMS TO USA DHHS 21 CFR SUBCHAPTER "J "

CAUTION VORSICHTL AS E R L IG H T D O NO T S T AR E INT O BE AM

67 0 nm L AS E R D IO D E1 .0 M IL L IW AT T M AX

CL AS S II L AS E R PR O D U CT

AVOID EXPOSURE

LASER LIGHT IS

EMIT

TED

FROM THIS

APERTURE

CAUTION LASER LIG

HT WHEN O

PEN-DO N

OT STARE IN

TO BEAM

.

PRODUCT CONFORM

S TO USA D

HHS 21 CFR S

UBCHAPTER "J"

CAUTION

VORSICHT

SER

IAL

NU

MBE

R/M

OD

EL N

UM

BER

MAN

UFA

CTU

RED

MIC

RO

SCAN

FIS

CG

D/R

DR

DY

PWR

US

UL

SERIAL NUMBER/MODEL NUMBER

MANUFACTURED

MICROSCAN

FIS

CGD/RD RDY PWR

USUL

Page 126: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-1 0

TROUBLESHOOTINGP R ECA U TIONS/H A Z A R D S

Wa rning La b els on UPS

T h e la b e l lo c a te d ne a r th e c irc u it b r e a k e r s o n th e U niv e r s a l P o w e r S u p p ly ins tr u c ts th e u s e r to r e fe r to p r o du c t do c u m e nta tio n b e fo r e r e s e tting th e c irc u it b r e a k e r s .

T h e la b e l lo c a te d ne x t to th e p o w e r s w itc h o n th e U niv e r s a l P o w e r S u p p ly ins tr u c ts th e u s e r to r e fe r to p r o du c t do c u m e nta tio n b e fo r e p o w e r ing u p th e ins tr u m e nt.

Fig ure 6.12 Interna tiona l Wa rning Sy m b ol Loca tions

SYSTEM POWER

MCL POWER

WATER TRAP

VAC TRAP

AIR FILTER

V A C

F ILTER

SY S VAC

SY S PRESS

30 PSI

PRESSADJ

SYSTEM POWER

MCL POWER

WATERTRAP

VAC TRAP

AIR FILTER

V A C

F ILTER

SY S VAC

SY S PRESS

30PSI

PRESSADJ

Page 127: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-1 1

TROUBLESHOOTINGM A INTENA NCE SCH ED U L ES 6

Disp osa l Preca ution

6.2 MAINTENANCE SCHEDULES

Clea ning Sch ed ule

S e e T a b le 6.1 fo r th e c le a ning s c h e du le .

Rep la cem ent Sch ed ule

T h e s h e a th flu id filte r ne e ds to b e r e p la c e d e v e r y 6 m o nth s . A ll o th e r r e p la c e m e nt a nd a dju s tm e nt p r o c e du r e s s h o u ld b e do ne o n a n a s ne e de d b a s is .

6.3 ERROR MESSAGESS e e T a b le 6.2 fo r a lis t o f a ll o f th e e r r o r m e s s a g e s .

Disp la y Loca tions

E r r o r m e s s a g e s c a n a p p e a r a t th e b o tto m o f th e CX P s o ftw a r e s c r e e n, in th e Cy to m e te r S ta tu s Me s s a g e s s c r e e n, a nd in th e c y to m e te r.lo g file .

CX P Softw a re Screen

A t th e b o tto m o f th e CX P s o ftw a r e s c r e e n, th e la s t e r r o r m e s s a g e a p p e a r s . S e e F ig u r e 6.13.

N ote: I f m u ltip le e r r o r m e s s a g e s a r e p o s te d a t th e s a m e tim e , o nly th e la s t o ne p o s te d a p p e a r s h e r e . A ll o f th e e r r o r m e s s a g e s p o s te d a p p e a r in th e Cy to m e te r S ta tu s Me s s a g e s s c r e e n a nd th e c y to m e te r.lo g file .

WARNING R is k of b ioh az ard ous contamination if y ou h ave s kin contact w ith th e w as te container, its contents , and its as s ociated tub ing . T h e w as te container and its as s ociated tub ing mig h t contain res id ual b iolog ical material and mus t b e h and led w ith care. Clean up s p ills immed iately . D is p os e of th e contents of th e w as te container in accord ance w ith y our local reg ulations and accep tab le lab oratory p roced ures

Ta b le 6.1 Clea ning Sch ed ule

Com p onent Da ily Week ly Month ly Ev ery 60 Da y s As Need ed

CL E AN T H E AIR FIL T E R S - c - - -

CL E AN T H E CL E ANING AG E NT CO NT AINE R

- - - c -

CL E AN T H E M CL S AM PL E H E AD AND T H E S AM PL E PR O BE

c c - - -

CL E AN T H E S AM PL ING S Y S T E M c - - - -

CL E AN T H E S H E AT H FL U ID CO NT AINE R

- - c - -

CL E AN T H E V ACU U M T R AP - - - - c

- = Not Ap p licab le

Page 128: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-1 2

TROUBLESHOOTINGER R OR M ESSA G ES

Fig ure 6.13 Error Messa g e on CX P Softw a re Screen, Ex a m p le

Cy tom eter Sta tus Messa g es Screen

In th e Cy to m e te r S ta tu s Me s s a g e s s c r e e n, th e la s t e r r o r m e s s a g e a nd a ll u nc le a r e d e r r o r m e s s a g e s a p p e a r. S e e F ig u r e 6.14.

r T o a c c e s s th e Cy to m e te r S ta tu s Me s s a g e s s c r e e n, do u b le c lic k th e e r r o r m e s s a g e a t th e b o tto m o f th e CX P s o ftw a r e s c r e e n.

r Clea r Sta tus w h e n y o u w a nt to de le te a ll m e s s a g e s in th e Cy to m e te r S ta tu s Me s s a g e s s c r e e n.

Fig ure 6.14 Cy tom eter Sta tus Messa g es Wind ow , Ex a m p le

Cy tom eter.log File

In th e c y to m e te r.lo g file , a ll m e s s a g e s a p p e a r fr o m th e la s t 30 da y s u nle s s th e y w e r e m a nu a lly c le a r e d. R e fe r to E R R O R ME S S A G E CY T O ME T E R .LO G F ILE fo r de ta ils . S e e F ig u r e 6.15.

Page 129: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-1 3

TROUBLESHOOTINGER R OR M ESSA G E CY TOM ETER .L OG F IL E 6

Fig ure 6.15 Ex a m p le of Error Messa g es in Cy tom eter.log File

6.4 ERROR MESSAGE CY TOMETER.LOG FILET h e Cy to m e te r e r r o r m e s s a g e s a r e lo c a te d in th e c y to m e te r.lo g file .

N ote: E r r o r m e s s a g e s o v e r 30 da y s o ld a r e a u to m a tic a lly r e m o v e d fr o m th e c y to m e te r.lo g file a nd p la c e d into th e c y to m e te r a rc h iv e .lo g file .

How to Access th e Cy tom eter.log File

From CX P Softw a re

r P r e s s Ý+L. S e e F ig u r e 6.15.

O R ,

r Cy tom eter tt Cy tom eter Log tt View Log . S e e F ig u r e 6.15.

From Wind ow s Desk top

1. Sta rt tt Prog ra m s tt Accessories tt Wind ow s Ex p lorer tt My Com p uter tt (C:) d riv e tt CX P.

2. Hig h lig h t cy tom eter.log .

3. D o u b le c lic k o n cy tom eter.log to o p e n. S e e F ig u r e 6.15.

Page 130: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-1 4

TROUBLESHOOTINGER R OR M ESSA G E CY TOM ETER .L OG F IL E

Cy tom eter.Log Entry Descrip tion

A ll c y to m e te r.lo g e r r o r m e s s a g e e ntr ie s a r e p o s te d in c h r o no lo g ic a l o rde r. E a c h e r r o r m e s s a g e e ntr y c o ns is ts o f fo u r line s ( s e e F ig u r e 6.15) :

r D a te a nd tim e w h e n th e e r r o r m e s s a g e o c c u r r e d

r 18 -dig it nu m b e r - fo r S e r v ic e u s e o nly

r F o u r-dig it nu m b e r - fo r S e r v ic e u s e o nly

r E r r o r m e s s a g e te x t. S e e T a b le 6.2 fo r a lis t o f m e s s a g e s a nd o p e r a to r a c tio ns .

How to Sea rch th e Cy tom eter.log File

T o s e a rc h fo r a s p e c ific w o rd o r p h r a s e lis te d a ny w h e r e in th e c y to m e te r.lo g file :

1. Ed it tt Find ...

2. T y p e in th e w o rd o r p h r a s e y o u w a nt to find ( E x a m p le : Waste) .

3. T h e dir e c tio n o f th e s e a rc h : U p o r D o w n.

4. Find Nex t a nd th e ne x t o c c u r r e nc e o f th e w o rd in th e e r r o r lo g is h ig h lig h te d.

5. R e p e a t s te p 4 a s ne e de d o r u ntil C annot find “ X X X X X ” a p p e a r s .

Oth er Functions Av a ila b le

He re a r e s o m e o f th e m o r e o fte n u s e d fu nc tio ns a v a ila b le fr o m th e c y to m e te r.lo g file p u ll do w n m e nu s : File, Ed it, Form a t, a nd Help :

Print

T o p r int th e c y to m e te r.lo g file : File tt Print.

Ch a ng e Font

T o c h a ng e th e fo nt: Form a t tt Font, a nd s e le c t th e ne w fo nt.

Find Help Top ics

T o find He lp o n o th e r to p ic s : Help tt Help Top ics.

Cy tom etera rch iv e.log File

Th e c y to m e te r a rc h iv e .lo g file c o nta ins e r r o r m e s s a g e s th a t w e r e a u to m a tic a lly m o v e d fr o m th e c y to m e te r.lo g file a fte r 30 da y s . T h is lo g is fo r S e r v ic e u s e .

Page 131: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-1 5

TROUBLESHOOTINGER R OR M ESSA G ES TA B L E 6

6.5 ERROR MESSAGES TABLET a b le 6.2 lis ts th e e r r o r m e s s a g e s in a lp h a b e tic a l o rde r, w ith th e ir c a u s e a nd w h a t to do a b o u t th e m . T h e s e a r e th e e r r o r m e s s a g e s p r o du c e d b y th e Cy to m e te r.

Ca ll y o u r B e c k m a n Co u lte r R e p r e s e nta tiv e if:

r T h e r e c o m m e nde d a c tio n do e s no t s o lv e th e p r o b le m .

r Y o u ne e d h e lp .

Ta b le 6.2 Error Messa g es

Messa g e Ca use Action

Cle a n s e L e v e l Er ro r L ow cleaning ag ent. Fill cleaning ag ent container. R efer to FIL L T H E CL E ANING AG E NT CO NT AINE R .

Cleans e s ens or failed if th e cleaning ag ent container is full b ut th is error mes s ag e d is p lay ed .

Call y our Beckman Coulter R ep res entative.

Cle a n s e L e v e l W a r n in g L ow cleaning ag ent. Fill cleaning ag ent container. R efer to FIL L T H E CL E ANING AG E NT CO NT AINE R .

Cleans e s ens or failed if th e cleaning ag ent container is full b ut th is error mes s ag e d is p lay ed .

Call y our Beckman Coulter R ep res entative.

D a ta R a te W a r n in g T h e d is criminated d ata rate exceed ed 6,000 cells p er s econd .

1 . D ilute th e s amp le or ch ang e th e d is criminator s etting .

2. Ch eck th at th e s h eath fluid container cap is tig h tened .

3. If p rob lem continues , R E PL ACE T H E S H E AT H FL U ID FIL T E R .

D a ta Str e a m W a r n in g D ata acq uis ition h ard w are error 1 . R eb oot th e comp uter and res tart th e Cy tometer.

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

H o s t Co m m a n d In v a lid T h e Cy tometer s oftw are could not p roces s th e req ues ted command from th e W orks tation.

1 . R eb oot th e comp uter and res tart th e Cy tometer.

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

L a s e r Cu r r e n t Er ro r T h e amount of current req uired b y th e las er is outs id e th e exp ected rang e.

Call y our Beckman Coulter R ep res entative.

L a s e r P o w e r Er ro r T h e amount of las er lig h t p ow er is outs id e th e ins trument’s op erating rang e.

Call y our Beckman Coulter R ep res entative.

L a s e r R e g u la tio n W a r n in g T h e las er lig h t p ow er is fluctuating . Call y our Beckman Coulter R ep res entative.

L a s e r Sta rt Er r o r T h e las er failed to s tart w ith in 1 20 s econd s .

1 . Pow er th e ins trument off th en on.

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

Page 132: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-1 6

TROUBLESHOOTINGER R OR M ESSA G ES TA B L E

M CL Ca r o u s e l In /Ou t Er r o r M CL carous el d id not move w h en req ues ted to d o s o.

1 . Ch eck th at th ere is no ob vious ob s truction (s amp le tub e) in th e M CL area.

2. Ch eck th at th e 30 p s i g ag e on th e p ow er s up p ly is okay .

3. If no ob s truction is found , call y our Beckman Coulter R ep res entative.

M CL Ca r o u s e l L a b e l Er r o r M CL carous el d id not read carous el b ar-cod e lab el.

1 . Ch eck th at th e b ar-cod e lab el is not torn or w ritten on.

2. T ry us ing anoth er carous el.

3. If p rob lem continues , call y our Beckman Coulter R ep res entative.

M CL Ca r o u s e l R o ta te Err o r M CL carous el d id not rotate correctly

Ch eck th at th ere is no ob vious ob s truction (s amp le tub e) in th e M CL area.

If no ob s truction is found , call y our Beckman Coulter R ep res entative.

M CL CP U Err o r M CL h ard w are error. Call y our Beckman Coulter R ep res entative.

M CL D o o r Op e n Er r o r M CL cover is op en w h ile th e M CL is in us e.

Clos e th e M CL cover.

M CL D o o r Op e n W a r n in g M CL cover is op en w h ile th e M CL is in us e.

Clos e th e M CL cover.

M CL EP R OM Err o r M CL h ard w are error. Call y our Beckman Coulter R ep res entative.

M CL Er r o r M CL h ard w are error. Call y our Beckman Coulter R ep res entative.

M CL In te rlo c k Er ro r T h e M CL Interlock is op en w h ile th e M CL is in us e.

Call y our Beckman Coulter R ep res entative.

M CL P a r a lle l R e c v Er r o r An M CL communications error. Call y our Beckman Coulter R ep res entative.

M CL P a r a lle l Se n d Er ro r An M CL communications error. Call y our Beckman Coulter R ep res entative.

M CL P r o b e U p /D o w n Err o r S h ort circuit. Ch eck if a circuit b reaker ind icator is d ark. S ee R E S E T T H E CIR CU IT BR E AK E R S .

M CL s amp le p rob e d id not move w h en req ues ted to d o s o.

Call y our Beckman Coulter R ep res entative.

M CL P r o g r a m L o a d Err o r An M CL h ard w are error. Call y our Beckman Coulter R ep res entative.

M CL R A M Er r o r An M CL h ard w are error. Call y our Beckman Coulter R ep res entative.

M CL R e c fr o m F a u lt Er r o r An M CL communications error. Call y our Beckman Coulter R ep res entative.

M CL R e c e iv e Tim e o u t Er r o r An M CL communication error. Call y our Beckman Coulter R ep res entative.

M CL R e q u e s t Er r o r Communication error b etw een th e Cy tometer and th e M CL .

1 . Pow er th e ins trument off th en on.

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

M CL Se r ia l 1 R e c v Er r o r An M CL communications error. Call y our Beckman Coulter R ep res entative.

M CL Se r ia l 1 Se n d Er ro r An M CL communications error. Call y our Beckman Coulter R ep res entative.

Ta b le 6.2 Error Messa g es (Continued)

Messa g e Ca use Action

Page 133: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-1 7

TROUBLESHOOTINGER R OR M ESSA G ES TA B L E 6

M CL Se r ia l 2 R e c v Er r o r An M CL communications error. Call y our Beckman Coulter R ep res entative.

M CL Se r ia l 2 Se n d Er ro r An M CL communications error. Call y our Beckman Coulter R ep res entative.

M CL Tr a n s m it Tim e o u t Er r o r An M CL communication error. Call y our Beckman Coulter R ep res entative.

M CL Tu b e D is p la c e d Er ro r A tub e is p os itioned incorrectly in th e M CL .

Call y our Beckman Coulter R ep res entative.

M CL Tu b e J a m Er r o r A tub e is s tuck in th e M CL . Call y our Beckman Coulter R ep res entative.

M CL Tu b e L o a d Err o r T h ere is a b ad s eal b etw een th e M CL s amp le p rob e g uid e and s amp le tub e.

Put s amp le into anoth er tub e.

M CL Tu b e P o s itio n Er r o r T h e M CL d id not rotate to th e correct tub e p os ition or th ere w as an error read ing th e p os ition b ar cod e on th e carous el.

Call y our Beckman Coulter R ep res entative.

M CL Tu b e U p /D o w n Er r o r U nab le to load or unload th e s amp le tub e from th e M CL s amp ling p os ition.

1 . Ch eck th at th e lab els on th e s amp le tub es are s ecure and are not ad h ering to th e w alls of th e carous el.

2. Ch eck th at th ere is no crack in th e s amp le tub e.

3. If p rob lem continues , call y our Beckman Coulter R ep res entative.

Sa m p le P r e s s u r e Er ro r T h ere may b e a leak caus ed b y a b ad s amp le tub e or a b ad s amp le h ead .

Ins p ect s amp le tub e and s amp le h ead for d amag e. Ch ang e as req uired . S ee R E PL ACE T H E M CL S AM PL E H E AD .

Bad reg ulator or tub ing . Call y our Beckman Coulter R ep res entative.

Se n s o rs Stre a m W a r n in g T h ere w as an error in th e communication of th e ins trument op erating d ata p acket from th e acq uis ition h ard w are to th e Cy tometer s oftw are.

1 . R eb oot th e comp uter and res tart th e Cy tometer.

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

Sh e a th D r a w e r Er ro r T h e s h eath fluid (reag ent) d raw er is op en.

Clos e th e reag ent d raw er comp letely .

Sh e a th L e v e l Er r o r T h ere is not enoug h s h eath fluid for furth er s amp le analy s is .

Fill s h eath fluid container. S ee FIL L T H E S H E AT H FL U ID CO NT AINE R .

Sh e a th L e v e l W a r n in g T h e firs t time th is mes s ag e is d is p lay ed , th ere is enoug h s h eath fluid for ab out 5 minutes of s amp le analy s is .

Fill th e s h eath fluid container. S ee FIL L T H E S H E AT H FL U ID CO NT AINE R .

If th e s h eath fluid container is full, th e s h eath fluid s ens or failed .

Call y our Beckman Coulter R ep res entative.

Ta b le 6.2 Error Messa g es (Continued)

Messa g e Ca use Action

Page 134: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-1 8

TROUBLESHOOTINGER R OR M ESSA G ES TA B L E

Sh e a th P r e s s u r e Er r o r T h e s h eath fluid p res s ure is outs id e th e s y s tem’s op erating rang e.

1 . Ch eck s h eath fluid and cleaning ag ent container cap s for tig h tnes s .

2. If p rob lems continues , call y our Beckman Coulter R ep res entative.

3. If p rob lem continues , R E PL ACE T H E S H E AT H FL U ID FIL T E R .

Sta te M a c h in e F a ilu r e Cy tometer s oftw are failure. 1 . Pow er th e ins trument off th en on.

2. If p rob lems continues , call y our Beckman Coulter R ep res entative.

Sy s te m P r e s s u r e Er ro r Pres s ure line is not connected b etw een th e p ow er mod ule and th e Cy tometer.

Connect th e p res s ure line.

T h e p res s uriz ed air s up p ly is outs id e th e s y s tem’s op erating rang e.

1 . G o to th e R ead y S tate, th en ch eck th at th e s y s tem p res s ure is 30 p s i.

2. R un a s amp le and monitor th e s y s tem p res s ure. If th e s y s tem p res s ure d rop s b elow th e rang e s p ecified in th e ins trument manual, th en call y our Beckman Coulter R ep res entative.

S h ort circuit. Ch eck if a circuit b reaker ind icator is d ark. S ee R E S E T T H E CIR CU IT BR E AK E R S .

Sy s te m Va c u u m Er r o r L iq uid in th e vacuum trap . Ch eck th at th e vacuum trap (on th e front of th e Pow er S up p ly ) is tig h t and is les s th an 1 /4 full of fluid . If it is more full, emp ty it (s ee CL E AN T H E V ACU U M T R AP).

V acuum line is not connected b etw een th e p ow er mod ule and th e Cy tometer.

Connect th e vacuum line at th e b ack of th e ins trument.

H ard w are p rob lem. Call y our Beckman Coulter R ep res entative.

Te m p e r a tu r e Err o r T emp erature ins id e th e Cy tometer is ab ove 60° C.

1 . Clean y our air filters . S ee CL E AN T H E AIR FIL T E R S .

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

Te m p e r a tu r e Se n s o r F a ilu r e T emp erature s ens or failure. Call y our Beckman Coulter R ep res entative.

Te m p e r a tu r e W a r n in g T emp erature ins id e Cy tometer is ab ove 50° C.

1 . Clean y our air filters . S ee CL E AN T H E AIR FIL T E R S .

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

Tra n s p u te r 1 Er r o r Cy tometer s oftw are error. At th e W orks tation turn th e s y s tem off, and th en turn it b ack on.

Tra n s p u te r 2 Er r o r Cy tometer s oftw are error. At th e W orks tation turn th e s y s tem off, and th en turn it b ack on.

Ta b le 6.2 Error Messa g es (Continued)

Messa g e Ca use Action

Page 135: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-1 9

TROUBLESHOOTINGER R OR M ESSA G ES TA B L E 6

Tra n s p u te r L in k Er r o r A Cy tometer comp uter communications error.

Call y our Beckman Coulter R ep res entative.

Tra n s p u te r L in k W a r n in g A Cy tometer comp uter communications error.

Call y our Beckman Coulter R ep res entative.

U n k n o w n Str e a m W a r n in g An unid entified d ata p acket communication error occurred b etw een th e acq uis ition h ard w are and th e Cy tometer s oftw are.

1 . R ecord an entry in th e Action L og S h eet.

2. R eb oot th e comp uter and res tart th e Cy tometer.

3. If p rob lem continues , call y our Beckman Coulter R ep res entative.

Va c u u m Ch a m b e r W a r n in g T h e liq uid level in th e vacuum ch amb er is too h ig h .

1 . Ch eck th at th e vacuum trap (on th e front of th e Pow er S up p ly ) is tig h t and is les s th an 1 /4 full of fluid . If it is more full, emp ty it (s ee CL E AN T H E V ACU U M T R AP).

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

W a s te B a c k p r e s s u r e Er r o r T h e filter on th e w as te container vent line is p rob ab ly w et, clog g ed , or d is connected .

1 . Ch eck th e w as te vent filter for th e p res ence of liq uid and a p rop er connection.

2. If p rob lem continues , call y our Beckman Coulter R ep res entative.

W a s te L e v e l Er r o r T h ere is not enoug h emp ty volume in th e w as te container for furth er s amp le analy s is .

E mp ty th e w as te container. S ee E M PT Y T H E W AS T E CO NT AINE R .

W a s te L e v e l W a r n in g T h ere is enoug h emp ty volume in th e w as te container for ab out 5 minutes of s amp le analy s is .

E mp ty th e w as te container. S ee E M PT Y T H E W AS T E CO NT AINE R .

If th e w as te container is not full, th e w as te s ens or failed .

Call y our Beckman Coulter R ep res entative.

Ta b le 6.2 Error Messa g es (Continued)

Messa g e Ca use Action

Page 136: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-20

TROUBLESHOOTINGL EVEL SENSE IND ICA TOR S

6.6 LEVEL SENSE INDICATORS

Sh ea th Low

W h e n th e Sh ea th Low indic a to r ( s e e F ig u r e 6.16) a p p e a r s :

r D u r ing s a m p le a na ly s is , y o u h a v e 5 m inu te s to finis h a na ly z ing th e c u r r e nt s a m p le .

r Y o u c a nno t a na ly z e s a m p le s o r u s e th e ins tr u m e nt u ntil th e s h e a th flu id c o nta ine r is fille d.

r F ILL T HE S HE A T H F LU ID CO N T A IN E R .

Fig ure 6.16 Sh ea th Low Ind ica tors

Wa ste Full

W h e n th e Wa ste Full indic a to r ( s e e F ig u r e 6.17 ) a p p e a r s :

r D u r ing s a m p le a na ly s is , y o u h a v e 5 m inu te s to finis h a na ly z ing th e c u r r e nt s a m p le .

r Y o u c a nno t a na ly z e s a m p le s o r u s e th e ins tr u m e nt u ntil th e w a s te c o nta ine r is e m p tie d.

r E MP T Y T HE W A S T E CO N T A I N E R .

Fig ure 6.17 Wa ste Full Ind ica tors

6.7 CY TOMETER CONTROL WINDOW CANNOT BE VIEWEDIf th e Cy to m e te r Co ntr o l w indo w c a nno t b e v ie w e d ( it is h idde n b e h ind th e W indo w s T a s k b a r a t th e b o tto m o f th e s c r e e n) , th e A u to h ide fe a tu r e is c u r r e ntly s e le c te d. Ch a ng e th e W indo w s s e tting s to de s e le c t th e A u to h ide fe a tu r e a nd k e e p th e Cy to m e te r Co ntr o l w indo w in v ie w .

T o de s e le c t th e A u to h ide fe a tu r e :

b

b

Page 137: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B 6-21

TROUBLESHOOTINGCY TOM ETER CONTR OL W IND OW CA NNOT B E VIEW ED 6

1 Sta rt tt Setting s tt Ta sk b a r & Sta rt

Menu....

2 O n th e Genera l ta b , Auto h id e

a nd de s e le c t Alw a y s on top .

.

3 T h e Cy to m e te r Co ntr o l w indo w s h o u ld

no w b e p a r tia lly in v ie w .

4 D r a g th e Cy to m e te r Co ntr o l w indo w

into fu ll v ie w .

Page 138: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B6-22

TROUBLESHOOTINGCY TOM ETER CONTR OL W IND OW CA NNOT B E VIEW ED

Page 139: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B A-1

AAHOW TO...

A.1 SOFTWARE PROCEDURESF o r O nline h e lp , c lic k o n th e link s b e lo w to g o to th e de ta ile d p r o c e du r e .

Th ese p roced ures a re in th e Sy stem Ov erv iew ch a p ter in th e Instructions For Use Ma nua l.

r CR E A T IN G P R O T O CO LS

r CR E A T IN G R E G I O N S

r CR E A T IN G G A T E S

r CR E A T IN G F LO W P A G E S

r CR E A T IN G P A N E LS

r CR E A T IN G W O R K LIS T S

Th ese p roced ures a re in th e Qua lity Control ch a p ter in th e Instructions For Use Ma nua l.

r A u to S e tu p I I W iz a rd

r A p p lic a tio n D e finitio n W iz a rd ( de fine a ll y o u r a p p lic a tio ns )

r A u to S e tu p S c h e du le r ( m u ltip le a p p lic a tio n A u to S e tu p )

Th ese p roced ures a re in th e Using CX P Softw a re ch a p ter in th e Reference Ma nua l.

r B a tc h A u to MA T O R

r O v e r la y His to g r a m P lo ts

r A dv a nc e d Co lo r P r e c e de nc e

r Lis tm o de Co m p e ns a tio n

r S e tting a CA L R e g io n

A.2 HARDWARE PROCEDURESF o r O nline h e lp , c lic k o n th e link s b e lo w to :

r V ie w a s h o r t v ide o o f th e p r o c e du r e o r

r G o to th e de ta ile d p r o c e du r e .

Th ese p roced ures a re in th e Sp ecia l Proced ures Ma nua l.

r O p e n/r e m o v e th e ins tr u m e nt c o v e r s - v ide o o r p r o c e du r e .

r Cle a n th e MCL s a m p le h e a d a nd th e s a m p le p r o b e - v ide o o r p r o c e du r e .

r R e p la c e th e s a m p le p r o b e a nd s a m p le p ic k u p tu b ing - v ide o o r p r o c e du r e .

r R e p la c e th e MCL s a m p le h e a d - v ide o o r p r o c e du r e

r R e p la c e th e o p tic a l filte r p la te - v ide o o r p r o c e du r e .

r R e p la c e a filte r in th e o p tic a l filte r p la te - v ide o o r p r o c e du r e

Page 140: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B A-2

HOW TO...H A R D W A R E P R OCED U R ES

Page 141: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B B-1

BBBAR-CODE SPECIFICATIONS

B.1 BAR-CODE SAMPLE IDENTIFICATIONB a r-c o de s y m b o ls a r e a h ig h ly a c c u r a te a nd e ffic ie nt p r o c e du r e fo r ide ntify ing a nd p r o c e s s ing la b o r a to r y s a m p le s . B e c k m a n Co u lte r ins tr u m e nts u s e fo u r b a r-c o de s y m b o lo g ie s ( ty p e s ) to ide ntify s p e c im e ns :

r Co de 128

r Co de 39®

r Co da b a r

r Inte r le a v e d 2-o f-5.

T h e b a r- c o de r e a de r s e ns e s th e diffe r e nc e b e tw e e n e na b le d b a r-c o de s y m b o lo g ie s in a r u n.

Fig ure B.1 Ba r-Cod e La b el

B.2 CORRECT PLACEMENT OF THE BAR-CODE LABELT h e b a r- c o de la b e l m u s t b e p la c e d a m inim u m o f 25.4 m m ( 1.0 in.) fr o m th e b o tto m o f th e tu b e . R e fe r to F ig u r e B .2.

IMPORTANT A mis read lab el can caus e one s amp le ID to b e read as anoth er s amp le ID . T h e lab oratory ’s p roces s for p rinting , p lacing , and meeting all b ar-cod e s p ecifications is imp ortant to ach ieve h ig h ly accurate read ing . Follow th e b ar-cod e s p ecifications to avoid inaccurate read ing of th e b ar-cod e lab el.

b Q u ie t z o ne

c B a r- c o de s y m b o l

d S a m p le I D

AB C1 2 3 4 5 6 7 8 9

b

c

d

0231001A

Page 142: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BB-2

BAR-CODE SPECIFICATIONSB A R -COD E L A B EL SP ECIF ICA TIONS

Fig ure B.2 Ba r-Cod e La b el Pla cem ent

P u t la b e ls o n th e tu b e s s o th a t th e b a r s fo llo w o ne a no th e r in a v e r tic a l s e q u e nc e . R e fe r to F ig u r e B .2. T h e b a r-c o de r e a de r s c a ns th e tu b e v e r tic a lly . D o no t tilt th e la b e l m o r e th a n ± 7 .5 de g r e e s fr o m th e a x is o f th e tu b e .

P u t th e tu b e s in th e c a r o u s e l s o th a t th e b a r- c o de s y m b o ls a r e v is ib le th r o u g h th e s lo ts in th e fr o nt o f th e c a r o u s e l. W h e n v ie w e d a t e y e le v e l, th e fu ll s y m b o l, inc lu ding th e q u ie t z o ne s , m u s t b e v is ib le th r o u g h th e s lo t a nd a b o v e th e b o tto m o f th e c a r o u s e l.

N ote: T h e F C 50 0 r o ta te s th e tu b e a s ne e de d s o th e b a r-c o de la b e l c a n b e r e a d.

B.3 BAR-CODE LABEL SPECIFICATIONS

T h e q u a lity o f th e b a r- c o de s y m b o l a nd th e la b e l is im p o r ta nt fo r a c c u r a te r e a ding . F o r h ig h a c c u r a c y , u s e la b e ls th a t m e e t a ll o f th e s p e c ific a tio ns .

W h e n p o s s ib le , p r int th e s a m p le I D o n th e la b e l in a lp h a nu m e r ic c h a r a c te r s s o th e o p e r a to r c a n m a nu a lly e nte r th e b a r- c o de info r m a tio n if th e b a r-c o de s y m b o l c a nno t b e r e a d.

La b el Siz e a nd Th ick ness

T h e le ng th o f th e la b e l m u s t b e le s s th a n 44.45 m m ( 1.7 5 in.) . T h e la b e l inc lu de s th e b a r- c o de s y m b o l a nd a m inim u m q u ie t z o ne o f 3.5 m m ( 0 .14 in.) a t e a c h e nd o f th e s y m b o l. R e fe r to F ig u r e B .3.

b 25.4 m m ( 1.0 in.) m inim u m

c 7 .5 de g r e e s

b

c

c

IMPORTANT A mis read lab el can caus e one s amp le ID to b e read as anoth er s amp le ID . T h e lab oratory ’s p roces s for p rinting , p lacing , and meeting all b ar-cod e s p ecifications is imp ortant to ach ieve h ig h ly accurate read ing . Follow th e b ar-cod e lab el s p ecifications to keep th e rate of mis read lab els to a minimum.

Page 143: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B B-3

BAR-CODE SPECIFICATIONSB A R -COD E L A B EL SP ECIF ICA TIONS B

Fig ure B.3 Ba r-Cod e La b el Sp ecifica tions

T h e w idth o f th e b a r- c o de la b e l m u s t b e 5 m m ( 0 .2 in.) le s s th a n th e c irc u m fe r e nc e o f th e s a m p le tu b e .

La b e l th ic k ne s s , inc lu ding a dh e s iv e , m u s t b e 0 .0 9 m m ( 0 .0 0 36 in.) m a x im u m . T o ta l th ic k ne s s fo r a ll la b e ls a nd a dh e s iv e s p u t to g e th e r m u s t b e 0 .36 m m ( 0 .0 144 in.) m a x im u m .

Sy m b ol Dim ensions

T h e h e ig h t o f th e b a r- c o de s y m b o l m u s t b e 19.0 5 m m ( 0 .7 5 in.) m inim u m .

S e e T a b le B .2.

La b el a nd Print Qua lity

A ll b a r- c o de s y m b o ls m u s t a g r e e w ith th e A m e r ic a n Ide ntific a tio n Ma nu fa c tu r e r ’s ( A IM)

U nifo r m S y m b o lo g y S p e c ific a tio n.1

A ll b a r- c o de s y m b o ls m u s t b e p r inte d a t p r int q u a lity c la s s “ B ” o r b e tte r a s de fine d b y th e

A m e r ic a n N a tio na l S ta nda rds Ins titu te ( A N S I) .2 S e v e r a l fa c to r s a ffe c t p r int q u a lity :

r La b e ls m u s t b e c le a n, no t y e llo w e d, a nd u s e d b e fo r e th e e x p ir a tio n da te .

r P r int th e b a r- c o de s y m b o l o n m a te r ia l th a t is r e fle c tiv e a nd h a s a m a tte finis h . U s e a b a c k g r o u nd diffu s e r e fle c ta nc e o f 8 0 % o r m o r e fo r m a x im u m c o ntr a s t.

r T h e la b e ls m u s t no t h a v e de fe c ts s u c h a s s p o ts , line s , m is s ing s e c tio ns , c u ts , fo lds , o r de ns ity p r o b le m s .

r T h e b a r s in th e b a r- c o de s y m b o l m u s t b e w e ll-de fine d. E dg e s m u s t b e c o ns ta nt ( no t ir r e g u la r ) , s o th e b a r s a nd s p a c e s h a v e th e c o r r e c t w idth s fo r th e b a r- c o de s y m b o lo g y u s e d.

b Q u ie t z o ne s 3.5 m m ( 0 .14 in.) m inim u m

c B a r- c o de s y m b o l h e ig h t 19.0 5 m m ( 0 .7 5 in.) m inim u m

d B a r- c o de la b e l le ng th 44.45 m m ( 1.7 5 in.) m a x im u m

AB C1 2 3 4 5 6 7 8 9

b b

c

d0231002A

Page 144: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BB-4

BAR-CODE SPECIFICATIONSB A R -COD E ER R OR R A TE

B.4 BAR-CODE ERROR RATE

T h e q u a lity o f th e b a r-c o de s y m b o l a nd th e la b e l is im p o r ta nt fo r a c c u r a te r e a ding . T o g e t th e h ig h e s t p o s s ib le a c c u r a c y o nly u s e la b e ls th a t m e e t a ll th e s p e c ific a tio ns de s c r ib e d fo r la b e ls a nd s y m b o ls . D e v ia tio ns fr o m th e s e s p e c ific a tio ns m a k e th e b a r c o de m o r e diffic u lt to r e a d a nd a llo w fo r a p o s s ib le inc r e a s e in th e e r r o r r a te .

T h e s y m b o lo g y a nd th e c o nfig u r a b le p a r a m e te r s th a t th e la b o r a to r y s e le c ts h a v e a n e ffe c t o n th e e r r o r r a te . Ce r ta in fe a tu r e s o f th e s y m b o lo g ie s a nd th e s e le c tio ns m a de b y th e la b o r a to r y h a v e a n im p o r ta nt e ffe c t o n th e a c c u r a c y o f th e b a r- c o de r e a ding s y s te m . In g e ne r a l:

r Co de 128 a nd Co de 39 a r e m o r e a c c u r a te a nd h a v e lo w e r e r r o r r a te s th a n Co da b a r o r Inte r le a v e d 2-o f-5.

r N CCLS r e c o m m e nds Co de 128 b e c a u s e o f its a c c u r a c y , c o m p a c t fo r m , a nd s e lf-c h e c k ing

c a p a b ilitie s .3

r A c h e c k s u m g r e a tly inc r e a s e s a c c u r a c y . U s e a c h e c k s u m w ith Inte r le a v e d 2-o f-5 a nd Co da b a r b e c a u s e th e y a r e le s s a c c u r a te s y m b o lo g ie s .

r S e le c t th e fix e d le ng th o p tio n, if a v a ila b le , b e c a u s e it is m o r e a c c u r a te th a n th e v a r ia b le le ng th o p tio n.

r T o k e e p la b e l a nd p r inting fla w s to a m inim u m , u s e a na r r o w e le m e nt o f m o r e th a n 0 .25 m m ( 0 .0 10 in.) .

Beck man Cou lter recommen d s the u se of:

r Cod e 128

r Check su m for all other symb olog ies

r Fix ed len g th cod e symb ols

r N arrow b ar siz es of 0.25 mm (0.010 in .) min imu m.

IMPORTANT A mis read lab el can caus e one s amp le ID to b e read as anoth er s amp le ID . W h enever p os s ib le us e a b ar-cod e s y mb olog y and config uration ch oices th at p rovid e th e mos t accurate b ar-cod e read ing .

Page 145: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B B-5

BAR-CODE SPECIFICATIONSB A R -COD E SY M B OL OG IES B

B.5 BAR-CODE SY MBOLOGIESB e c k m a n Co u lte r ins tr u m e nts u s e fo u r b a r-c o de s y m b o lo g ie s fo r s p e c im e n ide ntific a tio n, s e e T a b le B .1.W ith in th e g iv e n s p e c ific a tio ns , th e MCL r e a de r a nd th e o p tio na l h a ndh e ld b a r- c o de r e a de r a u to m a tic a lly dis ting u is h th e fo llo w ing b a r c o de s :

Ta b le B.1 Ba r-Cod e Sy m b olog ies

Ba r-Cod e Ty p e Descrip tion

Cod e 1 28(als o know n as U S D -6)

r V ariab le leng th

r Alp h anumerics ; 1 07 ch aracter s et

r S elf-ch ecking

r Continuous cod e; interch aracter s p ace is p art of cod e s tructure for h ig h er d ens ity of cod e p er s q uare inch ; comp act b ar cod e

r Cod e 1 28 is recommend ed b y th e National Committee for Clinical L ab oratory S tand ard s (NCCL S ) for its accuracy , comp act form, and s elf-ch ecking cap ab ilities 3

r Cod e 1 28B - M aximum 8 alp h anumeric ch aracters

r Cod e 1 28C - M aximum 1 6 numeric ch aracters(T h e us e of 1 5 numeric ch aracters is invalid )

Cod e 39(als o know n as 3-of-9 and U S D -3)

r V ariab le leng th

r Includ es 43 d ata ch aracters ; 26 letters (up p ercas e A-Z ), 1 0 d ig its (0-9), s ix s y mb ols (. $ / + % -) and a s p ace

r S trong s elf-ch ecking p rop erties

r Ch ecks um

r D is crete cod e; w h ite s p aces are not p art of th is cod e

r M aximum 7 ch aracters(6 d ata ch aracters + 1 ch ecks um ch aracter).

Interleaved 2-of-5(als o know n as I2 of 5, U S D -1 , and U S D -1 .25)

r Numerics only

r Ch ecks um

r L ow er d ens ity of cod e p er s q uare inch ; long er lab el

r R eq uires an even numb er of d ig its to b e encod ed , a lead ing “ 0” mus t b e ad d ed if th e numb er count is od d

r Fixed 1 4 ch aracters(1 3 d ata ch aracters + 1 ch ecks um ch aracter).

Cod ab ar(als o know n as U S D -4 and NW 7 )

r V ariab le leng th

r Includ es 1 6 d ata ch aracters ; 1 0 d ig its (0-9), and s ix s y mb ols (. $ / + % -)

r H as s p ecific s tart and s top ch aracters w h ich lead to imp rovement in read ab ility

r Ch ecks um

r L ow er d ens ity of cod e p er s q uare inch ; long er b ar cod e

r M aximum 1 0 ch aracters(9 d ata ch aracters + 1 ch ecks um ch aracter).

Page 146: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BB-6

BAR-CODE SPECIFICATIONSB A R -COD E L A B L ES

B.6 BAR-CODE LABLESA b a r c o de c o ns is ts o f b la c k line s ( b a r s ) a nd w h ite line s ( s p a c e s ) , w h ic h a r e c a lle d e le m e nts .

T h e r e a r e na r r o w e le m e nts ( N E ) a nd w ide e le m e nts ( W E ) . T h e b a r- c o de s y m b o lo g y de te r m ine s th e ir a r r a ng e m e nt.

T h e ins tr u m e nt s u p p o r ts p r e p r inte d la b e ls .

Ba r-Cod e La b el Op tica l Ch a ra cteristics a t 670 nm ± 10 %

r P r int Co ntr a s t S ig na l ( P CS ) : 8 0 % m inim u m .

r R e fle c tiv ity o f Me dia ( R W ) : 8 0 % m inim u m .

r R e fle c tiv ity o f Ink ( R B ) : 16% m a x im u m .

r N o s p o ts o r v o ids ; no ink s m e a r ing .

r E dg e r o u g h ne s s is inc lu de d in th e b a r a nd s p a c e to le r a nc e s .

B.7 MCL BAR-CODE READERT h e MCL u s e s a v is ib le -la s e r ty p e r e a de r c o nta ining a Cla s s II la s e r, o p e r a ting a t 67 0 nm , w ith a m a x im u m p o w e r o u tp u t o f 1 m W .

IMPORTANT S amp le mis id entification can occur from th e us e of incorrect, p oor q uality , d amag ed , d irty or imp rop erly p laced b ar-cod e lab els . Follow th e s p ecifications in th is s ection to create y our b ar-cod e lab els to p revent incorrect s amp le id entification. S ee als o Putting a Bar-Cod e L ab el on a S amp le T ub e.

Ta b le B.2 Cod e-Rela ted Sp ecifica tions

Cod eInterlea v ed 2-of-5* Cod a b a r* Cod e 39* Cod e 128*

Narrow element (NE ) w id th 0.01 0 in. ± 0.001 0.01 0 in. ± 0.001 0.01 0 in. ± 0.001 0.01 0 in. ± 0.001

W id e element/narrow element ratio (W E /NE )

3:1 N/A 3:1 N/A

Interch aracter g ap No 0.01 0 in. minimum _ NE No

D ata d ig its 1 4* * 1 to 1 0* * 1 to 7 * * 2 to 1 6

* S ee AIM U niform S y mb olog y S p ecification, R ev. 1 995 for d etailed s p ecification.* * Includ es ch ecks um ch aracter

P C SRW RB+

RW------------------------ 100%×=

Page 147: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B B-7

BAR-CODE SPECIFICATIONSB A R -COD E D ECOD ER B

B.8 BAR-CODE DECODERT h e MCL s e nds a “ G S ” A S CII c h a r a c te r ( h e x a de c im a l 1D ) to th e de c o de r to s ta r t o p e r a tio n.

T h e de c o de r :

r T u rns th e r e a de r o n.

r D e c o de s info r m a tio n th a t c o m e s fr o m th e r e a de r.

r K e e p s th e r e a de r o n fo r u p to 4 s e c o nds .

r T u rns th e r e a de r o ff.

r S e nds th e de c o de d info r m a tio n ( o r no -r e a d m e s s a g e ) to th e MCL.

B.9 CHECKSUM ALGORITHMB e c k m a n Co u lte r s tr o ng ly r e c o m m e nds th e u s e o f b a r c o de c h e c k s u m s to p r o v ide a u to m a tic c h e c k s fo r r e a d a c c u r a c y .

IMPORTANT T o p revent incorrect id entification of s amp le tub es , d o not us e FNC1 , FNC4, and FS (h exad ecimal 1 C) ch aracters in y our b ar-cod e information.

IMPORTANT U s e of b ar cod es is an extremely accurate and effective meth od of p os itive p atient id entification. Certain features , s uch as ch ecks um d ig its , maximiz e accuracy in read ing Cod ab ar, Cod e 39 and Interleaved 2-of-5 lab els . In one s tud y , th e us e of ch ecks um d ig its d etected 97 % of mis read errors .

U s e ch ecks ums to p rovid e p rotection ag ains t occas ional mis read errors caus ed b y p rob lems s uch as d amag ed or mis ap p lied lab els . If y ou mus t us e b ar cod es w ith out ch ecks ums , Beckman Coulter recommend s th at y ou verify each b ar-cod e read ing to as s ure correct p atient id entification.

Page 148: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BB-8

BAR-CODE SPECIFICATIONSCH ECK SU M A L G OR ITH M

Page 149: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B R E FE R E NCE S -1

REFERENCES

1. A m e r ic a n Ide ntific a tio n Ma nu fa c tu r e r ’s g r o u p ( A IM) , U niform S y mbology S pecifications C ode 3 9 , Interleaved 2 of 5 , C odabar, a nd International S y mbology S pecifications C ode 1 2 8 . A N S I/A IM B C1, B C2, B C3, B C4, 1995. h ttp ://w w w .a im u s a .o r g

2. A m e r ic a n N a tio na l S ta nda rds Ins titu te ( A N S I) B ar C ode P rint Q uality G uidelines. X 3. 18 2-1990 ( R 20 0 0 ) . h ttp ://w w w .a ns i.o r g

3. N a tio na l Co m m itte e fo r Clinic a l La b o r a to r y S ta nda rds ( N CCLS ) , L aboratory A utomation: B ar C odes for S pecimen C ontainer Identification; A pproved S tandard. A U T O 2-A ( I S B N 1-56238 -360 -4) . h ttp ://w w w .nc c ls .o r g

Page 150: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BR E FE R E NCE S -2

REFERENCES

Page 151: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B IND E X -1

INDEX

Num erics3D a c c e le r a tio n

s e tting ne e de d o n v ide o c a rd, 1-123dfx v o o do o b a s e d v ide o c a rds

s e tting ne e de d fo r 3D a c c e le r a tio n, 1-123-o f-9

b a r -c o de , B -548 8 D L filte r

u s e d to s e p a r a te S S , 5-6S ee also filte r s

50 0 LP filte ru s e d to b lo c k la s e r lig h t, 5-7S ee also filte r s

Aa b o u t h e lp

lis ts CX P s o ftw a r e b u ild nu m b e r, 1-38a b s o lu te c o u nts

u s e F lo w -Co u nt flu o r o s p h e r e s , 3-1a c c e s s do o r , tu b e

lo c a tio n, 4-10A cquiring

a p p e a r s du r ing s a m p le c y c le , 4-4, 4-8 , 4-11a c q u is itio n

m o nito r w ith e v e nts /s e c c o u nte r, 4-4, 4-8 , 4-11r u nning s a m p le s in th e a u to m a tic m o de , 4-2r u nning s a m p le s in th e m a nu a l m o de , 4-5r u nning s a m p le s in th e s ing le tu b e m o de , 4-9

a c q u is itio n m a na g e rdr a g a nd dr o p fu nc tio ns , 1-19e nte r th e c a r o u s e l ID nu m b e r, 4-4, 4-7s k ip tu b e s in c a r o u s e l, 1-14to o lb a r

w o r k lis t p a ne l, 1-35w o r k lis t te s t, 1-36

A c tio n lo g s h e e tr e c o rd c le a ning , 2-11r e c o rd da ily s h u tdo w n a c tio ns , 2-11r e c o rd s ta r tu p c h e c k s , 2-8

a dju s tc o lo r c o m p e ns a tio n, 3-1g a in, 3-1h ig h v o lta g e , 3-1s y s te m p r e s s u r e , 2-6S ee also a dju s tm e nt p r o c e du r e s

a dju s tm e nt p r o c e du r e ss c h e du le , 6-11s y s te m p r e s s u r e , 2-6

a ir filte rda ily c h e c k , 2-6w h e n to c a ll s e r v ic e , 2-6

a lig nm e ntv e r ify , 3-1

a m p lific a tio nde s c r ip tio n, 5-10

A P CS ee also F lo w -Ch e c k 67 5 a nd F lo w -S e t 67 5

flu o r o s p h e r e sa p p lic a tio n

c o ntr o l, v e r ify , 3-1IV D , 1-1lis t, fo r th e ins tr u m e nt, 1-2

a p p lic a tio n de finitio nw iz a rd, 3-10

A r g o n la s e rde s c r ip tio n o f h o w its lig h t is h a ndle d, 5-7illu s tr a tio n, 5-5la s e r la b e ls , 6-5O N indic a to r, 1-4S ee also la s e r

a u to a dju s t dis a b le du s e w h e n r u nning a ne g a tiv e c o ntr o l, 3-7

a u to m o deS ee a u to m a tic m o de

a u to s h u tdo w nh o w to s e t u p , 2-14

a u to s ta r tu ph o w to s e t u p , 2-14

A u to G a te r e g io nc o nv e r t fr o m a p o ly g o na l r e g io n, 1-30c r e a ting , 1-28s to p c o u nt o n p lo t, 1-28

a u to m a te d s o ftw a r efe a tu r e s , 5-12

a u to m a ticm o de , r u nning , 4-2

a u to m a tic g a te c r e a tio n, 1-30a u to m a tic m o de

r u nning s a m p le s , 4-2A u to MA T O R

s e tu pdr a g a nd dr o p fu nc tio ns , 1-19

A u to S e tu pc o m p e ns a tio n tu b e s , 3-3p a ne ls

c o ntr o ls u s e d, 3-1p r e p a r e fo r, 3-2

Page 152: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BIND E X -2

INDEX

r u nning a ne g a tiv e c o ntr o l, 3-7v e r ific a tio n tu b e s , 3-3w iz a rd, r u nning , 3-5

a u to s e tu ps c h e du le r, 3-4w iz a rd

A u to S e tu p IIs a v e s e tting s , 3-9

a u to s ta nda rdiz a tio nS ee A u to S e tu p II

A U X p a r a m e te rde s c r ip tio n, 5-12dis p la y indic a to r, 1-5no t a v a ila b le w ith F L5, 5-12w h e n to u s e , 5-12

A waiting S amplea p p e a r s du r ing s a m p le c y c le , 4-4, 4-8 , 4-11a p p e a r s du r ing s ta r tu p c y c le , 2-5r u n flu o r o s p h e r e s , 3-5

Bb a r -c o de

3-o f-9, B -5a c c e p ta b le , B -5Co da b a r, B -5Co de 128 , B -5Co de 39, B -5e r r o r r a te , B -4I2-o f-5, B -5Inte r le a v e d 2-o f-5, B -5N W 7 , B -5s p e c ific a tio ns , B -1s y m b o lo g ie s , B -5U S D -1, B -5U S D -1.25, B -5U S D -3, B -5U S D -4, B -5U S D -6, B -5u s e o f c h e c k s u m , B -7

b a r -c o de de c o de rde s c r ip tio n, B -7

b a r -c o de la b e lsb a s ic o p e r a ting te c h niq u e s , 1-13c o r r e c t p la c e m e nt, B -1la b e l q u a lity , B -3la b e l s iz e , B -2la b e ling s a m p le tu b e s , 1-13o p tic a l c h a r a c te r is tic s , B -6o r ie nta tio n in c a r o u s e l, 1-14

p r int q u a lity , B -3s p e c ific a tio ns , B -2, B -6s y m b o l dim e ns io ns , B -3th ic k ne s s , B -2ty p e s r e a d b y th e MCL, B -5u s e d o n s a m p le c a r o u s e l, 5-1

b a r -c o de r e a de ra c c e p ta b le b a r c o de s , B -5la s e r la b e ls , 6-9MCL, s p e c ific a tio ns , B -6

b a s ic o p e r a ting te c h niq u e s , 1-13b e a ds

S ee flu o r o s p h e r e sb e a m s h a p ing

la s e r, 5-3b le a c h

u s e d in s h u tdo w n c le a ning , 2-11b lo o d

r u n a s a c o ntr o l, 3-1b lu e la s e r

S ee A r g o n la s e rb u tto ns

T a s k b a r, 1-8S ee also ic o ns , S ta r t b u tto n

Cc a lc u la ting

c o m p e ns a tio n c o e ffic ie nts , 3-7c a r o u s e l, s a m p le

b a r -c o de la b e ls , 5-1de s c r ip tio n, 5-1h o m e p o s itio n, 1-15lo a ding s a m p le tu b e s , 1-14p o s itio n 10 u s e d fo r s ing le tu b e m o de , 4-10p u tting a c a r o u s e l in th e MCL, 1-14r e m o v ing a c a r o u s e l fr o m th e MCL, 1-16S ee also MCL

c a r r yr e g io ns fr o m p r e v io u s p r o to c o l, 1-34

CD R Hr e q u ir e d la b e ls , 6-1

c e ll illu m ina tio nde s c r ip tio n, 5-4

c h a r a c te r is tic s , p e r fo r m a nc e , 1-38c h e c k

a ir filte r, 2-6p r e s s u r e g a u g e , 2-6v a c u u m filte r, 2-6v a c u u m g a u g e , 2-6

Page 153: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B IND E X -3

INDEX

v a c u u m tr a p , 2-8w a te r tr a p , 2-6

c h e c k s u m a lg o r ith mCo da b a r, B - 7Co de 39, B - 7Inte r le a v e d 2-o f-5, B - 7

c le a nings c h e du le , 6-11

c le a ning a g e ntc h e c k le v e l a t s ta r tu p , 2-3c o nta ine r , w h e n to c le a n, 6-11

c le a ning p r o c e du r e ss c h e du le , 6-11s u r fa c e a r e a s du r ing s h u tdo w n, 2-11

C leanse L evel E rror, 6-15C leanse L evel Warning, 6-15Co da b a r

b a r -c o de , B -5Co da b a r b a r c o de

c h e c k s u m a lg o r ith m , B -7Co de 128

b a r -c o de , B -5Co de 39

b a r -c o de , B -5Co de 39 b a r c o de

c h e c k s u m a lg o r ith m , B -7c o e ffic ie nts

c a lc u la ting c o m p e ns a tio n, 3-7c o lo r c o m p e ns a tio n

a dju s t, 3-1c a lc u la ting c o e ffic ie nts , 3-7

c o lo r r e s o lu tio nh o w to s e t, 1-11m o nito r, 1-11

c o m p e ns a tio nc a lc u la ting c o e ffic ie nts , 3-7S ee also c o lo r c o m p e ns a tio n

c o m p e ns a tio n c o e ffic ie ntsc o m p e ns a tio n tu b e s , 3-7v e r ific a tio n tu b e s , 3-8

c o m p e ns a tio n tu b e sA u to S e tu p , 3-3p r e p a r e , 3-3p r o c e s s , 3-7u s e d to c a lc u la te c o m p e ns a tio n c o e ffic ie nts , 3-7

c o m p u te rfr o nt v ie w , 1-7

Co ntr o l P a ne lde s c r ip tio n, 1-10h o w to a c c e s s , 1-10

illu s tr a tio n, 1-10W indo w s , 1-10

c o ntr o lsa nd indic a to r s , Cy to m e te r, 1-3fo r A u to S e tu p p a ne ls , 3-1p r e p a r e fo r A u to S e tu p , 3-2Q C p r o c e s s e s u s e d fo r, 3-1r u nning , 3-1r u nning A u to S e tu p , 3-5r u nning F lo w -Ch e c k , 3-2w h o le b lo o d, 3-1S ee also indiv idu a l Q C m a te r ia l na m e s

c o nv e ntio nsu s e d in th e m a nu a l, x iv

c o r r e c t s e tting sv e r ify , 3-1

c r e a tingA u to G a te r e g io ns , 1-28F lo w P A G E , 1-31line a r r e g io ns , 1-26m u ltip le line a r r e g io ns , 1-27p o ly g o na l r e g io ns , 1-22q u a dr a nt r e g io ns , 1-24r e c ta ng u la r r e g io ns , 1-23

c r o s s - c y lindr ic a l le ns e sb e a m s h a p ing , 5-3

CVfo r m u la , 5-16

CX P s o ftw a r ea u to m a te d fe a tu r e s , 5-12b u ild nu m b e r, 1-38s h o r tc u ts , 1-17s h o r tc u ts o n S ta r t b u tto n m e nu , 1-8s ig ning o n, 2-5v e r s io n info r m a tio n, 1-38w h e r e e r r o r m e s s a g e s a p p e a r, 6-11S ee also s o ftw a r e

Cy to -Co m p Ce llsQ C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

Cy to m e te ra u to s h u tdo w n, 2-14a u to s ta r tu p , 2-14c o ntr o ls a nd indic a to r s , 1-3fr o nt v ie w , 1-3indic a to r p a ne ls , 1-4la s e r la b e ls , 6-2, 6-3, 6-4, 6-7r e a dy a nd la s e r o n indic a to r s , 1-4s a m p le flo w r a te indic a to r s , 1-5s e ns o r s , 5-8

Page 154: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BIND E X -4

INDEX

s ig na l a m p litu de indic a to r s , 1-5w h e n to s h u tdo w n, 2-9

Cy to m e te r A u to S ta r tu p , 2-14Cy to m e te r Co ntr o l

dr a g a nd dr o p fu nc tio ns , 1-19Cy to m e te r S ta tu s W indo w

de s c r ip tio n, 6-12illu s tr a tio n, 6-12S ee also e r r o r m e s s a g e s

c y to m e te r .lo g filede s c r ip tio n, 6-13illu s tr a tio n, 6-13S ee also e r r o r m e s s a g e s

c y to m e te r a r c h iv e .lo g filede s c r ip tio n, 6-14S ee also e r r o r m e s s a g e s

Cy to -T r o l Co ntr o l Ce llsQ C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

Dda ily p r o c e du r e s

b e fo r e y o u b e g in, 2-1P r inte r c h e c k s , 2-8Q C p r o c e du r e s , 3-2r e c o rd s h u tdo w n a nd c le a ning , 2-11r e c o rd s ta r tu p c h e c k s , 2-8s e t u p a u to s h u tdo w n, 2-14s e t u p a u to s ta r tu p , 2-14s h u tdo w n, 2-9s ta r tu p , 2-1s ta r tu p p r o c e du r e , 2-1

da ily s ta r tu pb e fo r e y o u b e g in, 2-1S ee also s ta r tu p

D ata R ate Warning, 6-15da ta s to r a g e

de s c r ip tio n, 5-15D ata S tream Warning, 6-15de le te

R e c y c le B in, 1-9D e s k to p

W indo w s , 1-8D e s k to p Me nu B a r

illu s tr a tio n, 1-8dia lo g b o x

de s c r ip tio n, x vdic h r o ic filte r s

S ee filte r s

dis p la y p a ne lflo w r a te indic a to r s , 1-5illu s tr a tio n, 1-4la s e r o n indic a to r, 1-4r e a dy indic a to r, 1-4s ig na l a m p litu de indic a to r s , 1-5

do c u m e nta tio n fo r y o u r ins tr u m e nta b o u t y o u r ins tr u c tio ns fo r u s e m a nu a l, x iiic o nv e ntio ns u s e d, x ivintr o du c tio n to y o u r m a nu a ls , x iiiu s ing th e m a nu a ls , x iii

D o c u m e ntsW indo w s , 1-9

do o r , tu b e a c c e s slo c a tio n, 4-10

do u b le t dis c r im ina tio nu s e th e A U X p a r a m e te r, 5-12

dr a g a nd dr o pa c q u is itio n m a na g e r , fu nc tio ns a v a ila b le , 1-19A u to MA T O R S e tu p , fu nc tio ns a v a ila b le , 1-19Cy to m e te r Co ntr o l, fu nc tio ns a v a ila b le , 1-19de s c r ip tio n, 1-18Mo dify Co lo r P r e c e de nc e , fu nc tio ns

a v a ila b le , 1-19p lo ts , fu nc tio ns a v a ila b le , 1-19P r o to c o l E x p lo r e r , fu nc tio ns a v a ila b le , 1-18r e s o u r c e e x p lo r e r , fu nc tio ns a v a ila b le , 1-18T ile S p e c ia l, fu nc tio ns a v a ila b le , 1-19

Ee dit

q u a dr a nt r e g io n, r e - p o s itio n, 1-25e dit p r o du c ts , 3-14e q u a tio ns

S ee fo r m u la se r r o r m e s s a g e s

CX P s o ftw a r e s c r e e n, 6-11Cy to m e te r S ta tu s W indo w , 6-12c y to m e te r .lo g , de s c r ip tio n, 6-13c y to m e te r a r c h iv e .lo g file , 6-14de s c r ip tio n, 6-11h o w to c le a r, 6-12lis t o f, 6-15r e c o rd in ins tr u m e nt lo g b o o k , 3-5ta b le , 6-15w h e r e dis p la y e d, 6-11

e th a no lu s e d in s h u tdo w n c le a ning , 2-11

E v e nts /S e c c o u nte r

Page 155: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B IND E X -5

INDEX

u s e to m o nito r a c q u is itio n, 4-4, 4-8 , 4-11e x p o r t da ta

Q C da ta , 3-4

FF C 50 0

b a s ic o p e r a ting te c h niq u e s , 1-13c o ntr o ls a nd indic a to r s , 1-3do no t tr a ns fe r s e tting s file s , 3-9illu s tr a tio n, 1-3inte nde d u s e , 1-1m a nu a ls , h a rd-c o p y , x iiip u r p o s e , 1-1s p e c ific a tio ns , 4-1w a r m - u p tim e , 2-4, 3-5S ee also s y s te m

fie ld s to pa ng le s o f F S it c o lle c ts , 5-4fa c to r y s e tting , 5-4

filte r s48 8 D L, fu nc tio n, 5-650 0 LP , fu nc tio n, 5-7a ir , lo c a tio n, 2-6a ir , w h e n to c le a n, 6-11c o nfig u r a tio n, fo u r F L s e ns o r s , 5-7da ily c h e c k a t s ta r tu p , 2-6dic h r o ic , fu nc tio n, 5-7lo ng p a s s ( LP ) , fu nc tio n, 5-7s p a tia l, fu nc tio n, 5-6

F LS ee flu o r e s c e nt lig h t ( F L)

flo w c e llh o w to a v o id c lo g g ing , 4-2, 4-5, 4-9h y dr o dy na m ic fo c u s ing , 5-1illu s tr a tio n, 5-2

flo w r a tes a m p le , indic a to r s , 1-5

F lo w -Ch e c k 67 5 flu o r o s p h e r e sc h a r t fo r a p p lic a tio ns , 3-2Q C p r o c e du r e , 3-2Q C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

F lo w -Ch e c k 7 7 0 flu o r o s p h e r e sc h a r t fo r a p p lic a tio ns , 3-2Q C p r o c e du r e , 3-2Q C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

F lo w -Ch e c k flu o r o s p h e r e sc h a r t fo r a p p lic a tio ns , 3-2

Q C p r o c e du r e , 3-2Q C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

F lo w P A G Ec r e a ting , 1-31de le te , 1-32e x a m p le , 1-31

F lo w - S e t 67 5 flu o r o s p h e r e sc h a r t fo r a p p lic a tio ns , 3-3Q C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

F lo w - S e t 7 7 0 flu o r o s p h e r e sc h a r t fo r a p p lic a tio ns , 3-3Q C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

F lo w - S e t flu o r o s p h e r e sc h a r t fo r a p p lic a tio ns , 3-3Q C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

flu idic s s y s te m sc h e c k s ta b ility , 3-2v e r ify , 3-1

flu o r e s c e nc einte ns ity de te r m ine s p e a k p u ls e h e ig h t, 5-8

flu o r e s c e nt lig h t ( F L)c e ll illu m ina tio n, 5-4c o lle c tio n, 5-6indic a to r s , 1-5w h e n to u s e , e x a m p le , 5-4

flu o r o c h r o m ep r e p a r e c o m p e ns a tio n tu b e fo r e a c h , 3-3

flu o r o s p h e r e sp r e p a r e fo r A u to S e tu p , 3-2p r e p a r e p e r p a c k a g e ins e r ts , 3-2, 3-3, 3-6, 3-10r e -e s ta b lis h r a ng e s w ith ne w lo t, 3-1r u nning A u to S e tu p , 3-5r u nning F lo w -Ch e c k , 3-2u s a g e c h a r t, 3-2, 3-3S ee also indiv idu a l na m e s o f flu o r o s p h e r e s

fo c u s ing , h y dr o dy na m icde s c r ip tio n, 5-1

fo r m u la sCV , 5-16line a r r e g io n s ta tis tic s , 5-16m e a n, 5-16R A T IO p a r a m e te r, 5-13S D ( s ta nda rd de v ia tio n) , 5-16

fo r w a rd s c a tte r ( F S )c e ll illu m ina tio n, 5-4dis p la y indic a to r, 1-4

Page 156: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BIND E X -6

INDEX

lig h t c o lle c tio n, 5-4s e ns o r, 5-4

F SS ee fo r w a rd s c a tte r

Gg a in

a dju s t, 3-1r u n A u to S e tu p to s e t, 3-3

g a tingde s c r ip tio n, 5-15

g a u g e ss y s te m v a c u u m , 2-6

g e ne r a te d s ig na lsde s c r ip tio n, 5-10

g r a p h ic sfo r illu s tr a tio n o nly, x v

g r o u ndu s e r , if s ta tic c h a r g e e x is ts , 2-1

Hh a z a rds

r a dia tio n e x p o s u r e , 6-1He liu m N e o n la s e r

S ee He N e la s e rh e lp

a b o u t, 1-38a b o u t, s e le c t, 1-38a c c e s s ing , 1-37h o w to u s e , 1-37illu s tr a tio n o f la y o u t, 1-37u s ing th e o nline He lp s y s te m , 1-37

He lp Me nu , 1-38He N e la s e r

de s c r ip tio n o f h o w its lig h t is h a ndle d, 5-7illu s tr a tio n, 5-5la s e r la b e ls , 6-6, 6-7s h u tte r o p e n indic a to r, 1-4S ee also la s e r

h ig h v o lta g e sa dju s t, 3-1r u n A u to S e tu p to s e t, 3-3S ee also v o lta g e s

h is to g r a ms ta tis tic s , 5-16ty p e s o f dis p la y , 5-13S ee also p lo ts

h o m e p o s itio n

s a m p le c a r o u s e l, 1-15H ost C ommand Invalid, 6-15h o t k e y s

S ee k e y b o a rd s h o r tc u tsh y dr o dy na m ic fo c u s ing

de s c r ip tio n, 5-1

II2-o f-5

b a r -c o de , B -5ic o ns

c o ntr o l p a ne l, 1-10m y c o m p u te r, 1-10ta s k b a r, 1-8S ee also b u tto ns , T o o lb a r b u tto ns

idleCy to m e te r , p e r fo r m p r im e c y c le b e fo r e r u nning

s a m p le s , 4-1Im m u no -B r ite flu o r o s p h e r e s

Q C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

Im m u no -T r o l Ce llsQ C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

Im m u no -T r o l Lo w Ce llsQ C p r o c e s s u s e d fo r, 3-1S ee also c o ntr o ls

Incorrect C y tometer S erial N umbera p p e a r s w h e n tr a ns fe r ins tr u m e nt s e tting s , 3-9

indic a to r p a ne lsCy to m e te r, 1-4

indic a to r sCy to m e te r r e a dy, 1-4la s e r o n, 1-4le v e l s e ns e , 1-6, 6-20s a m p le flo w r a te , 1-5s h e a th flo w , 1-6s h e a th lo w , 1-6, 6-20s ig na l a m p litu de , 1-5w a s te fu ll, 1-6, 6-20

Initializ ationa p p e a r s du r ing s ta r tu p c y c le , 2-5

ins tr u c tio ns fo r u s e m a nu a linfo r m a tio n o r g a niz a tio n, x iiiu s ing th e m a nu a l, x iii

ins tr u m e ntdo no t tr a ns fe r s e tting s file s , 3-9o p tic a l s y s te m , 5-5

inte nde d u s e o f th e ins tr u m e nt, 1-1

Page 157: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B IND E X -7

INDEX

Inte r le a v e d 2-o f-5b a r -c o de , B -5

Inte r le a v e d 2-o f-5 b a r c o dec h e c k s u m a lg o r ith m , B -7

intr o du c tio n to y o u r m a nu a ls , x iii

Kk e y b o a rd

s h o r tc u ts , 1-17u s e to s e le c t s o ftw a r e c o m m a nds , x v

Lla b e ls

b a r -c o de , s p e c ific a tio ns , B -6CD R H-r e q u ir e d, 6-1la s e r , w a rning , 6-1u niv e r s a l p o w e r s u p p ly , w a rning , 6-10S ee also b a r -c o de la b e ls

la b e ls , b a r -c o deS ee b a r - c o de la b e ls

la b o r a to r y ’s r a ng e sw h e n to r e -e s ta b lis h , 3-1

la s e rb a r -c o de r e a de r , MCL, B -6b e a m s h a p ing , 5-3b lu e , S ee A r g o n la s e rr e d, S ee s o lid-s ta te la s e r o r He N e la s e rr e - e s ta b lis h r a ng e s w h e n r e a lig ne d, 3-1r e -e s ta b lis h r a ng e s w h e n r e p la c e d, 3-1s a fe ty , 6-1w a rning la b e ls , 6-1

L aser C urrent E rror, 6-15L aser P ower E rror, 6-15L aser R egulation Warning, 6-15L aser S tart E rror, 6-15la y o u t

h e lp w indo w , 1-37le ns e s

b e a m s h a p ing , 5-3c r o s s - c y lindr ic a l, 5-3

le v e l s e ns e a nd flo w indic a to r s , 1-6le v e l s e ns e indic a to r s , 6-20

s h e a th lo w , 6-20w a s te fu ll, 6-20

lig h t c o lle c tio n, s e p a r a tio n a nd m e a s u r e m e ntde s c r ip tio n, 5-4

lig h t s c a tte rinte ns ity de te r m ine s p e a k p u ls e h e ig h t, 5-8

lig h tsS ee indic a to r s

line a r r e g io nc r e a ting , 1-26S ee also r e g io ns

line a r itym o nito r ins tr u m e nt, 3-1

lin-lo gm e a n m e th o d, 5-18

lis tm o dede s c r ip tio n, 5-15

lo g o nins tr u c tio ns , 2-4W indo w s s c r e e n, 2-4

lo g -lo gm e a n m e th o d, 5-17

lo ng p a s s ( LP ) filte r sfu nc tio n, 5-7

MMa inte na nc e Lo g

r e c o rd c le a ning , 2-11r e c o rd da ily s h u tdo w n, 2-11r e c o rd s ta r tu p c h e c k s , 2-8

m a nu a l m o dee dit s a m p le ID , 4-6e nte r tu b e lo c a tio n, 4-8h o w to s e le c t, 4-7r u nning s a m p le s , 4-5

m a nu a ls fo r y o u r ins tr u m e nta b o u t y o u r ins tr u c tio ns fo r u s e m a nu a l, x iiic o nv e ntio ns u s e d, x ivh o w to u s e , x iiiintr o du c tio n to y o u r m a nu a ls , x iiiu s ing th e m a nu a ls , x iii

MCL ( Mu lti-T u b e Ca r o u s e l Lo a de r )c h e c k v o r te x fu nc tio n, 2-8do no t o p e n w h ile m o v ing , 4-6illu s tr a tio n, 1-6la s e r la b e ls , 6-8 , 6-9lo a ding th e s a m p le , 5-1p u tting a c a r o u s e l in th e MCL, 1-14r e m o v ing a c a r o u s e l fr o m th e MCL, 1-16tu b e a c c e s s do o r, 4-9u s ing c a r o u s e ls , 1-13S ee also s a m p le c a r o u s e l a nd c a r o u s e l, s a m p le

MCL a u to m a tic m o deS ee a u to m a tic m o de

M C L C arousel In/O ut E rror, 6-16

Page 158: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BIND E X -8

INDEX

M C L C arousel L abel E rror, 6-16M C L C arousel R otate E rror, 6-16M C L C P U E rror, 6-16M C L D oor O pen E rror, 6-16M C L D oor O pen Warning, 6-16M C L E P R O M E rror, 6-16M C L E rror, 6-16M C L Interlock E rror, 6-16MCL m a nu a l m o de

S ee m a nu a l m o deM C L P arallel R ecv E rror, 6-16M C L P arallel S end E rror, 6-16M C L P robe U p/D own error, 6-16M C L P rogram L oad E rror, 6-16M C L R A M E rror, 6-16M C L R ec from F ault E rror, 6-16M C L R eceive Timeout E rror, 6-16M C L R equest E rror, 6-16MCL s a m p le h e a d

w h e n to c le a n, 6-11M C L S erial 1 R ecv E rror, 6-16M C L S erial 1 S end E rror, 6-16M C L S erial 2 R ecv E rror, 6-17M C L S erial 2 S end E rror, 6-17M C L Transmit Timeout E rror, 6-17M C L Tube D isplaced E rror, 6-17M C L Tube Jam E rror, 6-17M C L Tube L oad E rror, 6-17M C L Tube P osition E rror, 6-17M C L Tube U p/D own E rror, 6-17m e a n

fo r m u la , 5-16lin-lo g m e th o d, 5-18lo g -lo g m e th o d, 5-17

m e a n p o s itio na s c e r ta in ta r g e t, 3-1

m e s s a g e se r r o r , de s c r ip tio n, 6-11e r r o r , lo g , 6-13e r r o r , w h e r e dis p la y e d, 6-11

m is m a tc h e d ID s , 4-4, 4-8 , 4-11m o de

a u to m a tic , 4-2de finitio n, 5-16m a nu a l, 4-5s ing le tu b e m o de , 4-9

Mo dify Co lo r P r e c e de nc edr a g a nd dr o p fu nc tio ns , 1-19

m o nito r

c o lo r r e s o lu tio n, 1-11fr o nt v ie w , 1-7ins tr u m e nt line a r ity , 3-1

m o u s eu s ing , 1-10

m u ltip le line a r r e g io nsc r e a ting , 1-27

My Co m p u te rW indo w s , 1-10

Nna v ig a tio n p a ne

illu s tr a tio n, 1-37lo c a tio n, 1-37

ne g a tiv e c o ntr o la dditio na l s te p s in A u to S e tu p w iz a rd, 3-7r u nning , 3-7

ne tw o r klo g in a t s ta r tu p , 2-4s e a r c h fo r file s , fo lde r s , a nd c o m p u te r s , 1-9

ne w p a ne lc a r r y r e g io ns fr o m p r e v io u s p r o to c o l, 1-34u s e ins tr u m e nt s e tting s , 1-34u s e ins tr u m e nt s e tting s fr o m e x te rna l file , 1-34u s e ins tr u m e nt s e tting s fr o m p r e v io u s te s t, 1-34u s e p lo ts a nd g a te s fr o m p r o to c o l, 1-34u s e r e g io ns fr o m p r o to c o l, 1-34u s e r e g io ns fr o m th is p r o to c o l, 1-34

ne w p a ne l w iz a rdS ee p a ne l w iz a rd

N W 7b a r -c o de , B -5

Oo nline He lp

S ee h e lpo p e r a tio n

p r inc ip le s o f, 5-1o p tic a l

s y s te m , 5-5s y s te m s , c h e c k s ta b ility , 3-2

o p tic a l a r e ala s e r la b e ls , 6-3, 6-4

o p tic a l c h a r a c te r is tic sb a r -c o de la b e ls , B -6fo r b a r - c o de la b e ls , B -6

o p tic a l filte r p la tede s c r ip tio n, 5-7

Page 159: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B IND E X -9

INDEX

filte r c o nfig u r a tio n, 5-7

Pp a c k a g e ins e r ts

c o nta in flu o r o s p h e r e s ins tr u c tio ns , 3-2, 3-3r e a g e nt, u s e to p r e p a r e s a m p le s , 4-2, 4-5, 4-9u s e to e s ta b lis h e x p e c te d r a ng e s , 3-6u s e to e s ta b lis h no r m a l r a ng e s , 3-1u s e to e s ta b lis h ta r g e t c h a nne ls , 3-6, 3-10u s e to p r e p a r e CY T O -T R O L c e lls , 3-3u s e to p r e p a r e I m m u no -T r o l c e lls , 3-3

p a ne l r e p o r tg e ne r a te , 1-32

p a ne l w iz a rdc r e a te ne w p a ne ls , 1-32

p a ne lsc a n s k ip tu b e s b e tw e e n p a ne ls , 1-14c le a ns e p a ne l, de s c r ip tio n, 5-11c r e a ting , 1-32do no t s k ip tu b e s w ith in p a ne l, 1-14h o w to s e le c t, 4-4, 4-7 , 4-10ne w , 1-32p a ne l w iz a rd, 1-32Q C, ne e d u niq u e p r o to c o ls , 3-13s p e c ia l, 5-11w h a t to do if th e r e is a de le te d

p r o to c o l, 4-4, 4-7 , 4-10S ee also ne w p a ne l

p a r a m e te r sA U X , 5-12de s c r ip tio n, 5-12na m e s , 1-34R A T IO , 5-13r u n A u to S e tu p to s e t g a ins , 3-3T IME , 5-12

p a s s w o rdse nte r a t lo g o n, 2-4fo r a u to s ta r tu p /s h u tdo w n, 2-14

P C7S ee also F lo w -Ch e c k 7 7 0 a nd F lo w -S e t 7 7 0

flu o r o s p h e r e sp e a k s ig na l

de s c r ip tio n, 5-8S ee also s ig na ls

p e r fo r m a nc e c h a r a c te r is tic s , 1-38p h e no ty p e

de finitio n, 5-13p h o to s e ns o r s

S ee s e ns o r s

p ic k u p le ns /s p a c ia l filte r a s s e m b lyfu nc tio n, 5-6

p lo tsdr a g a nd dr o p fu nc tio n, 1-19P R IS M, 5-13P R IS M, illu s tr a tio n, 5-14ty p e s o f dis p la y , 5-13S ee also h is to g r a m s , c o lo r do t p lo ts , c o nto u r

p lo ts , de ns ity p lo ts , do t p lo ts , h is to g r a m p lo ts a nd p r is m p lo ts

P MTr e - e s ta b lis h r a ng e s w h e n r e p la c e d, 3-1S ee also h ig h v o lta g e s

p o ly g o na l r e g io nc o nv e r t to a n A u to G a te r e g io n, 1-30c r e a ting , 1-22S ee also r e g io ns

p o s itio n 10u s e d fo r s ing le tu b e m o de , 4-10

p o w e r fa ilu r eh o w to h a ndle s a m p le s , 4-2

P o w e r S u p p lyfr o nt v ie w , 1-7u niv e r s a l, 1-7u niv e r s a l, w a rning la b e ls , 6-10v o lta g e - s p e c ific , 1-7

p r e c a u tio nsa g a ins t r a dia tio n, 6-1

P r e p a r ing A u to S e tu p R e a g e nts , 3-2P reparing S ample

a p p e a r s du r ing s a m p le c y c le , 4-4, 4-8 , 4-11p r im e c y c le

inc lu de d in s ta r tu p c y c le , 2-5w h e n to r e q u e s t, 4-1

p r inc ip le s o f o p e r a tio n, 5-1P r inte r

da ily c h e c k s , 2-8o p e r a ting ins tr u c tio ns , 1-7

P R IS Mde s c r ip tio n, 5-13p lo t, 5-14s ig na ls th a t c a n b e a s s ig ne d to it, 5-14w h e n to u s e , 5-13

P r o g r a m sW indo w s , 1-9

P r o to c o l E x p lo r e rdr a g a nd dr o p fu nc tio ns , 1-18

p r o to c o lsA S , de s c r ip tio n, 5-11c le a ns e b le a c h .p r o , 5-11

Page 160: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BIND E X -1 0

INDEX

c le a ns e di w a te r .p r o , 5-11Cle a ns e , de s c r ip tio n, 5-11c r e a ting , 1-20de finitio n, 5-11de s c r ip tio n, 5-11dr a g a nd dr o p fu nc tio n, 1-18h o w to s e le c t, 4-4, 4-7 , 4-10info r m a tio n c o nta ine d, 5-11ne w , 1-20Q C, de s c r ip tio n, 5-11s p e c ia l, 5-11u s e d in A u to S e tu p p a ne ls , 5-11w h a t to do if th e r e is a de le te d p r o to c o l in a

p a ne l, 4-4, 4-7 , 4-10S ee also ne w p r o to c o l

P u b lis h D a ta to MS E x c e lu s e fo r Le v e y Je nning s p lo ts , 5-11

p u ls eS ee s ig na ls

QQ C m a te r ia ls

Q C p r o c e s s e s u s e d fo r, 3-1S ee also q u a lity c o ntr o l ( Q C)

q u a dr a nt r e g io nc r e a ting , 1-24e diting , r e - p o s itio n, 1-25S ee also r e g io ns

q u a lity c o ntr o l ( Q C) , 3-1a b o u t, 3-1a s s ig ning Q C p r o du c ts , 3-14a u to s e tu p s c h e du le r, 3-4a u to s e tu p w iz a rdc h e c k s p e c ific a p p lic a tio ns , 3-1da ily p r o c e du r e s , 3-2e dit p r o du c ts , 3-14e x p o r t Q C da ta to s p r e a ds h e e t, 3-4F lo w -Ch e c k flu o r o s p h e r e s , 3-2F lo w - S e t flu o r o s p h e r e s , 3-3p r o du c ts , 3-14Q C m a te r ia ls u s e d fo r Q C p r o c e s s , 3-1Q C p r o c e s s e s , 3-1r e v ie w r e s u lts , 3-15s e tting u p Q C p r o du c ts , 3-14

Rr a dia tio n h a z a rds , 6-1r a ng e s , la b o r a to r y ’s

e s ta b lis h e x p e c te d r a ng e s , 3-6w h e n to r e -e s ta b lis h , 3-1

R A T IO p a r a m e te rde s c r ip tio n, 5-13fo r m u la , 5-13

r e a g e ntsc h e c k le v e l a t s ta r tu p , 2-3

r e c o rdc le a ning , 2-11da ily s h u tdo w n, 2-11s ta r tu p c h e c k s , 2-8

r e c ta ng u la r r e g io nc r e a ting , 1-23S ee also r e g io ns a nd q u a dr a nt r e g io n

R e c y c le B inW indo w s , 1-9

r e d la s e rS ee s o lid-s ta te la s e r o r He N e la s e r

r e g io nsA u to G a te , 1-28c a r r y fr o m p r e v io u s p r o to c o l, 1-34c r e a ting

A u to G a te r e g io n, 1-28line a r r e g io n, 1-26m u ltip le line a r r e g io ns , 1-27p o ly g o na l r e g io n, 1-22q u a dr a nt r e g io n, 1-24r e c ta ng u la r r e g io n, 1-23

de s c r ip tio n, 5-15line a r r e g io n, 1-26m u ltip le line a r r e g io ns , 1-27p o ly g o na l r e g io n, 1-22q u a dr a nt r e g io n, 1-24

r e -p o s itio n, 1-25r e c ta ng u la r r e g io n, 1-23ty p e s , 5-15ty p e s o f fu nc tio ns , 5-15

r e p la c e m e nt p r o c e du r e ss c h e du le , 6-11

r e p o r ting u nitss h o w n in U S u nit fo r m a t, x v

r e q u ir e m e nts , s a m p le , 4-1r e s o lu tio n

s e t c o lo r m o nito r, 1-11r e s o u r c e e x p lo r e r

dr a g a nd dr o p fu nc tio ns , 1-18r e s u lts

r e v ie w Q C r e s u lts , 3-15R o m lo c k

Page 161: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B IND E X -1 1

INDEX

nu m b e r o n R o m lo c k , 1-38R u n

W indo w s , 1-9r u nning

a p p lic a tio n de finitio n w iz a rd, 3-10a u to s e tu p w iz a rdF lo w -Ch e c k flu o r o s p h e r e s , 3-2F lo w - S e t flu o r o s p h e r e s , 3-3s a m p le s in MCL a u to m a tic m o de , 4-2s a m p le s in MCL m a nu a l m o de , 4-5s a m p le s in s ing le tu b e m o de , 4-9

Ss a fe ty p r e c a u tio ns

la s e r, 6-1s a m p le

c h e c k s b e fo r e r u nning , 4-1flo w , de s c r ip tio n, 5-1h o w to h a ndle a fte r p o w e r fa ilu r e , 4-2illu m ina te d in th e flo w c e ll, 5-4lo a ding , a u to m a te d, 5-1m e a s u r a b le c e ll s iz e s , 4-1o p tim u m c o nc e ntr a tio n, 4-1p r e p a r a tio n, 4-1p r e p a r e p e r r e a g e nt p a c k a g e ins e r t, 4-2, 4-5, 4-9r e q u ir e m e nts , 4-1r is k o f m is ide ntific a tio n, 4-2r u n s a m p le s in MCL a u to m a tic m o de , 4-2r u n s a m p le s in MCL m a nu a l m o de , 4-5r u n s a m p le s in s ing le tu b e m o de , 4-9v e r ify m a nu a lly e nte r e d info r m a tio n b e fo r e

r e p o r ting r e s u lts , 4-5, 4-9, 4-11s a m p le c a r o u s e l

b a r -c o de la b e ls , 5-1de s c r ip tio n, 5-1e nte r th e ID nu m b e r, 4-4, 4-7h o m e p o s itio n, 1-15p u tting a c a r o u s e l in th e MCL, 1-14r e m o v ing a c a r o u s e l fr o m th e MCL, 1-16S ee also c a r o u s e l, s a m p le a nd MCL

s a m p le flo wde s c r ip tio n, 5-1r a te indic a to r s , 1-5

s a m p le IDc a n e dit a fte r e a c h tu b e in m a nu a l m o de , 4-5c a n e dit a fte r e a c h tu b e in s ing le tu b e m o de , 4-9s to p e a c h tu b e s o y o u c a n e dit in m a nu a l

m o de , 4-6s to p e a c h tu b e s o y o u c a n e dit in s ing le tu b e

m o de , 4-9S ample P ressure E rror, 6-17s a m p le p r o b e

h o w to a v o id c lo g g ing , 4-2, 4-5, 4-9w h e n to c le a n, 6-11

s a m p le tu b eS ee te s t tu b e

s a m p le tu b ingh o w to a v o id c lo g g ing , 4-2, 4-5, 4-9

s a m p ling s y s te mw h e n to c le a n, 6-11

s c h e du lea dju s tm e nt p r o c e du r e s , 6-11a u to s h u tdo w n, 2-15a u to s ta r tu p , 2-15c le a ning , 6-11r e p la c e m e nt, 6-11

S D ( s ta nda rd de v ia tio n)fo r m u la , 5-16

S e a r c hW indo w s , 1-9

s e c u r ityW indo w s 20 0 0 p a s s w o rd, 1-8

s e ns ing c o m p a r tm e ntla s e r la b e ls , 6-2

s e ns o r sCy to m e te r, 5-8

S ensors S tream Warning, 6-17s e tting s

do no t tr a ns fe r file s b e tw e e n ins tr u m e nts , 3-9s a v e fr o m A u to S e tu p I I, 3-9W indo w s , 1-9

S heath D rawer E rror, 6-17s h e a th flu id

flo w indic a to r, 1-6lo w indic a to r, 1-6, 6-20

s h e a th flu id c o nta ine rw h e n to c le a n, 6-11

s h e a th flu id flo w indic a to rlo c a tio n, 1-6

S heath L evel E rror, 6-17S heath L evel Warning, 6-17s h e a th lo w indic a to r

de s c r ip tio n, 6-20lo c a tio n, 1-6, 6-20

S heath P ressure E rror, 6-18s h o r tc u ts , s o ftw a r e , 1-17

dr a g a nd dr o p , 1-18k e y b o a rd, 1-17

S h u t D o w n

Page 162: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BIND E X -1 2

INDEX

W indo w s , 1-9s h u tdo w n

da ily s h u tdo w n, 2-9e x te nde d, p r o c e du r e , 2-12h o w to s e t u p a u to s h u tdo w n, 2-14m inim u m tim e , 2-9w h e n to s h u t do w n th e Cy to m e te r, 2-9

s ide s c a tte r ( S S )c e ll illu m ina tio n, 5-4c o lle c tio n, 5-6s e ns o r, 5-6w h e n to u s e , e x a m p le , 5-4

s ig na l a m p litu de indic a to r s , 1-5s ig na ls

a m p lific a tio n, 5-10g e ne r a te d, 5-10inte g r a l, de s c r ip tio n, 5-10inte g r a l, illu s tr a tio n, 5-10inte g r a l, ty p e s , 5-10p e a k , de s c r ip tio n, 5-8p e a k , illu s tr a tio n, 5-9, 5-10p r o c e s s ing o f, o p e r a tio n p r inc ip le s , 5-8v o lta g e p u ls e , 5-8

s ig ning o n to CX P s o ftw a r e , 2-5s ing le tu b e m o de

e dit s a m p le I D , 4-9h o w to r e q u e s t, 4-10r u nning s a m p le s , 4-9u s e s p o s itio n 10 in c a r o u s e l, 4-10

s k ip p o s itio nsb e tw e e n p a ne ls , 1-14no t w ith in a p a ne l, 1-14

s o ftw a r eo nline h e lp s y s te m , 1-37s h o r tc u ts , 1-17s ig ning o n to CX P s o ftw a r e , 2-5

s o lid-s ta te la s e rillu s tr a tio n, 5-5la s e r la b e ls , 6-5, 6-6S ee also la s e r

s p a tia l filte rS ee filte r s

s p e c ia l p a ne ls , 5-11s p e c ia l p r o to c o ls , 5-11s p e c ific a tio ns

b a r -c o de la b e ls , B -2, B -6s p e c im e n

S ee s a m p les p r e a ds h e e t

e x p o r t Q C da ta , 3-4S S

S ee s ide s c a tte rs ta b ility

c h e c k flu idic s s y s te m s , 3-2c h e c k o p tic a l s y s te m s , 3-2

s ta insc o m p e ns a tio n tu b e s , 3-3v e r ific a tio n tu b e , 3-3

S ta r t b u tto nde s c r ip tio n, 1-8m e nu , illu s tr a tio n, 1-8W indo w s , 1-8

s ta r te r k itMCL s u p p lie s , 1-13

s ta r tu pb e fo r e y o u b e g in, 2-1da ily p r o c e du r e , 2-1da ily s ta r tu p , 2-1h o w to s e t u p a u to s ta r tu p , 2-14lo g into ne tw o r k , 2-4r e c o rd da ily c h e c k s , 2-8

S tartup in P rocessa p p e a r s du r ing s ta r tu p c y c le , 2-5

S tate M achine F ailure, 6-18s ta tic c h a r g e

u s e r ne e ds to b e g r o u nde d, 2-1s ta tis tic s

h is to g r a m , 5-16line a r r e g io n, 5-16lo g r e g io n, 5-17

s ta tu s m e s s a g e sr u nning flu o r o s p h e r e s , 3-5s a m p le c y c le m e s s a g e s , 4-4, 4-8 , 4-11s ta r tu p c y c le m e s s a g e s , 2-5

s to p c o u nte ffe c t o n A u to G a te r e g io n, 1-28

S toppinga p p e a r s du r ing s a m p le c y c le , 4-4, 4-8 , 4-11

s y s te mc o ntr o ls a nd indic a to r s , 1-3o p tic a l, 5-5S ee also F C 50 0

s y s te m p r e s s u r ec o r r e c t r a ng e , 2-6g a u g e lo c a tio n, 2-6h o w to a dju s t, 2-6

S y stem P ressure E rror, 6-18s y s te m v a c u u m

Page 163: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B IND E X -1 3

INDEX

da ily c h e c k , 2-6g a u g e lo c a tio n, 2-6

S y stem V acuum E rror, 6-18s y s te m v a c u u m g a u g e

w h e n to c a ll s e r v ic e , 2-6

Tta r g e t c h a nne ls , la b o r a to r y ’s

e s ta b lis h ta r g e t c h a nne ls , 3-6, 3-10T a s k b a r

b u tto ns , 1-8de s c r ip tio n, 1-8ic o ns , 1-8illu s tr a tio n, 1-8S ta r t b u tto n, 1-8W indo w s , 1-8

Temperature E rror, 6-18Temperature S ensor F ailure, 6-18Temperature Warning, 6-18te s t tu b e

h o w to a p p ly b a r - c o de la b e l, 1-13ID m is m a tc h , h o w th e s y s te m

h a ndle s , 4-4, 4-8 , 4-11illu s tr a tio n in s a m p le c a r o u s e l, 1-14lo a ding c a r o u s e l, 1-14p u t into th e c a r o u s e l, 1-14s iz e , 4-1

T ile S p e c ia ldr a g a nd dr o p fu nc tio ns , 1-19

T IME p a r a m e te rde s c r ip tio n, 5-12

to o lb a rb u tto ns , 1-19T a s k b a r b u tto ns , 1-8

to p ic p a neillu s tr a tio n, 1-37lo c a tio n, 1-37

Transputer 1 E rror, 6-18Transputer 2 E rror, 6-18Transputer L ink E rror, 6-19Transputer L ink Warning, 6-19tr o u b le s h o o ting , 6-1

e r r o r m e s s a g e lo g , 6-13e r r o r m e s s a g e s , 6-11le v e l s e ns e indic a to r s , 6-20

tu b e a c c e s s do o rillu s tr a tio n, 4-10lo c a tio n, 4-10u s e fo r s ing le tu b e m o de , 4-9

tu b e , s a m p leS ee te s t tu b e

UU nk nown S tream Warning, 6-19U S D -1

b a r -c o de , B -5U S D -1.25

b a r -c o de , B -5U S D -3

b a r -c o de , B -5U S D -4

b a r -c o de , B -5U S D -6

b a r -c o de , B -5u s e

ins tr u m e nt s e tting s , 1-34ins tr u m e nt s e tting s fr o m e x te rna l file , 1-34ins tr u m e nt s e tting s fr o m p r e v io u s te s t, 1-34p lo ts a nd g a te s fr o m p r e v io u s te s t, 1-34p lo ts a nd g a te s fr o m p r o to c o l, 1-34r e g io ns fr o m p r o to c o l, 1-34r e g io ns fr o m th is p r o to c o l, 1-34

u s e a nd fu nc tio n, ins tr u m e nt, 1-1U s e r I D , 2-5u s e r na m e

S ee U s e r I Du s ing

m o u s e , 1-10th e o nline h e lp s y s te m , 1-37

VV acuum C hamber Warning, 6-19v a c u u m filte r

da ily c h e c k , 2-6lo c a tio n, 2-6w h e n to c a ll s e r v ic e , 2-6

v a c u u m g a u g eda ily c h e c k , 2-6

v a c u u m tr a pda ily c h e c k , 2-8lo c a tio n, 2-8w h e n to c le a n, 6-11

v a c u u m , c h e c k ingda ily s ta r tu p , 2-6s y s te m v a c u u m g a u g e , 2-6v a c u u m filte r, 2-6v a c u u m tr a p , 2-8

Page 164: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923BIND E X -1 4

INDEX

V erificationa p p e a r s du r ing s ta r tu p c y c le , 2-5

v e r ific a tio n tu b e sA u to S e tu p , 3-3c o m p e ns a tio n c o e ffic ie nts , 3-8

v e r ifya lig nm e nt, 3-1a p p lic a tio n c o ntr o l, 3-1c o r r e c t s e tting s , 3-1flu idic s s y s te m s , 3-1HP CV v e r s u s e x p e c te d v a lu e , 3-1

v ide o c a rdss e tting ne e de d fo r 3D a c c e le r a tio n, 1-12

v ir u s p r o te c tio n p r o g r a ms h u tdo w n c o m p u te r, 2-1

v ir u s s c a nno t w h ile r u nning CX P , 2-1

v o lta g e p u ls e s ig na lsde s c r ip tio n, 5-8S ee also s ig na ls

v o lta g e sa dju s t, 3-1a dju s t to u s e ne g a tiv e c o ntr o l, 3-7r u n A u to S e tu p to s e t, 3-3S ee also h ig h v o lta g e s

Ww a r m - u p

ins tr u m e nt, 2-4, 3-5Waste B ack pressure E rror, 6-19w a s te c o nta ine r

e m p ty a t s ta r tu p , 2-2w a s te fu ll indic a to r, 6-20

w a s te fu ll indic a to rde s c r ip tio n, 6-20lo c a tio n, 1-6, 6-20

Waste L evel E rror, 6-19Waste L evel Warning, 6-19w a te r tr a p

da ily c h e c k , 2-6lo c a tio n, 2-6w h e n to c a ll s e r v ic e , 2-6

w e b s itea c c e s s to A p p lie d Cy to m e tr y S y s te m s , 1-38a c c e s s to B e c k m a n Co u lte r, 1-38

w h e n to c a ll s e r v ic ea ir filte r, 2-6s y s te m v a c u u m g a u g e , 2-6v a c u u m filte r, 2-6

w a te r tr a p , 2-6w h e n to s h u tdo w n, 2-9w h o le b lo o d

r u n a s a c o ntr o l, 3-1W indo w s

Co ntr o l P a ne l, 1-10D e s k to p , 1-8D o c u m e nts , 1-9He lp , 1-9My Co m p u te r, 1-10p a s s w o rd s e c u r ity , 1-8P r o g r a m s , 1-9R e c y c le B in, 1-9R u n, 1-9S e a r c h , 1-9S e tting s , 1-9S h u t D o w n, 1-9S ta r t b u tto n, 1-8T a s k b a r, 1-8

w iz a rdA u to S e tu p , r u nning , 3-5p a ne l S ee p a ne l w iz a rd

w o r k lis th o w to s e le c t, 4-4, 4-7 , 4-10p a ne l, 1-35te s t, 1-36

W o r k s ta tio nfr o nt v ie w , 1-7

Page 165: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

PN 624923B

TRADEMARKS

A LT R A , B E CK MA N CO U LT E R lo g o , CO U LT E R , CO U LT E R CLE N Z , CY T O -CO MP, CY T O -T R O L, E lite , E P ICS , F lo w Ce ntr e , F lo w -Ch e c k , F lo w -Co u nt, F lo w - S e t, Im m u no -B r ite , Im m u no P r e p , I m m u no -T r o l, Is o F lo w , Mu lti-Q - P r e p , Q -P r e p , S te m -Co u nt, S te m -T r o l, T Q -P r e p , X L, a nd X L-MCL a r e tr a de m a r k s o f B e c k m a n Co u lte r, Inc .

A ll o th e r tr a de m a r k s , s e r v ic e m a r k s , p r o du c ts , o r s e r v ic e s a r e tr a de m a r k s o r r e g is te r e d tr a de m a r k s o f th e ir r e s p e c tiv e h o lde r s .

Page 166: Cytomics FC 500 - Rutgers Universityrwjms1.rwjms.rutgers.edu/flow/documents/FC-500InstrforUse-IFU.pdf · Cytomics FC 500 With CXP Software Instructions For Use PN 624923B (June 2004)

Printed on R ecy cled Pap er

Cy tom ics FC 50 0 w ith CX P Softw a re Docum enta tion

s R e fe r e nc eP N 17 557 0

U s e a nd F u nc tio n • Ins ta lla tio n • S p e c ific a tio ns • Lo g S h e e ts • U s ing CX P S o ftw a r e • G lo s s a r y • Inde x

s S p e c ia l P r o c e du r e sP N 17 557 2

Cle a ning P r o c e du r e s • R e p la c e /A dju s t P r o c e du r e s • Inde x

s Ins tr u c tio ns F o r U s eP N 624923

S y s te m O v e r v ie w • D a ily R o u tine • Q u a lity Co ntr o l • R u nning S a m p le s • O p e r a tio n P r inc ip le s • T r o u b le s h o o ting • Ho w to ... • B a r-Co de S p e c ific a tio ns • R e fe r e nc e s • Inde x

s Ma s te r Inde xP N 17 7 653

Co m b ine d inde x fo r th e Ins tr u c tio ns F o r U s e , S p e c ia l P r o c e du r e s , a nd R e fe r e nc e m a nu a ls .

s G e tting S ta r te dP N 17 7 652

O v e r v ie w o f th e s y s te m h a rdw a r e a nd s o ftw a r e .

s O p e r a to r Ma nu a lsCD -R O MP N 17 7 628

HT ML file o f th e S y s te m He lp • P D F file s o f th e R e fe r e nc e m a nu a l, Ins tr u c tio ns fo r U s e , a nd S p e c ia l P r o c e du r e s m a nu a l.

C ome visit us at www.beck mancoulter.com

Beckman Coulter Ireland Inc.M ervue Bus ines s Park,M ervue, G alw ay ,Ireland (353 91 7 7 4068)

Cop y rig h t © Beckman Coulter, Inc. 2004All R ig h ts R es erved